Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Dent ; 90: 103208, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31600534

RESUMO

OBJECTIVE: To develop experimental light-cured (L) and dual-cured (D) resin cements containing N-(2-hydroxyethyl)acrylamide and evaluate the physicochemical and optical properties. METHODS: Experimental resin cements were formulated using bisphenol A-glycidyl dimethacrylate (70%) and 2-hydroxyethyl methacrylate (30%), in the control groups, and, bisphenol A-glycidyl dimethacrylate (70%) and N-(2-hydroxyethyl)acrylamide (30%). Polymerization kinetics were evaluated by differential scanning calorimetry (n = 3), softening in solvent (ΔKHN) evaluated by the difference of Knoop microhardness before (KHN1) and after (KHN2) ethanol solution immersion (n = 5), radiopacity in mmAl (n = 5), film thickness (n = 3) and color stability were evaluated. Mechanical properties as ultimate tensile strength (UTS) and micro-shear bond strength (µSBS) were analyzed immediately and after 6 months. Results were analyzed using ANOVA, Tukey's test and Student's t-test (α = 0.050). RESULTS: The LHEAA1 group had no statistical difference from the control group regarding polymerization kinetics, KHN1, ΔKHN and color stability (p > 0.050). In dual-cured cements, the acrylamide groups presented a lower degree of conversion and higher ΔKHN than the DHEMA0.6 group, which obtained a higher rate of polymerization (p < 0.050). There was no statistical difference in radiopacity and film thickness (p > 0.050). Dual-cured cements with N-(2-hydroxyethyl)acrylamide showed higher color change than methacrylates. Immediate mechanical properties were lower for acrylamide groups (p < 0.050), with higher hydrolytic stability. CONCLUSIONS: The addition of N-(2-hydroxyethyl)acrylamide negatively affected the properties of the dual-cured resin cements. LHEAA1 did not differ in physicochemical and optical properties from the control, with higher hydrolytic stability. CLINICAL SIGNIFICANCE: The results of the study indicate that acrylamides increased mechanical properties over time independently of the curing system mode, with more hydrolytic stability. The clinical performance of experimental resin cements should be evaluated.


Assuntos
Bis-Fenol A-Glicidil Metacrilato/química , Materiais Dentários/química , Cimentos de Resina/química , Acrilamidas , Colagem Dentária , Humanos , Teste de Materiais , Polimerização
2.
J Prosthodont Res ; 63(4): 389-395, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31303569

RESUMO

PURPOSE: This systematic review and meta-analysis aimed to evaluate the difference in longevity of tooth-supported ceramic prostheses designed by conventional and computer-aided design/computer-aided manufacturing (CAD/CAM) techniques. STUDY SELECTION: Two reviewers searched the Web of Science, PubMed, SCOPUS and LILACS databases between 1966 and October 2017. Clinical studies that compared the survival rate of CAD/CAM against conventional restorations were included. RESULTS: Eleven randomized controlled trials and three prospective studies were included, n=14. Three types of tooth-supported restorations were searched in the included studies: single crown, multiple-unit and partial ceramic crown. The follow-up of patients in the studies ranged from 24 to 84 months. A total of 1209 restorations had been placed in 957 patients in the included trials, and failures were analyzed by type and material restoration. From a total of 72 restoration failures, the CAD/CAM system resulted in a 1.84 (IC95%: 1.28-2.63) higher risk than conventional manufacturing of ceramic restoration. Nevertheless, when drop-outs were included as a failure risk, the CAD/CAM system resulted in a risk of 1.32 (IC95%: 1.10-1.58). Multilevel analysis of tooth-supported ceramic restorations, considering drop-outs as successes, resulted in rates of 1.48 and 2.62 failures per 100 restoration-years for the controls and CAD/CAM groups, respectively. Considering drop-outs as failures, we found rates of 4.23 and 5.88 failures per 100 restoration-years for the controls and CAD/CAM groups, respectively. CONCLUSIONS: The meta-analysis results suggest that the longevity of a tooth-supported ceramic prostheses made by CAD/CAM manufacturing is lower than that of crowns mad by the conventional technique.


Assuntos
Desenho Assistido por Computador , Planejamento de Prótese Dentária , Cerâmica , Coroas , Porcelana Dentária , Humanos , Estudos Prospectivos
3.
Braz Oral Res ; 31: e31, 2017 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-28513783

RESUMO

The aim of this study was to develop an experimental adhesive with addition of [2-(methacryloyloxy)ethyl]trimethylammonium chloride (METAC) and to evaluate its mechanical and biological properties and its in vitro antibacterial activity. An experimental adhesive resin was formulated with Bis-GMA, TEGDMA, and HEMA. The antibacterial monomer was added at concentrations of 1%, 2.5%, and 5% (METAC groups). A group without METAC addition was used as control. The experimental adhesives were evaluated as to their antibacterial potential against Streptococcus mutans, degree of conversion, and softening in ethanol for 2 hours. The data were analyzed by one-way ANOVA, Tukey's post-hoc test, and the paired Student's t-test (significance level of 0.05). METAC showed antibacterial activity against S. mutans at all concentrations (p < 0.05). There was no statistical difference across METAC groups (p > 0.05). The 1%, 2.5%, and 5% groups yielded the highest mean values for degree of conversion (p < 0.05). The 1% group did not differ from the control group (p > 0.05). There was no statistical difference in baseline microhardness values (p > 0.05) and microhardness values after immersion in ethanol were lower than at baseline for all groups (p < 0.05). There was no statistical difference in the reduction of Knoop hardness number (KHN) after immersion in ethanol for any of the groups (p > 0.05). The results of the present study indicate that METAC is a promising antibacterial agent when added to an adhesive system.


