Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Arch Phys Med Rehabil ; 100(12): 2346-2353, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31351076

RESUMO

OBJECTIVE: To study the ability of peak cough flow (PCF) and effective cough volume, defined as the volume exsufflated >3 L/s, to detect upper airway collapse during mechanical insufflation-exsufflation (MI-E) titration in neuromuscular patients. DESIGN: Prospective observational study. SETTING: Rehabilitation hospital. PARTICIPANTS: Patients (N=27) with neuromuscular disease causing significant impairment of chest wall and/or diaphragmatic movement. INTERVENTIONS: The lowest insufflation pressure producing the highest inspiratory capacity was used. Exsufflation pressure was decreased from -20 cm H2O to -60/-70 cm H2O, in 10-cm H2O decrements, until upper airway collapse was detected using the reference standard of flow-volume curve analysis (after PCF, abrupt flattening or flow decrease vs previous less negative exsufflation pressure). MAIN OUTCOME MEASURES: PCF and effective cough volume profiles during expiration with MI-E. RESULTS: Upper airway collapse occurred in 10 patients during titration. Effective cough volume increased with decreasing expiratory pressure then decreased upon upper airway collapse occurrence. PCF continued to increase after upper airway collapse occurrence. In 5 other patients, upper airway collapse occurred at the initial -20 cm H2O exsufflation pressure, and during titration, PCF increased and effective cough volume remained unchanged at <200 mL. PCF had 0% sensitivity for upper airway collapse, whereas effective cough volume had 100% sensitivity and specificity. CONCLUSION: Of 27 patients, 15 experienced upper airway collapse during MI-E titration. Upper airway collapse was associated with an effective cough volume decrease or plateau and with increasing PCF. Accordingly, effective cough volume, but not PCF, can detect upper airway collapse.


Assuntos
Tosse/fisiopatologia , Doenças Neuromusculares/fisiopatologia , Doenças Neuromusculares/reabilitação , Modalidades de Fisioterapia , Respiração Artificial/métodos , Adulto , Feminino , Humanos , Insuflação/métodos , Masculino , Estudos Prospectivos , Testes de Função Respiratória , Músculos Respiratórios/fisiopatologia , Adulto Jovem
2.
Respir Care ; 64(3): 255-261, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30425166

RESUMO

BACKGROUND: Breath-stacking, which consists of taking 2 or more consecutive ventilator insufflations without exhaling, is a noninvasive and inexpensive cough-assistance technique for patients with neuromuscular disease. Volumetric cough mode (VCM) is a recently introduced ventilator mode consisting of a programmable intermittent deep breath equal to a set percentage of the baseline tidal volume. Here, our objective was to compare VCM to breath-stacking during volume-control continuous mandatory ventilation in subjects on long-term noninvasive mechanical ventilation at home. METHODS: We included 20 subjects with neuromuscular disease causing severe respiratory muscle dysfunction with a cough peak flow (CPF) < 270 L/min or maximum expiratory pressure < 45 cm H2O. Each subject tested breath-stacking and VCM in random order. RESULTS: CPF increased with both techniques but was higher with VCM than with breath-stacking in 16 subjects. In 17 subjects, CPF was highest with the technique that produced the greatest inspiratory capacity. CONCLUSION: Our results indicate that both breath-stacking and VCM are useful cough-augmentation techniques. Displaying insufflated volumes on the ventilator screen is a simple and accessible method for selecting the most efficient cough-augmentation technique delivered by a home ventilator.


Assuntos
Tosse/terapia , Serviços Hospitalares de Assistência Domiciliar/organização & administração , Doenças Neuromusculares/complicações , Insuficiência Respiratória/terapia , Terapia Respiratória/instrumentação , Adulto , Idoso , Estudos de Coortes , Tosse/fisiopatologia , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Neuromusculares/diagnóstico , Pico do Fluxo Expiratório , Prognóstico , Respiração Artificial/métodos , Insuficiência Respiratória/etiologia , Terapia Respiratória/métodos , Estudos Retrospectivos , Volume de Ventilação Pulmonar/fisiologia , Resultado do Tratamento , Ventiladores Mecânicos , Adulto Jovem
3.
Ann Intensive Care ; 8(1): 18, 2018 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-29404723

