Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
World Neurosurg ; 188: e357-e366, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38796141

RESUMO

OBJECTIVE: The efficacy of medical treatments and the changes in radiologic imaging before and after treatment have consistently remained pivotal factors. This is particularly critical for surgical procedures, where precise evaluation of disparities pre and postsurgery or the accuracy of implantation is paramount. Based on three-dimensional morphological interests, we provide an automatic quantification evaluation method that delivers an evident base for assessing the outcomes of a widely employed surgical technique, cervical laminoplasty. METHODS: The sample study included patients who underwent cervical laminoplasty for cervical spondylotic myelopathy/ossification of the longitudinal ligament. We present a superimposition method that facilitates a unique and precise assessment between pre and postsurgery. The degree of expansion was evaluated by the canal volume increase and canal expansion rate after surgery. RESULTS: There were 31 patients with 112 vertebral segments measured. The target cervical's pre and postoperative canal areas were 122.63 ± 30.34 and 196.50 ± 37.10 mm2, respectively (P < 0.001). The average cervical canal expansion rate was 64.42%. The expansion effect of C5 cervical laminoplasty was the maximum (71.01%), and the canal volume of other segments expanded by approximately 60%. The functional outcomes demonstrated significant improvements in symptoms. CONCLUSIONS: The quantification evaluation method can be utilized for any morphology changes before and after laminoplasty, as it does not lead to errors or variations from different inspection machines or human factors. The automatic method delivers an evident base for assessing the outcomes of a widely employed surgical technique.


Assuntos
Vértebras Cervicais , Imageamento Tridimensional , Laminoplastia , Espondilose , Humanos , Laminoplastia/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Vértebras Cervicais/cirurgia , Vértebras Cervicais/diagnóstico por imagem , Idoso , Imageamento Tridimensional/métodos , Espondilose/cirurgia , Espondilose/diagnóstico por imagem , Resultado do Tratamento , Doenças da Medula Espinal/cirurgia , Doenças da Medula Espinal/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
2.
Medicine (Baltimore) ; 103(16): e37868, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38640291

RESUMO

RATIONALE: The conventional treatment of giant cell tumors is intralesional curettage with local adjuvant therapy. Because hand tumors have a high local recurrence, the primary goal for treating tumors of the hand is to eradicate the lesion. PATIENT CONCERNS: To preserve the metacarpophalangeal (MCP) joint function as well as avoid further recurrence after surgery. DIAGNOSES: The giant cell tumor invades the patient's MCP joint in an index proximal phalanx. INTERVENTIONS: Using computer-aided design and three-dimensional printing techniques, we reformed the original shapes of the MCP joint and its peripheral bone to replica models. The surgeon then performed an en bloc resection and proximal phalanx with MCP joint reconstruction by fabricating the patient's costal osteochondral graft during the operation. OUTCOMES: After 6 months of rehabilitation, the patient's finger functions could pinch and grasp objects naturally. At the 1-year follow-up, the range of motion of the MCP, proximal interphalangeal, and distal interphalangeal joints improved from flexion of 35° to 60°, 75° to 85°, and 60° to 80°, respectively. The hand function achieved the mean performance of non-preferred hands for young females at the postoperative 3-year follow-up. LESSONS: The customized prototyping technique has the potential to replica the original patient's bony graft to reach the goal of minimizing the defects at the donor site and maximizing the function of the reconstructed MCP joint.


