Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Gynecol Oncol ; 145(1): 102-107, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28169006

RESUMO

OBJECTIVE: To analyze the changes in the composition of the gynecologic oncology inpatient ward following the implementation of a robotic surgery program and its impact on inpatient resource utilization and costs. METHODS: Retrospective review of the medical charts of patients admitted onto the gynecologic oncology ward the year prior to and five years after the implementation of robotics. The following variables were collected: patient characteristics, hospitalization details (reason for admission and length of hospital stay), and resource utilization (number of hospitalization days, consultations, and imaging). RESULTS: Following the introduction of robotic surgery, there were more admissions for elective surgery yet these accounted for only 21% of the inpatient ward in terms of number of hospital days, compared to 36% prior to the robotic program. This coincided with a sharp increase in the overall number of patients operated on by a minimally invasive approach (15% to 76%, p<0.0001). The cost per surgical admission on the inpatient ward decreased by 59% ($9827 vs. $4058) in the robotics era. The robotics program contributed to a ward with higher proportion of patients with complex comorbidities (Charlson≥5: RR 1.06), Stage IV disease (RR 1.30), and recurrent disease (RR 1.99). CONCLUSION: Introduction of robotic surgery allowed for more patients to be treated surgically while simultaneously decreasing inpatient resource use. With more patients with non-surgical oncological issues and greater medical complexity, the gynecologic oncology ward functions more like a medical rather than surgical ward after the introduction of robotics, which has implications for hospital-wide resource planning.


Assuntos
Neoplasias dos Genitais Femininos/cirurgia , Procedimentos Cirúrgicos em Ginecologia , Hospitalização/tendências , Tempo de Internação/tendências , Encaminhamento e Consulta/tendências , Procedimentos Cirúrgicos Robóticos , Adulto , Idoso , Ascite/epidemiologia , Neutropenia Febril Induzida por Quimioterapia/epidemiologia , Feminino , Neoplasias dos Genitais Femininos/diagnóstico por imagem , Recursos em Saúde , Custos Hospitalares/tendências , Hospitalização/economia , Humanos , Obstrução Intestinal/epidemiologia , Tempo de Internação/economia , Imageamento por Ressonância Magnética/economia , Imageamento por Ressonância Magnética/tendências , Pessoa de Meia-Idade , Derrame Pleural/epidemiologia , Pneumonia/epidemiologia , Tomografia por Emissão de Pósitrons/economia , Tomografia por Emissão de Pósitrons/tendências , Radiografia/economia , Radiografia/tendências , Radiologia Intervencionista/economia , Radiologia Intervencionista/tendências , Encaminhamento e Consulta/economia , Estudos Retrospectivos , Robótica , Sepse/epidemiologia , Infecção da Ferida Cirúrgica/epidemiologia , Tomografia Computadorizada por Raios X/economia , Tomografia Computadorizada por Raios X/tendências , Infecções Urinárias/epidemiologia
2.
Med Phys ; 38(9): 5119-29, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21978057

RESUMO

PURPOSE: The authors applied 2D reference dosimetry protocol for dose measurements using XR-QA radiochromic film model during diagnostic computed tomography (CT) examinations carried out on patients and humanoid Rando phantom. METHODS: Response of XR-QA model GAFCHROMIC™ film reference dosimetry system was calibrated in terms of Air-Kerma in air. Four most commonly used CT protocols were selected on their CT scanner (GE Lightspeed VCT 64), covering three anatomical sites (head, chest, and abdomen). For each protocol, 25 patients ongoing planned diagnostic CT examination were recruited. Surface dose was measured using four or eight film strips taped on patients' skin and on Rando phantom. Film pieces were scanned prior to and after irradiation using Epson Expression™ 10000XL document scanner. Optical reflectance of the unexposed film piece was subtracted from exposed one to obtain final net reflectance change, which is subsequently converted to dose using previously established calibration curves. RESULTS: The authors' measurements show that body skin dose variation has a sinusoidal pattern along the scanning axis due to the helical movement of the x-ray tube, and a comb pattern for head dose measurements due to its axial movement. Results show that the mean skin dose at anterior position for patients is (51 ± 6) mGy, (29 ± 11) mGy, (45 ± 13) mGy and (38 ± 20) mGy for head, abdomen, angio Abdomen, and chest and abdomen protocol (UP position), respectively. The obtained experimental dose length products (DLP) show higher values than CT based DLP taken from the scanner console for body protocols, but lower values for the head protocol. Internal dose measurements inside the phantom's head indicate nonuniformity of dose distribution within scanned volume. CONCLUSIONS: In this work, the authors applied an Air-Kerma in air based radiochromic film reference dosimetry protocol for in vivo skin dose measurements. In this work, they employed green channel extracted from the scanned RGB image for dose measurements in the range from 0 to 200 mGy. Measured skin doses and corresponding DLPs were higher than DLPs provided by the CT scanner manufacturer as they were measured on patients' skin.


Assuntos
Dosimetria Fotográfica/métodos , Dosimetria Fotográfica/normas , Tomografia Computadorizada por Raios X/métodos , Calibragem , Humanos , Imagens de Fantasmas , Doses de Radiação , Padrões de Referência , Incerteza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...