Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pers Med ; 13(1)2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36675672

RESUMO

"One-Day Diagnosis" (1DD) for hepatobiliary and pancreatic (HBP) diseases is an innovative care pathway that combines, on the same day, surgical consultation, medical imaging, anesthesia, diagnosis announcement, and therapeutic support consultations. The objective was to evaluate the length of the 1DD care pathway compared to a conventional one. The prospective "1DD care pathway" arm included 330 consecutive patients (January 2017−April 2019) vs. 152 (November 2014−November 2015) in the retrospective "conventional" one. In the 1DD group, diagnosis was made on the same day in 83% of consultations vs. 68.4% (p = 0.0005). Although there was no difference in overall time to diagnosis, diagnostic and therapeutic management was faster in the 1DD group (1 day vs. 15 days, p < 0.0004). In addition, 77% of patients who benefited from 1DD were very satisfied with their treatment overall. The mean cost of the 1DD consultation was EUR 176.8 +/− 149 (range: 50−546). The median cost of the overall program was similar (EUR 584 vs. EUR 563, p = 0.67). As an organizational innovation, the 1DD for HBP pathologies is a promising care pathway that optimizes diagnostic and therapeutic management, without creating medical overconsumption or additional costs. Given patient satisfaction, this model should be generalized to optimize cancer care by adapting it to the constraints of different healthcare structures.

3.
Surg Radiol Anat ; 41(3): 339-341, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30607500

RESUMO

Aberrant splenic artery originating from the superior mesenteric artery (SMA) is extremely rare and recognition of this anomaly is important in the pre-operative planning of complex surgery such as pancreatic surgery, liver transplantation and vascular surgery. We present the case of an 80-year-old female diagnosed as septic shock due to mesenteric ischemia and obstructive pyelonephritis. Her splenic artery was originating from the SMA and the anomaly was readily appreciated on the pre-operative CT images. An explorative laparotomy associating extensive small bowel resection with endarterectomy of the proximal part of the SMA was performed. During intra-operative SMA control, we confirmed the aberrant splenic artery arising from SMA, and successfully avoid any arterial injury on the splenic artery with isolation and separated proximal and distal clamping. The anatomical vascular variation should be recognized in the pre-operative work-up of a determined surgical procedure to avoid potential intra-operative arterial injuries.


Assuntos
Artéria Mesentérica Superior/anatomia & histologia , Artéria Esplênica/anatomia & histologia , Idoso de 80 Anos ou mais , Variação Anatômica , Feminino , Humanos , Tomografia Computadorizada por Raios X
4.
Eur Radiol ; 29(4): 2107-2116, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30324392

RESUMO

OBJECTIVES: To investigate the radiation dose exposure, image quality, and diagnostic performance of enhanced 100-kVp abdominopelvic single-energy CT protocol with tin filter (TF). METHODS: Ninety-three consecutive patients referred for a single-phase enhanced abdominopelvic CT were prospectively included after informed consent. They underwent in addition to a standard protocol (SP) an acquisition with TF. Both examinations were performed on a third-generation dual-source CT system (DSCT), in single energy, using automatic tube current modulation, identical pitch, and identical level of iterative reconstruction. Radiation metrics were compared. Size-specific dose estimates (SSDE), contrast to noise ratio (CNR), and figure of merit (FOM) were calculated. Diagnostic confidence for the assessment of a predetermined list of abdominal lesions was rated by two independent readers. RESULTS: The mean dose of the TF protocol was significantly lower (CDTI 1.56 ± 0.43 mGy vs. 8.13 ± 3.32, p < 0.001; SSDE 9.94 ± 3.08 vs. 1.93 ± 0.39, p < 0.001), with an effective dose close to 1 mSv (1.14 mSv ± 0.34; p < 0.001). TF group exhibited non-significant lower liver CNR (2.76 vs. 3.03, p = 0.56) and was more dose efficient (FOM 10.6 vs. 2.49/mSv, p < 0.001) in comparison to SP. The mean diagnostic confidence for visceral, bone, and peritoneal tumors was equivalent between both groups. CONCLUSIONS: Enhanced 100-kVp abdominopelvic CT acquired after spectral shaping with tin filtration can achieve similar diagnostic performance and CNR compared to a standard CT protocol, while reducing the radiation dose by 81%. KEY POINTS: • 100-kVp spectral filtration enables enhanced abdominal CT with high-dose efficiency. • The radiation dose reaches the 1-mSv range. • Predetermined abdominopelvic lesions can be assessed without impairing on diagnostic confidence.


