Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-942172

RESUMO

OBJECTIVE@#To investigate the clinical features, radiologic scores and clinically relevant risk factors prognosis of secondary interstitial lung disease (ILD) in patients with systemic lupus erythematosus (SLE).@*METHODS@#In this study, 60 SLE patients in Department of Rheumatology of the First Affiliated Hospital of Baotou Medical College and Taizhou First People's Hospital from January 2015 to March 2019 were retrospectively analyzed. All of those 60 patients with SLE underwent lung high resolution computed tomography (HRCT) examination. We used a 1 ∶1 case-control study. There was a matching of age and gender between the two groups. Thirty patients with SLE related ILD (SLE-ILD) were in the case group, and 30 patients with SLE without ILE (SLE non-ILD) were in the control group. The clinical features, pulmonary function test, radiologic characteristic of SLE patients were collected and were used to analyze SLE-ILD.@*RESULTS@#In this study, we reached the following conclusions: First, there were statistically significant differences in chest tightness/shortness of breath, Raynaud's phenomenon, and Velcro rale between SLE-ILD and SLE non-ILD patients (both P < 0.05); Second, hemoglobin (Hb) and albumin (ALB) in the patients of SLE-ILD had a significant decrease compared with the patients of SLE non-ILD. Blood urea nitrogen (BUN), erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) increased in SLE-ILD patients compared with SLE non-ILD patients, the difference had statistical significance (P < 0.05); Third, for SLE-ILD patients, the most common type was non-specific interstitial pneumonia (NSIP), followed by usual interstitial pneumonia and lymphocytic interstitial pneumonia; Fourth, there was no significant difference in clinical-radiology-physiology scores between the different ILD types (P>0.05), similarly, the lung HRCT score and lung function between different ILD types had no significant difference (P>0.05); Fifth, multivariate Logistic regression analysis showed that decreased albumin and chest tightness/shortness of breath might be the risk factor for SLE-ILD.@*CONCLUSION@#There are statistically significant differences between the SLE-ILD group and SLE non-ILD group in terms of chest tightness/shortness of breath, Velcro rale and Raynaud's phenomenon. Decreased albumin and chest tightness/shortness of breath in SLE patients should be alerted to the occurrence of ILD. NSIP is the most common manifestation of SLE-ILD.


Assuntos
Humanos , Estudos de Casos e Controles , Pulmão/diagnóstico por imagem , Doenças Pulmonares Intersticiais/etiologia , Lúpus Eritematoso Sistêmico/complicações , Estudos Retrospectivos
2.
Med Eng Phys ; 37(9): 911-5, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26210779

RESUMO

Aseptic loosening is the primary cause of cementless femoral prosthesis failure and is related to the primary stability of the cementless femoral prosthesis in the femoral cavity. The primary stability affects both the osseointegration and the long-term stability of cementless femoral prostheses. A custom cementless femoral prosthesis can improve the fit and fill of the prosthesis in the femoral cavity and decrease the micromotion of the proximal prosthesis such that the primary stability of the custom prosthesis can be improved, and osseointegration of the proximal prosthesis is achieved. These results will help to achieve long-term stability in total hip arthroplasty (THA). In this paper, we introduce an integrated CAD/CAM/robotic method of milling custom cementless femoral prostheses. The 3D reconstruction model uses femoral CT images and 3D design software to design a CAD model of the custom prosthesis. After the transformation matrices between two units of the robotic system are calibrated, consistency between the CAM software and the robotic system can be achieved, and errors in the robotic milling can be limited. According to the CAD model of the custom prosthesis, the positions of the robotic tool points are produced by the CAM software of the CNC machine. The normal vector of the three adjacent robotic tool point positions determines the pose of the robotic tool point. In conclusion, the fit rate of custom pig femur stems in the femoral cavities was 90.84%. After custom femoral prostheses were inserted into the femoral cavities, the maximum gaps between the prostheses and the cavities measured less than 1 mm at the diaphysis and 1.3 mm at the metaphysis.


Assuntos
Desenho Assistido por Computador , Fêmur , Prótese de Quadril , Desenho de Prótese/métodos , Robótica/métodos , Animais , Artroplastia de Quadril , Interface Osso-Implante , Calibragem , Proteínas de Drosophila , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Imageamento Tridimensional , Modelos Biológicos , Medicina de Precisão/instrumentação , Medicina de Precisão/métodos , Desenho de Prótese/instrumentação , Suínos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...