Resultados 1 - 20 de 48
Filtrar
1.
J Vasc Interv Radiol ; 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38914160

RESUMO

PURPOSE: To evaluate the safety and effectiveness of MRI-guided cryoablation of prostate cancer metastatic lymph nodes(LN). MATERIALS AND METHODS: Fifty-two patients with prostate cancer who underwent MRI guided lymph node (LN) ablation from September 2013 to June 2022 were retrospectively reviewed. Of these, 6 patients were excluded because adequate ablation margins (3-5mm) could not be achieved secondary to adjacent structures. The remaining 46 patients (mean age, 70±7 years) underwent 55 MRI-guided cryoablation procedures of metastatic LN (25 in pelvic side wall, 20 within pelvic region and 10 in the abdomen) with procedural intent of complete ablation. Locoregional tumor control (i.e. technical success in the target LN) was evaluated on initial follow-up PET scans at mean of 4±2 months. Pre- and post-ablation prostate specific antigen (PSA) levels were recorded. Imaging follow-up continued until a median of 27.5 months (3-108 months). RESULTS: Ninety-five percent (52/55) of treated LN demonstrated no considerable activity on PET scans at initial follow-up at 4±2 months. PSA decreased to undetectable level of <0.1ng/mL after cryoablation in 14/46 patients (30.4%) with corresponding lack of activity in 13/46 (28.2%) patients on continued PET imaging follow-up. Only 6/55 (10.9%) patients had transient adverse events which all resolved with no long term sequalae. CONCLUSIONS: MRI-guided percutaneous cryoablation of metastatic LN is a safe and technically effective technique for treating metastatic prostate cancer in LN.

2.
Radiol Case Rep ; 19(8): 3517-3521, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38881625

RESUMO

Dual-energy or spectral computed tomography (CT) information may be obtained by either sending X-ray beams of different energy spectra through the patient or by discriminating the energy of the X-rays that reach the detector. The spectral signal is then used to generate multiple results: conventional, virtual monoenergetic (MonoE), effective atomic number, electron density, and other material specific (e.g., iodine, calcium, or uric acid). This report demonstrates the potential benefits of spectral CT imaging during percutaneous tumor ablation procedures, specifically regarding visualization of inconspicuous tumors, accurate probe placement, and assessment of treatment efficacy.

3.
Phys Med Biol ; 69(11)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38688289

RESUMO

Objective. Conventional computed tomography (CT) imaging does not provide quantitative information on local thermal changes during percutaneous ablative therapy of cancerous and benign tumors, aside from few qualitative, visual cues. In this study, we have investigated changes in CT signal across a wide range of temperatures and two physical phases for two different tissue mimicking materials, each.Approach. A series of experiments were conducted using an anthropomorphic phantom filled with water-based gel and olive oil, respectively. Multiple, clinically used ablation devices were applied to locally cool or heat the phantom material and were arranged in a configuration that produced thermal changes in regions with inconsequential amounts of metal artifact. Eight fiber optic thermal sensors were positioned in the region absent of metal artifact and were used to record local temperatures throughout the experiments. A spectral CT scanner was used to periodically acquire and generate electron density weighted images. Average electron density weighted values in 1 mm3volumes of interest near the temperature sensors were computed and these data were then used to calculate thermal volumetric expansion coefficients for each material and phase.Main results. The experimentally determined expansion coefficients well-matched existing published values and variations with temperature-maximally differing by 5% of the known value. As a proof of concept, a CT-generated temperature map was produced during a heating time point of the water-based gel phantom, demonstrating the capability to map changes in electron density weighted signal to temperature.Significance. This study has demonstrated that spectral CT can be used to estimate local temperature changes for different materials and phases across temperature ranges produced by thermal ablations.


