Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dis Model Mech ; 16(12)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37942584

RESUMO

Sepsis-associated acute kidney injury is associated with high morbidity and mortality in critically ill patients. Cell-free hemoglobin (CFH) is released into the circulation of patients with severe sepsis and the levels of CFH are independently associated with mortality. CFH treatment increased cytotoxicity in the human tubular epithelial cell line HK-2. To better model the intact kidney, we cultured human kidney organoids derived from induced pluripotent stem cells. We treated human kidney organoids grown using both three-dimensional and transwell protocols with CFH for 48 h. We found evidence for increased tubular toxicity, oxidative stress, mitochondrial fragmentation, endothelial cell injury and injury-associated transcripts compared to those of the untreated control group. To evaluate the protective effect of clinically available small molecules, we co-treated CFH-injured organoids with ascorbate (vitamin C) or acetaminophen for 48 h. We found significantly decreased toxicity, preservation of endothelial cells and reduced mitochondrial fragmentation in the group receiving ascorbate following CFH treatment. This study provides direct evidence that ascorbate or ascorbic acid protects human kidney cells from CFH-induced damage such as that in sepsis-associated acute kidney injury.


Assuntos
Injúria Renal Aguda , Sepse , Humanos , Células Endoteliais/metabolismo , Rim/metabolismo , Ácido Ascórbico/farmacologia , Ácido Ascórbico/metabolismo , Hemoglobinas/farmacologia , Hemoglobinas/metabolismo , Sepse/complicações , Sepse/tratamento farmacológico , Sepse/metabolismo , Injúria Renal Aguda/tratamento farmacológico
2.
J Vasc Access ; : 11297298231153716, 2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36765464

RESUMO

INTRODUCTION: Central venous catheters (CVCs) are often trimmed during heart transplantation and pediatric cardiac surgery. However, the risk of endothelial injury caused by the cut tip of the CVC has not been evaluated. We hypothesized that there is no difference in the degree of endothelial injury associated with trimmed CVCs versus standard untrimmed CVCs. METHODS: In four adult male sheep, the left external jugular vein was exposed in three segments, one designated for an untouched control group, one for the trimmed CVC group, and one for the untrimmed CVC group. Trimmed and untrimmed CVC tips were rotated circumferentially within their respective segments to abrade the lumen of the vein. The vein samples were explanted, and two representative sections from each sample were analyzed using hematoxylin and eosin (H&E) staining, as well as with immunohistochemistry against CD31, von Willebrand factor (vWF), endothelial nitric oxide synthase (eNOS), and caveolin. Higher immunohistochemical stain distributions and intensities are associated with normal health and function of the venous endothelium. Data are presented as counts with percentages or as means with standard error. RESULTS: H&E staining revealed no evidence of endothelial injury in 6/8 (75%) samples from the untouched control group, and no injury in 4/8 (50%) samples from both the trimmed and untrimmed CVC groups (p = 0.504). In all remaining samples from each group, only mild endothelial injury was observed. Immunohistochemical analysis comparing trimmed CVCs versus untrimmed CVCs revealed no difference in the percentage of endothelial cells staining positive for CD31 (57.5% ± 7.2% vs 55.0% ± 9.2%, p = 0.982), vWF (73.8% ± 8.0% vs 62.5% ± 9.6%, p = 0.579), eNOS (66.3% ± 4.2% vs 63.8% ± 7.5%, p = 0.962), and caveolin (53.8% ± 5.0% vs 51.3% ± 4.4%, p = 0.922). There were no significant differences between the groups in the distributions of stain intensity for CD31, vWF, eNOS, and caveolin. CONCLUSION: Trimmed CVCs do not increase endothelial injury compared to standard untrimmed CVCs.

