Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagn Microbiol Infect Dis ; 102(1): 115513, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34649190

RESUMO

Identification of asymptomatic patients is necessary to control the COVID-19 pandemic and testing is one of the measures to detect this population. We evaluated the clinical correlation of the DiaSorin Molecular Simplexa COVID-19 Direct (DiaSorin Molecular) and Roche Cobas 6800 SARS-CoV-2 (Roche) assays using 253 oropharyngeal (OP) swab specimens collected from asymptomatic patients. Agreement between DiaSorin Molecular and Roche was 97% (95% CI, 0.94 to 0.99), with a κ statistic of 0.90 (95% CI, 0.83 to 0.97) and a PPA of 89% (95% CI, 0.76 to 0.96) and NPA of 99% (95% CI, 0.97 to 0.99). Simple regression analysis of Ct values revealed a regression line of y = 1.065*X - 5.537 with a Pearson's r of 0.8542, indicating a good correlation between both platforms. The DiaSorin Molecular assay demonstrates clinical performance comparable to that of Roche in this population.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2 , Anticorpos Antivirais/análise , Infecções Assintomáticas , Humanos , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade
2.
Am J Clin Pathol ; 154(2): 201-207, 2020 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-32462195

RESUMO

OBJECTIVES: To evaluate the clinical performance of 3 molecular assays for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). METHODS: We used 184 nasopharyngeal swab specimens to compare Abbott ID NOW COVID-19 (Abbott ID NOW), DiaSorin Molecular Simplexa COVID-19 Direct (DiaSorin Simplexa), and Roche cobas 6800 SARS-CoV-2 (Roche cobas) assays. In a separate analysis, 3 specimens (nasopharyngeal, oropharyngeal, and nasal) were collected from 182 unique patients presenting to the emergency department with suspicion of coronavirus disease 2019 and were tested utilizing Abbott ID NOW. To further characterize each assay, relative limits of detection were evaluated utilizing positive nasopharyngeal patient samples. RESULTS: The positive percent agreement was 91% (95% confidence interval [CI], 0.76-0.97) for Abbott ID NOW and 100% (95% CI, 0.90-1.00) for DiaSorin Simplexa and Roche cobas. The negative percent agreement was 100% (95% CI, 0.98-1.00) for all 3 assays. All swab types tested with the Abbott assay produced concordant results. Polymerase chain reaction assays had approximately 10 to 100 times lower limits of detection than Abbott ID NOW. CONCLUSIONS: Based on these evaluations, a multiplatform testing approach is proposed, depending on patient population and assay sensitivity, to address testing needs during a public health emergency.


Assuntos
Betacoronavirus/isolamento & purificação , Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Pneumonia Viral/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Betacoronavirus/genética , COVID-19 , Teste para COVID-19 , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Pandemias , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , SARS-CoV-2 , Sensibilidade e Especificidade , Manejo de Espécimes/métodos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...