Assuntos
Técnicas de Ablação , Estudos de Viabilidade , Imagens de Fantasmas , Termometria , Tomografia Computadorizada por Raios X , Termometria/métodos , Técnicas de Ablação/métodos , Cirurgia Assistida por Computador/métodos , Temperatura , Humanos
4.
Med Phys ; 51(6): 4231-4242, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38353644

RESUMO

BACKGROUND: Computed tomography (CT) is routinely used to guide cryoablation procedures. Notably, CT-guidance provides 3D localization of cryoprobes and can be used to delineate frozen tissue during ablation. However, metal-induced artifacts from ablation probes can make accurate probe placement challenging and degrade the ice ball conspicuity, which in combination could lead to undertreatment of potentially curable lesions. PURPOSE: In this work, we propose an image-based neural network (CNN) model for metal artifact reduction for CT-guided interventional procedures. METHODS: An image domain metal artifact simulation framework was developed and validated for deep-learning-based metal artifact reduction for interventional oncology (MARIO). CT scans were acquired for 19 different cryoablation probe configurations. The probe configurations varied in the number of probes and the relative orientations. A combination of intensity thresholding and masking based on maximum intensity projections (MIPs) was used to segment both the probes only and probes + artifact in each phantom image. Each of the probe and probe + artifact images were then inserted into 19 unique patient exams, in the image domain, to simulate metal artifact appearance for CT-guided interventional oncology procedures. The resulting 361 pairs of simulated image volumes were partitioned into disjoint training and test datasets of 304 and 57 volumes, respectively. From the training partition, 116 600 image patches with a shape of 128 × 128 × 5 pixels were randomly extracted to be used for training data. The input images consisted of a superposition of the patient and probe + artifact images. The target images consisted of a superposition of the patient and probe only images. This dataset was used to optimize a U-Net type model. The trained model was then applied to 50 independent, previously unseen CT images obtained during renal cryoablations. Three board-certified radiologists with experience in CT-guided ablations performed a blinded review of the MARIO images. A total of 100 images (50 original, 50 MARIO processed) were assessed across different aspects of image quality on a 4-point likert-type item. Statistical analyses were performed using Wilcoxon signed-rank test for paired samples. RESULTS: Reader scores were significantly higher for MARIO processed images compared to the original images across all metrics (all p < 0.001). The average scores of the overall image quality, iceball conspicuity, overall metal artifact, needle tip visualization, target region confidence, and worst metal artifact, needle tip visualization, iceball conspicuity, and target region confidence improved by 34.91%, 36.29%, 39.94%, 34.17%, 35.13%, and 45.70%, respectively. CONCLUSIONS: The proposed method of image-based metal artifact simulation can be used to train a MARIO algorithm to effectively reduce probe-related metal artifacts in CT-guided cryoablation procedures.


Assuntos
Artefatos , Processamento de Imagem Assistida por Computador , Metais , Tomografia Computadorizada por Raios X , Processamento de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Humanos , Cirurgia Assistida por Computador/métodos , Aprendizado Profundo , Criocirurgia/métodos , Imagens de Fantasmas
5.
Radiographics ; 44(2): e230075, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38271257

RESUMO

Lymphatic flow and anatomy can be challenging to study, owing to variable lymphatic anatomy in patients with diverse primary or secondary lymphatic pathologic conditions and the fact that lymphatic imaging is rarely performed in healthy individuals. The primary components of the lymphatic system outside the head and neck are the peripheral, retroperitoneal, mesenteric, hepatic, and pulmonary lymphatic systems and the thoracic duct. Multiple techniques have been developed for imaging components of the lymphatic system over the past century, with trade-offs in spatial, temporal, and contrast resolution; invasiveness; exposure to ionizing radiation; and the ability to obtain information on dynamic lymphatic flow. More recently, dynamic contrast-enhanced (DCE) MR lymphangiography (MRL) has emerged as a valuable tool for imaging both lymphatic flow and anatomy in a variety of congenital and acquired primary or secondary lymphatic disorders. The authors provide a brief overview of lymphatic physiology, anatomy, and imaging techniques. Next, an overview of DCE MRL and the development of an MRL practice and workflow in a hybrid interventional MRI suite incorporating cart-based in-room US is provided, with an emphasis on multidisciplinary collaboration. The spectrum of congenital and acquired lymphatic disorders encountered early in an MRL practice is provided, with emphasis on the diversity of imaging findings and how DCE MRL can aid in diagnosis and treatment of these patients. Methods such as DCE MRL for assessing the hepatic and mesenteric lymphatic systems and emerging technologies that may further expand DCE MRL use such as three-dimensional printing are introduced. ©RSNA, 2024 Test Your Knowledge questions for this article are available in the supplemental material.


