Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Chem Sci ; 13(22): 6715-6731, 2022 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-35756504

RESUMO

Förster resonance energy transfer (FRET) is a widely used and ideal transduction modality for fluorescent based biosensors as it offers high signal to noise with a visibly detectable signal. While intense efforts are ongoing to improve the limit of detection and dynamic range of biosensors based on biomolecule optimization, the selection of and relative location of the dye remains understudied. Herein, we describe a combined experimental and computational study to systematically compare the nature of the dye, i.e., organic fluorophore (Cy5 or Texas Red) vs. inorganic nanoparticle (QD), and the position of the FRET donor or acceptor on the biomolecular components. Using a recently discovered transcription factor (TF)-deoxyribonucleic acid (DNA) biosensor for progesterone, we examine four different biosensor configurations and report the quantum yield, lifetime, FRET efficiency, IC50, and limit of detection. Fitting the computational models to the empirical data identifies key molecular parameters driving sensor performance in each biosensor configuration. Finally, we provide a set of design parameters to enable one to select the fluorophore system for future intermolecular biosensors using FRET-based conformational regulation in in vitro assays and new diagnostic devices.

2.
SLAS Technol ; 27(5): 302-311, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35718332

RESUMO

In 2019, the first cases of SARS-CoV-2 were detected in Wuhan, China, and by early 2020 the first cases were identified in the United States. SARS-CoV-2 infections increased in the US causing many states to implement stay-at-home orders and additional safety precautions to mitigate potential outbreaks. As policies changed throughout the pandemic and restrictions lifted, there was an increase in demand for COVID-19 testing which was costly, difficult to obtain, or had long turn-around times. Some academic institutions, including Boston University (BU), created an on-campus COVID-19 screening protocol as part of a plan for the safe return of students, faculty, and staff to campus with the option for in-person classes. At BU, we put together an automated high-throughput clinical testing laboratory with the capacity to run 45,000 individual tests weekly by Fall of 2020, with a purpose-built clinical testing laboratory, a multiplexed reverse transcription PCR (RT-qPCR) test, robotic instrumentation, and trained staff. There were many challenges including supply chain issues for personal protective equipment and testing materials in addition to equipment that were in high demand. The BU Clinical Testing Laboratory (CTL) was operational at the start of Fall 2020 and performed over 1 million SARS-CoV-2 PCR tests during the 2020-2021 academic year.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Teste para COVID-19 , Humanos , Pandemias/prevenção & controle , Reação em Cadeia da Polimerase em Tempo Real/métodos , Estados Unidos
3.
ACS Omega ; 7(7): 5804-5808, 2022 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-35224340

RESUMO

Progesterone monitoring is an essential component of in vitro fertilization treatments and reproductive management of dairy cows. Gold-standard biosensors for progesterone monitoring rely on antibodies, which are expensive and difficult to procure. We have developed an alternative transcription factor-based sensor that is superior to conventional progesterone biosensors. Here, we incorporate this transcription factor-based progesterone sensor into an affordable, portable paperfluidic format to facilitate widespread implementation of progesterone monitoring at the point of care. Oligonucleotides labeled with a fluorescent dye are immobilized onto nitrocellulose via a biotin-streptavidin interaction. In the absence of progesterone, these oligonucleotides form a complex with a transcription factor that is fluorescently labeled with tdTomato. In the presence of progesterone, the fluorescent transcription factor unbinds from the immobilized DNA, resulting in a decrease in tdTomato fluorescence. The limit of detection of our system is 27 nm, which is a clinically relevant level of progesterone. We demonstrate that transcription factor-based sensors can be incorporated into paperfluidic devices, thereby making them accessible to a broader population due to the portability and affordability of paper-based devices.

