Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(6)2023 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-36991660

RESUMO

Visible light communications (VLC) is a technology that enables the transmission of digital information with a light source. VLC is nowadays seen as a promising technology for indoor applications, helping WiFi to handle the spectrum crunch. Possible indoor applications range from Internet connection at home/office to multimedia content delivery in a museum. Despite the vast interest of researchers in both theoretical analysis and experimentation on VLC technology, no studies have been carried out on the human perceptions of objects illuminated by VLC-based lamps. It is important to define if a VLC lamp decreases the reading capability or modifies the color perception in order to make VLC a technology appropriate for everyday life use. This paper describes the results of psychophysical tests on humans to define if VLC lamps modify the perception of colors or the reading speed. The results of the reading speed test showed a 0.97 correlation coefficient between tests with and without VLC modulated light, leading us to conclude that there is no difference in the reading speed capability with and without VLC-modulated light. The results of the color perception test showed a Fisher exact test p-value of 0.2351, showing that the perception of color is not influenced by the presence of the VLC modulated light.

2.
Insects ; 12(9)2021 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-34564285

RESUMO

Lipoptena fortisetosa, a deer ked native to Japan, has established itself in several European countries and was recently recorded in Italy. This hippoboscid ectoparasite can develop high density populations, causing annoyance to animals and concern regarding the potential risk of transmitting pathogens to humans. No monitoring or control methods for L. fortisetosa have been applied or tested up to now. This research evaluated the possible response of L. fortisetosa winged adults to different colours as the basis for a monitoring and control strategy. In the summer of 2020, a series of six differently coloured sticky panels were randomly set as traps in a wooded area used by deer for resting. The results indicated a clear preference of the deer ked for the blue panels that caught the highest number of flies during the experimental period. Lower numbers of flies were trapped on the red, green, black, and white panels, with the yellow panels recording the fewest captures. The response clearly demonstrates that this species displays a colour preference, and that coloured traps might be useful for monitoring and limiting this biting ectoparasite in natural areas harbouring wildlife and visited by people.

3.
Eur J Ophthalmol ; 31(5): 2556-2562, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33008267

RESUMO

PURPOSE: To investigate saccadic movements in subjects with eccentric fixation due to a deep central scotoma in Stargardt disease (STGD). METHODS: We studied 10 patients with STGD and 10 healthy subjects (control group). Saccadic movements of all the 20 subjects were assessed by using the eye tracker technique Tobii Glasses Pro 2. Standard measurements of reading ability (MNREAD charts), visual acuity (ETDRS charts), contrast sensitivity (Pelli-Robson charts), reading contrast threshold and speed (REX charts), retinal sensitivity and stability and localization of the fixation (MP1 fundus perimetry) were obtained in all subjects. RESULTS: The saccadic movements time was significantly slower in STGD than in healthy subjects (699 ± 193 ms vs 299 ± 40 ms, p < 0.001). When STGD patients moved fixation to the target localized in retinal scotomatous areas, the movement was significantly slower compared to non scotomatous areas in the retina (1103 ± 798 ms vs 524 ± 187 ms, p = 0.039). There was a trend toward a correlation between slow saccadic movements in STGD subjects and the reading performance indices, although statistical significance was not achieved. CONCLUSION: Ocular saccades guided by eccentric fixation in STGD patients are significantly slower than in the control group, especially when the target corresponds to retinal areas with a deep scotoma. These results can explain the worse reading performance in STGD subjects, in particular when a non-viewing area on the right part of the text is present.


Assuntos
Transtornos da Visão , Testes de Campo Visual , Fixação Ocular , Humanos , Leitura , Escotoma/diagnóstico , Escotoma/etiologia , Doença de Stargardt , Acuidade Visual
4.
Eur J Ophthalmol ; 20(2): 389-96, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19882511

RESUMO

PURPOSE: To investigate the reliability of the Reading Explorer (REX) charts and to assess the impact of text contrast reduction (1.5 cycle/degree) on reading speed in subjects with normal and low vision. METHODS: Standard visual acuity (ETDRS charts), reading speed (MNread charts), and contrast sensitivity (Pelli-Robson charts) measurements were obtained in 3 groups of subjects stratified by visual acuity level in the better eye from 0.0 to 1.0 logMAR, with intermediate cutoffs at 0.3 and 0.6 logMAR. Measurements of reading speed for decreasing levels of text contrast were obtained with the REX charts using a 1.5 cycle/degree text. RESULTS: Since in many patients with lower vision a plateau of maximum reading speed across different levels of text contrast was not found, reliability indexes were computed for average reading speed and reading contrast threshold. In the group with lower visual acuity, 95% limits of agreement were +/-0.134 log word/minute and +/-0.175 log contrast sensitivity, suggesting good reliability. The proportion of subjects with a 20% loss of reading speed from 90% to 45% text contrast was estimated to be 1/3 at 0.6 logMAR visual acuity level and 2/3 at 1.0 logMAR. CONCLUSIONS: The adverse effect of decreased text contrast, which may be found in ordinary reading material, on the reading performance of subjects with advanced and initial low vision is probably underestimated. The REX test proved to be a reliable investigation tool for this phenomenon.


Assuntos
Sensibilidades de Contraste/fisiologia , Leitura , Testes Visuais/métodos , Baixa Visão/fisiopatologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Baixa Visão/diagnóstico , Adulto Jovem
6.
Cogn Process ; 10 Suppl 1: S95-9, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19048318

RESUMO

The term perceptual bistability refers to all those conditions in which an observer looks at an ambiguous stimulus that can have two or more distinct but equally reliable interpretations. In this work, we investigate perception of Necker Cube in which bistability consists of the possibility to interpret the cube depth in two different ways. We manipulated the cube ambiguity by darkening one of the cube faces (cue) to provide a clear cube interpretation due to the occlusion depth index. When the position of the cue is stationary the cube perceived perspective is steady and driven by the cue position. However, when we alternated in time the cue position (i.e. we changed the position of the darkened cube face) two different perceptual phenomena occurred: for low frequencies the cube perspective alternated in line with the position of the cue; however for high frequencies the cue was no longer able to bias the perception but it appears as a floating feature traveling across the solid with the cube whole perspective that returns to be bistable as in the conventional, bias-free, case.


Assuntos
Cognição/fisiologia , Sinais (Psicologia) , Tempo de Reação/fisiologia , Percepção Espacial/fisiologia , Percepção Visual/fisiologia , Adulto , Feminino , Humanos , Masculino , Estimulação Luminosa/métodos , Desempenho Psicomotor/fisiologia , Visão Binocular/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...