Assuntos
Abdome/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Tomografia Computadorizada Multidetectores/métodos , Idoso , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Estudos Prospectivos , Doses de Radiação , Exposição à Radiação , Reprodutibilidade dos Testes
5.
Ann Surg ; 266(5): 890-897, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28742709

RESUMO

OBJECTIVE: We aimed to prospectively evaluate NIR-C, VR-AR, and x-ray intraoperative cholangiography (IOC) during robotic cholecystectomy. BACKGROUND: Near-infrared cholangiography (NIR-C) provides real-time, radiation-free biliary anatomy enhancement. Three-dimensional virtual reality (VR) biliary anatomy models can be obtained via software manipulation of magnetic resonance cholangiopancreatography, enabling preoperative VR exploration, and intraoperative augmented reality (AR) navigation. METHODS: Fifty-eight patients were scheduled for cholecystectomy for gallbladder lithiasis. VR surgical planning was performed on virtual models. At anesthesia induction, indocyanine green was injected intravenously. AR navigation was obtained by overlaying the virtual model onto real-time images. Before and after Calot triangle dissection, NIR-C was obtained by turning the camera to NIR mode. Finally, an IOC was performed. The 3 modality performances were evaluated and image quality was assessed with a Likert-scale questionnaire. RESULTS: The three-dimensional VR planning enabled the identification of 12 anatomical variants in 8 patients, of which only 7 were correctly reported by the radiologists (P = 0.037). A dangerous variant identified at VR induced a "fundus first" approach. The cystic-common bile duct junction was visualized before Calot triangle dissection at VR in 100% of cases, at NIR-C in 98.15%, and in 96.15% at IOC.Mean time to obtain relevant images was shorter with NIR-C versus AR (P = 0.008) and versus IOC (P = 0.00000003). Image quality scores were lower with NIR-C versus AR (P = 0.018) and versus IOC (P < 0.0001). CONCLUSIONS: This high-tech protocol illustrates the multimodal imaging of biliary anatomy towards precision cholecystectomy. Those visualization techniques could complement to reduce the likelihood of biliary injuries (NCT01881399).


Assuntos
Colecistectomia/métodos , Colecistolitíase/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Colangiografia , Colangiopancreatografia por Ressonância Magnética , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Imagem Óptica , Cuidados Pré-Operatórios/métodos , Estudos Prospectivos , Radiografia Intervencionista , Espectroscopia de Luz Próxima ao Infravermelho , Resultado do Tratamento , Interface Usuário-Computador
6.
World J Gastroenterol ; 23(4): 730-734, 2017 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-28216981

RESUMO

We report here the case of a young man suffering from a rare germ cell tumour. The patient was a 25-year-old man who was referred to our centre for asthenia, stinging epigastric pain, and an iron deficiency anaemia. Gastroscopy revealed a circumferential vegetating lesion on the second portion of the duodenum. The lesion was indurated at the third portion of the duodenum, responsible for a tight stenosis. A computerized tomography-scan of the chest, abdomen and pelvis, and a pancreatic MRI showed a circumferential lesion with a bi-ductal dilatation (i.e., of the common bile duct and Wirsung's duct) without metastatic localisation. The patient underwent a pancreaticoduodenectomy with lymph node dissection including all cellular adipose tissues of the hepatic pedicle from the hepatic common artery and of the retroportal lamina. Histological findings were suggestive of a duodenal embryonal carcinoma with pancreatic infiltration. This is the second published case highlighting the duodenal primitive localisation of an embryonal carcinoma with pancreatic infiltration.


Assuntos
Carcinoma Embrionário/diagnóstico , Neoplasias Duodenais/diagnóstico , Duodeno/patologia , Neoplasias Embrionárias de Células Germinativas/diagnóstico , Neoplasias Pancreáticas/diagnóstico , Adulto , Anemia/complicações , Carcinoma Embrionário/patologia , Carcinoma Embrionário/cirurgia , Ducto Colédoco/cirurgia , Neoplasias Duodenais/patologia , Neoplasias Duodenais/cirurgia , Humanos , Imageamento por Ressonância Magnética , Masculino , Neoplasias Embrionárias de Células Germinativas/cirurgia , Ductos Pancreáticos/cirurgia , Neoplasias Pancreáticas/secundário , Neoplasias Pancreáticas/cirurgia , Pancreaticoduodenectomia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...