4.
ACS Cent Sci ; 7(6): 963-972, 2021 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-34235257

RESUMO

Sexually transmitted infections, including the human immunodeficiency virus (HIV) and the human papillomavirus (HPV), disproportionally impact those in low-resource settings. Early diagnosis is essential for managing HIV. Similarly, HPV causes nearly all cases of cervical cancer, the majority (90%) of which occur in low-resource settings. Importantly, infection with HPV is six times more likely to progress to cervical cancer in women who are HIV-positive. An inexpensive, adaptable point-of-care test for viral infections would make screening for these viruses more accessible to a broader set of the population. Here, we report a novel, cost-effective electrochemical platform using gold leaf electrodes to detect clinically relevant viral loads. We have combined this platform with loop-mediated isothermal amplification and a CRISPR-based recognition assay to detect HPV. Lower limits of detection were demonstrated down to 104 total copies of input nucleic acids, which is a clinically relevant viral load for HPV DNA. Further, proof-of-concept experiments with cervical swab samples, extracted using standard extraction protocols, demonstrated that the strategy is extendable to complex human samples. This adaptable technology could be applied to detect any viral infection rapidly and cost-effectively.

5.
Lab Chip ; 20(18): 3386-3398, 2020 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-32766666

RESUMO

Nucleic acid amplification tests (NAATs), which amplify and detect pathogen nucleic acids, are vital methods to diagnose diseases, particularly in cases where patients exhibit low levels of infection. For many blood-borne pathogens such as HIV or Plasmodium falciparum, it is necessary to first extract pathogen RNA or DNA from patient blood prior to NAAT analysis. Traditional nucleic acid extraction methods are expensive, resource-intensive and are often difficult to deploy to resource-limited areas where many blood-borne infections are widespread. Here, we describe a portable, paper-and-plastic device, called SNAPflex, for instrument-free nucleic acid extraction from whole blood, which builds upon our previous work for RNA extraction using a pressure-driven extraction system. SNAPflex shows improved HIV RNA extraction from simulated patient samples compared to traditional extraction methods as well as long-term stability of extracted RNA without the need for cold storage. We further demonstrated successful extraction and recovery of P. falciparum DNA from cultured parasites in whole blood. SNAPflex was designed to be easily manufacturable and deployable to resource-limited settings.


Assuntos
Malária Falciparum , RNA , DNA/genética , Humanos , Técnicas de Amplificação de Ácido Nucleico , Plásticos
6.
Anal Bioanal Chem ; 412(24): 6199-6209, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32488390

RESUMO

Loop-mediated amplification (LAMP) is an isothermal amplification technique favored in diagnostics and point-of-care work due to its high sensitivity and ability to run in isothermal conditions. In addition, a visual readout by lateral flow strips (LFS) can be used in conjunction with LAMP, making the assay accessible at the point-of-care. However, the amplicons resulting from a LAMP reaction varied in length and shape, making them undiscernible on a double-stranded DNA intercalating dye stained gel. Standard characterization techniques also do not identify which amplicons specifically bind to the LFS, which generate the visual readout. We aimed to standardize our characterization of LAMP products during assay development by using fluorescein amidite (FAM) and biotin-tagged loop forward and backward primers during assay development. A pvuII restriction enzyme digest is applied to the LAMP products. FAM-tagged bands are directly correlated with the LFS visual readout. We applied this assay development workflow for an HPV 16 assay using both plasmid DNA and clinical samples to demonstrate proof of concept for generalized assay development work.


Assuntos
Papillomavirus Humano 16/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Papillomavirus Humano 16/genética , Humanos , Estudo de Prova de Conceito , Sensibilidade e Especificidade
7.
Nat Commun ; 11(1): 1276, 2020 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-32152281

RESUMO

Bacteria are an enormous and largely untapped reservoir of biosensing proteins. We describe an approach to identify and isolate bacterial allosteric transcription factors (aTFs) that recognize a target analyte and to develop these TFs into biosensor devices. Our approach utilizes a combination of genomic screens and functional assays to identify and isolate biosensing TFs, and a quantum-dot Förster Resonance Energy Transfer (FRET) strategy for transducing analyte recognition into real-time quantitative measurements. We use this approach to identify a progesterone-sensing bacterial aTF and to develop this TF into an optical sensor for progesterone. The sensor detects progesterone in artificial urine with sufficient sensitivity and specificity for clinical use, while being compatible with an inexpensive and portable electronic reader for point-of-care applications. Our results provide proof-of-concept for a paradigm of microbially-derived biosensors adaptable to inexpensive, real-time sensor devices.