3.
Stem Cell Res Ther ; 13(1): 355, 2022 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-35883199

RESUMO

BACKGROUND: In diabetic kidney disease, high glucose damages specialized cells called podocytes that filter blood in the glomerulus. In vitro culture of podocytes is crucial for modeling of diabetic nephropathy and genetic podocytopathies and to complement animal studies. Recently, several methods have been published to derive podocytes from human-induced pluripotent stem cells (iPSCs) by directed differentiation. However, these methods have major variations in media composition and have not been compared. METHODS: We characterized our accelerated protocol by guiding the cells through differentiation with four different medias into MIXL1+ primitive streak cells with Activin A and CHIR for Wnt activation, intermediate mesoderm PAX8+ cells via increasing the CHIR concentration, nephron progenitors with FGF9 and Heparin for stabilization, and finally into differentiated podocytes with Activin A, BMP-7, VEGF, reduced CHIR, and retinoic acid. The podocyte morphology was characterized by scanning and transmission electron microscopy and by flow cytometry analysis for podocyte markers. To confirm cellular identity and niche localization, we performed cell recombination assays combining iPSC-podocytes with dissociated mouse embryonic kidney cells. Finally, to test iPSC-derived podocytes for the modeling of diabetic kidney disease, human podocytes were exposed to high glucose. RESULTS: Podocyte markers were expressed at similar or higher levels for our accelerated protocol as compared to previously published protocols that require longer periods of tissue culture. We confirmed that the human podocytes derived from induced pluripotent stem cells in twelve days integrated into murine glomerular structures formed following seven days of culture of cellular recombinations. We found that the high glucose-treated human podocytes displayed actin rearrangement, increased cytotoxicity, and decreased viability. CONCLUSIONS: We found that our accelerated 12-day method for the differentiation of podocytes from human-induced pluripotent stem cells yields podocytes with comparable marker expression to longer podocytes. We also demonstrated that podocytes created with this protocol have typical morphology by electron microscopy. The podocytes have utility for diabetes modeling as evidenced by lower viability and increased cytotoxicity when treated with high glucose. We found that multiple, diverse methods may be utilized to create iPSC-podocytes, but closely mimicking developmental cues shortened the time frame required for differentiation.


Assuntos
Diabetes Mellitus , Nefropatias Diabéticas , Células-Tronco Pluripotentes Induzidas , Podócitos , Animais , Diabetes Mellitus/metabolismo , Nefropatias Diabéticas/metabolismo , Glucose/metabolismo , Glucose/farmacologia , Humanos , Células-Tronco Pluripotentes Induzidas/metabolismo , Glomérulos Renais/metabolismo , Camundongos , Podócitos/metabolismo
4.
J Mech Behav Biomed Mater ; 126: 105074, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35030471

RESUMO

After myocardial infarction (MI), adult mammals exhibit scar formation, adverse left ventricular (LV) remodeling, LV stiffening, and impaired contractility, ultimately resulting in heart failure. Neonatal mammals, however, are capable of natural heart regeneration after MI. We hypothesized that neonatal cardiac regeneration conserves native biaxial LV mechanics after MI. Wistar rat neonates (1 day old, n = 46) and adults (8-10 weeks old, n = 20) underwent sham surgery or permanent left anterior descending coronary artery ligation. At 6 weeks after neonatal MI, Masson's trichrome staining revealed negligible fibrosis. Echocardiography for the neonatal MI (n = 15) and sham rats (n = 14) revealed no differences in LV wall thickness or chamber diameter, and both groups had normal ejection fraction (72.7% vs 77.5%, respectively, p = 0.1946). Biaxial tensile testing revealed similar stress-strain curves along both the circumferential and longitudinal axes across a full range of physiologic stresses and strains. The circumferential modulus (267.9 kPa vs 274.2 kPa, p = 0.7847), longitudinal modulus (269.3 kPa vs 277.1 kPa, p = 0.7435), and maximum shear stress (3.30 kPa vs 3.95 kPa, p = 0.5418) did not differ significantly between the neonatal MI and sham groups, respectively. In contrast, transmural scars were observed at 4 weeks after adult MI. Adult MI hearts (n = 7) exhibited profound LV wall thinning (p < 0.0001), chamber dilation (p = 0.0246), and LV dysfunction (ejection fraction 45.4% vs 79.7%, p < 0.0001) compared to adult sham hearts (n = 7). Adult MI hearts were significantly stiffer than adult sham hearts in both the circumferential (321.5 kPa vs 180.0 kPa, p = 0.0111) and longitudinal axes (315.4 kPa vs 172.3 kPa, p = 0.0173), and also exhibited greater maximum shear stress (14.87 kPa vs 3.23 kPa, p = 0.0162). Our study is the first to show that native biaxial LV mechanics are conserved after neonatal heart regeneration following MI, thus adding biomechanical support for the therapeutic potential of cardiac regeneration in the treatment of ischemic heart disease.


Assuntos
Infarto do Miocárdio , Animais , Animais Recém-Nascidos , Fenômenos Biomecânicos , Cicatriz/patologia , Modelos Animais de Doenças , Infarto do Miocárdio/patologia , Miocárdio/patologia , Ratos , Ratos Wistar , Remodelação Ventricular
5.
J Thorac Cardiovasc Surg ; 163(2): e161-e171, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-32747120