Assuntos
Antibacterianos/química , Bis-Fenol A-Glicidil Metacrilato/química , Resinas Compostas/química , Metacrilatos/química , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Análise de Variância , Antibacterianos/farmacologia , Bis-Fenol A-Glicidil Metacrilato/farmacologia , Contagem de Colônia Microbiana , Resinas Compostas/farmacologia , Testes de Dureza , Imersão , Teste de Materiais , Metacrilatos/farmacologia , Transição de Fase , Polietilenoglicóis/farmacologia , Polimerização , Ácidos Polimetacrílicos/farmacologia , Reprodutibilidade dos Testes , Streptococcus mutans/efeitos dos fármacos
4.
Braz. oral res. (Online) ; 31: e31, 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-839505

RESUMO

Abstract The aim of this study was to develop an experimental adhesive with addition of [2-(methacryloyloxy)ethyl]trimethylammonium chloride (METAC) and to evaluate its mechanical and biological properties and its in vitro antibacterial activity. An experimental adhesive resin was formulated with Bis-GMA, TEGDMA, and HEMA. The antibacterial monomer was added at concentrations of 1%, 2.5%, and 5% (METAC groups). A group without METAC addition was used as control. The experimental adhesives were evaluated as to their antibacterial potential against Streptococcus mutans, degree of conversion, and softening in ethanol for 2 hours. The data were analyzed by one-way ANOVA, Tukey’s post-hoc test, and the paired Student’s t-test (significance level of 0.05). METAC showed antibacterial activity against S. mutans at all concentrations (p < 0.05). There was no statistical difference across METAC groups (p > 0.05). The 1%, 2.5%, and 5% groups yielded the highest mean values for degree of conversion (p < 0.05). The 1% group did not differ from the control group (p > 0.05). There was no statistical difference in baseline microhardness values (p > 0.05) and microhardness values after immersion in ethanol were lower than at baseline for all groups (p < 0.05). There was no statistical difference in the reduction of Knoop hardness number (KHN) after immersion in ethanol for any of the groups (p > 0.05). The results of the present study indicate that METAC is a promising antibacterial agent when added to an adhesive system.


Assuntos
Antibacterianos/química , Bis-Fenol A-Glicidil Metacrilato/química , Resinas Compostas/química , Metacrilatos/química , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Análise de Variância , Antibacterianos/farmacologia , Bis-Fenol A-Glicidil Metacrilato/farmacologia , Contagem de Colônia Microbiana , Resinas Compostas/farmacologia , Testes de Dureza , Imersão , Teste de Materiais , Metacrilatos/farmacologia , Transição de Fase , Polietilenoglicóis/farmacologia , Polimerização , Ácidos Polimetacrílicos/farmacologia , Reprodutibilidade dos Testes , Streptococcus mutans/efeitos dos fármacos
5.
Braz. j. oral sci ; 14(3): 246-250, July-Sept. 2015. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-770528

RESUMO

Abstract Aim: To evaluate the long-term post push-out bond strength to dentin, water sorption, solubility and swelling of conventional and self-adhesive dual-cure resin cements. Methods: Forty-eight bovine roots were prepared for fiber post cementation with RelyX ARC and RelyX U100. According to resin cement and storage time (24 h and 6 months), 4 groups were assessed using the push-out test. Water sorption and solubility were performed according to ISO 4049:2009. The swelling coefficient was obtained using cement disks of each material immersed in distilled water until the swelling equilibrium was reached. The mass of dry and swelled polymer and solvent density were used to calculate the coefficient. Statistical data analysis was performed using Student's t-test for water sorption, solubility and swelling coefficient and the Kruskal-Wallis and Dunn multiple comparison tests for push-out analysis with a significance level of 0.05. Results: The immediate bond strength was not significantly different between RelyX ARC (3.09 MPa) and RelyX U100 (3.78 MPa) (p>0.05). RelyX U100 showed higher (p<0.05) bond strength after six months of storage (9.60 MPa) than RelyX ARC (6.65 MPa). The water sorption and solubility values were not significantly different (p>0.05) between groups. The swelling coefficient of the RelyX U100 group was significantly higher than that of the RelyX ARC group (p<0.05). Conclusions: RelyX U100 resin cement showed a higher swelling coefficient than RelyX ARC, and the longitudinal push-out bond strength increased after six months. Clinical significance: The clinical longevity of restorative treatment in root-filled teeth is dependent on the long-term properties and behavior of the cement used for post luting. Results of this study suggest that the selfadhesive resin cement may be a reliable alternative.


Assuntos
Animais , Bovinos , Solubilidade , Armazenamento de Água , Adesivos Dentinários , Cimentos de Resina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...