RESUMO

BACKGROUND: Identifying patients at high risk of post-extubation acute respiratory failure requiring respiratory or mechanical cough assistance remains challenging. Here, our primary aim was to evaluate the accuracy of easily collected parameters obtained before or just after extubation in predicting the risk of post-extubation acute respiratory failure requiring, at best, noninvasive mechanical ventilation (NIV) and/or mechanical cough assistance and, at worst, reintubation after extubation. METHODS: We conducted a multicenter prospective, open-label, observational study from April 2012 through April 2015. Patients who passed a weaning test after at least 72 h of endotracheal mechanical ventilation (MV) were included. Just before extubation, spirometry and maximal pressures were measured by a technician. The results were not disclosed to the bedside physicians. Patients were followed until discharge or death. RESULTS: Among 3458 patients admitted to the ICU, 730 received endotracheal MV for longer than 72 h and were then extubated; among these, 130 were included. At inclusion, the 130 patients had mean ICU stay and endotracheal MV durations both equal to 11 ± 4.2 days. After extubation, 36 patients required curative NIV, 7 both curative NIV and mechanical cough assistance, and 8 only mechanical cough assistance; 6 patients, all of whom first received NIV, required reintubation within 48 h. The group that required NIV after extubation had a significantly higher proportion of patients with chronic respiratory disease (P = 0.015), longer endotracheal MV duration at inclusion, and lower Medical Research Council (MRC) score (P = 0.02, P = 0.01, and P = 0.004, respectively). By multivariate analysis, forced vital capacity (FVC) and peak cough expiratory flow (PCEF) were independently associated with (NIV) and/or mechanical cough assistance and/or reintubation after extubation. Areas under the ROC curves for pre-extubation PCEF and FVC were 0.71 and 0.76, respectively. CONCLUSION: In conclusion, FVC measured before extubation correlates closely with FVC after extubation and may serve as an objective predictor of post-extubation respiratory failure requiring NIV and/or mechanical cough assistance and/or reintubation in heterogeneous populations of medical ICU patients. ClinicalTrials.gov as #NCT01564745.

4.
Clin Respir J ; 12(3): 890-894, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28026119

RESUMO

INTRODUCTION: Mouthpiece ventilation represents a valuable treatment for patients needing daytime non-invasive ventilation. This modality is however underused, in part because of limitations in the available equipment. OBJECTIVE: To develop a new flexible and moldable mouthpiece, aiming to address some of the issues of the currently available interfaces. METHODS: We compared two commercially available and the newly developed mouthpieces in a bench test using four life-support home ventilators and three settings per ventilator. RESULTS: The three interfaces showed marked differences in their resistive characteristics. In the volume-controlled setting (VC-CMV) with 500 mL tidal volume (VT ), the delivered VT , ranged between 459 ± 7 mL (-8%) and 501 ± 4 mL (+0.2%), according to the used ventilator. In the VC-CMV setting with VT 1000 mL, one of the ventilators did not assure the set VT with the new mouthpiece, because of the high-pressure limitation. In the pressure-controlled setting (PC-CMV at 20 cmH2 O), the effective pressure differed between the tested interfaces according to their resistance, resulting in a decrease in the delivered VT . CONCLUSIONS: They found measurable differences in the ventilation's performances comparing the interfaces for mouthpiece ventilation, which seem to have a minor clinical relevance in the most settings, but should be systematically checked. They validated in-vitro the newly developed mouthpiece with respect to the ventilation performances; a clinical study is needed to investigate the potential advantages we expect from the new mouthpiece.


Assuntos
Pulmão/fisiologia , Doenças Neuromusculares/complicações , Ventilação não Invasiva/instrumentação , Insuficiência Respiratória/mortalidade , Pressão do Ar , Desenho de Equipamento , Humanos , Qualidade de Vida , Insuficiência Respiratória/psicologia , Insuficiência Respiratória/terapia , Volume de Ventilação Pulmonar/fisiologia , Ventiladores Mecânicos/normas
5.
Respir Physiol Neurobiol ; 243: 32-38, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28479116

RESUMO

Respiratory muscle weakness and chest wall abnormalities in neuromuscular diseases (NMD) may lead to decreased pulmonary volumes. We assessed the reversibility of vital capacity (VC) reduction with mechanical In-Exsufflation (MI-E). We evaluated the effects of positive inspiratory and negative expiratory pressures on spirometric variables under passive (without patients' participation) and active (with active participation) application in 47 NMD patients. VC, inspiratory capacity (IC), expiratory reserve volume (ERV) were measured during maneuvers without and with MI-E assistance, delivering inspiratory assistance (+40cmH2O), expiratory assistance (-40cmH2O) and both (±40cmH2O). Passive and active assistance improved significantly VC and IC compared to baseline (P<0.0001 for both). ERV improved only with active assistance which normalized VC in 10, IC in 18 and ERV in 6 patients, mainly in patients with late-onset NMD. MI-E assistance produced greater increases in IC than in ERV, resulting in a VC increase enhanced by patients' active participation. This type of evaluation may help to evaluate the potential reversibility of restrictive ventilatory pattern in NMDs.


