Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Hum Immunol ; 84(8): 359-365, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37169599

RESUMO

Human amnion epithelial cells (hAEC) can be efficiently isolated from full-term amnion membrane and have been gaining recognition as advanced medical products. Such cells originate directly from the embryo during the early phase of development and exert a crucial function in the establishment of a tolerogenic environment, to avoid maternal immune rejection. Amnion cell immuno-modulation may be exploited, but additional efforts are required to establish the mechanisms underlying such capacity. The way to fully clarify such an issue is so far long. Here we overview current knowledge on the effects on innate or adaptive immune cells offered by intact hAEC or secreted mediators, pinpointing the mechanisms to date elucidated by our group and others. We move from the description of hAEC general features to molecular intermediaries generating effects directly or indirectly on immune cells. We focus on the role of non-canonical HLA class I molecules, with emphasis on HLA-G, but expand such analysis on adenosinergic mediators, cytokines, and hAEC-derived microvesicles. Finally, we report the ongoing clinical trials exploiting hAEC multipotency and immune modulation.


Assuntos
Células Epiteliais , Antígenos HLA-G , Humanos , Âmnio , Células Cultivadas , Citocinas
2.
Oncoimmunology ; 7(8): e1458809, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30221054

RESUMO

Multiple myeloma (MM) derives from malignant transformation of plasma cells (PC), which accumulate in the bone marrow (BM), where microenvironment supports tumor growth and inhibits anti-tumor immune responses. Adenosine (ADO), an immunosuppressive molecule, is produced within MM patients' BM by adenosinergic ectoenzymes, starting from ATP (CD39/CD73) or NAD+ [CD38/CD203a(PC-1)/CD73]. These ectoenzymes form a discontinuous network expressed by different BM cells. We investigated the expression and function of ectoenzymes on microvesicles (MVs) isolated from BM plasma samples of patients with MM, using asymptomatic forms of monoclonal gammopathy of undetermined significance (MGUS) and smoldering MM (SMM) as controls. The percentage of MVs expressing ectoenzymes at high levels was higher when derived from MM patients than controls. BM CD138+ PC from MM patients expressed high levels of all ectoenzymes. Paired MVs samples confirmed a higher percentage of MVs with high ectoenzymes expression in MM patients than controls. Pooled MVs from MM patients or controls were tested for ADO production. The catabolism of ATP, NAD+, ADPR and AMP to ADO was higher in MVs from MM patients than in those from controls. In conclusion, our results confirmed the hypothesis that MVs in MM niche are main contributor of ADO production. The ability of MVs to reach biological fluids strongly support the view that MVs may assume diagnostic and pathogenetic roles.

3.
Auton Neurosci ; 178(1-2): 50-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23664242

RESUMO

Seismocardiogram (SCG) is the measure of the micro-vibrations produced by the heart contraction and blood ejection into the vascular tree. Over time, a large body of evidence has been collected on the ability of SCG to reflect cardiac mechanical events such as opening and closure of mitral and aortic valves, atrial filling and point of maximal aortic blood ejection. We recently developed a smart garment, named MagIC-SCG, that allows the monitoring of SCG, electrocardiogram (ECG) and respiration out of the laboratory setting in ambulant subjects. The present pilot study illustrates the results of two different experiments performed to obtain a first evaluation on whether a dynamical assessment of indexes of cardiac mechanics can be obtained from SCG recordings obtained by MagIC-SCG. In the first experiment, we evaluated the consistency of the estimates of two indexes of cardiac contractility, the pre-ejection period, PEP, and the left ventricular ejection time, LVET. This was done in the lab, by reproducing an experimental protocol well known in literature, so that our measures derived from SCG could have been compared with PEP and LVET reference values obtained by traditional techniques. Six healthy subjects worn MagIC-SCG while assuming two different postures (supine and standing); PEP was estimated as the time interval between the Q wave in ECG and the SCG wave corresponding to the opening of aortic valve; LVET was the time interval between the SCG waves corresponding to the opening and closure of the aortic valve. The shift from supine to standing posture produced a significant increase in PEP and PEP/LVET ratio, a reduction in LVET and a concomitant rise in the LF/HF ratio in the RR interval (RRI) power spectrum. These results are in line with data available in literature thus providing a first support to the validity of our estimates. In the second experiment, we evaluated in one subject the feasibility of the beat-by-beat assessment of LVET during spontaneous behavior. The subject was continuously monitored by the smart garment from 8 am to 8 pm during a workday. From the whole recording, three data segments were selected: while the subject was traveling to work (M1), during work in the office (O) and while traveling back home (M2). LVET was estimated on a beat-by-beat basis from SCG and the RRI influence was removed by regression analysis. The LVET series displayed marked beat-by-beat fluctuations at the respiratory frequency. The amplitude of these fluctuations changed in the three periods and was lower when the LF/HF RRI power ratio was higher, at O, thus suggesting a possible influence of the autonomic nervous system on LVET short-term variability. To the best of our knowledge this case report provides for the first time a representation of the beat-by-beat dynamics of a systolic time interval during daily activity. The statistical characterization of these findings remains to be explored on a larger population.


