Magn Reson Med ; 57(1): 226-32, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17191244

RESUMO

Two-dimensional (2D) axial continuously-moving-table imaging has to deal with artifacts due to gradient nonlinearity and breathing motion, and has to provide the highest scan efficiency. Parallel imaging techniques (e.g., generalized autocalibrating partially parallel acquisition GRAPPA)) are used to reduce such artifacts and avoid ghosting artifacts. The latter occur in T(2)-weighted multi-spin-echo (SE) acquisitions that omit an additional excitation prior to imaging scans for presaturation purposes. Multiple images are reconstructed from subdivisions of a fully sampled k-space data set, each of which is acquired in a single SE train. These images are then averaged. GRAPPA coil weights are estimated without additional measurements. Compared to conventional image reconstruction, inconsistencies between different subsets of k-space induce less artifacts when each k-space part is reconstructed separately and the multiple images are averaged afterwards. These inconsistencies may lead to inaccurate GRAPPA coil weights using the proposed intrinsic GRAPPA calibration. It is shown that aliasing artifacts in single images are canceled out after averaging. Phantom and in vivo studies demonstrate the benefit of the proposed reconstruction scheme for free-breathing axial continuously-moving-table imaging using fast multi-SE sequences.


Assuntos
Artefatos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Humanos
2.
Magn Reson Med ; 55(2): 363-70, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16408283

RESUMO

A novel technique for axial continuously moving-table scans is described that minimizes the required extension of the scanner's field of view (FOV) along the direction of table motion (z) by applying a segmented multislice acquisition technique. Any anatomical slice is acquired by applying the same phase-encoding steps at the same spatial positions along the scanner FOV. The full k-space data set of any anatomical slice is collected while the slice moves through the scanner from one scan position to the next. Simultaneous acquisition of multiple slices is realized by shifting the acquisition trajectories of different slices in time. It is demonstrated how the image artifact behavior that relates to varying imaging properties along the distance the table traverses during the acquisition of any given anatomical slice can be optimized simultaneously for all images. Discontinuities between the images along the slice axis are avoided because all z-dependent scan properties are encoded identically for all slices. Flexible spatial acquisition patterns are proposed to enable data oversampling and overlapping slice acquisitions at reduced table speeds. A framework of equations is presented by which matched parameter combinations for sliding multislice acquisitions can be applied to both single- and multiecho sequences. The new technique is validated on phantom and in vivo measurements using a T1-weighted fast low-angle shot (FLASH) sequence as well as a T2-weighted multi-spin-echo sequence of variable echo train lengths.


Assuntos
Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Humanos , Interpretação de Imagem Assistida por Computador , Movimento (Física) , Imagens de Fantasmas
3.
Magn Reson Med ; 43(4): 577-82, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10748433

RESUMO

The article presents a discussion of the basic signal behavior of contrast-modified RARE(TSE,FSE...)-sequences which have been modified such that the echo train used for image encoding is preceded by a long echo interval in order to introduce the T(2)-contrast of conventional spin-echo sequences while maintaining the high imaging speed of TSE. Sequences aimed at breathhold abdominal imaging as well as for the detection of hemorrhages in the CNS have been implemented and optimized. The significant difference in image contrast at identical echo times compared to unmodified TSE is demonstrated for different tissues.


Assuntos
Meios de Contraste/administração & dosagem , Imagem Ecoplanar/métodos , Aumento da Imagem , Encéfalo/patologia , Humanos , Rim/patologia , Fígado/patologia , Imagens de Fantasmas , Sensibilidade e Especificidade , Baço/patologia