Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur J Cardiothorac Surg ; 59(6): 1174-1181, 2021 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-33709139

RESUMO

OBJECTIVES: Patients scheduled for transcatheter aortic valve implantation (TAVI) treatment frequently present with concomitant aortic diseases, in which case they are usually considered to be at high interventional risk and, in particular, unable to undergo the transfemoral TAVI approach. Since the establishment of the 'transfemoral first' strategy for TAVI, there has been an evidence gap with regard to the outcomes of such patients. We aimed to evaluate the mid-term outcomes after transapical TAVI in patients with diverse aortic diseases. METHODS: Fifty-five consecutive elderly patients (78.4 years; standard deviation: 8.6 years) at intermediate surgical risk with severe aortic stenosis and aortic diseases (porcelain aorta 36%, ascending aneurysm 15%, descending aneurysm 26%, type-B dissection 4%, aortic thrombus 7%, Leriche syndrome 4%, aortic kinking 11%, aortic ulcer 2%, previous aortic operation 20%, aortic elongation/tortuosity 4%) underwent transapical TAVI treatment between January 2011 and November 2019 at our institution. We used the second-and third-generation self- and balloon-expanding valves. The follow-up time was 92.6 patient-years. RESULTS: The Society of Thoracic Surgery-Predicted Risk of Mortality score was 7% (standard deviation: 4%). The 30-day mortality and all-stroke rates were 6% and 4%, respectively. The median survival time was 24.9 months (95% confidence interval 17.6-32.3). The median time of freedom from a composite of death and cardio-cerebral adverse events was 24.3 months (95% confidence interval 11.9-36.8). The rate of moderate/severe paravalvular leakage was 2%. The pacemaker rate was 10%. No early or late aortic syndrome occurred. CONCLUSIONS: Transapical TAVI is a safe method and shows very promising early and mid-term outcomes, without early/late aortic syndrome, in patients with aortic diseases for whom transfemoral TAVI as the first-line transcatheter method might be contraindicated or not feasible.


Assuntos
Doenças da Aorta , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Fatores de Tempo , Resultado do Tratamento
2.
J Card Surg ; 36(2): 610-617, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33386755

RESUMO

OBJECTIVES: Little data have been published on the midterm effect of transapical/transfemoral-transcatheter aortic valve replacement (TA-/TF-TAVR) using the Edwards SAPIEN 3 valve (S3). We aimed to compare the outcomes after TA-/TF-TAVR utilizing the S3 (TA-/TF-S3) valve with those after surgical aortic valve replacement utilizing the rapid deployment Edwards INTUITY valve (RD-SAVR). METHODS: Between March 2012 and April 2018, 122 patients with aortic stenosis underwent TA-S3, 77 patients underwent TF-S3 and 182 patients underwent RD-SAVR through partial sternotomy at our institution. We conducted clinical and echocardiographic midterm follow-ups. The primary outcomes of the study were the incidence of new pacemakers permanent pacemaker implantation (PPI), the occurrence of paravalvular leakage (PVL) and the hemodynamic performance of the valves. RESULTS: All study groups were at intermediate surgical risk. The 30-day all-cause mortality and stroke rates in the TA-S3, TF-S3, and RD-SAVR groups were 4.1% and 1.6%, 3.9% and 2.6%, and 3.8% and 2.2%, respectively. The RD-SAVR group had significantly smaller PVL and PPI rates than did the TA-/TF-S3 group (p < .0001). At the discharge, the one-year postprocedure mean gradients were 9 ± 5.1/10 ± 4.5 mmHg, 11 ± 4.1/12 ± 3.8 mmHg, and 10.1 ± 4.3/10.4 ± 2.6 mmHg in the TA-S3, TF-S3, and RD-SAVR groups, respectively. Midterm valve thrombosis, Re-TAVR/SVAR were low and similar among the study groups, whereas endocarditis was higher in the TAVR group. CONCLUSION: RD-SAVR was superior to TA-/TF-S3 in the PVL and PPI rates. We observed similar early outcomes and valve hemodynamics. The endocarditis was higher in the TAVR group.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Fatores de Risco , Resultado do Tratamento
3.
J Cardiovasc Surg (Torino) ; 62(6): 609-617, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35037446

RESUMO

BACKGROUND: Scarcely any data has been published on the mid-term effect of transapical-transcatheter aortic valve implantation (TA-TAVI) using the Edwards SAPIEN 3 valve (S3; Edwards Lifesciences Corp., Irvine, CA, USA). We present mid-term clinical and echocardiographic outcomes after TA-TAVI utilizing S3. METHODS: Between 02/2014-06/2017, 122 elderly patients with severe aortic stenosis underwent TA-TAVI utilizing S3 at our institution. We conducted clinical and echocardiographic follow-up. The mean follow-up was 15 months. All end-point-related outcomes were adjudicated according to Valve Academic Research Consortium-2 definitions. RESULTS: The STS-score of the entire cohort was 6.26±4.6. More than one-third of the patients exhibited severe peripheral artery disease. The 30-d all-cause mortality, all-stroke rate, and myocardial infarction of the entire cohort were 4.1%, 1.6%, and 0.8% respectively. Median survival time of the entire cohort was 35 months. The cumulative mid-term myocardial infarction and stroke rate was 2.6% and 3.5%, respectively. The postoperative moderate/severe paravalvular leakage occurred in 1.6% of cases. At discharge, one-year and two-year postprocedure peak/mean gradients were 16.6±8.3/ 9±5.1 mmHg, 18±6.9/ 10±4.5 mmHg, and 22.2±5.4/ 12.8±4.6 mmHg, respectively. The rate of new pacemaker cases was 14.1%. Acute kidney injury network 2/3 appears, as an independent predictor of mortality. CONCLUSIONS: We observed very promising early and mid-term clinical outcomes with a high degree of device success and good hemodynamic performance after TA-TAVI using the S3 in the intermediate risk patient profile.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Feminino , Hemodinâmica , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA