Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
J Thorac Dis ; 11(Suppl 6): S871-S888, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31183167

RESUMO

BACKGROUND: Mortality and morbidity after surgical repair for complex congenital heart defects and severe cardiopulmonary failure on extracorporeal membrane oxygenation (ECMO) support remain high despite significant advances in medical management and technological improvements. We report on outcomes and factors after using ECMO in our surgical pediatric population including short- and long-term survival. METHODS: A total of 45 neonatal and pediatric patients were identified who needed ECMO in our department between January 2008 and December 2016. In 41 cases (91%) a vaECMO (ECLS) was implemented, whereas 4 patients (9%) received vvECMO treatment for respiratory failure. In 33 cases vaECMO was implanted following cardiac surgery for congenital heart disease (CHD), whereas in 8 patients ECMO was utilized by means of extracorporeal cardiopulmonary resuscitation (eCPR) following refractory cardiac arrest. The primary endpoint of the present study was survival to discharge and long-term survival free from neurological impairments. Univariate and bivariate analysis was performed to address predictors for outcome. Kaplan-Meier survival analysis was used to address mid- and long-term survival. RESULTS: Median [IQR] duration of ECMO support was 3 [2, 5] days (range, 1-17 days). Median age at ECMO implantation was 128 [14, 1,813] days, median weight of patients was 5.4 [3.3, 12] kg. Totally 10 patients included in this study were diagnosed with concomitant genetic conditions. A total of 20 (44%) patients were successfully weaned off ECMO (survived >24 h after ECMO explantation), whereas 15 (33%) of them survived to discharge. Single ventricle (SV) repair was performed in 14, biventricular repair in 19 patients. Neonates (<30 days of age), female patients, patients with genetic conditions, SV repair patients, and eCPR patient cohort showed lower odds of survival on ECMO. Failed myocardial recovery (P=0.001), profound circulatory failure despite a high dose of catecholamines (P<0.001), neurological impairment pre-ECMO and post-ECMO (P=0.04 and P<0.001, respectively), and severe pulmonary failure despite high respiratory pressure settings were most common mortality reasons. CONCLUSIONS: ECMO provides efficient therapy opportunities for life-threatening conditions. Nevertheless, neonates and pediatric patients who underwent ECMO were at high risk for cerebrovascular events and poor survival. Appropriate patient selection using predictors of outcome reducing complications might improve outcomes of this patient cohort.

2.
J Thorac Dis ; 11(Suppl 6): S929-S937, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31183172

RESUMO

BACKGROUND: Idiopathic pulmonary artery hypertension (iPAH) is a relatively minor indication for lung transplantation (LTx) with comparatively poorer outcomes. Extracorporeal life support (ECLS) in various forms is increasingly being used in the management of this entity. However, the data and experience with this therapy remains limited. We evaluated the role of ECLS in the management of severe iPAH patients as a bridge to LTx as well as post LTx support. METHODS: A retrospective analysis of iPAH patients that received LTx between January 2007 and May 2014 was performed. Early- and mid-term outcomes were analyzed for this patient cohort. Also, early and mid-term outcomes after LTx were compared to the control group of patients with other diagnoses using unadjusted analysis and 1:3 propensity score matching. RESULTS: Of 321 LTx performed during the study period in our centre 15 patients had iPAH as a cause of end-stage lung disease. Four iPAH (27%) patients were bridged to LTx utilizing ECLS in the form of veno-arterial ECMO and extra-corporeal CO2 removal device, whereas 9 patients (60%) required ECLS support for primary graft dysfunction (PGD) after surgery. Patients with iPAH required more frequently on-pump LTx, both pre and post LTx ECLS, and had significantly lower pO2/FiO2 ratio at 24, 48 and 72 hours after LTx. Also iPAH patients had significantly longer ICU and hospital stay. Whereas the incidence of postoperative bronchiolitis obliterans syndrome (BOS) and rejection was comparable to the control group, overall cumulative survival with up to 6 years follow-up was significantly poorer in the iPAH group. After propensity score matching, the results in terms of postoperative outcomes remained as in the unadjusted analysis. CONCLUSIONS: ECLS is an essential tool in the armamentarium of any lung transplant program treating iPAH with a potential of bridge patients to transplantation and to overcome graft dysfunction after LTx. Despite utilization of ECLS in the management of iPAH, the outcomes in terms of primary graft failure and survival remain poor compared to patients with other diagnoses.

