Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Opt Express ; 11(1): 8-26, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32010496

RESUMO

"How thick is your light sheet?" is a question that has been asked frequently after talks showing impressive renderings of 3D data acquired by a light-sheet microscope. This question is motivated by the fact that most of the time the thickness of the light-sheet is uniquely associated to the axial resolution of the microscope. However, the link between light-sheet thickness and axial resolution has never been systematically assessed and it is still unclear how both are connected. The question is not trivial because commonly employed measures cannot readily be applied or do not lead to easily interpretable results for the many different types of light sheet. Here, we introduce a set of intuitive measures that helps to define the relationship between light sheet thickness and axial resolution by using simulation data. Unexpectedly, our analysis revealed a trade-off between better axial resolution and thinner light-sheet thickness. Our results are surprising because thicker light-sheets that provide lower image contrast have previously not been associated with better axial resolution. We conclude that classical Gaussian illumination beams should be used when image contrast is most important, and more advanced types of illumination represent a way to optimize axial resolution at the expense of image contrast.

2.
Nat Commun ; 6: 7990, 2015 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-26329685

RESUMO

To study the development and interactions of cells and tissues, multiple fluorescent markers need to be imaged efficiently in a single living organism. Instead of acquiring individual colours sequentially with filters, we created a platform based on line-scanning light sheet microscopy to record the entire spectrum for each pixel in a three-dimensional volume. We evaluated data sets with varying spectral sampling and determined the optimal channel width to be around 5 nm. With the help of these data sets, we show that our setup outperforms filter-based approaches with regard to image quality and discrimination of fluorophores. By spectral unmixing we resolved overlapping fluorophores with up to nanometre resolution and removed autofluorescence in zebrafish and fruit fly embryos.


Assuntos
Drosophila melanogaster , Embrião não Mamífero , Microscopia de Fluorescência/métodos , Peixe-Zebra , Animais , Corantes Fluorescentes , Processamento de Imagem Assistida por Computador , Organismos Geneticamente Modificados
3.
Nat Methods ; 11(9): 919-22, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25042787

RESUMO

The heart's continuous motion makes it difficult to capture high-resolution images of this organ in vivo. We developed tools based on high-speed selective plane illumination microscopy (SPIM), offering pristine views into the beating zebrafish heart. We captured three-dimensional cardiac dynamics with postacquisition synchronization of multiview movie stacks, obtained static high-resolution reconstructions by briefly stopping the heart with optogenetics and resolved nonperiodic phenomena by high-speed volume scanning with a liquid lens.


Assuntos
Rastreamento de Células/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Microscopia de Vídeo/métodos , Miócitos Cardíacos/citologia , Peixe-Zebra/anatomia & histologia , Algoritmos , Animais , Miócitos Cardíacos/fisiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração , Peixe-Zebra/fisiologia
4.
Opt Express ; 21(18): 21010-26, 2013 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-24103973

RESUMO

The in-vivo investigation of highly dynamic biological samples, for example the beating zebrafish heart, requires high-speed volume imaging techniques. Light-sheet microscopy is ideal for such samples as it records high-contrast images of entire planes within large samples at once. However, in order to obtain images of different planes, it has been necessary to move the sample relative to the fixed focal plane of the detection objective lens. This mechanical movement limits speed, precision and may be harmful to the sample. We have built a light-sheet microscope that uses remote focusing with an electrically tunable lens (ETL). Without moving specimen or objective we have thereby achieved flexible volume imaging at much higher speeds than previously reported. Our high-speed microscope delivers 3D snapshots of sensitive biological samples. As an example, we imaged 17 planes within a beating zebrafish heart at 510 frames per second, equivalent to 30 volume scans per second. Movements, shape changes and signals across the entire volume can be followed which has been impossible with existing reconstruction techniques.


Assuntos
Imageamento Tridimensional/instrumentação , Lentes , Microscopia/instrumentação , Animais , Calibragem , Coração/anatomia & histologia , Processamento de Sinais Assistido por Computador , Peixe-Zebra/anatomia & histologia
5.
Opt Express ; 21(11): 13824-39, 2013 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-23736637

RESUMO

In this study we show that it is possible to successfully combine the benefits of light-sheet microscopy, self-reconstructing Bessel beams and two-photon fluorescence excitation to improve imaging in large, scattering media such as cancer cell clusters. We achieved a nearly two-fold increase in axial image resolution and 5-10 fold increase in contrast relative to linear excitation with Bessel beams. The light-sheet penetration depth could be increased by a factor of 3-5 relative to linear excitation with Gaussian beams. These finding arise from both experiments and computer simulations. In addition, we provide a theoretical description of how these results are composed. We investigated the change of image quality along the propagation direction of the illumination beams both for clusters of spheres and tumor multicellular spheroids. The results reveal that light-sheets generated by pulsed near-infrared Bessel beams and two photon excitation provide the best image resolution, contrast at both a minimum amount of artifacts and signal degradation along the propagation of the beam into the sample.

6.
Opt Express ; 21(9): 11425-40, 2013 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-23669999

RESUMO

One of main challenges in light-sheet microscopy is to design the light-sheet as extended and thin as possible--extended to cover a large field of view, thin to optimize resolution and contrast. However, a decrease of the beam's waist also decreases the illumination beam's depth of field. Here, we introduce a new kind of beam that we call sectioned Bessel beam. These beams can be generated by blocking opposite sections of the beam's angular spectrum. In combination with confocal-line detection the optical sectioning performance of the light-sheet can be decoupled from the depth of field of the illumination beam. By simulations and experiments we demonstrate that these beams exhibit self-reconstruction capabilities and penetration depths into thick scattering media equal to those of conventional Bessel beams. We applied sectioned Bessel beams to illuminate tumor multicellular spheroids and prove the increase in contrast. Sectioned Bessel beams turn out to be highly advantageous for the investigation of large strongly scattering samples in a light-sheet microscope.


Assuntos
Aumento da Imagem/instrumentação , Iluminação/instrumentação , Microscopia/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
7.
Nat Commun ; 3: 632, 2012 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-22252556

RESUMO

Laser beams that can self-reconstruct their initial beam profile even in the presence of massive phase perturbations are able to propagate deeper into inhomogeneous media. This ability has crucial advantages for light sheet-based microscopy in thick media, such as cell clusters, embryos, skin or brain tissue or plants, as well as scattering synthetic materials. A ring system around the central intensity maximum of a Bessel beam enables its self-reconstruction, but at the same time illuminates out-of-focus regions and deteriorates image contrast. Here we present a detection method that minimizes the negative effect of the ring system. The beam's propagation stability along one straight line enables the use of a confocal line principle, resulting in a significant increase in image contrast. The axial resolution could be improved by nearly 100% relative to the standard light-sheet techniques using scanned Gaussian beams, while demonstrating self-reconstruction also for high propagation depths.

8.
Opt Express ; 18(23): 24229-44, 2010 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-21164769

RESUMO

We recently demonstrated that Microscopy with Self-Reconstructing Beams (MISERB) increases both image quality and penetration depth of illumination beams in strongly scattering media. Based on the concept of line scanned light-sheet microscopy, we present an add-on module to a standard inverted microscope using a scanned beam that is shaped in phase and amplitude by a spatial light modulator. We explain technical details of the setup as well as of the holograms for the creation, positioning and scaling of static light-sheets, Gaussian beams and Bessel beams. The comparison of images from identical sample areas illuminated by different beams allows a precise assessment of the interconnection between beam shape and image quality. The superior propagation ability of Bessel beams through inhomogeneous media is demonstrated by measurements on various scattering media.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...