RESUMO

OBJECTIVE: The objective was to design and evaluate a clinically relevant, novel ex vivo bicuspid aortic valve model that mimics the most common human phenotype with associated aortic regurgitation. METHODS: Three bovine aortic valves were mounted asymmetrically in a previously validated 3-dimensional-printed left heart simulator. The non-right commissure and the non-left commissure were both shifted slightly toward the left-right commissure, and the left and right coronary cusps were sewn together. The left-right commissure was then detached and reimplanted 10 mm lower than its native height. Free margin shortening was used for valve repair. Hemodynamic status, high-speed videography, and echocardiography data were collected before and after the repair. RESULTS: The bicuspid aortic valve model was successfully produced and repaired. High-speed videography confirmed prolapse of the fused cusp of the baseline bicuspid aortic valve models in diastole. Hemodynamic and pressure data confirmed accurate simulation of diseased conditions with aortic regurgitation and the subsequent repair. Regurgitant fraction postrepair was significantly reduced compared with that at baseline (14.5 ± 4.4% vs 28.6% ± 3.4%; P = .037). There was no change in peak velocity, peak gradient, or mean gradient across the valve pre- versus postrepair: 293.3 ± 18.3 cm/sec versus 325.3 ± 58.2 cm/sec (P = .29), 34.3 ± 4.2 mm Hg versus 43.3 ± 15.4 mm Hg (P = .30), and 11 ± 1 mm Hg versus 9.3 ± 2.5 mm Hg (P = .34), respectively. CONCLUSIONS: An ex vivo bicuspid aortic valve model was designed that recapitulated the most common human phenotype with aortic regurgitation. These valves were successfully repaired, validating its potential for evaluating valve hemodynamics and optimizing surgical repair for bicuspid aortic valves.


Assuntos
Insuficiência da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Procedimentos Cirúrgicos Cardiovasculares , Modelos Anatômicos , Animais , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/patologia , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/patologia , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Doença da Válvula Aórtica Bicúspide/cirurgia , Procedimentos Cirúrgicos Cardiovasculares/educação , Procedimentos Cirúrgicos Cardiovasculares/métodos , Bovinos , Ecocardiografia , Hemodinâmica , Humanos
6.
J Cardiovasc Transl Res ; 14(2): 283-289, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32495264

RESUMO

Although ex vivo simulation is a valuable tool for surgical optimization, a disease model that mimics human aortic regurgitation (AR) from cusp prolapse is needed to accurately examine valve biomechanics. To simulate AR, four porcine aortic valves were explanted, and the commissure between the two largest leaflets was detached and re-implanted 5 mm lower to induce cusp prolapse. Four additional valves were tested in their native state as controls. All valves were tested in a heart simulator while hemodynamics, high-speed videography, and echocardiography data were collected. Our AR model successfully reproduced cusp prolapse with significant increase in regurgitant volume compared with that of the controls (23.2 ± 8.9 versus 2.8 ± 1.6 ml, p = 0.017). Hemodynamics data confirmed the simulation of physiologic disease conditions. Echocardiography and color flow mapping demonstrated the presence of mild to moderate eccentric regurgitation in our AR model. This novel AR model has enormous potential in the evaluation of valve biomechanics and surgical repair techniques. Graphical Abstract.


Assuntos
Insuficiência da Valva Aórtica/fisiopatologia , Prolapso da Valva Aórtica/fisiopatologia , Valva Aórtica/fisiopatologia , Hemodinâmica , Modelos Cardiovasculares , Animais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Prolapso da Valva Aórtica/diagnóstico por imagem , Fenômenos Biomecânicos , Ecocardiografia Doppler em Cores , Desenho de Equipamento , Técnicas In Vitro , Impressão Tridimensional , Sus scrofa , Técnicas de Sutura , Transdutores de Pressão
7.
J Thorac Cardiovasc Surg ; 161(5): 1776-1783, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32249088

RESUMO

OBJECTIVE: Barlow's disease remains challenging to repair, given the complex valvular morphology and lack of quantitative data to compare techniques. Although there have been recent strides in ex vivo evaluation of cardiac mechanics, to our knowledge, there is no disease model that accurately simulates the morphology and pathophysiology of Barlow's disease. The purpose of this study was to design such a model. METHODS: To simulate Barlow's disease, a cross-species ex vivo model was developed. Bovine mitral valves (n = 4) were sewn into a porcine annulus mount to create excess leaflet tissue and elongated chordae. A heart simulator generated physiologic conditions while hemodynamic data, high-speed videography, and chordal force measurements were collected. The regurgitant valves were repaired using nonresectional repair techniques such as neochord placement. RESULTS: The model successfully imitated the complexities of Barlow's disease, including redundant, billowing bileaflet tissues with notable regurgitation. After repair, hemodynamic data confirmed reduction of mitral leakage volume (25.9 ± 2.9 vs 2.1 ± 1.8 mL, P < .001) and strain gauge analysis revealed lower primary chordae forces (0.51 ± 0.17 vs 0.10 ± 0.05 N, P < .001). In addition, the maximum rate of change of force was significantly lower postrepair for both primary (30.80 ± 11.38 vs 8.59 ± 4.83 N/s, P < .001) and secondary chordae (33.52 ± 10.59 vs 19.07 ± 7.00 N/s, P = .006). CONCLUSIONS: This study provides insight into the biomechanics of Barlow's disease, including sharply fluctuating force profiles experienced by elongated chordae prerepair, as well as restoration of primary chordae forces postrepair. Our disease model facilitates further in-depth analyses to optimize the repair of Barlow's disease.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Prolapso da Valva Mitral , Valva Mitral , Modelos Cardiovasculares , Animais , Fenômenos Biomecânicos/fisiologia , Bovinos , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/fisiopatologia , Prolapso da Valva Mitral/cirurgia , Suínos
8.
Tissue Eng Part A ; 27(5-6): 328-335, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32703108