3.
J Thorac Dis ; 11(Suppl 6): S946-S956, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31183174

RESUMO

Nowadays high-tech medical assist device therapy is a crucial part of intensive care medicine. Especially, management of circulatory assist device systems poses an increasing challenge for intensive care medicine. So far, autonomous recommendations for monitoring of extracorporeal life support systems in the form of guidelines or position papers are lacking. The purpose of this paper was to present an orientation guide on this important topic.

4.
Artif Organs ; 42(12): 1125-1131, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30443997

RESUMO

Left ventricular assist device (LVAD) is now a routine therapy for advanced heart failure. Minimally invasive approach via thoracotomy for LVAD implantation is getting popular due to its potential advantage over the conventional sternotomy approach in terms of reduced risk at re-operation due to sternal sparing. We compared the approaches (thoracotomy and sternotomy) to determine the superiority. Minimally invasive approach involved fitting of the LVAD inflow cannula into left ventricle apex via left anterior thoracotomy and anastomosis of outflow graft to ascending aorta via right anterior thoracotomy. In the sternotomy approach, both the procedures were performed via sternotomy. Outcomes in patients after LVAD implantation were compared depending on these approaches for the surgery. Two hundred and five continuous flow LVAD implantations performed between July 2006 and June 2015 at a single center were divided based on surgical approach, that is, sternotomy (n = 180) and thoracotomy (n = 25) groups. There was no significant difference between the groups in relation to patient demographics, preoperative hemodynamic parameters, laboratory markers, or risk factors. There was no significant difference between the groups in terms of postoperative hemodynamic parameters, laboratory markers, bleeding and requirement of blood products, intensive care unit, and hospital stay or complications of LVAD surgery. There were no significant differences in terms of long-term survival (Log-Rank P = 0.953), however, thoracotomy, compared to sternotomy approach, incurred significantly less requirement of temporary right ventricular assist (4 vs. 19.4%, P = 0.041). Minimally invasive bilateral thoracotomy approach for LVAD implantation in addition to benefits of sternal sparing avoids dilatation of right ventricle and reduces chances of right ventricular failure requiring temporary right ventricular assist.


Assuntos
Coração Auxiliar , Implantação de Prótese/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/estatística & dados numéricos , Estudos Retrospectivos , Esternotomia/estatística & dados numéricos , Toracotomia/estatística & dados numéricos
5.
Exp Clin Transplant ; 16(1): 107-109, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28137205

RESUMO

Closure of the chest after lung transplant in cases of oversized grafts is often difficult. Lung volume reduction and delayed closure of the chest with Bogota bag are the only options available in such situations. Here, we propose to keep the sternum and intercostal spaces open and approximate skin over it. Once lung function improves and reperfusion-related edema recovers, the chest can be closed.


Assuntos
Transplante de Pulmão/métodos , Esternotomia , Esterno/cirurgia , Retalhos Cirúrgicos , Técnicas de Fechamento de Ferimentos , Aloenxertos , Feminino , Humanos , Transplante de Pulmão/efeitos adversos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Fatores de Tempo , Resultado do Tratamento , Cicatrização , Adulto Jovem
6.
Perfusion ; 32(7): 606-608, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28985703

RESUMO

Extracorporeal membrane oxygenation (ECMO) as a bridge to lung transplant (LTx) is not uncommon, but it is not commonplace yet. We present a case of a 45-year-old man with cystic fibrosis with recent deterioration in lung function who was initially supported with veno-venous (VV) ECMO. However, he subsequently required conversion to veno-veno-arterial (VVA) ECMO. After 21 days of support, he underwent double lung transplantation, with an uneventful postoperative course. This case shows that, in patients with end-stage respiratory failure awaiting lung transplantation, extracorporeal life support may require escalation to improve gas exchange and address circulatory requirements.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Pneumopatias/cirurgia , Pneumopatias/terapia , Transplante de Pulmão/métodos , Humanos , Masculino , Pessoa de Meia-Idade
7.
Perfusion ; 32(5): 419-421, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28090817