Assuntos
Doenças Neuromusculares/complicações , Ventilação não Invasiva/métodos , Transtornos Respiratórios/etiologia , Transtornos Respiratórios/terapia , Volume de Ventilação Pulmonar/fisiologia , Capacidade Vital/fisiologia , Adulto , Feminino , Seguimentos , Humanos , Insuflação , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Espirometria , Adulto Jovem
6.
Neuromuscul Disord ; 27(6): 518-525, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28318818

RESUMO

Twitch mouth pressure using magnetic stimulation of the phrenic nerves and an automated inspiratory trigger is a noninvasive, non-volitional assessment of diaphragmatic strength. Our aims were to validate this method in patients with suspected neuromuscular disease, to determine the best inspiratory-trigger pressure threshold, and to evaluate whether twitch mouth pressure decreased the overdiagnosis of muscle weakness frequently observed with noninvasive volitional tests. Maximal inspiratory pressure, sniff nasal pressure, and twitch mouth pressure were measured in 112 patients with restrictive disease and suspected neuromuscular disorder. Esophageal and transdiaphragmatic pressures were measured in 64 of these patients to confirm or infirm inspiratory muscle weakness. Magnetic stimulation was triggered by inspiratory pressures of -1 and -5 cmH2O. The -5 cmH2O trigger produced the best correlation between twitch mouth pressure and twitch esophageal pressure (R2 = 0.86; P <0.0001). The best association of noninvasive tests to predict inspiratory muscle weakness was sniff nasal pressure and twitch mouth pressure. Below-normal maximal inspiratory pressure and sniff nasal pressure values suggesting inspiratory muscle weakness were found in 63/112 patients. Only 52 of these 63 patients also had abnormal twitch mouth pressure. In conclusion twitch mouth pressure measurement is a simple, noninvasive, nonvolitional technique which may help to select patients with suspected neuromuscular disorder for invasive inspiratory-muscle investigation.


Assuntos
Debilidade Muscular/diagnóstico , Doenças Neuromusculares/diagnóstico , Testes de Função Respiratória/métodos , Músculos Respiratórios/fisiopatologia , Adulto , Diafragma/fisiopatologia , Esôfago/fisiopatologia , Feminino , Humanos , Inalação , Masculino , Pessoa de Meia-Idade , Boca , Debilidade Muscular/complicações , Debilidade Muscular/fisiopatologia , Doenças Neuromusculares/complicações , Doenças Neuromusculares/fisiopatologia , Nervo Frênico/fisiopatologia , Pressão , Músculos Respiratórios/inervação , Sensibilidade e Especificidade
7.
Chron Respir Dis ; 14(2): 110-116, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27923984

RESUMO

Because progressive respiratory muscle weakness leads to decreased chest-wall motion with eventual ribcage stiffening, the purpose was to compare vital capacity (VC) and contributions of chest-wall compartments before and after volume recruitment-derecruitment manoeuvres (VRDM) in Duchenne muscular dystrophy (DMD). We studied nine patients with DMD and VC lower than 30% of predicted. VRDM was performed using 15 insufflations-exsufflations of +30 to -30 cmH2O. VC and three-dimensional chest-wall motion were measured, as well as oxygen saturation, transcutaneous partial pressure of carbon dioxide and the rapid shallow breathing index (respiratory rate/tidal volume) before (baseline) and immediately and 1 hour after VRDM. VC increased significantly immediately after VRDM (108% ± 7% of baseline, p = 0.018) but returned to baseline within 1 hour, and the rapid shallow breathing index increased significantly. The non-dominant side systematically increased immediately after VRDM ( p = 0.0077), and in the six patients with abnormal breathing asymmetry (difference >10% of VC) at baseline, this asymmetry was corrected immediately and/or 1 hour after VRDM. VRDM improved VC and reduced chest-wall motion asymmetry, but this beneficial effect waned rapidly with respiratory muscle fatigue, suggesting that VRDM may need to be repeated during the day to produce lasting benefits.


