Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Acta Biomed ; 91(3-S): 165-167, 2020 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-32275284

RESUMO

The aim of this study was to evaluate the correlation between the microbial air contamination values obtained by active sampling (colony-forming units per cubic metre, CFU/m3) and by passive sampling (Index of microbial air contamination, IMA) and to calculate the corresponding equations. Air sampling was performed in ten dental clinics (DC), before (T0), during (T1) and after (T2) the clinical activity, for five consecutive days, once a month for a period of three months, for a total of 450 air samplings. The correlation was evaluated using the Spearman test, and a p value below 0.05 was considered statistically significant. A statistically significant correlation was found considering both the results obtained from the total observations and from the single sampling times, T0, T1 and T2. Different correlation patterns were observed stratifying by DC. Both methods were able to evaluate the microbial air quality and highlight critical situations; therefore, both can be used with this aim. However, in particular during the activity, passive sampling resulted more sensitive, and for its simplicity, economy and standardization by IMA, as suggested by several authors, can be suggested for routine monitoring.


Assuntos
Microbiologia do Ar , Clínicas Odontológicas , Monitoramento Ambiental/métodos , Contagem de Colônia Microbiana , Correlação de Dados
2.
BMC Infect Dis ; 18(1): 583, 2018 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-30453892

RESUMO

BACKGROUND: Environmental cleaning practice plays an important role in reducing microbial contamination in hospital surfaces and contributes to prevent Healthcare Associated Infections. Adenosine Triphosphate (ATP) bioluminescence assay is a commonly used method for assessing environmental cleanliness on healthcare surfaces. This study tested the feasibility of using ATP-bioluminescence assay for evaluating the efficiency of cleaning procedures in the operating theatre settings, comparing the ATP-bioluminescence test with the traditional culture method. METHODS: The surfaces of 10 operating rooms of two public hospitals (140 samples in total) were examined "at rest", in two moments of the same daily session: before the first scheduled operation (Pre), and before the second, after a clean environment was re-established (Post). Surface contamination was assessed using the cultural method to detect Total Viable Counts (TVC36°C) and ATP-bioluminescence assay (RLU). RESULTS: The examined surfaces presented very low TVCs (geometric means: 1.8 CFU/plate; IC95%: 1.6-2.0), always compliant with the relative reference standards. No statistical correlation was found between ATP values and TVCs. However, considering the results in terms of general evaluation of hygienic quality of surfaces, the two methods were consistent in identifying the most contaminated areas (Hospital A > Hospital B; Pre > Post; most contaminated surfaces: scialytic lamp). Furthermore, the ATP mean values showed a progressive increase from surfaces with TVC = 0 to surfaces with TVC > 15 CFU/plate. CONCLUSIONS: Although not an alternative to cultural methods, the ATP-bioluminescence-assay can be a useful tool to measure the efficiency of cleaning procedures also in environments with very low microbial counts. Each health facility should identify appropriate reference values, depending on the devices used and on the basis of the analysis of the data collected through spatial and temporal sampling series. By providing a rapid feedback, the ATP-assay helps to increase the awareness of operators and allows immediate action to be taken in critical situations.


Assuntos
Trifosfato de Adenosina/análise , Descontaminação/normas , Higiene , Controle de Infecções/normas , Medições Luminescentes/métodos , Salas Cirúrgicas , Bioensaio , Contagem de Colônia Microbiana , Descontaminação/métodos , Estudos de Viabilidade , Hospitais/normas , Humanos , Controle de Infecções/métodos , Salas Cirúrgicas/normas , Prática Profissional/normas
3.
Am J Infect Control ; 46(2): 169-172, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28967509