Assuntos
Prótese Articular , Neoplasias , Feminino , Humanos , Dedos , Costelas/transplante , Articulação Metacarpofalângica/cirurgia , Amplitude de Movimento Articular , Articulações dos Dedos/cirurgia
3.
Int J Spine Surg ; 17(4): 492-501, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37253625

RESUMO

BACKGROUND: Cervical spondylotic myelopathy (CSM) is a very common and devastating spinal disease. Congenital cervical stenosis (CCS) is the most common cause. We aimed to elucidate the security, effectivity, and feasibility of surgery combining laminoplasty with artificial disc replacement (ADR) to treat CSM patients with radiculopathy, especially for preserving the range of motion (ROM) of the cervical spine. METHOD: Between August 2008 and April 2019, 39 patients with multiple CSM caused by CCS were enrolled in the present study. All patients received laminoplasty first and then ADR. We used a retrospective collection of data for evaluating the functional and radiologic outcomes, especially regarding preservation of ROM. RESULTS: Each patient underwent at least a 2-year postoperative follow-up. The Japanese Orthopedic Association score showed great improvements at 6 months. The ADR index-level ROM was preserved during follow-up. The subaxial Cobb angle could also be retained in the whole cervical spine, and the spinal canal diameter could be expanded by more than 52.6%. There were no severe complications or side effects, and no patients needed secondary surgery. CONCLUSIONS: We aimed to treat multiple levels of CSM with adequate decompression without too many intervertebral disc replacements. We were able to expand the spinal canal directly for these patients with CCS and needed only 1- or 2-level ADR to treat them with associated radiculopathy. This combined surgical strategy was secure, effective, and was able to preserve the ROM of the cervical spine.

4.
Bioengineering (Basel) ; 10(3)2023 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-36978726

RESUMO

Computer-aided surgical planning has been widely used to increase the safety and predictability of surgery. The validation of the target of surgical planning to surgical outcomes on a patient-specific model is an important issue. The aim of this research was to develop a robust superposition method to assess the deviation of planning and outcome by using the symmetrical characteristic of the affected target. The optimal symmetry plane (OSP) of an object is usually used to evaluate the degree of symmetry of an object. We proposed a refined OSP-based contouring method to transfer a complex three-dimensional superposition operation into two dimensions. We compared the typical iterative closest point (ICP) algorithm with the refined OSP-based contouring method and examined the differences between them. The results using the OSP-based method were much better than the traditional method. As for processing time, the OSP-based contouring method was 11 times faster than the ICP method overall. The proposed method was not affected by the metallic artifacts from medical imaging or geometric changes due to surgical intervention. This technique can be applied for post-operative assessment, such as quantifying the differences between surgical targets and outcomes as well as performing long-term medical follow-up.

5.
J Clin Med ; 11(19)2022 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-36233557

RESUMO

Symmetry is representative of aesthetics and health in all kinds of vertebrates, especially the human face. Therefore, to automatically locate the appropriate symmetry plane is crucial. The aim of this study was to develop an automatic and reliable method to determine the symmetry plane of the maxillofacial region. We compared the proposed method of determining the symmetry plane by assessing landmark-based and surface-based methods by way of quantitative symmetry assessments. Statistical analysis was applied to evaluate whether significant difference existed among these three kinds of symmetry planes. Twenty cases who had a diagnosis of severe facial asymmetry were evaluated retrospectively. The results showed that searching for the symmetry plane using a voxel-based method, named the optimal symmetry plane (OSP), achieved the most representative symmetry according to the outcomes of the trials. The OSP was significantly more symmetrical than the other two planes, as determined by other methods. The paired-voxel computation method proposed in this research is a robust and reliable method for identifying the unique symmetry plane for patients with severe facial asymmetry. Symmetry is of crucial significance for all kinds of vertebrates, including its clinical implications for surgical planning in orthognathic surgery.