Assuntos
Distrofia Muscular de Duchenne/fisiopatologia , Distrofia Muscular de Duchenne/terapia , Respiração Artificial/métodos , Insuficiência Respiratória/fisiopatologia , Insuficiência Respiratória/terapia , Mecânica Respiratória , Capacidade Vital , Adolescente , Adulto , Humanos , Debilidade Muscular/fisiopatologia , Distrofia Muscular de Duchenne/complicações , Pletismografia , Insuficiência Respiratória/etiologia , Músculos Respiratórios/fisiopatologia , Taxa Respiratória , Parede Torácica/fisiopatologia , Fatores de Tempo , Adulto Jovem
8.
Chron Respir Dis ; 13(4): 353-360, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27146811

RESUMO

The aim of our study was to evaluate efficacy and reliability of currently available ventilators for mouthpiece ventilation (MPV). Five life-support home ventilators were assessed in a bench test using different settings simulating the specificities of MPV, such as intermittent circuit disconnection and presence of continuous leaks. The intermittent disconnection of the circuit caused relevant swings in the delivered tidal volume ( VT), showing a VT overshoot during the disconnection periods and a VT decrease when the interface was reconnected to the test lung. The five ventilators showed substantial differences in the number of respiratory cycles necessary to reach a stable VT in the volume-controlled setting, ranging from 1.3 ± 0.6 to 7.3 ± 1.2 cycles. These differences were less accentuated in the volume-assisted setting (MPV-dedicated mode, when available). Our data show large differences in the capacity of the different ventilators to deal with the rapidly changing respiratory load features that characterize MPV, which can be further accentuated according to the used ventilator setting. The dedicated MPV modes allow improvement in the performance of ventilators only in some defined situations. This has practical consequences for the choice of the ventilator to be used for MPV in a specific patient.

9.
J Appl Biomech ; 32(2): 221-6, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26671884

RESUMO

Plethysmography is an indispensable component of clinical lung function testing. However, lung volume measurement in the supine position using an optoelectronic system requires the placement of reflective markers on the anterior and lateral torso surface. The conventional method computes breath-by-breath changes in the volume between the markers and the bed, which serves as the reference plane. In contrast, the surface method consists of measuring the volume delineated by the surface area of the marker network at the onset and end of inspiration. We compared these 2 methods to spirometry during spontaneous breathing in 11 healthy volunteers and in 14 patients receiving routine visits for neuromuscular disease. Bland-Altman plots showed that agreement with spirometry was better for the surface method that the conventional method. Our results open up prospects for integrating these methods in the development of new devices.


Assuntos
Diagnóstico por Computador/métodos , Fotopletismografia/instrumentação , Fotopletismografia/métodos , Espirometria/instrumentação , Espirometria/métodos , Volume de Ventilação Pulmonar/fisiologia , Adulto , Algoritmos , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
10.
Neuromuscul Disord ; 26(2): 146-52, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26711305

RESUMO

Late-onset Pompe disease, for which enzyme replacement therapy is available, induces progressive diaphragmatic weakness. Monitoring diaphragmatic function is therefore crucial but is hindered by the need to insert esophageal and gastric probes. Vital capacity (VC), inspiratory capacity, maximal inspiratory pressure, and sniff nasal pressure are noninvasive measurements but reflect only global inspiratory-muscle function. Diaphragmatic function may be assessable noninvasively based on abdominal contribution to breathing and abdominal volume change during the VC maneuver (AVC-VC), obtained by 3-dimensional chest-wall analysis. In 11 patients, we assessed the relationships between the above-listed noninvasive variables and the invasively measured Gilbert index reflecting the diaphragmatic contribution to breathing (ratio of gastric pressure over transdiaphragmatic pressure swings during spontaneous breathing). Only abdominal contribution to breathing and AVC-VC correlated significantly with the Gilbert index (R = 0.977, P = 0.0001; and R = 0.944, P = 0.001 respectively). AVC-VC correlated significantly with transdiaphragmatic pressure swing during the sniff maneuver (R = 0.743, P = 0.0009) and with phrenic magnetic stimulation (R = 0.610, P = 0.046). Repeat testing 1 year later in the first 6 patients showed concordant changes in abdominal contribution to breathing, Gilbert index, and VC. Abdominal contribution to breathing and AVC-VC are reliable and noninvasive indices of diaphragmatic function in Pompe disease, and therefore hold promise as clinical monitoring tools.


