Materials (Basel) ; 14(12)2021 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-34205381

RESUMO

Various orthodontic wire compositions and configurations are present on the market for removable appliances; however, there have still been only few studies focusing on the effect of resin color and additives such as glitter on corrosion of metallic wires under different conditions. Thus, the aim of the study was to compare concentrations of released ions (aluminium, chromium, nickel) in a corrosive medium under three different conditions: non-loaded wires, loaded wires, and non-loaded wires treated with Kukis® cleaning tablets. Six different wires made of three types of steel alloy were embedded in PMMA resin leaving one centimetre of each wire emerging from the resin to come into contact with the corrosive medium. Glitter particles were added to half of the produced test specimens. For the unloaded test series, five specimens of each group were covered in a petri dish with 50 mL of corrosive medium (pH 2.3) following EN-ISO 10271 for seven days at 37 °C. The wires for the mechanically loaded test specimens overlapped the resin by 5 cm and were clamped into a time-switched electric drive for a defined period of time before the samples were taken after a testing time of 7 days. In the third group, unloaded test specimens were transferred from their petri dishes into the prepared Kukis® solution every 24 h before being stored in the corrosive medium. Inductively coupled plasma mass spectrometry (ICP-MS) was used to quantify the specific ions in the corrosive solution. Statistical analysis showed that the mechanical loading of all wires could significantly raise the diffusion of ions into the corrosive medium. The colour of the resin did not affect the concentration of the released ions. The Kukis® cleaning tabs could not lower the corrosion of the tested metals, as some of the wires were corroded even more using the brace cleanser. Glitter-containing test specimens showed significantly higher amounts of aluminium. Mechanical loading as well as the presence of glitter particles in the resin significantly affected ion concentrations.

2.
Artigo em Alemão | MEDLINE | ID: mdl-34115152

RESUMO

BACKGROUND AND AIM: In order to support children's compliance with orthodontic treatment, glitter particles containing aluminium (Al) are often embedded in the acrylic of removable appliances. When worn for up to 16 h daily for 2-3 years, it can be assumed that Al ions diffuse into saliva over time. The aim of this study was to investigate the release of Al ions from the acrylic using different orthodontic wires. MATERIALS AND METHOD: Test specimens (surface area 5.65 cm2) were prepared from orthodontic resin and various wires; half contained aluminium glitter particles. The test specimens were placed in Petri dishes containing 50 ml of corrosion medium (pH 2.3) according to DIN EN ISO 10271 at 37 °C for 7 days. Inductively coupled plasma mass spectrometry (ICP-MS) was used to quantify the specific ions in the corrosion solution. RESULTS: Statistical analysis showed a significant difference in the concentration of Al ions between samples with and without glitter particles. Concentrations from samples with glitter reached up to 14,474 µg/l Al ions; samples without glitter contained on average 1260 µg/l. A small proportion of the Al ions may originate from the alloys of the wires. CONCLUSIONS: It should be investigated whether the aluminium concentration can lead to health risks for humans. In view of the findings, orthodontists should not offer appliances containing glitter in order to minimize aluminium uptake with saliva. It needs to be clarified whether the conditions found in the oral cavity lead to the same results as under the abovementioned conditions. Legislation should be developed to limit the release of aluminium from orthodontic products.


Assuntos
Alumínio , Aparelhos Ortodônticos Removíveis , Criança , Corrosão , Alemanha , Humanos , Teste de Materiais , Fios Ortodônticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...