6.
Genes (Basel) ; 13(5)2022 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-35627140

RESUMO

About 30-50% of oral cancer patients require mandibulectomy and autologous fibula reconstruction. Autograft is the gold standard choice because of its histocompatibility; however, it requires additional surgery from the patient and with possible complications such as loss of fibula leading to calf weakening in the future. Allograft and xenograft are alternatives but are susceptible to immune response. Currently, no personalized bone xenografts are available in the market for large fascial bone defects. In addition, a large-sized complex shape bone graft cannot be produced directly from the raw material. We propose the use of porcine bones with 3D CAD/CAM carving to reconstruct a personalized, wide range and complex-shaped bone. We anticipate that patients can restore their native facial appearance after reconstruction surgery. Supercritical CO2 (SCCO2) technology was employed to remove the cells, fat and non-collagenous materials while maintaining a native collagen scaffold as a biomedical device for bone defects. We successfully developed 3D CAD/CAM carved bone matrices, followed by SCCO2 decellularization of those large-sized bones. A lock-and-key puzzle design was employed to fulfil a wide range of large and complex-shaped maxillofacial defects. To conclude, the 3D CAD/CAM carved bone matrices with lock and key puzzle Lego design were completely decellularized by SCCO2 extraction technology with intact natural collagen scaffold. In addition, the processed bone matrices were tested to show excellent cytocompatibility and mechanical stiffness. Thus, we can overcome the limitation of large size and complex shapes of xenograft availability. In addition, the 3D CAD/CAM carving process can provide personalized tailor-designed decellularized bone grafts for the native appearance for maxillofacial reconstruction surgery for oral cancer patients and trauma patients.


Assuntos
Matriz Óssea , Neoplasias Bucais , Animais , Dióxido de Carbono , Xenoenxertos , Humanos , Suínos , Transplante Heterólogo
7.
China Tropical Medicine ; (12): 1201-2022.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-973822

RESUMO

@#Abstract: Schistosomiasis is a serious major parasitic disease that threatens human life and health. A better understanding of the mechanism of host-schistosome interactions is the key to designing new prevention and control strategies. MicroRNAs (miRNAs) are endogenous small non-coding RNA molecules, which lead to the degradation of the target messenger RNA (mRNA) or inhibition of its translation in a sequence-specific manner. Both schistosome and its host produce miRNAs, which can be secreted by extracellular vesicles (EVs). There is accumulating evidence that miRNAs from schistosome can be taken up by host cells, and finely manipulate the phenotype of host cells for their survival or pathogenesis in a cross-species manner, even inhibiting the growth and metastases of hepatoma cells. It is still unknown whether host free miRNAs can be taken up by schistosome, but this phenomenon is highly probable. miRNA-mediated cross-species regulation has emerged as a novel mechanism for host-schistosome interactions, and this review summarizes the advances in this regard.

8.
Exp Ther Med ; 22(6): 1443, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34721685

RESUMO

Hydrogen peroxide (H2O2) can induce apoptosis by releasing reactive oxygen species (ROS) and reactive nitrogen species, which cause mitochondrial damage. The present study aimed to investigate the protective effects of flavonoids from the leaves of Carya cathayensis Sarg. against H2O2-induced oxidative damage and apoptosis in vitro. The bioactivity of total flavonoids (TFs) and five monomeric flavonoids [cardamonin (Car), pinostrobin chalcone, wogonin, chrysin and pinocembrin] from the leaves of Carya cathayensis Sarg. (LCCS) were tested to prevent oxidative damage to rat aortic endothelial cells (RAECs) induced by H2O2. Oxidated superoxide dismutase, glutathione peroxidase, malondialdehyde, lactate dehydrogenase and ROS were analyzed to evaluate the antioxidant activity. Gene and protein expression patterns were assessed using reverse transcription-quantitative PCR and western blotting, respectively. The results indicated that TFs and Car inhibited H2O2-induced cytotoxicity and apoptosis of RAECs. Additionally, they regulated the level of oxidase and inhibited the production of ROS. Overall, the TFs extracted from LCCS could potentially be developed as effective candidate drugs to prevent oxidative stress in the future; moreover, they could also provide a direction in investigations for preventing antioxidant activity through the ROS pathway.