Assuntos
Diafragma/fisiopatologia , Doença de Depósito de Glicogênio Tipo II/fisiopatologia , Testes de Função Respiratória/métodos , Parede Torácica/fisiopatologia , Adulto , Idoso , Resistência das Vias Respiratórias/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fotopletismografia/métodos , Espirometria/métodos , Capacidade Vital/fisiologia
11.
Respir Care ; 59(7): 1048-52, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24149669

RESUMO

BACKGROUND: The battery life (BL) of portable home ventilator batteries is reported by manufacturers. The aim of this study was to evaluate the effects of ventilator mode, breathing frequency, PEEP, and leaks on the BL of 5 commercially available portable ventilators. METHODS: The effects of the ventilator mode (volume controlled-continuous mandatory ventilation [VC-CMV] vs pressure support ventilation [PSV]), PEEP 5 cm H2O, breathing frequency (10, 15, and 20 breaths/min), and leaks during both volume-targeted ventilation and PSV on the BL of 5 ventilators (Elisée 150, Monnal T50, PB560, Vivo 50, and Trilogy 100) were evaluated. Each ventilator was ventilated with a test lung at a tidal volume of 700 ml and an inspiratory time of 1.2 s in the absence of leaks. RESULTS: Switching from PSV to VC-CMV or the addition of PEEP did not significantly change ventilator BL. The increase in breathing frequency from 10 to 20 breaths/min decreased the BL by 18 ± 11% (P = .005). Leaks were associated with an increase in BL during the VC-CMV mode (18 ± 20%, P = .04) but a decrease in BL during the PSV mode (-13 ± 15%, P = .04). CONCLUSIONS: The BL of home ventilators depends on the ventilator settings. BL is not affected by the ventilator mode (VC-CMV or PSV) or the addition of PEEP. BL decreases with an increase in breathing frequency and during leaks with a PSV mode, whereas leaks increase the duration of ventilator BL during VC-CMV.


Assuntos
Fontes de Energia Elétrica , Serviços de Assistência Domiciliar , Respiração Artificial/métodos , Ventiladores Mecânicos , Adulto , Humanos , Modelos Biológicos , Volume de Ventilação Pulmonar , Fatores de Tempo
12.
Chest ; 144(3): 887-895, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23519378

RESUMO

BACKGROUND: The objective was to determine whether optoelectronic plethysmography (OEP) can detect asymmetric ventilation related to unilateral or asymmetric diaphragmatic weakness, suggesting usefulness as a diagnostic tool. METHODS: Thirteen patients with suspected asymmetric diaphragmatic weakness based on dyspnea and hemidiaphragm elevation on the chest radiograph were studied as well as three patients with maltase acid deficiency (a cause of symmetrical diaphragmatic weakness). The transdiaphragmatic pressure response to unilateral magnetic stimulation (lateral twitch transdiaphragmatic pressure [latPdiTw]) and the diaphragm compound muscle action potentials (CMAPs) elicited by transcutaneous electrical stimulation of each phrenic nerve as well as OEP were performed. RESULTS: The CMAPs and latPdiTw showed unilateral or predominantly unilateral diaphragmatic weakness in nine of the 13 patients. By OEP, the affected side of the thorax and abdomen contributed < 45% of the inspiratory capacity in each of these nine patients, whereas no asymmetry was noted in the other four patients or in the three patients with maltase acid deficiency. All patients preferred OEP over CMAP or latPdiTw. CONCLUSIONS: OEP detected asymmetric ventilation in all patients diagnosed with unilateral diaphragm weakness and in no patients without this diagnosis. Thus, OEP is an effective noninvasive alternative that is preferred by the patients over CMAP response and latPdiTw.


