Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Cell Death Differ ; 21(10): 1588-99, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24853299

RESUMO

The production, accumulation and aggregation of amyloid beta (Aß) peptides in Alzheimer's disease (AD) are influenced by different modulators. Among these are iron and iron-related proteins, given their ability to modulate the expression of the amyloid precursor protein and to drive Aß aggregation. Herein, we describe that lipocalin 2 (LCN2), a mammalian acute-phase protein involved in iron homeostasis, is highly produced in response to Aß1-42 by choroid plexus epithelial cells and astrocytes, but not by microglia or neurons. Although Aß1-42 stimulation decreases the dehydrogenase activity and survival of wild-type astrocytes, astrocytes lacking the expression of Lcn2 are not affected. This protection results from a lower expression of the proapoptotic gene Bim and a decreased inflammatory response. Altogether, these findings show that Aß toxicity to astrocytes requires LCN2, which represents a novel mechanism to target when addressing AD.


Assuntos
Proteínas de Fase Aguda/genética , Peptídeos beta-Amiloides/farmacologia , Proteínas Reguladoras de Apoptose/biossíntese , Astrócitos/metabolismo , Lipocalinas/biossíntese , Lipocalinas/genética , Proteínas de Membrana/biossíntese , Proteínas Oncogênicas/genética , Proteínas Proto-Oncogênicas/biossíntese , Doença de Alzheimer , Precursor de Proteína beta-Amiloide/metabolismo , Animais , Astrócitos/citologia , Proteína 11 Semelhante a Bcl-2 , Células Cultivadas , Células Epiteliais/metabolismo , Heme Oxigenase (Desciclizante)/biossíntese , Inflamação/imunologia , Ferro/metabolismo , Lipocalina-2 , Camundongos , Camundongos Endogâmicos C57BL , Microglia/metabolismo , Neurônios/metabolismo , Ratos
2.
Dis Esophagus ; 24(6): 381-7, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21309910

RESUMO

Dysplasia and esophageal adenocarcinoma may arise in patients with Barrett's esophagus after fundoplication esophageal pH monitoring showing no acid in esophagus. This suggests the need to develop methodology to evaluate the occurrence of ultra-distal reflux (1cm above the LES). The objective of the study was to compare acid exposition in three different levels: 5cm above the upper border of the LES, 1cm above the LES and in the intrasphincteric region. Eleven patients with Barrett's esophagus after Nissen fundoplication with no clinical, endoscopic and radiologic evidence of reflux were selected. Four-channel pH monitoring took place: channel A, 5cm above the upper border of the LES; channel B, 1cm above the LES; channel C, intrasphincteric; channel D, intragastric. The results of channels A, B and C were compared. There was significant increase in number of reflux episodes and a higher fraction of time with pH <4.0 in channel B compared to channel A. There was significant decrease in fraction of time with pH <4.0 in channel B compared to channel C. Two cases of esophageal adenocarcinoma were diagnosed in the studied patients. The region 1cm above the upper border of the LES is more exposed to acid than the region 5cm above the upper border of the LES, although this exposure occurred in reduced levels. The region 1cm above the upper border of the LES is less exposed to acid than the intrasphincteric region.


Assuntos
Esôfago de Barrett/fisiopatologia , Esfíncter Esofágico Inferior/fisiologia , Refluxo Gastroesofágico/fisiopatologia , Monitorização Fisiológica/métodos , Adulto , Idoso , Esôfago de Barrett/cirurgia , Feminino , Fundoplicatura , Humanos , Concentração de Íons de Hidrogênio , Masculino , Manometria , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Adulto Jovem
3.
Endocrinology ; 150(6): 2822-8, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19213835

RESUMO

Iron is essential for normal cellular homeostasis but in excess promotes free radical formation and is detrimental. Therefore, iron metabolism is tightly regulated. Here, we show that mechanisms regulating systemic iron metabolism may also control iron release into the brain at the blood-choroid plexus-cerebrospinal fluid (CSF) barrier. Intraperitoneal administration of lipopolysaccharide (LPS) in mice triggers a transient transcription of the gene encoding for hepcidin, a key regulator of iron homeostasis, in the choroid plexus, which correlated with increased detection of pro-hepcidin in the CSF. Similarly, the expression of several other iron-related genes is influenced in the choroid plexus by the inflammatory stimulus. Using primary cultures of rat choroid plexus epithelial cells, we show that this response is triggered not only directly by LPS but also by molecules whose expression increases in the blood in response to inflammation, such as IL-6. Intracellular conveyors of these signaling molecules include signal transducer and activator of transcription 3, which becomes phosphorylated, and SMAD family member 4, whose mRNA levels increase soon after LPS administration. This novel role for the choroid plexus-CSF barrier in regulating iron metabolism may be particularly relevant to restrict iron availability for microorganism growth, and in neurodegenerative diseases in which an inflammatory underlying component has been reported.