Assuntos
Actinobacteria/metabolismo , Técnicas Biossensoriais , Progesterona/metabolismo , Sequência de Bases , Transferência Ressonante de Energia de Fluorescência , Testes Imediatos , Reprodutibilidade dos Testes , Fatores de Transcrição/metabolismo
8.
Anal Chim Acta ; 1017: 34-40, 2018 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-29534793

RESUMO

Proper management of an HIV infection requires that a patient be at least 80-95% adherent to a prescribed drug regimen to avoid poor health outcomes and the development of drug-resistant HIV strains. Clinicians generally monitor adherence habits indirectly through patient self-reporting, pill counting, and electronic drug monitoring. While direct measurement of patient samples like urine for monitoring drug levels is possible, it requires specialized equipment and training that is not readily available in resource-limited settings where the need is greatest. In this work we report the development of an antibody that binds to tenofovir (TFV), a key small molecule drug for both the treatment and prevention of HIV, and a competitive lateral flow assay that uses that antibody to monitor urine samples for the presence of the drug. TFV was conjugated to an immunogenic protein and injected into rabbits to raise polyclonal antibodies sensitive to the drug. The antibodies were verified for TFV-sensitivity by immunoprecipitation and HPLC. A gold nanoparticle-based competitive assay was developed to detect the presence of TFV in urine samples with a sensitivity of 1 µg mL-1. This TFV assay could be deployed as a point-of-care device for adherence monitoring in resource-limited settings as a low-cost, accurate, and speedy alternative to current methods to better inform changes in treatment.


Assuntos
Fármacos Anti-HIV/urina , Imunoprecipitação , Tenofovir/urina , Animais , Fármacos Anti-HIV/imunologia , Anticorpos/imunologia , Cromatografia Líquida de Alta Pressão , Humanos , Coelhos , Tenofovir/imunologia
9.
PLoS One ; 12(5): e0176848, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28475611

RESUMO

DNA extraction from clinical samples is commonly achieved with a silica solid phase extraction column in the presence of a chaotrope. Versions of these protocols have been adapted for point of care (POC) diagnostic devices in miniaturized platforms, but commercial kits require a high amount of input DNA. Thus, when the input clinical sample contains less than 1 µg of total DNA, the target-specific DNA recovery from most of these protocols is low without supplementing the sample with exogenous carrier DNA. In fact, many clinical samples used in the development of POC diagnostics often exhibit target DNA concentrations as low as 3 ng/mL. With the broader goal of improving the yield and efficiency of nucleic acid-based POC devices for dilute samples, we investigated both DNA adsorption and recovery from silica particles by using 1 pg- 1 µg of DNA with a set of adsorption and elution buffers ranging in pH and chaotropic presence. In terms of adsorption, we found that low pH and the presence of chaotropic guanidinium thiocyanate (GuSCN) enhanced DNA-silica adsorption. When eluting with a standard low-salt, high-pH buffer, > 70% of DNA was unrecoverable, except when DNA was initially adsorbed with 5 M GuSCN at pH 5.2. Unrecovered DNA was either not initially adsorbed or irreversibly bound on the silica surface. Recovery was improved when eluting with 95°C formamide and 1 M NaOH, which suggested that DNA-silica-chaotrope interactions are dominated by hydrophobic interactions and hydrogen bonding. While heated formamide and NaOH are non-ideal elution buffers for practical POC devices, the salient results are important for engineering a set of optimized reagents that could maximize nucleic acid recovery from a microfluidic DNA-silica-chaotrope system.