Assuntos
Diafragma/inervação , Debilidade Muscular/diagnóstico , Pletismografia/métodos , Respiração , Paralisia Respiratória/diagnóstico , Adulto , Idoso , Diagnóstico Diferencial , Diafragma/fisiopatologia , Estimulação Elétrica , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
13.
Respir Care ; 58(4): 633-8, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22906795

RESUMO

OBJECTIVE: To determine whether optoelectronic plethysmography accurately evaluated vital capacity (VC) in patients with respiratory muscle dysfunction of variable severity, including those with paradoxical abdominal movements. METHODS: In 20 subjects, VC was measured in the supine position using both spirometry and optoelectronic plethysmography (6 optoelectronic cameras and 52 reflective markers on the anterior chest wall). RESULTS: Spirometry VC (VC-Spiro) correlated positively with optoelectronic VC (VC-Opto) (r(2) = 0.99, P < .001), and the regression line was very close to the identity line (VC-Opto [mL] = -1.202 + 1.007 × VC-Spiro [mL]). A Bland-Altman plot showed that the mean difference was -20 mL (95% CI -63 mL to 24 mL) and the limits of agreement were 163 mL (95% CI 106 mL to 231 mL) and -203 mL (95% CI -271 mL to -146 mL). The difference between the 2 values expressed as the percentage of the mean value was < 15% in all 20 subjects, < 10% in 17 (85%) subjects, and < 5% in 11 (55%) subjects. The difference, expressed as the percentage of the mean value, was unrelated to the contribution of abdominal motion to VC (r = 0.02 and P = .94), but was significantly related to body mass index (r = 0.53, P = .02). CONCLUSIONS: Optoelectronic plethysmography is accurate and suitable for VC measurement in patients with various degrees of respiratory failure, including those with paradoxical abdominal movements. This noninvasive method may be an attractive alternative for accurately measuring VC in the event of air leakage (through the mouth or tracheostomy) or when patients are unable to breathe with the dead space added by the spirometer.


Assuntos
Pletismografia , Insuficiência Respiratória/diagnóstico , Insuficiência Respiratória/fisiopatologia , Mecânica Respiratória/fisiologia , Capacidade Vital , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Insuficiência Respiratória/etiologia , Músculos Respiratórios/fisiopatologia , Espirometria , Parede Torácica , Adulto Jovem
15.
Neurocrit Care ; 17(2): 236-9, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21748507

RESUMO

BACKGROUND: The objective is to determine whether maximal inspiratory pressure (P(imax)) measurement is more sensitive than vital capacity (VC) measurement to detect acute respiratory muscle failure considering a theoretical curvilinear relationship between volume and pressure. METHODS: Review of VC and P(imax) of all patients hospitalized in ICU for Guillain-Barré syndrome (GBS) and myasthenia gravis (MG) exacerbation. RESULTS: 84 consecutive caucasian patients between 19- and 70-years-old hospitalized in intensive care unit from April 2008 to December 2010, for MG exacerbation (44 patients) and GBS (40 patients). The regression curve between VC and P(imax) was linear rather than exponential (r = 0.599, P > 0.0001). The contingency table demonstrated agreement between VC and P(imax) (χ(2)= 26.7, P = 0.0001), with similar number of patients having abnormal P(imax) associated to normal VC and normal P(imax) associated to abnormal VC (9 (10.7%) vs. 8 (9.5%) respectively). Six of the patients developed an important decrease of VC from normal value to less than 60% of the predicted value and did not present evident curvilinear relationship between VC and P(imax) during this follow-up. CONCLUSIONS: Because the regression between VC and P(imax) was linear rather than curvilinear, P(imax) was not more sensitive than VC for early detection of respiratory muscle failure in patients hospitalized in ICU for GBS and MG exacerbation. Therefore, VC remains well suited to assess acute respiratory muscle failure and P(imax) gives poor additional information.


Assuntos
Síndrome de Guillain-Barré/diagnóstico , Miastenia Gravis/diagnóstico , Insuficiência Respiratória/diagnóstico , Músculos Respiratórios/fisiopatologia , Adulto , Idoso , Feminino , Síndrome de Guillain-Barré/complicações , Síndrome de Guillain-Barré/fisiopatologia , Humanos , Inalação , Masculino , Pessoa de Meia-Idade , Miastenia Gravis/complicações , Miastenia Gravis/fisiopatologia , Pressão , Análise de Regressão , Testes de Função Respiratória , Insuficiência Respiratória/etiologia , Estudos Retrospectivos , Sensibilidade e Especificidade , Capacidade Vital
16.
Neuromuscul Disord ; 20(8): 493-8, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20558065