RESUMO

Cell sheet technology using UpCell™ (Thermo Fisher Scientific, Roskilde, Denmark) plates is a modern tool that enables the rapid creation of single-layered cells without using extracellular matrix (ECM) enzymatic digestion. Although this technique has the advantage of maintaining a sheet of cells without needing artificial scaffolds, these cell sheets remain extremely fragile. Collagen, the most abundant ECM component, is an attractive candidate for modulating tissue mechanical properties given its tunable property. In this study, we demonstrated rapid mechanical property augmentation of human dermal fibroblast cell sheets after incubation with bovine type I collagen for 24 h on UpCell plates. We showed that treatment with collagen resulted in increased collagen I incorporation within the cell sheet without affecting cell morphology, cell type, or cell sheet quality. Atomic force microscopy measurements for controls, and cell sheets that received 50 and 100 µg/mL collagen I treatments revealed an average Young's modulus of their respective intercellular regions: 6.6 ± 1.0, 14.4 ± 6.6, and 19.8 ± 3.8 kPa during the loading condition, and 10.3 ± 4.7, 11.7 ± 2.2, and 18.1 ± 3.4 kPa during the unloading condition. This methodology of rapid mechanical property augmentation of a cell sheet has a potential impact on cell sheet technology by improving the ease of construct manipulation, enabling new translational tissue engineering applications.


Assuntos
Colágeno , Engenharia Tecidual , Animais , Bovinos , Módulo de Elasticidade , Matriz Extracelular , Fibroblastos , Humanos
9.
J R Soc Interface ; 17(173): 20200614, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33259750

RESUMO

Papillary muscles serve as attachment points for chordae tendineae which anchor and position mitral valve leaflets for proper coaptation. As the ventricle contracts, the papillary muscles translate and rotate, impacting chordae and leaflet kinematics; this motion can be significantly affected in a diseased heart. In ex vivo heart simulation, an explanted valve is subjected to physiologic conditions and can be adapted to mimic a disease state, thus providing a valuable tool to quantitatively analyse biomechanics and optimize surgical valve repair. However, without the inclusion of papillary muscle motion, current simulators are limited in their ability to accurately replicate cardiac biomechanics. We developed and implemented image-guided papillary muscle (IPM) robots to mimic the precise motion of papillary muscles. The IPM robotic system was designed with six degrees of freedom to fully capture the native motion. Mathematical analysis was used to avoid singularity conditions, and a supercomputing cluster enabled the calculation of the system's reachable workspace. The IPM robots were implemented in our heart simulator with motion prescribed by high-resolution human computed tomography images, revealing that papillary muscle motion significantly impacts the chordae force profile. Our IPM robotic system represents a significant advancement for ex vivo simulation, enabling more reliable cardiac simulations and repair optimizations.


Assuntos
Insuficiência da Valva Mitral , Robótica , Biomimética , Cordas Tendinosas , Humanos , Músculos Papilares
10.
Circulation ; 142(14): 1361-1373, 2020 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-33017215

RESUMO

BACKGROUND: Many graft configurations are clinically used for valve-sparing aortic root replacement, some specifically focused on recapitulating neosinus geometry. However, the specific impact of such neosinuses on valvular and root biomechanics and the potential influence on long-term durability are unknown. METHODS: Using a custom 3-dimenstional-printed heart simulator with porcine aortic roots (n=5), the anticommissural plication, Stanford modification, straight graft (SG), Uni-Graft, and Valsalva graft configurations were tested in series using an incomplete counterbalanced measures design, with the native root as a control, to mitigate ordering effects. Hemodynamic and videometric data were analyzed using linear models with conduit as the fixed effect of interest and valve as a fixed nuisance effect with post hoc pairwise testing using Tukey's correction. RESULTS: Hemodynamics were clinically similar between grafts and control aortic roots. Regurgitant fraction varied between grafts, with SG and Uni-Graft groups having the lowest regurgitant fractions and anticommissural plication having the highest. Root distensibility was significantly lower in SG versus both control roots and all other grafts aside from the Stanford modification (P≤0.01 for each). All grafts except SG had significantly higher cusp opening velocities versus native roots (P<0.01 for each). Relative cusp opening forces were similar between SG, Uni-Graft, and control groups, whereas anticommissural plication, Stanford modification, and Valsalva grafts had significantly higher opening forces versus controls (P<0.01). Cusp closing velocities were similar between native roots and the SG group, and were significantly lower than observed in the other conduits (P≤0.01 for each). Only SG and Uni-Graft groups experienced relative cusp closing forces approaching that of the native root, whereas relative forces were >5-fold higher in the anticommissural plication, Stanford modification, and Valsalva graft groups. CONCLUSIONS: In this ex vivo modeling system, clinically used valve-sparing aortic root replacement conduit configurations have comparable hemodynamics but differ in biomechanical performance, with the straight graft most closely recapitulating native aortic root biomechanics.