Assuntos
DNA/isolamento & purificação , Dióxido de Silício/química , Adsorção , DNA/química , Concentração de Íons de Hidrogênio , Interações Hidrofóbicas e Hidrofílicas , Limite de Detecção , Miniaturização , Reação em Cadeia da Polimerase
10.
Anal Chem ; 87(15): 7872-9, 2015 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-26125635

RESUMO

The 2009 Influenza A (H1N1) pandemic disproportionately affected the developing world and highlighted the key inadequacies of traditional diagnostic methods that make them unsuitable for use in resource-limited settings, from expensive equipment and infrastructure requirements to unacceptably long turnaround times. While rapid immunoassay diagnostic tests were much less costly and more context-appropriate, they suffered from drastically low sensitivities and high false negative rates. An accurate, sensitive, and specific molecular diagnostic that is also rapid, low-cost, and independent of laboratory infrastructure is needed for effective point-of-care detection and epidemiological control in these developing regions. We developed a paper-based assay that allows for the extraction and purification of RNA directly from human clinical nasopharyngeal specimens through a poly(ether sulfone) paper matrix, H1N1-specific in situ isothermal amplification directly within the same paper matrix, and immediate visual detection on lateral flow strips. The complete sample-to-answer assay can be performed at the point-of-care in just 45 min, without the need for expensive equipment or laboratory infrastructure, and it has a clinically relevant viral load detection limit of 10(6) copies/mL, offering a 10-fold improvement over current rapid immunoassays.


Assuntos
Técnicas Genéticas , Vírus da Influenza A Subtipo H1N1/genética , Influenza Humana/diagnóstico , RNA/genética , Técnicas Genéticas/economia , Técnicas Genéticas/instrumentação , Técnicas Genéticas/normas , Humanos , Vírus da Influenza A Subtipo H1N1/química , Vírus da Influenza A Subtipo H1N1/isolamento & purificação , Limite de Detecção , Papel , Sistemas Automatizados de Assistência Junto ao Leito , RNA/química
11.
ACS Biomater Sci Eng ; 1(5): 314-319, 2015 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-33429574

RESUMO

Monitoring the adherence of patients taking highly active antiretroviral therapy (HAART) is a key step in treating an HIV infection, especially in resource-limited settings in the developing world. For most regimens, when patients are not at least 95% adherent to their drug schedule, there is a loss of effectiveness in treatment resulting in increases in health care costs, increases in the rate of transmission, and reduction of positive patient outcomes. Currently, subjective methods such as pill counting, electronic drug monitoring, and patient self-reporting are the only ways clinicians can track adherence and intervene in cases of noncompliance. We address this issue by developing a dipstick-based point-of-care azide-alkyne click chemistry assay with colorimetric read-out that directly tests for the presence of one common HAART drug in patient urine. An alkyne-modified dextran was synthesized and characterized by NMR and then used to colorimetrically report the presence of azidothymidine, an azide-containing HAART drug, in urine samples. The assay is specific to azide-containing molecules that are not naturally present in the urine and is sensitive to physiologically relevant urine concentrations as low as 750 uM. This point-of-care device is a strong alternative in resource-limited settings over current direct measurement techniques that are expensive and require trained users such as HPLC.

12.
RSC Adv ; 4(80): 42245-42251, 2014 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-25309740

RESUMO

Herein we show the development of a minimally instrumented paper-based molecular diagnostic for point of care detection of sexually transmitted infections caused by Chlamydia trachomatis. This new diagnostic platform incorporates cell lysis, isothermal nucleic acid amplification, and lateral flow visual detection using only a pressure source and heat block, eliminating the need for expensive laboratory equipment. This paper-based test can be performed in less than one hour and has a clinically relevant limit of detection that is 100x more sensitive than current rapid immunoassays used for chlamydia diagnosis.