RESUMO

Cardiac rupture (CR) is one of the most serious and life-threatening complications of blunt chest trauma (BCT) usually associated with high mortality. Moreover, its diagnosis and treatment strategies may be extremely challenging for clinicians due to various anatomical localisations of the tear. Whereas most injuries fall under the category of right atrial ruptures, left ventricular lesions represent a rare type of this injury, with greater mortality, particularly in cases of multi-chamber injuries. However, not only cardiac chamber or great vessel ruptures may occur as a result of BCT; a growing number of reports also describe BCT-induced isolated coronary artery injuries, including ruptures. Whereas CR requires immediate surgical treatment, less invasive interventional techniques, such as stent placement and closure with fibrin glue or coils, can be the treatment of choice in selected cases of hemodynamically less relevant coronary artery ruptures. In this report, we present a rare case of a ventricular rupture following BCT, with the tear localized in the right ventricular wall and an occult connection to the left ventricle without ventricular septum injury. Also, another contemporaneous emergency in our department that had to be managed at the same time resulted in challenging the decision-making process. As such an emergency constellation is difficult to manage, this report may help clinicians in difficult situations in terms of diagnosis and choosing the right treatment strategy.


Assuntos
Traumatismos Cardíacos , Ventrículos do Coração , Traumatismos Torácicos , Ferimentos não Penetrantes , Idoso , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/cirurgia , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino , Traumatismos Torácicos/diagnóstico por imagem , Traumatismos Torácicos/cirurgia , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/cirurgia
8.
Artif Organs ; 41(6): 519-528, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27862040

RESUMO

The aim of this study was to compare patients with severe biventricular heart failure who underwent Berlin Heart Excor implantation with (cardiogenic shock [CS] status) or without the need for preoperative extracorporeal life support (ECLS) as a bridge to long-term device. A total of 40 consecutive patients with severe biventricular heart failure underwent Berlin Heart Excor implantation with (CS status, n = 20, 50%) or without (control, n = 20, 50%) the need for preoperative ECLS as a bridge to long-term device from March 2007 to May 2015 at our institution. Demographics and preoperative baseline characteristics as well as early and long-term outcomes including mortality and complication rates were retrospectively compared between the two groups. There were no statistically significant differences in terms of demographics and most preoperative clinical characteristics. The mean age in the ECLS (CS group) and control group was 43.5 ± 19.4 and 41.3 ± 16.4 (P = 0.705), whereas 20 and 25% of patients were females (P = 1.000). However, patients from the ECLS group had preoperatively higher lactate (P = 0.037), aspartate aminotransferase (P < 0.001), and alanine aminotransferase (P < 0.001) levels, all of them significantly decreased after surgery (P  = 0.004, P = 0.017, and P = 0.001, respectively) and did not show any statistical differences to the corresponding values from the control group (P = 0.597, P = 0.491, and P = 0.339, respectively). Postoperatively, patients from the control and ECLS groups had statistically similar incidences of liver failure (30 vs. 35%, P = 0.736), renal failure (45 vs. 70%, P = 0.110), need for reopening (35 vs. 60%, P = 0.113), major cerebrovascular events (35 vs. 30%, P = 0.736), sepsis (10 vs. 25%, P = 0.407), wound infection (20 vs. 30%, P = 0.716), abdominal ischemia requiring surgery (28.6 vs. 36.8%, P = 0.719), and acute respiratory distress syndrome (25 vs. 35.3%, P = 1.000). The proportion of patients who were bridged to transplantation was statistically similar between the ECLS and the control groups (40 vs. 52.6%, P = 0.429). Furthermore, there were no statistically significant differences in terms of early (Breslow [generalized Wilcoxon] P = 0.907) and long-term (log-rank [Mantel-Cox] P = 0.787) overall cumulative survival accounting for 30-day survival of 75 versus 75%, 6-month survival of 60 versus 55%, 1-year survival of 54 versus 40%, and 7-year survial of 47 versus 40% in the control and ECLS groups, respectively. ECLS in critical CS as a bridge to implantation of the Berlin Heart Excor ventricular assist device is safe and is associated with improvement in end-organ function leading to similar excellent early and long-term survival and incidences of major complications as in patients without the need for preoperative ECLS support.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Coração Auxiliar , Adulto , Berlim , Oxigenação por Membrana Extracorpórea/efeitos adversos , Feminino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco , Análise de Sobrevida , Resultado do Tratamento , Função Ventricular
9.
Med Sci Monit Basic Res ; 22: 107-114, 2016 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-27698339