Assuntos
Aorta/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese Vascular , Prótese Vascular , Modelos Cardiovasculares , Impressão Tridimensional , Animais , Humanos , Suínos
11.
Microb Biotechnol ; 13(6): 1780-1792, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32476224

RESUMO

The cyanobacterium Synechococcus elongatus (SE) has been shown to rescue ischaemic heart muscle after myocardial infarction by photosynthetic oxygen production. Here, we investigated SE toxicity and hypothesized that systemic SE exposure does not elicit a significant immune response in rats. Wistar rats intravenously received SE (n = 12), sterile saline (n = 12) or E. coli lipopolysaccharide (LPS, n = 4), and a subset (8 SE, 8 saline) received a repeat injection 4 weeks later. At baseline, 4 h, 24 h, 48 h, 8 days and 4 weeks after injection, clinical assessments, blood cultures, blood counts, lymphocyte phenotypes, liver function tests, proinflammatory cytokines and immunoglobulins were assessed. Across all metrics, SE rats responded comparably to saline controls, displaying no clinically significant immune response. As expected, LPS rats exhibited severe immunological responses. Systemic SE administration does not induce sepsis or toxicity in rats, thereby supporting the safety of cyanobacteria-mammalian symbiotic therapeutics using this organism.


Assuntos
Escherichia coli , Synechococcus , Animais , Fotossíntese , Ratos , Ratos Wistar
12.
Sci Rep ; 10(1): 7319, 2020 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-32355240

RESUMO

Neonatal mice exhibit natural heart regeneration after myocardial infarction (MI) on postnatal day 1 (P1), but this ability is lost by postnatal day 7 (P7). Cardiac biomechanics intricately affect long-term heart function, but whether regenerated cardiac muscle is biomechanically similar to native myocardium remains unknown. We hypothesized that neonatal heart regeneration preserves native left ventricular (LV) biomechanical properties after MI. C57BL/6J mice underwent sham surgery or left anterior descending coronary artery ligation at age P1 or P7. Echocardiography performed 4 weeks post-MI showed that P1 MI and sham mice (n = 22, each) had similar LV wall thickness, diameter, and ejection fraction (59.6% vs 60.7%, p = 0.6514). Compared to P7 shams (n = 20), P7 MI mice (n = 20) had significant LV wall thinning, chamber enlargement, and depressed ejection fraction (32.6% vs 61.8%, p < 0.0001). Afterward, the LV was explanted and pressurized ex vivo, and the multiaxial lenticular stress-strain relationship was tracked. While LV tissue modulus for P1 MI and sham mice were similar (341.9 kPa vs 363.4 kPa, p = 0.6140), the modulus for P7 MI mice was significantly greater than that for P7 shams (691.6 kPa vs 429.2 kPa, p = 0.0194). We conclude that, in neonatal mice, regenerated LV muscle has similar biomechanical properties as native LV myocardium.


Assuntos
Ventrículos do Coração/fisiopatologia , Coração/fisiologia , Infarto do Miocárdio/patologia , Miocárdio/patologia , Regeneração , Animais , Animais Recém-Nascidos , Fenômenos Biomecânicos , Proliferação de Células , Colágeno/química , Ecocardiografia , Feminino , Camundongos , Camundongos Endogâmicos C57BL , Miócitos Cardíacos/citologia , Estresse Mecânico , Remodelação Ventricular
13.
Med Eng Phys ; 77: 10-18, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32008935

RESUMO

Mitral regurgitation (MR) due to annular dilation occurs in a variety of mitral valve diseases and is observed in many patients with heart failure due to mitral regurgitation. To understand the biomechanics of MR and ultimately design an optimized annuloplasty ring, a representative disease model with asymmetric dilation of the mitral annulus is needed. This work shows the design and implementation of a 3D-printed valve dilation device to preferentially dilate the posterior mitral valve annulus. Porcine mitral valves (n = 3) were sewn into the device and mounted within a left heart simulator that generates physiologic pressures and flows through the valves, while chordal forces were measured. The valves were incrementally dilated, inducing MR, while hemodynamic and force data were collected. Flow analysis demonstrated that MR increased linearly with respect to percent annular dilation when dilation was greater than a 25.6% dilation threshold (p < 0.01). Pre-threshold, dilation did not cause significant increases in regurgitant fraction. Forces on the chordae tendineae increased as dilation increased prior to the identified threshold (p < 0.01); post-threshold, the MR resulted in highly variable forces. Ultimately, this novel dilation device can be used to more accurately model a wide range of MR disease states and their corresponding repair techniques using ex vivo experimentation. In particular, this annular dilation device provides the means to investigate the design and optimization of novel annuloplasty rings.