RESUMO

AIM: The study reports a 2-year single-center experience of the practice of skin antisepsis using a 0.05% sodium hypochlorite solution before central venous catheter placement in neonates. METHODS: Eligible subjects included any hospitalized neonate who needed a central line for at least 48 hours. Infants were excluded if they had a generalized or localized skin disorder. An ad hoc Excel (Microsoft Corp, Redmond, WA) file was used to record the data from each patient. The catheter sites were monitored daily for the presence of contact dermatitis. Central line-associated bloodstream infection was diagnosed according to Centers for Disease Control and Prevention definition. RESULTS: One hundred five infants underwent central venous catheter placement and were enrolled. A total of 198 central lines were inserted. The median gestational age was 31 weeks (range, 23-41 weeks) and median birth weight was 1,420 g (range, 500-5,170 g). There were no signs of 0.05% sodium hypochlorite-related skin toxicity in any infant. Of 198 catheters (1,652 catheter-days) prospectively studied, 9 were associated with bloodstream infections (5.4 per 1,000 catheter-days). CONCLUSION: During the observation period, no local adverse effects were observed suggesting that 0.05% sodium hypochlorite may be a safe choice in this context.


Assuntos
Antissepsia/métodos , Infecções Relacionadas a Cateter/prevenção & controle , Cateterismo Venoso Central/efeitos adversos , Hipoclorito de Sódio/farmacologia , Anti-Infecciosos Locais , Cateteres de Demora/efeitos adversos , Feminino , Humanos , Recém-Nascido , Masculino
4.
Artigo em Inglês | MEDLINE | ID: mdl-29283367

RESUMO

The microbiological contamination of operating theatres and the lack of adherence to best practices by surgical staff represent some of the factors affecting Surgical Site Infections (SSIs). The aim of the present study was to assess the microbiological quality of operating settings and the staff compliance to the SSI evidence-based control measures. Ten operating rooms were examined for microbiological contamination of air and surfaces, after cleaning procedures, in "at rest" conditions. Furthermore, 10 surgical operations were monitored to assess staff compliance to the recommended practices. None of the air samples exceeded microbiological reference standards and only six of the 200 surface samples (3.0%) were slightly above recommended levels. Potentially pathogenic bacteria and moulds were never detected. Staff compliance to best practices varied depending on the type of behaviour investigated and the role of the operator. The major not compliant behaviours were: pre-operative skin antisepsis, crowding of the operating room and hand hygiene of the anaesthetist. The good environmental microbiological quality observed is indicative of the efficacy of the cleaning-sanitization procedures adopted. The major critical point was staff compliance to recommended practices. Awareness campaigns are therefore necessary, aimed at improving the organisation of work so as to facilitate compliance to operative protocols.


Assuntos
Controle de Infecções/organização & administração , Salas Cirúrgicas/organização & administração , Microbiologia do Ar , Aglomeração , Higiene das Mãos , Humanos , Padrões de Referência , Infecção da Ferida Cirúrgica/prevenção & controle
5.
Artigo em Inglês | MEDLINE | ID: mdl-28075419

RESUMO

Clostridium difficile is an emerging cause of healthcare associated infections. In nine hospitals of an Italian Local Health Authority the episodes of C. difficile infection (CDI) were identified using the data registered by the centralized Laboratory Information System, from 2010 to 2015. CDI incidence (positive patients for A and/or B toxins per patients-days) was analysed per year, hospital, and ward. A number of cases approximately equivalent to the mean of identified cases per year were studied retrospectively to highlight the risk factors associated to CDI and their severity. Nine hundred and forty-two patients affected by CDI were identified. The overall incidence was 3.7/10,000 patients-days, with a stable trend across the six years and the highest rates observed in smaller and outlying hospitals (up to 17.8/10,000), where the admitted patients were older and the wards with the highest incidences (long-term-care: 7.6/10,000, general medicine: 5.7/10,000) were more represented. The mean age of patients in each hospital was correlated with CDI rates. Of the 101 cases selected for the retrospective study, 86.1% were healthcare associated, 10.9% community acquired; 9.1% met the criteria for recurrent case and 23.8% for severe case of CDI. The overall mortality rate was 28.7%. Comorbidity conditions occurred in 91.1%, previous exposure to antibiotics in 76.2%, and proton pump inhibitors in 77.2%. Recurrent and severe cases were significantly associated with renal insufficiency and creatinine levels ≥2 mg/dL. The survey based on the centralized laboratory data was useful to study CDI epidemiology in the different centres in order to identify possible weaknesses and plan control strategies, in particular the reinforcement of staff training, mainly targeted at compliance with contact precautions and hand hygiene.