9.
Biomed Phys Eng Express ; 8(1)2021 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-34700306

RESUMO

Objective. Vertebrae models from computer tomographic (CT) imaging are extensively used in image-guided surgical systems to deliver percutaneous orthopaedic operations with minimum risks, but patients may be exposed to excess radiation from the pre-operative CT scans. Generating vertebrae models from intra-operative x-rays for image-guided systems can reduce radiation exposure to the patient, and the surgeons can acquire the vertebrae's relative positions during the operation; therefore, we proposed a lumbar vertebrae reconstruction method from biplanar x-rays.Approach. Non-stereo-corresponding vertebral landmarks on x-rays were identified as targets for deforming a set of template vertebrae; the deformation was formulated as a minimisation problem, and was solved using the augmented Lagrangian method. Mean surface errors between the models reconstructed using the proposed method and CT scans were measured to evaluate the reconstruction accuracy.Main results. The evaluation yielded mean errors of 1.27 mm and 1.50 mm inin vitroexperiments on normal vertebrae and pathological vertebrae, respectively; the outcomes were comparable to other template-based methods.Significance. The proposed method is a viable alternative to provide digital lumbar to be used in image-guided systems, where the models can be used as a visual reference in surgical planning and image-guided applications in operations where the reconstruction error is within the allowable surgical error.


Assuntos
Vértebras Lombares , Tomografia Computadorizada por Raios X , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Radiografia , Raios X
10.
Zhongguo Dang Dai Er Ke Za Zhi ; 23(1): 78-83, 2021 Jan.
Artigo em Chinês | MEDLINE | ID: mdl-33476542

RESUMO

OBJECTIVE: To study the effect of calorie-enriched formula on postoperative catch-up growth in infants with cyanotic congenital heart disease (CHD). METHODS: A total of 100 infants with cyanotic CHD who underwent surgical operation from January to December, 2017, were randomly divided into a high-calorie group (receiving calorie-enriched formula after surgery) and a conventional group (receiving standard formula after surgery), with 50 infants in each group. All infants were followed up for 6 months. The observation indices included body height, body weight, prealbumin, and N-terminal pro-brain natriuretic peptide before surgery, at the time of ventilator weaning and extubation after surgery, and at 1, 3, and 6 months after surgery. Height-for-age Z-score (HAZ), weight-for-age Z-score (WAZ), and weight-for-height Z-score (WHZ) were also assessed. Adverse reactions were recorded for both groups. RESULTS: There were 25 cases (50%) and 21 cases (42%) of malnutrition in the high-calorie group and the conventional group respectively before surgery (P > 0.05). The nutritional status of the two groups improved 6 months after surgery (P < 0.05). At 6 months after surgery, compared with the conventional group, the high-calorie group had a lower proportion of infants with malnutrition (18% vs 36%, P < 0.05) and also a lower proportation of infants with a WAZ score of < -2 (P < 0.05). The infants with malnutrion in the high-calorie group had higher HAZ, WAZ, and WHZ than those in the conventional group (P < 0.05). No gastrointestinal intolerance was observed in both groups during hospitalization. CONCLUSIONS: Compared with the standard formula, calorie-enriched formula can better help with postoperative catch-up growth in infants with cyanotic CHD.


Assuntos
Cardiopatias Congênitas , Peso Corporal , Ingestão de Energia , Cardiopatias Congênitas/cirurgia , Humanos , Lactente , Desnutrição , Estado Nutricional , Estudos Prospectivos
11.
Steroids ; 163: 108726, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32889051

RESUMO

The main purpose of this study was to evaluate the estrogenic properties of total flavonoids (TFs) and five flavonoid monomers (cardamonin (Car), pinostrobin chalcone (PC), wogonin (Wo), chrysin (Chr) and Pinocembrin (PI)) from leaves of Carya cathayensis Sarg (LCC). TFs from LCC were isolated and determined using HPLC. The 3-[4,5-dimethylthiazole-2-yl]-2,5-diphenyltetrazolium bromide (MTT) assay and flow cytometry were performed to assess the effects of flavonoids on cell proliferation and cell cycle, respectively. The molecular docking technique was applied to investigate binding conformations of the monomers from LCC to the estrogen receptor ERα and ERß. Gene and protein expression patterns were assessed using quantitative real-time PCR (qRT-PCR) and western blot, respectively. The results showed that TFs, Car, PC, Wo and Chr promoted proliferation of MCF-7 cells and cell transition from the G1 to S phase, and inhabitation of MCF-7 cell proliferation was observed after the treatment of PI. Molecular docking studies confirmed ERs as molecular targets for the monomers. TFs, Car, PC, Wo and Chr from LCC promoted gene expression of ERα, ERß, progesterone receptor (PR) and pS2. Our collective results demonstrated that TFs and monomers from LCC may exert ER agonist activity through competitively bind to ER, inducing ER upregulation and active ER to estrogen response element (ERE)- independent gene regulation. As an abundant natural product, LCC may provide a novel medicinal source for treatment of diseases caused by estrogen deficiency.