Assuntos
Dilatação/instrumentação , Insuficiência da Valva Mitral/terapia , Impressão Tridimensional , Animais , Desenho de Equipamento , Hemodinâmica , Insuficiência da Valva Mitral/fisiopatologia , Suínos
14.
Cells ; 9(1)2020 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-31963369

RESUMO

Newborn mice and piglets exhibit natural heart regeneration after myocardial infarction (MI). Discovering other mammals with this ability would provide evidence that neonatal cardiac regeneration after MI may be a conserved phenotype, which if activated in adults could open new options for treating ischemic cardiomyopathy in humans. Here, we hypothesized that newborn rats undergo natural heart regeneration after MI. Using a neonatal rat MI model, we performed left anterior descending coronary artery ligation or sham surgery in one-day-old rats under hypothermic circulatory arrest (n = 74). Operative survival was 97.3%. At 1 day post-surgery, rats in the MI group exhibited significantly reduced ejection fraction (EF) compared to shams (87.1% vs. 53.0%, p < 0.0001). At 3 weeks post-surgery, rats in the sham and MI groups demonstrated no difference in EF (71.1% vs. 69.2%, respectively, p = 0.2511), left ventricular wall thickness (p = 0.9458), or chamber diameter (p = 0.7801). Masson's trichome and picrosirius red staining revealed minimal collagen scar after MI. Increased numbers of cardiomyocytes positive for 5-ethynyl-2'-deoxyuridine (p = 0.0072), Ki-67 (p = 0.0340), and aurora B kinase (p = 0.0430) were observed within the peri-infarct region after MI, indicating ischemia-induced cardiomyocyte proliferation. Overall, we present a neonatal rat MI model and demonstrate that newborn rats are capable of endogenous neocardiomyogenesis after MI.


Assuntos
Infarto do Miocárdio/fisiopatologia , Regeneração , Animais , Animais Recém-Nascidos , Aurora Quinase B/metabolismo , Proliferação de Células , Cicatriz/patologia , Colágeno/metabolismo , Modelos Animais de Doenças , Eletrocardiografia , Feminino , Fibrose , Antígeno Ki-67/metabolismo , Ligadura , Masculino , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Infarto do Miocárdio/cirurgia , Miócitos Cardíacos/patologia , Ratos Wistar , Fatores de Tempo , Troponina/metabolismo
15.
Cytokine ; 127: 154974, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31978642

RESUMO

Although ischemic heart disease is the leading cause of death worldwide, mainstay treatments ultimately fail because they do not adequately address disease pathophysiology. Restoring the microvascular perfusion deficit remains a significant unmet need and may be addressed via delivery of pro-angiogenic cytokines. The therapeutic effect of cytokines can be enhanced by encapsulation within hydrogels, but current hydrogels do not offer sufficient clinical translatability due to unfavorable viscoelastic mechanical behavior which directly impacts the ability for minimally-invasive catheter delivery. In this report, we examine the therapeutic implications of dual-stage cytokine release from a novel, highly shear-thinning biocompatible catheter-deliverable hydrogel. We chose to encapsulate two protein-engineered cytokines, namely dimeric fragment of hepatocyte growth factor (HGFdf) and engineered stromal cell-derived factor 1α (ESA), which target distinct disease pathways. The controlled release of HGFdf and ESA from separate phases of the hyaluronic acid-based hydrogel allows extended and pronounced beneficial effects due to the precise timing of release. We evaluated the therapeutic efficacy of this treatment strategy in a small animal model of myocardial ischemia and observed a significant benefit in biological and functional parameters. Given the encouraging results from the small animal experiment, we translated this treatment to a large animal preclinical model and observed a reduction in scar size, indicating this strategy could serve as a potential adjunct therapy for the millions of people suffering from ischemic heart disease.


