1.
Am J Ind Med ; 61(3): 251-260, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29125194

RESUMO

Unmasking of latent neurodegenerative disease has been reported following exposure to chemicals that share one or more mechanisms of action in common with those implicated in the specific disease. For example, unmasking of latent Parkinson's disease (PD) has been associated with exposure to anti-dopaminergic agents, while the progression of pre-existing mild cognitive impairment and unmasking of latent Alzheimer's disease has been associated with exposure to general anesthetic agents which promote Aß protein aggregation. This literature review and clinical case report about a 45-year-old man with no family history of motor neuron disease who developed overt symptoms of a neuromuscular disorder in close temporal association with his unwitting occupational exposure to volatile organic compounds (VOCs) puts forth the hypothesis that exposure to VOCs such as toluene, which disrupt motor function and increase oxidative stress, can unmask latent ALS type neuromuscular disorder in susceptible individuals.


Assuntos
Esclerose Lateral Amiotrófica , Exposição Ocupacional , Solventes , Tolueno , Compostos Orgânicos Voláteis , Idade de Início , Humanos , Masculino , Pessoa de Meia-Idade , Estresse Oxidativo
2.
Int J Occup Environ Health ; 16(3): 279-90, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20662420

RESUMO

Several studies were designed and conducted to evaluate amphibole asbestos exposures in homes containing Zonolite (expanded vermiculite) attic insulation (ZAI). A range of tasks selected for evaluation included cleaning, working around, moving, and removal of ZAI in attics and living spaces. The fieldwork for these studies was conducted at two homes in Spokane, WA and one home in Silver Spring, MD. Personal and area air samples were collected and analyzed as part of the exposure studies. Surface dust samples and bulk samples were also collected and analyzed. The results demonstrated that airborne concentrations of amphibole asbestos were not elevated if the material is undisturbed. The results also demonstrated that cleaning, remodeling, and other activities did produce significant concentrations of airborne amphibole asbestos when the ZAI was disturbed.


Assuntos
Poluentes Ocupacionais do Ar/análise , Silicatos de Alumínio/análise , Amiantos Anfibólicos/análise , Exposição Ocupacional/análise , Habitação , Humanos , Local de Trabalho
3.
J Occup Environ Hyg ; 2(8): 375-82, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16080259

RESUMO

The work reported here evaluates the effectiveness of various rates of dilution ventilation in controlling welder exposures to manganese in shielded metal arc welding (SMAW) fume when working in enclosed or restricted spaces. Personal and area monitoring using total and respirable sampling techniques, along with multiple analytical techniques, was conducted during the welding operations. With 2000 cubic feet per minute (CFM) (56.63 m3/min) dilution ventilation, personal breathing zone concentrations for the welder using 1/8 inches (3.18 mm) E6010 and E7018 mild steel electrodes were within 75% of the existing threshold limit value (TLV of 0.2 mg/m3 for total manganese and were five times greater than the 2001-2003 proposed respirable manganese TLV of 0.03 mg/m3. Manganese concentrations using high manganese content electrodes were five times greater than those for E6010 and E7018 electrodes. Area samples upstream and downstream of the welder using E6010 and E7018 electrodes exceeded 0.2 mg/m3 manganese. Concentrations inside and outside the welding helmet do not indicate diversion of welding fume by the welding helmet from the welder's breathing zone. There was close agreement between respirable manganese and total manganese fume concentrations. Total fume concentrations measured by gravimetric analysis of matched-weight, mixed cellulose ester filters were comparable to those measured via preweighed PVC filter media. This study indicates that 2000 CFM general dilution ventilation per 29 CFR 1910.252 (c)(2) may not be a sufficient means of controlling respirable manganese exposures for either welders or their helpers in restricted or enclosed spaces. In the absence of site-specific monitoring data indicating otherwise, it is prudent to employ respiratory protection or source capture ventilation for SMAW with E6010, E7018, and high manganese content electrodes rather than depending solely on 2000 CFM general dilution ventilation in enclosed spaces.


Assuntos
Espaços Confinados , Manganês/análise , Exposição Ocupacional/análise , Soldagem/métodos , Monitoramento Ambiental/métodos , Dispositivos de Proteção da Cabeça , Humanos , Exposição por Inalação/análise , Exposição por Inalação/prevenção & controle , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/normas , Níveis Máximos Permitidos , Ventilação/métodos , Ventilação/normas