Assuntos
Carya/química , Estrogênios/metabolismo , Estrogênios/farmacologia , Flavonoides/metabolismo , Flavonoides/farmacologia , Simulação de Acoplamento Molecular , Folhas de Planta/química , Ciclo Celular/efeitos dos fármacos , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Receptor alfa de Estrogênio/química , Receptor alfa de Estrogênio/metabolismo , Receptor beta de Estrogênio/química , Receptor beta de Estrogênio/metabolismo , Estrogênios/química , Flavonoides/química , Humanos , Conformação Proteica
12.
J Neurol Surg Rep ; 81(1): e20-e27, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32257765

RESUMO

Objective Atlantoaxial fixation is technically demanding and challenging, especially in cases with anatomical abnormality. The purpose of this study is to report the effectiveness of the three-dimensional (3D)-customized guiding template for placement of C1 and C2 screws in cases with abnormalities. Method Two patients with anatomical abnormality and one without were included. The preoperative computed tomography (CT) image was analyzed using our software. The entry point, trajectory, and depth of the screws were designed based on these images. Templates with screw guiding cylinders and cervical spine model were created. In operation, guiding templates were applied directly to the laminae. Drilling, tapping, and screwing were performed through the cylinders. To evaluate the accuracy, deviation of the screw axis from the preplanned trajectory was measured on postoperative CT. A classification system was taking to evaluate the pedicle screw insertion. Results In complex cases, one of C2 screws has grade 2 deviation, and two has grade 1. There was no deviation in screws of C1. All patients achieved symptoms free after 6 months follow-up. Conclusion Although 3D-printed template for atlantoaxial fixation still has limitation in complex cases, it has been proved usefulness and makes the most difficult and dangerous spinal posterior fixation easy to achieve.

13.
Iran J Public Health ; 49(Suppl 1): 87-91, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34268210

RESUMO

BACKGROUND: To explore the homogenized management method of infection prevention and control in medical resident under COVID-19 epidemic situation. METHODS: Overall, 268 members in Ningbo Medical Group which was participating in the management of novel coronavirus pneumonia in Wuhan, China were managed homogeneously in terms of personal cleaning and disinfection of articles, prevention and control of infection in life, training and assessment of relevant infection knowledge in hospitals. RESULTS: In the epidemic situation, the homogenization management of infection prevention and control in the resident of medical team is an important measure to block the transmission link. CONCLUSION: 1. Conduct homogenization management on the training of hospital infection knowledge for medical staff. 2. Conduct homogeneous management of effective assessment of training knowledge. 3. Conduct homogenization management from personal cleaning and disinfection, as well as infection prevention and control in daily life.