13.
Anal Methods ; 5(13): 3177-3184, 2013 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-23914255

RESUMO

Many new and exciting portable HIV viral load testing technologies are emerging for use in global medicine. While the potential to provide fast, isothermal, and quantitative molecular diagnostic information to clinicians in the field will soon be a reality, many of these technologies lack a robust front end for sample clean up and nucleic acid preparation. Such a technology would enable many different downstream molecular assays. Here, we present a portable system for centrifuge-free room temperature nucleic acid extraction from small volumes of whole blood (70 µL), using only thermally stable reagents compatible with storage and transport in low resource settings. Quantitative reverse transcriptase polymerase chain reaction (qRT-PCR) analysis of simulated samples demonstrate a lower limit of detection of 1000 copies/ml, with the ability to detect differences in viral load across four orders of magnitude. The system can also be used to store extracted RNA on detachable cartridges for up to one week at ambient temperature, and can be operated using only hand generated air pressure.

14.
PLoS One ; 8(3): e60059, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23555883

RESUMO

In order to counter the common perception that molecular diagnostics are too complicated to work in low resource settings, we have performed a difficult sample preparation and DNA amplification protocol using instrumentation designed to be operated without wall or battery power. In this work we have combined a nearly electricity-free nucleic acid extraction process with an electricity-free isothermal amplification assay to detect the presence of Clostridium difficile (C. difficile) DNA in the stool of infected patients. We used helicase-dependent isothermal amplification (HDA) to amplify the DNA in a low-cost, thermoplastic reaction chip heated with a pair of commercially available toe warmers, while using a simple Styrofoam insulator. DNA was extracted from known positive and negative stool samples. The DNA extraction protocol utilized an air pressure driven solid phase extraction device run using a standard bicycle pump. The simple heater setup required no electricity or battery and was capable of maintaining the temperature at 65°C±2°C for 55 min, suitable for repeatable HDA amplification. Experiments were performed to explore the adaptability of the system for use in a range of ambient conditions. When compared to a traditional centrifuge extraction protocol and a laboratory thermocycler, this disposable, no power platform achieved approximately the same lower limit of detection (1.25×10(-2) pg of C. difficile DNA) while requiring much less raw material and a fraction of the lab infrastructure and cost. This proof of concept study could greatly impact the accessibility of molecular assays for applications in global health.


Assuntos
DNA/genética , Diarreia/microbiologia , Técnicas de Amplificação de Ácido Nucleico/métodos , Clostridioides difficile/genética , Clostridioides difficile/isolamento & purificação , Clostridioides difficile/patogenicidade , Humanos , Temperatura
15.
J Vis Exp ; (73)2013 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-23567317

RESUMO

Fast and effective diagnostics play an important role in controlling infectious disease by enabling effective patient management and treatment. Here, we present an integrated microfluidic thermoplastic chip with the ability to amplify influenza A virus in patient nasopharyngeal (NP) swabs and aspirates. Upon loading the patient sample, the microfluidic device sequentially carries out on-chip cell lysis, RNA purification and concentration steps within the solid phase extraction (SPE), reverse transcription (RT) and polymerase chain reaction (PCR) in RT-PCR chambers, respectively. End-point detection is performed using an off-chip Bioanalyzer (Agilent Technologies, Santa Clara, CA). For peripherals, we used a single syringe pump to drive reagent and samples, while two thin film heaters were used as the heat sources for the RT and PCR chambers. The chip is designed to be single layer and suitable for high throughput manufacturing to reduce the fabrication time and cost. The microfluidic chip provides a platform to analyze a wide variety of virus and bacteria, limited only by changes in reagent design needed to detect new pathogens of interest.