RESUMO

Mechanical ventilation has improved survival in patients with Duchenne muscular dystrophy (DMD). Over time, these patients experience upper airway dysfunction, swallowing impairments, and dependency on the ventilator that may require invasive mechanical ventilation via a tracheostomy. Tracheostomy is traditionally believed to further impair swallowing. We assessed swallowing performance and breathing-swallowing interactions before and after tracheostomy in 7 consecutive wheelchair-bound DMD patients, aged 25+/-4 years, over a 4-year period. Chin electromyography, laryngeal motion, and inductive respiratory plethysmography recordings were obtained during swallowing of three water-bolus sizes in random order. Piecemeal deglutition occurred in all patients over several breathing cycles. Half the swallows were followed by inspiration before tracheostomy. Total bolus swallowing time was significantly shorter (P=0.009), and the number of swallows per bolus significantly smaller (P=0.01), after than before tracheostomy. Invasive ventilation via a tracheostomy may improve swallowing.


Assuntos
Transtornos de Deglutição/etiologia , Transtornos de Deglutição/fisiopatologia , Deglutição/fisiologia , Distrofia Muscular de Duchenne/fisiopatologia , Distrofia Muscular de Duchenne/cirurgia , Traqueostomia , Adulto , Eletromiografia , Feminino , Humanos , Ventilação com Pressão Positiva Intermitente , Masculino , Pletismografia , Estudos Prospectivos , Mecânica Respiratória/fisiologia , Adulto Jovem
17.
Respir Med ; 102(12): 1737-43, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18708281

RESUMO

We hypothesized that peak values of oesophageal (Poes) and transdiaphragmatic pressure (Pdi) swings during a maximal sniff manoeuvre and a maximal static inspiratory manoeuvre (Muller manoeuvre) are comparable or give complementary information for assessing diaphragmatic and global inspiratory muscle strength. We studied 98 patients with suspected diaphragmatic dysfunction. Poes and Pdi swings were measured during maximal sniff manoeuvres (sniff), maximal Muller manoeuvres (max), and cervical magnetic phrenic nerve stimulation (cervical Tw). Eighty eight patients were able to perform both volitional manoeuvres. Among them, mean Poes sniff was significantly higher than mean Poes max (48.7+/-28.7 cm H(2)O vs. 42.9+/-27.4 cm H(2)O, p<0.05) and mean Pdi sniff was higher than mean Pdi max (49.2+/-35.1cm H(2)O vs. 42.9+/-33.3 cm H(2)O, respectively, p=0.05). Cervical Pdi Tw correlated better with Pdi sniff (p<0.0001, r=0.62) than with Pdi max (p<0.0001, r=0.44). Poes and Pdi swings were greatest during the sniff manoeuvre in 42 patients (48%) and during the Muller manoeuvre in 29 patients (33%). Among the 17 remaining patients, nine had the greatest Poes swing during a maximal sniff manoeuvre and the greatest Pdi swing during a maximal static inspiratory manoeuvre; the opposite occurred in the other eight patients. The combination of Muller manoeuvre and sniff manoeuvre increased the diagnosis of normal diaphragmatic strength from 18 patients (20%) to 21 patients (24%), and the additional analysis of cervical Pdi Tw further increased the diagnosis of normal diaphragmatic strength to 27 patients (31%). In conclusion, though sniff manoeuvre gave significantly higher values than Muller manoeuvre, both volitional manoeuvres and cervical Pdi Tw are complementary and should be used in combination to evaluate diaphragmatic muscle strength.


Assuntos
Diafragma/fisiologia , Força Muscular/fisiologia , Adulto , Idoso , Estimulação Elétrica/métodos , Esôfago/fisiologia , Feminino , Humanos , Inalação , Masculino , Pessoa de Meia-Idade , Nervo Frênico/fisiologia , Músculos Respiratórios/fisiologia
18.
Arch Phys Med Rehabil ; 89(8): 1575-9, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18602082