RESUMO

Total arterial revascularization is the leading trend in coronary artery bypass grafting (CABG) for the treatment of coronary artery disease (CAD). Adding to its superiority to vein conduits, arteries allow for a high degree of versatility and long-term patency, while minimizing the need for reintervention. This is especially important for patients with multi-vessel coronary artery disease, as well as young patients. However, arterial revascularization has come a long way before being widely appreciated, with some yet unresolved debates, and advances that never cease to impress. In this review, we discuss the evolution of this surgical technique and its clinical success, as well as its most conspicuous limitations in light of accumulated published date from decades of experience.


Assuntos
Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Revascularização Miocárdica/métodos , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
10.
Med Sci Monit Basic Res ; 22: 75-9, 2016 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-27450399

RESUMO

Ventricular hypertrophy is an ominous escalation of hemodynamically stressful conditions such as hypertension and valve disease. The pathophysiology of hypertrophy is complex and multifactorial, as it touches on several cellular and molecular systems. Understanding the molecular background of cardiac hypertrophy is essential in order to protect the myocardium from pathological remodeling, or slow down the destined progression to heart failure and cardiomyopathy. In this review we highlight the most important molecular aspects of cardiac hypertrophic growth in light of the currently available published research data.


Assuntos
Cardiomegalia/fisiopatologia , Animais , Cardiomegalia/etiologia , Cardiomegalia/genética , Cardiomegalia/metabolismo , Humanos , Miocárdio/patologia
11.
Int J Artif Organs ; 39(3): 0, 2016 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-27184945

RESUMO

PURPOSE: Low cardiac output syndrome is associated with significant mortality. In patients with refractory low cardiac output left ventricular assist devices (VAD) are used to re-establish cardiac output and to prevent death. However, long-term LVAD implantation in these is complicated by a high rate of right heart failure and mortality. Therefore, our strategy is to implant a short-term VAD (left or biventricular) as a bridge to decission. METHODS: We retrospectively analysed data from 66 patients who received a short-term LVAD support prior to implantation of a long-term LVAD or HTx between 2003 and 2014. We performed short-term LVAD (CentriMag; Thoratec) implantation via median sternotomy with percutaneous cannulas. Patients were included regardless of perioperative status and severity of heart failure. Patients suffering postcardiotomy cardiogenic shock, receiving isolated RVAD as well as posttransplant patients were excluded from this study. RESULTS: Mean duration of support in the survivor group was 35 ± 25 days versus 25 ± 25 days in the nonsurvivor group (n.s.), range from 1 to 109 days. The overall survival on support was 40 (60%) patients. In the survivor group 12 patients could be successfully weaned from the system, 12 patients received a heart transplant and in 16 a long-term VAD was implanted. In the nonsurvivor group the rate of preoperative extracorporeal life support, the rate of postoperative renal failure and multiorgan failure was significantly higher. CONCLUSIONS: Thanks to its capacity for full ventricular support, short-term univentricular or biventricular LevotronixCentriMag VAD currently represents an ideal solution for bridge-to-decision.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Choque Cardiogênico/cirurgia , Adulto , Débito Cardíaco , Tomada de Decisão Clínica , Feminino , Insuficiência Cardíaca/mortalidade , Transplante de Coração , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Choque Cardiogênico/mortalidade , Esternotomia , Taxa de Sobrevida , Resultado do Tratamento , Adulto Jovem
12.
Perfusion ; 31(5): 436-7, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26519742