Assuntos
Vírus da Influenza A/genética , Vírus da Influenza A/isolamento & purificação , Influenza Humana/diagnóstico , Influenza Humana/virologia , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , RNA Viral/análise , Humanos , Nasofaringe/virologia , Reação em Cadeia da Polimerase Via Transcriptase Reversa/instrumentação , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos
16.
Methods Mol Biol ; 949: 403-11, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23329456

RESUMO

Often, modern diagnostic techniques require the isolation and purification of nucleic acids directly from patient samples such as blood or stool. Many diagnostic tests are being miniaturized onto micro-sized platforms and integrated into microfluidic devices due to the economies resulting from smaller sample and reagent volumes. Often, these devices perform sample preparation in series with the diagnostic tests. The sample preparation steps are vital in order to purify the desired genetic material from potential inhibitors that can interfere with the outcome of the test. There are various techniques used to selectively capture the nucleic acids while washing away potential contamination (proteins, enzymes, lipids, etc.). Two of the most common forms of selective capture are based on nucleic acid binding to silica surface or on the precipitation of nucleic acids with or without the presence of a carrier species. Each of these methods can be performed in liquid phase or in a solid support such as an extraction column. Here we discuss both methods and address microfluidic applications.


Assuntos
Fracionamento Químico/instrumentação , DNA Bacteriano/isolamento & purificação , Técnicas Analíticas Microfluídicas/métodos , RNA Viral/isolamento & purificação , DNA Bacteriano/sangue , Humanos , Plásticos/química , RNA Viral/sangue , Extração em Fase Sólida , Raios Ultravioleta
17.
Artigo em Inglês | MEDLINE | ID: mdl-23366407

RESUMO

The ability to increase the concentration of target analytes in a fixed sample volume can potentially lower the limit of detection for many biosensing techniques, and thus is key in sample preparation for infectious disease diagnosis. Concentration by evaporation is an effective method to achieve target enrichment. However, concentrating human samples, including blood and plasma, by evaporation-based methods is made challenging by high concentrations of proteins and electrolytes. Dehydration of the proteins causes the sample to turn into a gel, hindering further analysis. At the same time, decreasing the volume increases the overall concentration of electrolytes, causing bacterial or viral particle lysis, and making them more difficult to detect in affinity-based biosensors. Thus, we fabricated a microfluidic chip that incorporates both dialysis and concentration in a single design. The chip dialyzes the proteins from the plasma, while maintaining an appropriate concentration of electrolytes and concentrating the sample targets. The process to concentrate plasma or serum samples by a factor of 10 takes less than 30 minutes. As a proof-of-concept, we demonstrated the chip using a defective Human Immunodeficiency Virus (HIV). To distinguish patients on antiretroviral therapy who are failing therapy from those who are not, a diagnostic must be able to detect HIV in plasma down to at least 1000 particles per milliliter. For a number of technical reasons, it is difficult to get on-chip PCR reactions to reach this level of sensitivity, so concentration of HIV from lower viral load samples has the potential to improve the sensitivity of many types of molecular point-of-care viral load tests.


Assuntos
Análise Química do Sangue/instrumentação , Proteínas Sanguíneas/análise , Coleta de Amostras Sanguíneas/métodos , Análise de Injeção de Fluxo/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Mol Cell ; 40(3): 353-63, 2010 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-21070963

RESUMO

Activation of the eukaryotic replicative DNA helicase, the Mcm2-7 complex, requires phosphorylation by Cdc7/Dbf4 (Dbf4-dependent kinase or DDK), which, in turn, depends on prior phosphorylation of Mcm2-7 by an unknown kinase (or kinases). We identified DDK phosphorylation sites on Mcm4 and Mcm6 and found that phosphorylation of either subunit suffices for cell proliferation. Importantly, prior phosphorylation of either S/T-P or S/T-Q motifs on these subunits is required for DDK phosphorylation of Mcm2-7 and for normal S phase passage. Phosphomimetic mutations of DDK target sites bypass both DDK function and mutation of the priming phosphorylation sites. Mrc1 facilitates Mec1 phosphorylation of the S/T-Q motifs of chromatin-bound Mcm2-7 during S phase to activate replication. Genetic interactions between priming site mutations and MRC1 or TOF1 deletion support a role for these modifications in replication fork stability. These findings identify regulatory mechanisms that modulate origin firing and replication fork assembly during cell cycle progression.


