Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Appl Mater Interfaces ; 16(1): 1638-1649, 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38110238

RESUMO

Portable and wearable electronics for biomechanical data collection have become a growing part of everyday life. As smart technology improves and integrates into our lives, some devices remain ineffective, expensive, or difficult to access. We propose a washable iron-on textile pressure sensor for biometric data acquisition. Biometric data, such as human gait, are a powerful tool for the monitoring and diagnosis of ambulance and physical activity. To demonstrate this, our washable iron-on device is embedded into a sock and compared to gold standard force plate data. Biomechanical testing showed that our embedded sensor displayed a high aptitude for gait event detection, successfully identifying over 96% of heel strike and toe-off gait events. Our device demonstrates excellent attributes for further investigations into low-cost, washable, and highly versatile iron-on textiles for specialized biometric analysis.


Assuntos
Dispositivos Eletrônicos Vestíveis , Humanos , Marcha , Têxteis , Fenômenos Mecânicos , Exercício Físico
2.
ACS Nano ; 17(19): 18775-18791, 2023 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-37650798

RESUMO

Although poly(aspartic acid) (PASP), a strong calcium chelating agent, may be potentially effective in inhibition of vascular calcification, its direct administration may lead to side effects. In this study, we employed polysuccinimide, a precursor of PASP, to prepare targeted polysuccinimide-based nanoparticles (PSI NPs) that not only acted as a prodrug but also functioned as a carrier of additional therapeutics to provide powerful synergistic vascular anticalcification effect. This paper shows that chemically modified PSI-NPs can serve as effective nanocarriers for loading of hydrophobic drugs, in addition to anticalcification and antireactive oxygen species (anti-ROS) activities. Curcumin (Cur), with high loading efficiency, was encapsulated into the NPs. The NPs were stable for 16 h in physiological conditions and then slowly dissolved/hydrolyzed to release the therapeutic PASP and the encapsulated drug. The drug release profile was found to be in good agreement with the NP dissolution profile such that complete release occurred after 48 h at physiological conditions. However, under acidic conditions, the NPs were stable, and Cur cumulative release reached only 30% after 1 week. Though highly effective in the prevention of calcium deposition, PSI NPs could not prevent the osteogenic trans-differentiation of vascular smooth muscle cells (VSMCs). The presence of Cur addressed this problem. It not only further reduced ROS level in macrophages but also prevented osteogenic differentiation of VSMCs in vitro. The NPs were examined in vivo in a rat model of vascular calcification induced by kidney failure through an adenine diet. The inclusion of Cur and PSI NPs combined the therapeutic effects of both. Cur-loaded NPs significantly reduced calcium deposition in the aorta without adversely affecting bone integrity or noticeable side effects/toxicity as examined by organ histological and serum biochemistry analyses.

3.
ACS Appl Mater Interfaces ; 15(25): 29777-29788, 2023 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-37318848

RESUMO

Electrohydrodynamic atomization (EHDA) provides unparalleled control over the size and production rate of particles from solution. However, conventional methods produce highly charged particles that are not appropriate for inhalation drug delivery. We present a self-propelled EHDA system to address this challenge, a promising one-step platform for generating and delivering charge-reduced particles. Our approach uses a sharp electrode to produce ion wind, which reduces the cumulative charge in the particles and transports them to a target in front of the nozzle. We effectively controlled the morphologies of polymer products created from poly(vinylidene fluoride) (PVDF) at various concentrations. Our technique has also been proven safe for bioapplications, as evidenced by the delivery of PVDF particles onto breast cancer cells. The combination of simultaneous particle production and charge reduction, along with its direct delivery capability, makes the self-propelled EHDA a versatile technique for drug delivery applications.


Assuntos
Sistemas de Liberação de Medicamentos , Polivinil , Tamanho da Partícula
4.
Artigo em Inglês | MEDLINE | ID: mdl-35656814

RESUMO

A highly versatile, low-cost, and robust tactile sensor capable of acquiring load measurements under static and dynamic modes employing a poly(vinylidene fluoride-co-trifluoroethylene) [P(VDF-TrFE)] micronanofiber element is presented. The sensor is comprised of three essential layers, a fibrous core P(VDF-TrFE) layer and two Ni/Cu conductive fabric electrode layers, with a total thickness of less than 300 µm. Using an in situ electrospinning process, the core fibers are deposited directly to a soft poly(dimethylsiloxane) (PDMS) fingertip. The core layer conforms to the surface and requires no additional processing, exhibiting the capability of the in situ electrospinning fabrication method to alleviate poor surface contacts and resolve issues associated with adhesion. The fabricated tactile sensor displayed a reliable and consistent measurement performance of static and instantaneous dynamic loads over a total of 30 000 test cycles. The capabilities and implications of the presented tactile sensor design for multimodal sensing in robot tactile sensing applications is further discussed and elucidated.

5.
RSC Adv ; 9(19): 10733-10738, 2019 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-35515282

RESUMO

The development of electronic skin (e-skin) and soft tactile sensing has recently attracted great interest. Here we report for the first time on a novel ionic liquid (IL) based soft pressure sensor with multi-point touch detection capability using 1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM]+[BF4]-) as a highly conductive sensing medium. The sensing mechanism is attributed to the repopulation of charge cations and anions in aqueous solution under pressure. The sensor can detect two dimensional touching positions with a sensitivity of -0.28% kPa-1. Our sensor showed good stability and temperature independence thanks to the incompressibility of IL in the range of touch pressure and the appropriate signal measurement configuration. We successfully demonstrated the sensor's capability to detect multi-point human touch with different pressure levels. Our simple design with smart structures and ease of fabrication processes enable the development of a soft and low-cost sensor with multiple-point sensing capabilities on a single chip.

6.
Sensors (Basel) ; 18(10)2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30275369

RESUMO

A flexible pressure sensor with a rudimentary, ultra-low cost, and solvent-free fabrication process is presented in this paper. The sensor has a graphite-on-paper stacked paper structure, which deforms and restores its shape when pressure is applied and released, showing an exceptionally fast response and relaxation time of ≈0.4 ms with a sensitivity of -5%/Pa. Repeatability of the sensor over 1000 cycles indicates an excellent long-term stability. The sensor demonstrated fast and reliable human touch interface, and successfully integrated into a robot gripper to detect grasping forces, showing high promise for use in robotics, human interface, and touch devices.

7.
Sensors (Basel) ; 16(8)2016 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-27509496

RESUMO

This paper presents the design and development of a low cost and reliable maximal voluntary bite force sensor which can be manufactured in-house by using an acrylic laser cutting machine. The sensor has been designed for ease of fabrication, assembly, calibration, and safe use. The sensor is capable of use within an hour of commencing production, allowing for rapid prototyping/modifications and practical implementation. The measured data shows a good linear relationship between the applied force and the electrical resistance of the sensor. The output signal has low drift, excellent repeatability, and a large measurable range of 0 to 700 N. A high signal-to-noise response to human bite forces was observed, indicating the high potential of the proposed sensor for human bite force measurement.


Assuntos
Técnicas Biossensoriais/instrumentação , Força de Mordida , Análise do Estresse Dentário/instrumentação , Desenho de Equipamento , Humanos , Fenômenos Mecânicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...