Assuntos
Balistocardiografia/instrumentação , Balistocardiografia/métodos , Eletrocardiografia Ambulatorial/instrumentação , Frequência Cardíaca/fisiologia , Contração Miocárdica/fisiologia , Processamento de Sinais Assistido por Computador/instrumentação , Aceleração , Adulto , Ambulâncias , Feminino , Humanos , Masculino , Pletismografia , Postura/fisiologia , Tecnologia sem Fio
4.
Methods Inf Med ; 49(5): 521-5, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20582387

RESUMO

OBJECTIVES: To investigate the effects of hypoxia during sleep on linear and self-similar components of heart rate variability (HRV) in eight healthy subjects at high altitude on Mount Everest. METHODS: ECG was monitored by using an innovative textile-based device, the MagIC system. For each subject three night recordings were performed at sea level (SL), at 3500 m and 5400 m above SL. RR Interval (RRI) was derived on a beat-by-beat basis from the ECG and the VLF, LF and HF spectral components and the LF/HF ratio were estimated. Short- (α1) and long-term (α2) scale exponents as well as the recently proposed spectrum of self-similarity coefficients, α(n) were estimated by detrended fluctuation analysis (DFA). RESULTS: With respect to SL, all HRV parameters but one (α2) were significantly modified at 3500 m. However, at 5400 m they tended to return to the SL values and this was in contrast with the increase in the hypobaric hypoxia and in the number of central sleep apneas occurring at higher altitude. The only HRV index that displayed changes at 5400 m was the DFA α(n) spectrum, with α(n) values significantly lower than at SL for 20 < n <50 and higher for 200 < n <400, being n the box size. CONCLUSIONS: While the biological interpretation of these results is still in progress, our data indicates that the cardiac response to high altitude hypoxia during sleep can hardly be fully explored by traditional HRV estimators only, and requires the additional support of more sophisticated indexes exploring also nonlinear and fractal features of cardiac variability.


Assuntos
Altitude , Frequência Cardíaca/fisiologia , Modelos Cardiovasculares , Monitorização Fisiológica/instrumentação , Sono/fisiologia , Têxteis , Doença da Altitude/diagnóstico , Doença da Altitude/fisiopatologia , Vestuário , Eletrocardiografia , Eletroculografia , Desenho de Equipamento , Feminino , Fractais , Humanos , Hipóxia/diagnóstico , Hipóxia/fisiopatologia , Modelos Lineares , Masculino , Teste de Materiais , Movimento/fisiologia , Dinâmica não Linear , Valores de Referência , Taxa Respiratória/fisiologia
6.
Artigo em Inglês | MEDLINE | ID: mdl-18003559

RESUMO

On the basis of indirect evidences it has been hypothesized that during space missions the almost complete absence of gravity might impair the baroreflex control of circulation. In the first part of this paper we report results obtained from a series of experiments carried out to directly verify this hypothesis during the 16-day STS 107 Shuttle flight. Spontaneous baroreflex sensitivity was assessed in four astronauts before flight (baseline) and at days 0-1, 6-7 and 12-13 during flight, both at rest and while performing moderate exercise. Our results indicate that at rest the baroreflex sensitivity significantly increased in the early flight phase, as compared to pre-flight values and tended to return to baseline in the mid-late phase of flight. During exercise, baroreflex sensitivity was lower than at rest, without any difference among pre-flight and in-flight values. These findings seem to exclude the hypothesis of an impairment of the baroreflex control of heart rate during exposure to microgravity, at least over a time window of 16 days. In the second part of the paper we propose a novel textile-based methodology for heart rate and other vital signs monitoring during gravity stress. The positive results obtained from its use during parachute jumps support the use of smart garments for the unobtrusive assessment of physiological parameters in extreme environments.


Assuntos
Aviação , Gravidade Alterada , Frequência Cardíaca/fisiologia , Voo Espacial , Telemetria/instrumentação , Aeronaves , Barorreflexo , Pressão Sanguínea , Eletrocardiografia , Humanos , Telemetria/métodos , Têxteis
7.
Leukemia ; 19(1): 49-56, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15538405

RESUMO

Assessment of minimal residual disease (MRD) by flow cytometry is considered to be based on the reproducibility of the leukemic immunophenotype detected at diagnosis. However, we previously noticed modulation of surface antigen expression in acute lymphoblastic leukemia (ALL) during the early treatment. Hence, we investigated this in 30 children with B-cell precursor ALL consecutively enrolled in the AIEOP-BFM ALL 2000 protocol. Quantitative expression of seven antigens useful in MRD monitoring was studied at diagnosis and compared to that measured at different time points of remission induction therapy. Downmodulation in the expression of CD10 and CD34 occurred at follow-up. By contrast, upmodulation of CD19, CD20, CD45RA, and CD11a was observed, while the expression of CD58 remained stable. Despite this, we could unambiguously discriminate leukemic cells from normal residual B cells. This holds true when bone marrow (BM) samples from similarly treated T-ALL patients, but not from healthy donors, were used as reference. Our results indicate that immunophenotypic modulation occurs in ALL during the early phases of BFM-type protocols. However, the accuracy of MRD detection by flow cytometry seems not negatively affected if adequate analysis protocols are employed. Investigators should take this phenomenon into account in order to avoid pitfalls in flow cytometric MRD studies.


Assuntos
Neoplasia Residual , Leucemia-Linfoma Linfoblástico de Células Precursoras/imunologia , Antígenos CD/imunologia , Criança , Estudos de Coortes , Humanos , Imunofenotipagem , Reação em Cadeia da Polimerase , Leucemia-Linfoma Linfoblástico de Células Precursoras/terapia , Indução de Remissão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...