Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Proc Math Phys Eng Sci ; 473(2200): 20160861, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28484330

RESUMO

A new wave energy device features a submerged ballasted air bag connected at the top to a rigid float. Under wave action, the bag expands and contracts, creating a reciprocating air flow through a turbine between the bag and another volume housed within the float. Laboratory measurements are generally in good agreement with numerical predictions. Both show that the trajectory of possible combinations of pressure and elevation at which the device is in static equilibrium takes the shape of an S. This means that statically the device can have three different draughts, and correspondingly three different bag shapes, for the same pressure. The behaviour in waves depends on where the mean pressure-elevation condition is on the static trajectory. The captured power is highest for a mean condition on the middle section.

2.
Philos Trans A Math Phys Eng Sci ; 370(1959): 203-7, 2012 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-22184658

RESUMO

The Fourier spectrum of waves in the Pacific Ocean is analysed. The power in 4 s waves is more regular than the power in 10 s waves and larger than expected.

3.
Philos Trans A Math Phys Eng Sci ; 370(1959): 278-87, 2012 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-22184662

RESUMO

A new derivation is given of an equation, relating the capture width of a wave power converter to the polar diagram of the waves generated by the device. The pattern of waves in the lee of the device is calculated in detail.

4.
Philos Trans A Math Phys Eng Sci ; 370(1959): 403-24, 2012 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-22184668

RESUMO

Laboratory measurements of the performance of the Anaconda are presented, a wave energy converter comprising a submerged water-filled distensible tube aligned with the incident waves. Experiments were carried out at a scale of around 1:25 with a 250 mm diameter and 7 m long tube, constructed of rubber and fabric, terminating in a linear power take-off of adjustable impedance. The paper presents some basic theory that leads to predictions of distensibility and bulge wave speed in a pressurized compound rubber and fabric tube, including the effects of inelastic sectors in the circumference, longitudinal tension and the surrounding fluid. Results are shown to agree closely with measurements in still water. The theory is developed further to provide a model for the propagation of bulges and power conversion in the Anaconda. In the presence of external water waves, the theory identifies three distinct internal wave components and provides theoretical estimates of power capture. For the first time, these and other predictions of the behaviour of the Anaconda, a device unlike almost all other marine systems, are shown to be in remarkably close agreement with measurements.

5.
Philos Trans A Math Phys Eng Sci ; 370(1959): 381-402, 2012 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-22184667

RESUMO

A long tube with elastic walls containing water is immersed in the sea aligned in the direction of wave travel. The waves generate bulges that propagate at a speed determined by the distensibility of the tube. If the bulge speed is close to the phase velocity of the waves, there is a resonant transfer of energy from the sea wave to the bulge. At the end of the tube, useful energy can be extracted. This paper sets out the theory of bulge tubes in the sea, and describes some experiments on the model scale and practical problems. The potential of a full-scale device is assessed.

6.
Phys Rev Lett ; 100(9): 091602, 2008 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-18352695

RESUMO

The spin precession frequency of muons stored in the (g-2) storage ring has been analyzed for evidence of Lorentz and CPT violation. Two Lorentz and CPT violation signatures were searched for a nonzero delta omega a(=omega a mu+ - omega a mu-) and a sidereal variation of omega a mu+/-). No significant effect is found, and the following limits on the standard-model extension parameters are obtained: bZ = -(1.0+/-1.1) x 10(-23) GeV; (m mu dZ0 + HXY)=(1.8+/-6.0) x 10(-23) GeV; and the 95% confidence level limits b perpendicular mu+ <1.4 x 10(-24) GeV and b perpendicular mu- <2.6 x 10(-24) GeV.

7.
Phys Rev Lett ; 93(5): 052001, 2004 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-15323687

RESUMO

A new highly sensitive method of looking for electric dipole moments of charged particles in storage rings is described. The major systematic errors inherent in the method are addressed and ways to minimize them are suggested. It seems possible to measure the muon EDM to levels that test speculative theories beyond the standard model.

8.
Phys Rev Lett ; 92(16): 161802, 2004 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-15169217

RESUMO

The anomalous magnetic moment of the negative muon has been measured to a precision of 0.7 ppm (ppm) at the Brookhaven Alternating Gradient Synchrotron. This result is based on data collected in 2001, and is over an order of magnitude more precise than the previous measurement for the negative muon. The result a(mu(-))=11 659 214(8)(3) x 10(-10) (0.7 ppm), where the first uncertainty is statistical and the second is systematic, is consistent with previous measurements of the anomaly for the positive and the negative muon. The average of the measurements of the muon anomaly is a(mu)(exp)=11 659 208(6) x 10(-10) (0.5 ppm).

9.
Phys Rev Lett ; 89(10): 101804, 2002 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-12225185

RESUMO

A higher precision measurement of the anomalous g value, a(mu)=(g-2)/2, for the positive muon has been made at the Brookhaven Alternating Gradient Synchrotron, based on data collected in the year 2000. The result a(mu(+))=11 659 204(7)(5)x10(-10) (0.7 ppm) is in good agreement with previous measurements and has an error about one-half that of the combined previous data. The present world average experimental value is a(mu)(expt)=11 659 203(8)x10(-10) (0.7 ppm).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...