Assuntos
Doenças Linfáticas , Linfografia , Humanos , Linfografia/métodos , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Doenças Linfáticas/diagnóstico por imagem , Doenças Linfáticas/patologia , Sistema Linfático/patologia
6.
Med Phys ; 50(11): 6737-6747, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37712881

RESUMO

BACKGROUND: Prior implementations of the channelized Hotelling observer (CHO) model have succeeded in assessing the performance of X-ray angiography systems under a variety of imaging conditions. However, often times these conditions do not resemble those present in routine clinical imaging scenarios, such as having complex anthropomorphic backgrounds in conjunction with moving test objects. PURPOSE: This work builds up on prior established CHO methods and introduces a new approach to switch from the already established "multiple-sample" CHO implementation to a "single-sample" technique. The proposed implementation enables the inclusion of moving test objects upon nonuniform backgrounds by allowing only a single sample to represent the test object present condition that is to be used within the statistical test to estimate the detectability index. METHODS: To assess the proposed method, two image data sets were acquired with a clinical X-ray angiography system. The first set consisted of a uniform background in combination with static test objects while the second consisted of an anthropomorphic chest phantom in conjunction with moving test objects. The first set was used to validate the proposed approach against the multiple-sample method while the second was used to assess the feasibility of the proposed method under a variety of imaging conditions, including seven object sizes and seven detector target dose (DTD) levels. RESULTS: For the uniform background data set, considering all detectability indices greater or equal than 1, the ratio between the detectability indices of the proposed single-sample approach versus the multiple-sample method was 0.997 ± 0.056 (range 0.884-1.159). The average single-direction width of the 95% confidence intervals (CIs) of the detectability index estimates for the multiple-sample method was 0.38 ± 0.43 (range 0.03-2.20). For the single-sample approach, the average width was 2.52 ± 0.63 (range 1.11-5.44). For the anthropomorphic background image set, the results were consistent with classical quantum-limited signal-to-noise ratio (SNR) theory. The magnitude of the detectability indices varied predictably with changes in both object size and DTD, with the highest value associated with the highest dose and the largest object size. Additionally, the proposed method was able to capture differences in the imaging performance for a given test object across the field of view, which was associated with the attenuation levels provided by different features of the anthropomorphic background. CONCLUSIONS: A new single-sample variant of the CHO model to assess the performance of X-ray angiography imaging systems is proposed. The new approach is consistent with quantum-limited image quality theory and with a standard implementation of the CHO model. The proposed method enables the assessment of moving test objects in combination with complex, nonuniform image backgrounds, thereby opening the possibility to assess imaging conditions which more closely resemble those used in clinical care.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X , Humanos , Raios X , Processamento de Imagem Assistida por Computador/métodos , Variações Dependentes do Observador , Imagens de Fantasmas , Angiografia
7.
J Appl Clin Med Phys ; 24(7): e14074, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37335819

