Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Oral Health ; 21(1): 561, 2021 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-34732188

RESUMO

PURPOSE: The scanning of plaster models for three-dimensional (3D) construction requires their rigid fixation in the intercuspal position. Factors such as installation, motion, and scanning procedures influenced the accuracy of this method, which ultimately influence the results. Therefore, the present study attempted to provide an optimal and accurate method with less complex procedures and a more accessible equipment for determining the intercuspal relation in the 3D occlusal construction of dental models. METHODS: A pair of plastic mounting plates that could be directly attached to a mechanical articulator was designed and 3D printed. Nine axial hemispherical concaves were introduced on the axial surface of each plate. The rigidly fixed maxillary and mandibular dental models were scanned directly. The distances DR between nine pairs of concaves on both mounting plates adhered to the maxillary and mandibular sections of the articulator were measured using the three-coordinate measuring machine Faro Edge as the reference. The present study comprised seven test groups varying in number and location. Assessing the reference points from each of the seven groups performed the 3D construction. The Geomagic Studio software was used to construct the concaves of digital casts, and the distances DM between the pairs of concaves were measured as test values. Variable differences between DR and DM were analyzed. RESULTS: An optimum distribution scheme was obtained for reference point registration by quantitatively evaluating accuracy levels of the 3D constructions of different reference point distribution patterns. This scheme can serve as a reference for related studies and dental clinic operations. CONCLUSIONS: Three-dimensional construction of the intercuspal relation during scanning of the maxillary and mandibular models with an accuracy of 0.046 mm ± 0.009 mm can be achieved using the improved design of mounting plates.


Assuntos
Imageamento Tridimensional , Modelos Dentários , Articuladores Dentários , Humanos , Mandíbula , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...