Assuntos
Plexo Corióideo/metabolismo , Homeostase/fisiologia , Inflamação/metabolismo , Ferro/metabolismo , Animais , Peptídeos Catiônicos Antimicrobianos/metabolismo , Células Cultivadas , Plexo Corióideo/patologia , Células Epiteliais/metabolismo , Células Epiteliais/patologia , Hepcidinas , Inflamação/induzido quimicamente , Inflamação/patologia , Injeções Intraperitoneais , Interleucina-6/sangue , Lipopolissacarídeos/administração & dosagem , Lipopolissacarídeos/efeitos adversos , Camundongos , Camundongos Endogâmicos C57BL , RNA Mensageiro/metabolismo , Ratos , Ratos Wistar , Fator de Transcrição STAT3/metabolismo , Proteína Smad4/metabolismo
4.
Braz J Med Biol Res ; 39(4): 475-82, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16612470

RESUMO

Controversy exists regarding the diagnostic accuracy, optimal technique, and timing of exercise testing after percutaneous coronary intervention. The objectives of the present study were to analyze variables and the power of exercise testing to predict restenosis or a new lesion, 6 months after the procedure. Eight-four coronary multi-artery diseased patients with preserved ventricular function were studied (66 males, mean age of all patients: 59 +/- 10 years). All underwent coronary angiography and exercise testing with the Bruce protocol, before and 6 months after percutaneous coronary intervention. The following parameters were measured: heart rate, blood pressure, rate-pressure product (heart rate x systolic blood pressure), presence of angina, maximal ST-segment depression, and exercise duration. On average, 2.33 lesions/patient were treated and restenosis or progression of disease occurred in 46 (55%) patients. Significant increases in systolic blood pressure (P = 0.022), rate-pressure product (P = 0.045) and exercise duration (P = 0.003) were detected after the procedure. Twenty-seven (32%) patients presented angina during the exercise test before the procedure and 16 (19%) after the procedure. The exercise test for the detection of restenosis or new lesion presented 61% sensitivity, 63% specificity, 62% accuracy, and 67 and 57% positive and negative predictive values, respectively. In patients without restenosis, the exercise duration after percutaneous coronary intervention was significantly longer (460 +/- 154 vs 381 +/- 145 s, P = 0.008). Only the exercise duration permitted us to identify patients with and without restenosis or a new lesion.


Assuntos
Angioplastia Coronária com Balão , Doença das Coronárias/terapia , Teste de Esforço/métodos , Angiografia Coronária , Doença das Coronárias/diagnóstico , Reestenose Coronária/diagnóstico , Ecocardiografia , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Braz. j. med. biol. res ; 39(4): 475-482, Apr. 2006. tab
Artigo em Inglês | LILACS | ID: lil-425085

RESUMO

Controversy exists regarding the diagnostic accuracy, optimal technique, and timing of exercise testing after percutaneous coronary intervention. The objectives of the present study were to analyze variables and the power of exercise testing to predict restenosis or a new lesion, 6 months after the procedure. Eight-four coronary multi-artery diseased patients with preserved ventricular function were studied (66 males, mean age of all patients: 59 ± 10 years). All underwent coronary angiography and exercise testing with the Bruce protocol, before and 6 months after percutaneous coronary intervention. The following parameters were measured: heart rate, blood pressure, rate-pressure product (heart rate x systolic blood pressure), presence of angina, maximal ST-segment depression, and exercise duration. On average, 2.33 lesions/patient were treated and restenosis or progression of disease occurred in 46 (55 percent) patients. Significant increases in systolic blood pressure (P = 0.022), rate-pressure product (P = 0.045) and exercise duration (P = 0.003) were detected after the procedure. Twenty-seven (32 percent) patients presented angina during the exercise test before the procedure and 16 (19 percent) after the procedure. The exercise test for the detection of restenosis or new lesion presented 61 percent sensitivity, 63 percent specificity, 62 percent accuracy, and 67 and 57 percent positive and negative predictive values, respectively. In patients without restenosis, the exercise duration after percutaneous coronary intervention was significantly longer (460 ± 154 vs 381 ± 145 s, P = 0.008). Only the exercise duration permitted us to identify patients with and without restenosis or a new lesion.


Assuntos
Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Angioplastia Coronária com Balão , Doença das Coronárias/terapia , Teste de Esforço/métodos , Angiografia Coronária , Doença das Coronárias/diagnóstico , Reestenose Coronária/diagnóstico , Ecocardiografia , Eletrocardiografia , Seguimentos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Arq Bras Cardiol ; 63(1): 13-9, 1994 Jul.
Artigo em Português | MEDLINE | ID: mdl-7857206

RESUMO

PURPOSE: To describe groups of patients who have obstructive and non-obstructive coronary artery disease, through computadorized exercise stress test. METHODS: The test was done in 121 patients, all male, divided into 3 groups: GN group, 50 patients with normal electrocardiographic response to exercise; GLO group, 40 patients with obstructive coronary artery disease and GNO group, 31 patients with normal coronary arteries, showing one or more of the following entities: intramural coronary traject, coronary tortuosity, slow flow, mitral valve prolapse or left ventricular hypertrophy. GLO and GNO groups presented with abnormal response of the ST segment during exercise. The quantitative variables registered by computer were particularly analyzed as follows: STL (point Y depression), slope, index and ST segment integral. The magnitude of ST vector was visually measured and quantified. The statistic study was made through ANOVA and multiples comparison by the Scheffe's method, Fisher's test, quisquare and sensibility, specificity and accuracy calculation. RESULTS: There was a significant statistic difference among the 3 groups relative to slope and index (p < 0.05). The integral variable of ST segment did not allow us to differentiate the GLO and GNO groups. In the association study between the ST vector magnitude and abnormal T loop, there was an increase in sensibility of 15% in the exercise stress test. CONCLUSION: The ST segment slope below zero values, define patients having obstructive disease, and the opposite, non-obstructive disease. Values of ST segment index lower than -2 are linked to obstructive disease and higher than -2 linked to non-obstructive. Values of ST segment lower than -7 microV. s separate individuals with normal exercise stress test from those with ischemic type response. The magnitude of ST vector equal to or lower than 0.20mV define normal vectorcardiographic response to the exercise.


Assuntos
Arteriopatias Oclusivas/diagnóstico , Diagnóstico por Computador , Teste de Esforço , Isquemia Miocárdica/diagnóstico , Adulto , Idoso , Arteriopatias Oclusivas/complicações , Diagnóstico Diferencial , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/etiologia , Vetorcardiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...