14.
Eur Spine J ; 28(8): 1793-1803, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31168662

RESUMO

PURPOSE: A slouching posture during smartphone usage increases gravitational loadings on the cervical spine, which may lead to neck pain and degeneration. The objective of the present study was to investigate the head, neck and trunk angles in different smartphone-usage postures, as well as the posture-correction effects and comfort scores of three neck collars. METHODS: This was a prospective cohort study in which 41 healthy young subjects aged 18-25 were recruited. The head, neck and trunk angles were measured in all participants during a neutral position and three smartphone-using postures, including sitting with and without back support and standing. The postural correction and comfort scores of three collars (Aspen Vista, Sport-aid and our customized 3D printed collars) were compared. RESULTS: Smartphone use increased the head and neck flexion angles in all postures, and sitting without back support showed the greatest head and neck flexion angles. The posture-correcting effect of the customized collar was better than the Aspen Vista and Sport-aid collars. In addition, the customized collar was more comfortable to wear than the other two collars in most contact areas. CONCLUSION: Smartphone use increased both the head and neck flexion in different postures, and the proposed customized 3D-printed cervical collar significantly reduced the head and neck angles. These slides can be retrieved under Electronic Supplementary Material.


Assuntos
Braquetes , Pescoço/fisiologia , Postura/fisiologia , Smartphone , Adolescente , Adulto , Voluntários Saudáveis , Humanos , Estudos Prospectivos , Amplitude de Movimento Articular/fisiologia , Adulto Jovem
15.
J Int Med Res ; 46(8): 3104-3113, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29882444

RESUMO

Objective We assessed our results of short-segment decompression and fixation for osteoporotic thoracolumbar fractures with neurological deficits. Methods We evaluated 20 elderly patients (age, 60-89 years; mean, 73.2 years) with osteoporotic thoracolumbar fractures and neurological deficits. They underwent short-segment decompression and fixation and followed up for 40.6 (range, 24-68) months. A visual analog scale (VAS) and the Oswestry Disability Index (ODI) were used to measure back pain and disability. We also analyzed patients' radiologic findings and neurological status. Perioperative and postoperative complications were recorded. Results At the latest follow-up, the average VAS score for back pain and ODI scores had significantly improved. The radiologic assessment showed significant improvements in local kyphosis, anterior vertebral height, and the vertebral wedge angle compared with the original measures. Neurological function also improved in 18 of 20 patients. No major complications occurred perioperatively. Our techniques included preservation of the posterior ligament complex, decortication of facet joints for fusion, no tapping to increase the screw insertional torque, pre-contouring of the rods according to the "adaptive" curve obtained from postural reduction, and postoperative spinal bracing. Conclusions Posterior short-segment decompression and fixation could be an effective surgical option for osteoporotic thoracolumbar burst fractures with neurological deficits.


Assuntos
Laminectomia/métodos , Fraturas por Osteoporose/cirurgia , Fraturas da Coluna Vertebral/cirurgia , Fusão Vertebral/métodos , Idoso , Idoso de 80 Anos ou mais , Síndrome da Cauda Equina/etiologia , Feminino , Fixação Interna de Fraturas , Humanos , Hipestesia/etiologia , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Debilidade Muscular/etiologia , Fraturas por Osteoporose/complicações , Paraplegia/etiologia , Estudos Retrospectivos , Fraturas da Coluna Vertebral/complicações , Vértebras Torácicas/cirurgia , Resultado do Tratamento
16.
World Neurosurg ; 116: e1144-e1152, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29870845

RESUMO

OBJECTIVE: To assess accuracy and safety of self-developed customized guiding templates for cervical pedicle screw (CPS) insertion surgery. METHODS: From July 2016 to December 2017, 57 screws were implanted in 9 patients with the assistance of customized guiding templates. Customized guiding templates were manufactured from acrylonitrile-butadiene-styrene plastic material using a three-dimensional printer after establishing pedicle screw trajectories for each vertebra with the assistance of a virtual surgical planning software program, developed by our team, for the insertion of CPSs. RESULTS: CPSs were evaluated using the following grading system: grade 0 (contained), grade 1 (exposure), grade 2 (perforation), and grade 3 (penetration). Each patient underwent postoperative computed tomography to evaluate accuracy of screw position. Of 57 screws, 54 were graded 0, and 3 were graded 1; no screws were graded 2 or 3. No vascular or nerve injuries were noted after the operations. CONCLUSIONS: CPSs, which provide strong biologic strength, are especially suitable for treating osteoporosis and severe deformity. However, CPS insertion remains a challenging procedure with high incidences of vascular and nerve injuries reported. The results of this study indicate that use of customized guiding templates can improve safety of CPS insertion surgery.