Assuntos
Proteínas de Ciclo Celular/metabolismo , Proteínas Cromossômicas não Histona/metabolismo , Proteínas de Ligação a DNA/metabolismo , Peptídeos e Proteínas de Sinalização Intracelular/metabolismo , Proteínas Nucleares/metabolismo , Proteínas Serina-Treonina Quinases/metabolismo , Proteínas de Saccharomyces cerevisiae/metabolismo , Saccharomyces cerevisiae/enzimologia , Sequência de Aminoácidos , Aminoácidos , Ciclo Celular , Cromatina/metabolismo , Componente 7 do Complexo de Manutenção de Minicromossomo , Modelos Biológicos , Dados de Sequência Molecular , Mutação/genética , Fenótipo , Fosforilação , Saccharomyces cerevisiae/citologia , Proteínas de Saccharomyces cerevisiae/química
19.
Dig Dis Sci ; 52(9): 2140-4, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17373587

RESUMO

Diarrhea and weight loss are common after pancreaticoduodenectomy, and arise from varying etiologies. An uncommon but important cause for these symptoms is the postoperative activation of silent celiac disease. We sought to describe the clinical presentation, diagnosis, treatment, and follow-up of a series of patients with silent celiac disease unmasked after pancreaticoduodenectomy, and to summarize the existing case reports on this association. A search of the electronic medical record at our institution was performed cross-referencing terms associated with celiac disease and pancreaticoduodenectomy for the years 1976-2004. Cases were then reviewed to ensure that no signs or symptoms attributable to celiac disease were present preoperatively. Seven patients were identified; five were male, and the median age was 56. All patients underwent surgery for a presumed pancreatic or ampullary malignancy. Six patients developed symptoms ultimately attributable to celiac disease immediately after pancreaticoduodenectomy, most commonly diarrhea and weight loss. A single patient had silent celiac disease incidentally diagnosed at pancreaticoduodenectomy that remained silent postoperatively on an unrestricted diet. Symptoms completely resolved in 4 of 6 patients after initiation of a gluten-free diet, with partial improvement in the remaining 2 patients. The median delay from pancreaticoduodenectomy to diagnosis of celiac disease in the 6 symptomatic patients was 6 months. Clinicians should consider celiac disease as a potential diagnosis in patients with failure to thrive and diarrhea after pancreaticoduodenectomy. This entity is uncommon, but may be under-recognized. The underlying mechanism may relate to an increased antigenic load secondary to postsurgical changes in intestinal physiology.


Assuntos
Doença Celíaca/etiologia , Neoplasias Pancreáticas/cirurgia , Pancreaticoduodenectomia/efeitos adversos , Adulto , Idoso , Doença Celíaca/dietoterapia , Doença Celíaca/patologia , Contraindicações , Diagnóstico Diferencial , Dieta com Restrição de Proteínas , Progressão da Doença , Duodeno/patologia , Feminino , Seguimentos , Glutens , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Prognóstico , Estudos Retrospectivos , Fatores de Risco
20.
Mayo Clin Proc ; 77(12): 1347-50, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12479523

RESUMO

Mediastinal lymphoma as a cause of tracheobronchial obstruction is uncommon, and a malignant tracheoesophageal fistula in the setting of mediastinal lymphoma is rare. Malignant tracheoesophageal fistulas are associated with pronounced morbidity and mortality. We describe a patient with mediastinal lymphomatous infiltration resulting in tracheal obstruction, esophageal obstruction, and tracheoesophageal fistula that were successfully palliated with combined airway and esophageal stent placement.


Assuntos
Linfoma Difuso de Grandes Células B/complicações , Neoplasias do Mediastino/complicações , Cuidados Paliativos , Stents , Fístula Traqueoesofágica/terapia , Esofagoscopia , Humanos , Masculino , Pessoa de Meia-Idade , Fístula Traqueoesofágica/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...