Assuntos
Clostridioides difficile , Infecções por Clostridium/epidemiologia , Infecção Hospitalar/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Clostridioides difficile/isolamento & purificação , Infecções por Clostridium/prevenção & controle , Infecção Hospitalar/prevenção & controle , Monitoramento Epidemiológico , Fezes/microbiologia , Feminino , Hospitalização , Hospitais/estatística & dados numéricos , Humanos , Incidência , Controle de Infecções/métodos , Itália/epidemiologia , Masculino , Inibidores da Bomba de Prótons/uso terapêutico , Estudos Retrospectivos , Fatores de Risco
6.
Int J Environ Res Public Health ; 11(2): 2064-76, 2014 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-24552789

RESUMO

Output water from dental unit waterlines (DUWLs) may be a potential source of infection for both dental healthcare staff and patients. This study compared the efficacy of different disinfection methods with regard to the water quality and the presence of biofilm in DUWLs. Five dental units operating in a public dental health care setting were selected. The control dental unit had no disinfection system; two were disinfected intermittently with peracetic acid/hydrogen peroxide 0.26% and two underwent continuous disinfection with hydrogen peroxide/silver ions (0.02%) and stabilized chlorine dioxide (0.22%), respectively. After three months of applying the disinfection protocols, continuous disinfection systems were more effective than intermittent systems in reducing the microbial contamination of the water, allowing compliance with the CDC guidelines and the European Council regulatory thresholds for drinking water. P. aeruginosa, Legionella spp, sulphite-reducing Clostridium spores, S. aureus and ß-haemolytic streptococci were also absent from units treated with continuous disinfection. The biofilm covering the DUWLs was more extensive, thicker and more friable in the intermittent disinfection dental units than in those with continuous disinfection. Overall, the findings showed that the products used for continuous disinfection of dental unit waterlines showed statistically better results than the intermittent treatment products under the study conditions.


Assuntos
Equipamentos Odontológicos/microbiologia , Desinfecção/métodos , Microbiologia da Água , Biofilmes , Odontologia Comunitária , Água Potável/normas
7.
Int J Infect Dis ; 17(9): e714-7, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23528638

RESUMO

OBJECTIVE: The identification of patients colonized or infected with carbapenemase-producing Enterobacteriaceae (CPE), in order to control and prevent the global spread of multidrug-resistant (MDR) pathogens. METHODS: From June 1 to June 15, 2012, eight Citrobacter freundii strains with reduced susceptibility to carbapenems were isolated from rectal swabs of hospitalized patients during active screening following the detection of a Klebsiella pneumoniae carbapenemase (KPC) -positive patient on the ward. All isolates were analyzed phenotypically and molecularly by PCR and sequencing. Genotype clustering was performed by multilocus sequence typing (MLST) analysis. RESULTS: The isolates showed high rates of multidrug resistance profile. A phenotypic assay for carbapenemase production suggested the presence of metallo-ß-lactamase (MBL). The blaVIM-1 gene was detected in all imipenem-resistant C. freundii isolates. MLST showed that the C. freundii isolates shared the same sequence type (ST). Phylogenetic analysis revealed a strict relationship with an ST5C. freundii isolate from a diarrhea patient in China. CONCLUSIONS: Our findings showed that the active surveillance program for CPE was useful, not only for the detection of KPC-producers, but also to identify and control the spread of other MDR pathogens that could expand the spectrum of circulating MDR pathogens.