RESUMO

The left ventricular assist device (LVAD) is now a routine therapy for advanced heart failure. The thoracotomy approach for LVAD implantation, in which the left ventricle is approached through a pericardial rent, is becoming popular. We demonstrate closure of the pericardial rent with a polytetrafluoroethylene (PTFE) patch and its advantages.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Procedimentos Cirúrgicos Minimamente Invasivos , Implantação de Prótese/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Politetrafluoretileno , Toracotomia
13.
Med Sci Monit Basic Res ; 21: 183-90, 2015 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-26343363

RESUMO

The totally artificial heart (TAH) is among the most prominent medical innovations of the 21st century, especially due to the increasing population with end-stage heart failure. The progressive course of the disease, its resistance to conventional therapy, and the scarcity of hearts available for transplantation were the prime impetus for developing a TAH, especially when other options of mechanical circulatory assist devices are exhausted. In this review, we narrate the history of TAH, give an overview of its technology, and address the pros and cons of the currently available TAH models in light of published clinical experience.


Assuntos
Cardiopatias/terapia , Transplante de Coração/métodos , Transplante de Coração/tendências , Coração Artificial/tendências , Cardiopatias/cirurgia , Humanos , Desenho de Prótese
14.
Med Sci Monit Basic Res ; 21: 141-4, 2015 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-26250695

RESUMO

Left ventricular assist devices (LVAD) are an increasingly implemented therapeutic intervention for patients with end-stage heart failure. A growing body of evidence, however, has shown an elevated risk of device thrombosis, a major complication jeopardizing the patient's post-implantation survival. To date, multiple causative factors for LVAD thrombosis have been identified, such as internal shear stress, device material, infection, and inadequate anticoagulation. Understanding the mechanisms leading to LVAD thrombosis will not only enable device optimization, but also allow for better patient handling, hence improving post-implantation outcome. In this review we highlight the most commonly identified factors leading to LVAD thrombosis and discuss their mechanisms.


Assuntos
Doença das Coronárias/terapia , Coração Auxiliar , Doença das Coronárias/fisiopatologia , Trombose Coronária/fisiopatologia , Trombose Coronária/terapia , Humanos , Função Ventricular Esquerda
15.
Med Sci Monit Basic Res ; 21: 153-6, 2015 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-26174972

RESUMO

Roughly 60% of hearts offered for transplantation are rejected because of organ dysfunction. Moreover, hearts from circulatory-dead patients have long been thought to be non-amenable for transplantation, unlike other organs. However, tentative surgical attempts inspired by the knowledge obtained from preclinical research to recover those hearts have been performed, finally culminating in clinically successful transplants. In this review we sought to address the major concerns in non-heart-beating donor heart transplantation and highlight recently introduced developments to overcome them.


Assuntos
Transplante de Coração/métodos , Obtenção de Tecidos e Órgãos/métodos , Transplante de Coração/tendências , Humanos , Doadores de Tecidos , Isquemia Quente/métodos
16.
Med Sci Monit Basic Res ; 21: 76-80, 2015 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-25904211

RESUMO

Recent advances in surgical techniques and understanding of the pathophysiology of atrial fibrillation has led to the development of a less invasive thoracoscopic surgical treatment including video-assisted bilateral pulmonary vein isolation using bipolar radiofrequency ablation clamps. More recently, the same operation became possible via a totally thoracoscopic approach. In this paper we describe technical aspects of the thoracoscopic approach to surgical treatment of AF and discuss its features, benefits and limitations. Furthermore, we present a new alternative technique of conduction testing using endoscopic multi-electrode recording catheters. An alternative electrophysiological mapping strategy involves a multi-electrode recording catheter designed primarily for percutaneous endocardial electrophysiologic mapping procedure. According to our initial experience, the recordings obtained from the multi-electrode catheters positioned around the pulmonary veins are more accurate than the recordings obtained from the multifunctional ablation and pacing pen. The totally thoracoscopic surgical ablation approach is a feasible and efficient treatment strategy for atrial fibrillation. The conduction testing can be easily and rapidly performed using a multifunctional pen or multi-electrode recording catheter.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos/tendências , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/fisiopatologia , Toracoscopia/métodos , Humanos , Toracoscopia/tendências
17.
Interact Cardiovasc Thorac Surg ; 20(6): 755-60, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25796276