Assuntos
Hidrogéis/administração & dosagem , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/metabolismo , Miocárdio/metabolismo , Função Ventricular Esquerda/efeitos dos fármacos , Remodelação Ventricular/efeitos dos fármacos , Animais , Catéteres , Células Cultivadas , Modelos Animais de Doenças , Fator de Crescimento de Hepatócito/metabolismo , Humanos , Ácido Hialurônico/administração & dosagem , Isquemia Miocárdica/tratamento farmacológico , Isquemia Miocárdica/metabolismo , Miocárdio/patologia , Ratos
16.
J Biomech Eng ; 142(1)2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31253992

RESUMO

Few technologies exist that can provide quantitative data on forces within the mitral valve apparatus. Marker-based strain measurements can be performed, but chordal geometry and restricted optical access are limitations. Foil-based strain sensors have been described and work well, but the sensor footprint limits the number of chordae that can be measured. We instead utilized fiber Bragg grating (FBG) sensors-optical strain gauges made of 125 µm diameter silica fibers-to overcome some limitations of previous methods of measuring chordae tendineae forces. Using FBG sensors, we created a force-sensing neochord (FSN) that mimics the natural shape and movement of native chordae. FBG sensors reflect a specific wavelength of light depending on the spatial period of gratings. When force is applied, the gratings move relative to one another, shifting the wavelength of reflected light. This shift is directly proportional to force applied. The FBG sensors were housed in a protective sheath fashioned from a 0.025 in. flat coil, and attached to the chordae using polytetrafluoroethylene suture. The function of the force-sensing neochordae was validated in a three-dimensional (3D)-printed left heart simulator, which demonstrated that FBG sensors provide highly sensitive force measurements of mitral valve chordae at a temporal resolution of 1000 Hz. As ventricular pressures increased, such as in hypertension, chordae forces also increased. Overall, FBG sensors are a viable, durable, and high-fidelity sensing technology that can be effectively used to measure mitral valve chordae forces and overcome some limitations of other such technologies.


Assuntos
Cordas Tendinosas , Valva Mitral , Fibras Ópticas
17.
Eur J Cardiothorac Surg ; 57(3): 535-544, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31638697

RESUMO

OBJECTIVES: Posterior ventricular anchoring neochordal (PVAN) repair is a non-resectional technique for correcting mitral regurgitation (MR) due to posterior leaflet prolapse, utilizing a single suture anchored in the myocardium behind the leaflet. This technique has demonstrated clinical efficacy, although a theoretical limitation is stability of the anchoring suture. We hypothesize that the PVAN suture positions the leaflet for coaptation, after which forces are distributed evenly with low repair suture forces. METHODS: Porcine mitral valves were mounted in a 3-dimensional-printed heart simulator and chordal forces, haemodynamics and echocardiography were collected at baseline, after inducing MR by severing chordae, and after PVAN repair. Repair suture forces were measured with a force-sensing post positioned to mimic in vivo suture placement. Forces required to pull the myocardial suture free were also determined. RESULTS: Relative primary and secondary chordae forces on both leaflets were elevated during prolapse (P < 0.05). PVAN repair eliminated MR in all valves and normalized chordae forces to baseline levels on anterior primary (0.37 ± 0.23 to 0.22 ± 0.09 N, P < 0.05), posterior primary (0.62 ± 0.37 to 0.14 ± 0.05 N, P = 0.001), anterior secondary (1.48 ± 0.52 to 0.85 ± 0.43 N, P < 0.001) and posterior secondary chordae (1.42 ± 0.69 to 0.59 ± 0.17 N, P = 0.005). Repair suture forces were minimal, even compared to normal primary chordae forces (0.08 ± 0.04 vs 0.19 ± 0.08 N, P = 0.002), and were 90 times smaller than maximum forces tolerated by the myocardium (0.08 ± 0.04 vs 6.9 ± 1.3 N, P < 0.001). DISCUSSION: PVAN repair eliminates MR by positioning the posterior leaflet for coaptation, distributing forces throughout the valve. Given extremely low measured forces, the strength of the repair suture and the myocardium is not a limitation.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Animais , Cordas Tendinosas/diagnóstico por imagem , Cordas Tendinosas/cirurgia , Hemodinâmica , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Suínos
18.
Nat Biomed Eng ; 3(8): 611-620, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31391596

RESUMO

Post-operative adhesions form as a result of normal wound healing processes following any type of surgery. In cardiac surgery, pericardial adhesions are particularly problematic during reoperations, as surgeons must release the adhesions from the surface of the heart before the intended procedure can begin, thereby substantially lengthening operation times and introducing risks of haemorrhage and injury to the heart and lungs during sternal re-entry and cardiac dissection. Here we show that a dynamically crosslinked supramolecular polymer-nanoparticle hydrogel, with viscoelastic and flow properties that enable spraying onto tissue as well as robust tissue adherence and local retention in vivo for two weeks, reduces the formation of pericardial adhesions. In a rat model of severe pericardial adhesions, the hydrogel markedly reduced the severity of the adhesions, whereas commercial adhesion barriers (including Seprafilm and Interceed) did not. The hydrogels also reduced the severity of cardiac adhesions (relative to untreated animals) in a clinically relevant cardiopulmonary-bypass model in sheep. This viscoelastic supramolecular polymeric hydrogel represents a promising clinical solution for the prevention of post-operative pericardial adhesions.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Hidrogéis/química , Pericárdio/cirurgia , Polímeros/química , Aderências Teciduais , Animais , Celulose Oxidada , Ácido Hialurônico , Hidrogéis/uso terapêutico , Masculino , Modelos Animais , Nanopartículas , Polímeros/uso terapêutico , Ratos , Ovinos
19.
J Mech Behav Biomed Mater ; 96: 165-171, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31035067