Assuntos
Vértebras Cervicais/cirurgia , Parafusos Pediculares , Doenças da Coluna Vertebral/cirurgia , Fusão Vertebral , Adulto , Idoso , Feminino , Fraturas Ósseas/cirurgia , Humanos , Luxações Articulares/cirurgia , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Retrospectivos , Fusão Vertebral/métodos , Cirurgia Assistida por Computador/métodos
17.
Am J Orthod Dentofacial Orthop ; 153(1): 70-80, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29287657

RESUMO

INTRODUCTION: Little is known regarding how the mandible rotates in facial asymmetry. The purpose of this study was to study mandibular misalignment with a new plane-to-plane analysis method in patients with facial asymmetry. METHODS: Optimal symmetry planes (OSPs) were generated by computing the greatest count of paired voxels on opposing sides of the computerized tomography image of the structure. The mandibular OSP was measured against the midfacial OSP for its alignment. The deviation angle formed by the 2 OSPs was broken down into a y-axis component (frontal deviation angle) and a z-axis component (horizontal deviation angle). Fifty-nine patients who sought correction for facial asymmetry were included for study. RESULTS: The new analysis method was feasible. Fifty patients (83%) had significant mandibular misalignment (deviation, ≥4° or 4 mm). The locations of the rotational axes exhibited significant variations that could explain the varied features of the asymmetry. The frontal deviation angle (mean, 3.80° ± 3.89°) was significantly larger than the horizontal deviation angle (mean, 2.77° ± 1.71°). There was no significant correlation between the horizontal deviation angle and the anterior deviation distance or the posterior deviation distance. CONCLUSIONS: Proper mandibular realignment was suggested to be the primary aim in surgical correction of most jawbone asymmetries. Because of the greatly varied rotational axes and the obscure z-axis rotation, realignment could be difficult with the traditional approach. The OSP-based analysis is advocated to guide planning.


Assuntos
Assimetria Facial/diagnóstico por imagem , Mandíbula/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Cefalometria , Humanos , Imageamento Tridimensional , Estudos Retrospectivos
18.
Medicine (Baltimore) ; 95(43): e5100, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27787362

RESUMO

Atlantoaxial instability treated with the C1-2 transarticular screw fixation is biomechanically more stable; however, the technique demanding and the potential risk of neurovascular injury create difficulties for clinical usage, and there is still lack of clinical experience till now.We reported an adult female patient with symptomatic atlantoaxial instability due to rheumatoid arthritis that was successfully treated with a bilateral C1-C2 transarticular screw fixation using a customized guiding block. We preoperatively determined the trajectories for bilateral C1-C2 transarticular screws on a 3-dimensional reconstruction model from the computed tomography (CT) and self-developed computer software, and designed a rapid prototyping customized guiding block in order to offer a guide for the entry point and insertion angle of the C1-C2 transarticular screws.The clinical outcome was good, and the follow-up period was >3 years. The accuracy of the screws is good in comparison with preoperative and postoperative CT findings, and no neurovascular injury occurred.The patient was accurately and successfully treated with a bilateral C1-C2 transarticular screw fixation using a customized guiding block.


Assuntos
Articulação Atlantoaxial/cirurgia , Parafusos Ósseos , Vértebras Cervicais/cirurgia , Instabilidade Articular/cirurgia , Fusão Vertebral/métodos , Articulação Atlantoaxial/diagnóstico por imagem , Vértebras Cervicais/diagnóstico por imagem , Feminino , Humanos , Instabilidade Articular/diagnóstico , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
19.
Eur Spine J ; 25(12): 4103-4107, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27652681