RESUMO

OBJECTIVES: Traditionally, patients on extracorporeal life support (ECLS) are sedated and mechanically ventilated and therefore prone to complications related to immobility and ventilation. We adopted this 'Awake ECLS' strategy for the patients with refractory cardiogenic shock (RCS) as a bridge to decision. METHODS: Sixty-eight patients with RCS were supported by ECLS (All veno-arterial) in years 2010-2014. Patients that could not survive 24 h after ECLS implantation (9 patients) were excluded from the study. Study population constituted 59 patients-'Awake' group (n = 18; maintained awake without intubation) and 'Control' group (n = 41; intubated and required mechanical ventilation). RESULTS: Nine (50%) patients were awake at implantation, with 5 of them remaining free of sedation and ventilator support through to explantation. Nine patients were ventilated at the time of implantation but subsequently extubated and remained non-intubated and ventilator free. Post-ECLS survival at 1 month was 78 and 42% while the survival to discharge was 78 and 37% in awake and control group, respectively. CONCLUSIONS: ECLS as a bridge to decision in RCS is effective in restoring adequate systemic perfusion and recovering end-organ function. ECLS can be initiated in awake patients with RCS and patients can be awakened on ECLS. The 'awake ECLS' strategy may avoid complications related to mechanical ventilation, sedation and immobilization. RCS patients supported on ECLS without severe metabolic acidosis, multiorgan failure, intra-aortic balloon pump or uncertain neurological status are more likely to be weaned from the ventilator. Patients that are awake at the time of ECLS implantation are more likely to remain awake during ECLS.


Assuntos
Circulação Extracorpórea/métodos , Cuidados para Prolongar a Vida/métodos , Choque Cardiogênico/terapia , Vigília , Adulto , Extubação , Circulação Extracorpórea/efeitos adversos , Circulação Extracorpórea/mortalidade , Feminino , Humanos , Hipnóticos e Sedativos/uso terapêutico , Imobilização , Intubação Intratraqueal , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Respiração Artificial , Estudos Retrospectivos , Fatores de Risco , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/mortalidade , Choque Cardiogênico/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Desmame do Respirador
18.
J Artif Organs ; 18(2): 166-9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25549810

RESUMO

Multiple implantations of left ventricular assist devices over a period of three years were performed in a 17-year-old gentleman with non-ischaemic dilated cardiomyopathy and congestive cardiac failure. The first device (HeartMate II) was implanted as a bridge to transplantation. However, after few months of support the patient showed signs of myocardial recovery and the device was successfully explanted. After 2 years of uneventful follow-up, the patient's condition deteriorated requiring further mechanical support. Due to the elevated risk associated with a redo full-support LVAD implantation, we decided to implant a partial support device (Synergy CircuLite). Because of recurrent pump thrombosis requiring device exchange, the final weeks to transplantation were bridged with CentriMag short-term LVAD. After successful cardiac transplantation the patient required further temporary extracorporeal membrane oxygenation support which was weaned off and explanted on the fourth postoperative day. After further uncomplicated postoperative recovery the patient was discharged and has been doing well for 1 year of follow-up.