RESUMO

Adverse remodeling of the left ventricle (LV) after myocardial infarction (MI) results in abnormal tissue biomechanics and impaired cardiac function, often leading to heart failure. We hypothesized that intramyocardial delivery of engineered stromal cell-derived factor 1α analog (ESA), our previously-developed supra-efficient pro-angiogenic chemokine, preserves biaxial LV mechanical properties after MI. Male Wistar rats (n = 45) underwent sham surgery (n = 15) or permanent left anterior descending coronary artery ligation. Rats sustaining MI were randomized for intramyocardial injections of either saline (100 µL, n = 15) or ESA (6 µg/kg, n = 15), delivered at four standardized borderzone sites. After 4 weeks, echocardiography was performed, and the hearts were explanted. Tensile testing of the anterolateral LV wall was performed using a displacement-controlled biaxial load frame, and modulus was determined after constitutive modeling. At 4 weeks post-MI, compared to saline controls, ESA-treated hearts had greater wall thickness (1.68 ±â€¯0.05 mm vs 1.42 ±â€¯0.08 mm, p = 0.008), smaller end-diastolic LV internal dimension (6.88 ±â€¯0.29 mm vs 7.69 ±â€¯0.22 mm, p = 0.044), and improved ejection fraction (62.8 ±â€¯3.0% vs 49.4 ±â€¯4.5%, p = 0.014). Histologic analysis revealed significantly reduced infarct size for ESA-treated hearts compared to saline controls (29.4 ±â€¯2.9% vs 41.6 ±â€¯3.1%, p = 0.021). Infarcted hearts treated with ESA exhibited decreased modulus compared to those treated with saline in both the circumferential (211.5 ±â€¯6.9 kPa vs 264.3 ±â€¯12.5 kPa, p = 0.001) and longitudinal axes (194.5 ±â€¯6.5 kPa vs 258.1 ±â€¯14.4 kPa, p < 0.001). In both principal directions, ESA-treated infarcted hearts possessed similar tissue compliance as sham non-infarcted hearts. Overall, intramyocardial ESA therapy improves post-MI ventricular remodeling and function, reduces infarct size, and preserves native LV biaxial mechanical properties.


Assuntos
Quimiocina CXCL12/genética , Quimiocina CXCL12/farmacologia , Coração/efeitos dos fármacos , Coração/fisiopatologia , Fenômenos Mecânicos/efeitos dos fármacos , Infarto do Miocárdio/fisiopatologia , Engenharia de Proteínas , Animais , Fenômenos Biomecânicos/efeitos dos fármacos , Masculino , Ratos , Ratos Wistar , Remodelação Ventricular/efeitos dos fármacos
20.
Ann Thorac Surg ; 108(1): 90-97, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30836099

RESUMO

BACKGROUND: Neochordoplasty is an important repair technique, but optimal anchoring position is unknown. Although typically anchored at papillary muscles, new percutaneous devices anchor the neochordae at or near the ventricular apex, which may have an effect on chordal forces and the long-term durability of the repair. METHODS: Porcine mitral valves (n = 6) were mounted in a left heart simulator that generates physiologic pressure and flow through the valves, and chordal forces were measured with Fiber Bragg Grating strain gauge sensors. Isolated mitral regurgitation was induced by cutting P2 primary chordae, and the regurgitant valve was repaired with polytetrafluoroethylene neochord with apical anchoring, followed by papillary muscle fixation for comparison. In both situations, the neochord was anchored to a customized force-sensing post positioned to mimic the relevant in vivo placement. RESULTS: Echocardiographic and hemodynamic data confirmed that the repairs restored physiologic hemodynamics. Forces on the chordae and neochord were lower for papillary fixation than for the apical fixation (p = 0.003). In addition, the maximum rate of change of force on the chordae and neochordae was higher for apical fixation than for papillary fixation (p = 0.028). CONCLUSIONS: Apical neochord anchoring results in effective repair of mitral regurgitation, albeit with somewhat higher forces on the chordae and neochord suture, as well as an increased rate of loading on the neochord compared with the papillary muscle fixation. These results may guide strategies to reduce stresses on neochordae as well as aid optimal patient selection.


Assuntos
Cordas Tendinosas/cirurgia , Insuficiência da Valva Mitral/cirurgia , Animais , Fenômenos Biomecânicos , Cordas Tendinosas/fisiologia , Ecocardiografia , Hemodinâmica , Insuficiência da Valva Mitral/fisiopatologia , Músculos Papilares/cirurgia , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...