RESUMO

BACKGROUND: Giant invasive sacral schwannomas are rare tumors. Surgical excision is the standard treatment and total resection is performed if feasible. Advances in three-dimensional (3D) imaging technology have facilitated treatment designs of complex surgical procedures. OBJECTIVE: Our aim was to evaluate virtual surgical planning, computer-aided design (CAD), and manufacturing with 3D printing technology of the customized osteotomy guiding device in giant invasive sacral schwannoma resection. METHODS: A digital 3D model of the sacrum, including the giant invasive sacral schwannoma, was rendered from patient computer tomography (CT) images. The surgeon chose excision margins of the tumor. Based on the virtual surgical planning, the customized guiding tool for osteotomy was designed and manufactured using the CAD and 3D printing. RESULTS: We used the guiding block to successfully excise a giant sacral schwannoma using only a posterior approach to achieve gross total resection. No augmented spinal instrumentation was used to prevent iatrogenic spinal instability. Clinical symptoms resolved dramatically after operation. No spinal instability occurred during follow-up. CONCLUSION: With the assistance of an image-based customized osteotomy guiding device, we achieved both goals of tumor resection and bone preservation in giant sacral schwannoma resection. With thorough surgical planning, this technology can be applied to the complex surgical procedures easily and reliably.


Assuntos
Desenho Assistido por Computador , Neurilemoma/cirurgia , Osteotomia/métodos , Sacro/cirurgia , Neoplasias da Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/métodos , Feminino , Humanos , Instabilidade Articular/patologia , Neurilemoma/patologia , Osteotomia/instrumentação , Impressão Tridimensional , Tomografia Computadorizada por Raios X , Adulto Jovem
20.
J Oral Maxillofac Surg ; 72(6): 1180.e1-13, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24742699

RESUMO

PURPOSE: A voxel-based median plane (optimal symmetry plane [OSP]) was developed to assess facial bone asymmetry. The purpose of the present study was to introduce a new method of planning surgical correction of facial asymmetry using the OSPs as guides and test its effectiveness. PATIENTS AND METHODS: A retrospective study was conducted of 20 facial asymmetry patients with a mandibular deviation of 4 mm or greater or 4° or more that required surgical correction. In the test group (n = 8), the plans for asymmetry correction were formulated using the matching OSP method, in which the OSPs of the facial bones are tracked and matched during the model surgery setup. In the control group (n = 12), traditional planning was conducted. The traditional plans were cross-checked for symmetry through tracking and revised as needed. The symmetry results of the plans were compared between the 2 groups and within the control group. The outcome measures were the deviation distances between the OSPs of the midface and mandible at the anterior or posterior mandible, the occlusal plane cant, and the angle formed by the 2 OSPs. Surgery was performed in accordance with the final plans, and the results were assessed for symmetry. RESULTS: The traditional plans left a major mandibular deviation in 5 of the 12 control subjects compared with none in the test group. The test group did significantly better than the control group. The revised plans were significantly better than the initial plans. Postoperatively, significant improvements in symmetry were observed. CONCLUSION: The new method resulted in surgical plans that brought about significantly less postoperative mandibular deviation while maintaining a reasonable occlusion.


Assuntos
Assimetria Facial/cirurgia , Processamento de Imagem Assistida por Computador/métodos , Planejamento de Assistência ao Paciente , Cirurgia Assistida por Computador/métodos , Adulto , Estudos de Coortes , Assimetria Facial/diagnóstico , Ossos Faciais/patologia , Feminino , Seguimentos , Mentoplastia/métodos , Síndrome de Goldenhar/diagnóstico , Síndrome de Goldenhar/cirurgia , Humanos , Hiperplasia , Imageamento Tridimensional/métodos , Registro da Relação Maxilomandibular/instrumentação , Masculino , Mandíbula/patologia , Côndilo Mandibular/patologia , Doenças Mandibulares/cirurgia , Neoplasias Mandibulares/cirurgia , Modelos Dentários , Procedimentos Cirúrgicos Ortognáticos/métodos , Estudos Retrospectivos , Tomografia Computadorizada Espiral/métodos , Resultado do Tratamento , Interface Usuário-Computador , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...