1.
Radiother Oncol ; 88(3): 335-41, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18514339

RESUMO

BACKGROUND AND PURPOSE: Loco-regional failure after radiotherapy with total doses of 60-70 Gy for non-small cell lung cancer (NSCLC) remains a major clinical problem. Escalation of radiation dose is often limited because of exceeding normal tissue constraints. The present study was designed to test the hypothesis that a reduction in disease volume during radiotherapy detected by FDG PET/CT would facilitate radiation dose escalation, whilst remaining within normal tissue constraints. MATERIALS AND METHODS: Ten patients with localised inoperable NSCLC were prospectively enrolled. Each received standard 3D-conformally planned radiotherapy to a dose of 66 Gy in 33 fractions over 6.5 weeks. FDG PET/CT imaging in the treatment position was performed prior to treatment and repeated following 50 or 60 Gy. CT and PET-delineated gross tumour volumes were generated and a composite created. A margin of 15mm was added in all planes to form the planning target volume (PTV). Treatment planning was performed to compare two dose escalation strategies: 78 Gy delivered to the initial PTV with treatment in two phases (shrinking field), i.e., 66 Gy to the initial PTV with a 12 Gy-boost to the PTV after 50/60 Gy. As an alternative planning approach the maximal dose without exceeding normal tissue constraints was evaluated for each patient (individualized dose prescription). RESULTS: There was a median PTV reduction after 50/60 Gy of 20%. Delivering 78 Gy to the initial PTV could have been achieved in 4/10 patients. Of the remaining 6, delivering 78 Gy to the initial PTV would have exceeded normal tissue constraints and no benefit was seen when delivered in two phases. The results from the individualized dose prescription indicated a higher median maximal dose when treatment would be given in two phases compared to one phase resulting in a modest increase of calculated tumour control probability. CONCLUSIONS: Our data suggest that despite tumour shrinkage determined by subsequent FDG PET/CT during treatment the tested adaptive targeting strategy would result only in a modest improvement in the context of dose escalation. Further studies on the optimal use of FDG PET/CT and other approaches for dose escalation in loco-regionally advanced NSCLC are warranted.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Tomografia por Emissão de Pósitrons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Fracionamento da Dose de Radiação , Relação Dose-Resposta à Radiação , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
2.
Strahlenther Onkol ; 183(2): 76-80, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17294111

RESUMO

BACKGROUND AND PURPOSE: The Winston-Lutz test verifies the mechanical accuracy of the isocenter in stereotactic radiotherapy. A lead ball inside a small beam is exposed to film applying different combinations of the gantry angle and the table angle. The increasing replacement of films by digital images requires alternative imaging methods. The suitability of two different electronic portal imaging systems and of a system based on digital luminescence radiography was investigated. MATERIAL AND METHODS: The imaging systems included the portal imaging devices BEAMVIEW PLUS and OPTIVUE1000 (both Siemens Medical Solutions, Erlangen, Germany) and the luminescence system KODAK ACR 2000 RT (Eastman Kodak Comp., Rochester, NY, USA). 6-MV photons from the linear accelerators PRIMUS and ONCOR (both Siemens Medical Solutions) were applied. First, only the small beam covering the lead ball was exposed. Second, an additional bigger open beam part in a certain distance to the small beam was applied. RESULTS: For all three investigated imaging systems, which are using preprocessing imaging software, only for the beam arrangement with additional open beam parts, the lead ball could be detected inside the small beam. Only for the application of a dosimetric software tool to the luminescence system, the metal ball inside the small beam became visible without an additional open beam part. CONCLUSION: Applying the proposed beam arrangements, the Winston-Lutz test can be done by digital and filmless imaging systems, thereby saving time as well.


Assuntos
Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radiometria/métodos , Radiocirurgia/métodos , Radiocirurgia/normas , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Análise de Falha de Equipamento/instrumentação , Análise de Falha de Equipamento/métodos , Alemanha , Mecânica , Radiometria/normas , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Filme para Raios X