Assuntos
Citrobacter freundii/genética , Infecção Hospitalar/epidemiologia , Surtos de Doenças , Infecções por Enterobacteriaceae/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/farmacologia , Citrobacter freundii/classificação , Citrobacter freundii/efeitos dos fármacos , Infecção Hospitalar/microbiologia , Infecções por Enterobacteriaceae/microbiologia , Feminino , Hospitais , Humanos , Itália/epidemiologia , Masculino , Testes de Sensibilidade Microbiana , Tipagem de Sequências Multilocus , Filogenia , beta-Lactamases/genética
8.
Int J Environ Res Public Health ; 10(3): 808-15, 2013 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-23442560

RESUMO

Klebsiella pneumoniae is a frequent cause of infectious outbreaks in Neonatal Intensive Care Units (NICUs). The aim of this paper is to describe an outbreak occurred in a 13-bed NICU and the control measures adopted in order to interrupt the chain of transmission. We described the microbiological investigations, the NICU staff compliance to the infection control measures by means of a specifically designed check-list and the control measures adopted. Six cases of primary bloodstream infections sustained by ampicillin/piperacillin-resistant Klebsiella pneumoniae were observed over a two-month period. One culture obtained from a 12% saccarose multiple-dose solution allowed the growth of Klebsiella pneumoniae. During the inspections performed by the Hospital Infection Control Team, using the check-list for the evaluation of the NICU staff compliance to the infection control measures, several breaches in the infection control policy were identified and control measures were adopted. In our case the definition of a specific check-list led to the adoption of the correct control measures. Further studies would be helpful in order to develop a standard check-list able to identify critical flows in the adhesion to the guidelines. It could be used in different NICUs and allow to obtain reproducible levels of infection control.


Assuntos
Infecção Hospitalar/prevenção & controle , Controle de Infecções , Infecções por Klebsiella/prevenção & controle , Klebsiella pneumoniae , Ampicilina , Antibacterianos , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/microbiologia , DNA Bacteriano/análise , Surtos de Doenças , Farmacorresistência Bacteriana Múltipla , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Controle de Infecções/métodos , Unidades de Terapia Intensiva Neonatal , Infecções por Klebsiella/epidemiologia , Infecções por Klebsiella/microbiologia , Klebsiella pneumoniae/genética , Klebsiella pneumoniae/isolamento & purificação , Masculino , Testes de Sensibilidade Microbiana , Piperacilina
9.
Sci Total Environ ; 420: 289-99, 2012 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-22335883

RESUMO

A microbiological environmental investigation was carried out in ten dental clinics in Italy. Microbial contamination of water, air and surfaces was assessed in each clinic during the five working days, for one week per month, for a three-month period. Water and surfaces were sampled before and after clinical activity; air was sampled before, after, and during clinical activity. A wide variation was found in microbial environmental contamination, both within the participating clinics and for the different sampling times. Before clinical activity, microbial water contamination in tap water reached 51,200cfu/mL (colony forming units per milliliter), and that in Dental Unit Water Systems (DUWSs) reached 872,000cfu/mL. After clinical activity, there was a significant decrease in the Total Viable Count (TVC) in tap water and in DUWSs. Pseudomonas aeruginosa was found in 2.38% (7/294) of tap water samples and in 20.06% (59/294) of DUWS samples; Legionella spp. was found in 29.96% (89/297) of tap water samples and 15.82% (47/297) of DUWS samples, with no significant difference between pre- and post-clinical activity. Microbial air contamination was highest during dental treatments, and decreased significantly at the end of the working activity (p<0.05). The microbial buildup on surfaces increased significantly during the working hours. This study provides data for the establishment of standardized sampling methods, and threshold values for contamination monitoring in dentistry. Some very critical situations have been observed which require urgent intervention. Furthermore, the study emphasizes the need for research aimed at defining effective managing strategies for dental clinics.


Assuntos
Microbiologia do Ar , Clínicas Odontológicas , Monitoramento Ambiental/normas , Contaminação de Equipamentos , Microbiologia da Água , Equipamentos Odontológicos/microbiologia , Humanos , Itália , Níveis Máximos Permitidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...