Assuntos
Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/terapia , Coração Auxiliar , Adolescente , Oxigenação por Membrana Extracorpórea , Transplante de Coração , Humanos , Masculino , Reoperação
19.
Artif Organs ; 39(4): 336-42, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25345547

RESUMO

The purpose of this study was to evaluate the effects and outcome of continuous-flow left ventricular assist device (cf-LVAD) therapy in patients with preoperative acute hepatic failure. The study design was a retrospective review of prospectively collected data. Included were 42 patients who underwent cf-LVAD implantation (64.3% HeartMate II, 35.7% HeartWare) between July 2007 and May 2013 with preoperative hepatic failure defined as elevation of greater than or equal to two liver function parameters above twice the upper normal range. Mean patient age was 35 ± 12.5 years, comprising 23.8% females. Dilated cardiomyopathy was present in 92.9% of patients (left ventricular ejection fraction 17.3 ± 5.9%). Mean support duration was 511 ± 512 days (range: 2-1996 days). Mean preoperative laboratory parameters for blood urea nitrogen, serum creatinine, total bilirubin, and alanine aminotransferase were 9.5 ± 5.4 mg/dL, 110.3 ± 42.8 µmol/L, 51.7 ± 38.3 mmol/L, and 242.1 ± 268.6 U/L, respectively. All parameters decreased significantly 1 month postoperatively. The mean preoperative modified Model for Endstage Liver Disease excluding international normalized ratio score was 16.03 ± 5.57, which improved significantly after cf-LVAD implantation to 10.62 ± 5.66 (P < 0.001) at 7 days and 5.83 ± 4.98 (P < 0.001) at 30 days postoperatively. One-year and 5-year survival was 75.9 and 48.1%, respectively. 21.4% of the patients underwent LVAD explantation for myocardial recovery, 16.7% were successfully transplanted, and 7.1% underwent LVAD exchange for device failure over the follow-up period. Patients with preexisting acute hepatic failure are reasonable candidates for cf-LVAD implantation, with excellent rates of recovery and survival, suggesting that cf-LVAD therapy should not be denied to patients merely on grounds of "preoperative elevated liver enzymes/hepatopathy."


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Falência Hepática Aguda/complicações , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda , Adulto , Remoção de Dispositivo , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Transplante de Coração , Humanos , Estimativa de Kaplan-Meier , Falência Hepática Aguda/diagnóstico , Falência Hepática Aguda/mortalidade , Falência Hepática Aguda/fisiopatologia , Testes de Função Hepática , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Valor Preditivo dos Testes , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia , Adulto Jovem
20.
Artif Organs ; 39(2): 118-25, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24841499

RESUMO

The Synergy Micro-pump is the smallest implantable left ventricular assist device (LVAD) and provides partial flow support up to 4.25 L/min. It was shown that early intervention with this device can provide substantial benefits to patients with severe heart failure not yet sick enough for a full-support LVAD. However, as it can be inserted via small incisions with no need for sternotomy or cardiopulmonary bypass, it might be beneficial for selected high-risk patients. The aim of this study was to evaluate the efficacy of the Synergy Micro-pump in patients in INTERMACS class 1-2. From February 2012 to August 2013, 13 patients with severe heart failure were supported with the Synergy Pocket Micro-pump. Patients were divided into two groups according to INTERMACS class: the high-risk group (INTERMACS class 1-2) and the low-risk group (INTERMACS class 3-4). There were seven patients in INTERMACS class 1-2 and six in INTERMACS class 3-4. Patient demographics, perioperative characteristics, and postoperative outcomes were compared. There were no statistically significant differences in patient demographics, and mean support time was 108 ± 114 days in the high-risk group and 238 ± 198 days in the low-risk group. Also, there were no significant differences in perioperative characteristics or in the rate of postoperative adverse events. The overall survival was comparable between the two groups (one late death in each group, log-rank P = 0.608). Two patients from the high-risk group were upgraded to a full-support LVAD (P = 0.462) after 65 ± 84.9 days of mean support. One patient from the high-risk group and two patients from the low-risk group were successfully transplanted (P = 0.559). The use of the Synergy Micro-pump in INTERMACS 1-2 patients is feasible and is associated with similar postoperative outcome as in patients in INTERMACS 3-4. Carefully selected patients with severe heart failure could benefit due to the small size of the pump; however, further studies and medium-term follow-up are required.


Assuntos
Insuficiência Cardíaca/cirurgia , Transplante de Coração , Coração Auxiliar , Adulto , Ponte Cardiopulmonar , Feminino , Seguimentos , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...