RESUMO

OBJECTIVE: To determine whether intermittent positive-pressure breathing (IPPB) improved lung compliance, work of breathing, and respiratory function in patients with recent high spinal cord injury (SCI). DESIGN: An unblinded randomized crossover trial. SETTING: Rehabilitation hospital. PARTICIPANTS: Patients (N=14) with SCI caused by trauma within the last 6 months and located between C5 and T6. INTERVENTION: Two months of IPPB and 2 months of conventional treatment were evaluated prospectively in random order in patients with SCI. MAIN OUTCOME MEASURES: Noninvasive lung function tests and arterial blood gas measurements were obtained repeatedly in all patients. Repeated measurements of dynamic lung compliance and work of breathing as measured by computing the area enclosed between the inspiratory esophageal pressure-tidal volume curve, and the theoretical chest wall static pressure-volume curve were performed in 7 patients. RESULTS: IPPB had no long-term effects on vital capacity (52.1%+/-11.3% vs 54.5%+/-12.5%, after conventional treatment and IPPB, respectively; P=.27), lung compliance (66.4+/-48.9 mL/cmH(2)O vs 70.3+/-38.4 mL/cmH(2)O; P=.56), or other lung function tests. IPPB did not exert short-term effects on lung compliance or work of breathing. CONCLUSIONS: IPPB produced no immediate or long-term improvements in lung function or ventilatory mechanics in patients with recent SCI. (ClinicalTrials.gov identifier: NCT00476866.).


Assuntos
Respiração com Pressão Positiva Intermitente , Traumatismos da Medula Espinal/fisiopatologia , Adolescente , Adulto , Feminino , Humanos , Complacência Pulmonar/fisiologia , Masculino , Pessoa de Meia-Idade , Testes de Função Respiratória , Traumatismos da Medula Espinal/reabilitação , Trabalho Respiratório/fisiologia
19.
J Occup Environ Med ; 47(8): 847-53, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16093935

RESUMO

OBJECTIVE: The aim of the study was to determine whether the forced oscillation technique (FOT), which does not require active cooperation, may be useful to assess bronchial responsiveness in patients with suspected occupational asthma (OA). METHODS: Changes in resistances evaluated by FOT, and DeltaFEV1 measured during methacholine challenge test were compared in 77 adults referred for suspected OA. Spearman correlations and ROC curves were used. RESULTS: R0 at the final dose of methacholine (R0hmd) and DeltaR0 were strongly correlated with DeltaFEV1 (p < 0.001). The ROC curves showed that R0hmd >or= 240% predicted was the best cut-off value to discriminate subjects with OA from nonasthmatic subjects (sensitivity: 80%, specificity: 76%). CONCLUSION: FOT can be proposed as an alternative method for the assessment of bronchial responsiveness in subjects with suspected OA, unable to correctly perform forced expiratory maneuvers.


Assuntos
Asma/diagnóstico , Testes de Provocação Brônquica/métodos , Doenças Profissionais/diagnóstico , Adolescente , Adulto , Asma/epidemiologia , Testes de Provocação Brônquica/instrumentação , Feminino , Volume Expiratório Forçado , França/epidemiologia , Humanos , Masculino , Cloreto de Metacolina , Pessoa de Meia-Idade , Doenças Profissionais/epidemiologia , Curva ROC , Fumar/epidemiologia , Inquéritos e Questionários
20.
Respir Physiol Neurobiol ; 146(2-3): 291-300, 2005 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-15766917

RESUMO

Neuromuscular disease leads to cough impairment. Cough augmentation can be achieved by mechanical insufflation (MI) or manually assisted coughing (MAC). Many studies have compared these two methods, but few have evaluated them in combination. In 155 neuromuscular patients, we assessed determinants of peak cough flow (PCF) using stepwise correlation. Maximal inspiratory capacity contributed 44% of the variance (p<0.001), expiratory reserve volume 13%, and maximal expiratory pressure 2%. Thus, augmenting inspiration seems crucial. However, parameters dependent on expiratory muscles independently influence PCF. We measured vital capacity and PCF in 10 neuromuscular patients during cough augmentation by MI, MAC, or both. MI or MAC significantly improved VC and PCF (p<0.01) as compared to the basal condition and VC and PCF were higher during MI plus MAC than during MAC or MI alone (p<0.01). In conclusion, combining MAC and MI is useful for improving cough in neuromuscular patients.


Assuntos
Tosse/fisiopatologia , Fluxo Expiratório Forçado/fisiologia , Doenças Neuromusculares/fisiopatologia , Capacidade Vital/fisiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Tosse/terapia , Estudos de Avaliação como Assunto , Feminino , Humanos , Insuflação/métodos , Masculino , Pessoa de Meia-Idade , Doenças Neuromusculares/terapia , Regressão Psicológica , Testes de Função Respiratória/métodos , Insuficiência Respiratória/fisiopatologia , Terapia Respiratória/métodos , Estudos Retrospectivos , Espirometria/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...