RESUMO

PURPOSE: To determine the suitability of a quality assurance (QA) program based on the American College of Radiology's (ACR) CT quality control (QC) manual to fully evaluate the unique capabilities of a clinical photon-counting-detector (PCD) CT system. METHODS: A daily QA program was established to evaluate CT number accuracy and artifacts for both standard and ultra-high-resolution (UHR) scan modes. A complete system performance evaluation was conducted in accordance with the ACR CT QC manual by scanning the CT Accreditation Phantom with routine clinical protocols and reconstructing low-energy-threshold (T3D) and virtual monoenergetic images (VMIs) between 40 and 120 keV. Spatial resolution was evaluated by computing the modulation transfer function (MTF) for the UHR mode, and multi-energy performance was evaluated by scanning a body phantom containing four iodine inserts with concentrations between 2 and 15 mg I/cc. RESULTS: The daily QA program identified instances when the detector needed recalibration or replacement. CT number accuracy was impacted by image type: CT numbers at 70 keV VMI were within the acceptable range (defined for 120 kV). Other keV VMIs and the T3D reconstruction had at least one insert with CT number outside the acceptable range. The limiting resolution was nearly 40 lp/cm based on MTF measurements, which far exceeds the 12 lp/cm maximum capability of the ACR phantom. The CT numbers in the iodine inserts were accurate on all VMIs (3.8% average percentage error), while the iodine concentrations had an average root mean squared error of 0.3 mg I/cc. CONCLUSION: Protocols and parameters must be properly selected on PCD-CT to meet current accreditation requirements with the ACR CT phantom. Use of the 70 keV VMI allowed passing all tests prescribed in the ACR CT manual. Additional evaluations such an MTF measurement and multi-energy phantom scans are also recommended to comprehensively evaluate PCD-CT scanner performance.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Fótons , Protocolos Clínicos
8.
J Vasc Interv Radiol ; 34(1): 46-53.e4, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36202337

RESUMO

PURPOSE: To investigate the effect of simultaneous use of dual applicators on the image quality of real-time magnetic resonance (MR) thermometry and to characterize the dual-applicator treatment zone pattern during MR imaging-guided microwave ablation (MWA). MATERIALS AND METHODS: MWA experiments were performed on a 1.5-T MR scanner with 2 commercial microwave systems (902-928 MHz). Phantom experiments were first performed to evaluate the effect of dual-applicator MWA on the image quality of MR. Then, porcine tissue model experiments were conducted with real-time MR thermometry using either a single applicator or dual applicators inserted 2.6, 3.6, and 4.6 cm apart. Fiberoptic thermal probes were used to measure the temperature changes at the tissue surface. RESULTS: Simultaneous use of dual applicators resulted in a decrease in the relative signal-to-noise ratio (SNR) in the MR thermometry images to 55% ± 2.9% when compared with that of a single applicator (86.2% ± 2.0%). Despite the lower SNR, the temperature and ablation zone maps were of adequate quality to allow visualization of the ablation zone(s). The extents of increase in the temperature at the tissue surface using dual applicators (19.7 °C ± 2.6 °C) and a single applicator (18.2 °C ± 3.3 °C) were not significantly different (P = .40). Treatment zones were significantly larger (P < .05) in dual-applicator ablations (29.4 ± 0.4, 39.9 ± 0.6, and 42.6 ± 0.9 cm2 with 2.6-, 3.6-, and 4.6-cm spacing, respectively) at the end of the ablation procedure than in the single-applicator MWA (18.6 ± 0.9 cm2). CONCLUSIONS: MR imaging-guided dual-applicator MWA produced larger ablation zones while allowing adequate real-time MR thermometry image quality for monitoring the evolution of the treatment zone.


Assuntos
Micro-Ondas , Termometria , Suínos , Animais , Micro-Ondas/uso terapêutico , Fígado/patologia , Termometria/métodos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética
9.
J Med Imaging (Bellingham) ; 9(3): 035001, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35721310

RESUMO

Purpose: This work aims to develop a framework to accurately and efficiently simulate metallic objects used during interventional oncology (IO) procedures and their artifacts in computed tomography (CT) images of different body regions. Approach: A metal insertion framework based on an existing lesion insertion tool was developed. Noise and beam hardening models were incorporated into the model and validated by comparing images of real and artificially inserted metallic rods of known material composition and dimensions. The framework was further validated by inserting ablation probes into a water phantom and comparing image appearance to scans of real probes at matching locations in the phantom. Finally, a comprehensive library of metallic probes used in our IO practice was generated and a graphical user interface was built to efficiently insert any number of probes at arbitrary positions in patient CT data, including projection and image domain insertions. Results: Metallic rod experiments demonstrated that noise and beam hardening were properly modeled. Phantom and patient data with virtually inserted probes demonstrated similar artifact appearance and magnitude compared with real probes. The developed user interface resulted in accurately co-registered virtual probes both with and without accompanying artifacts from projection and image domain insertions, respectively. Conclusions: The developed metal insertion framework successfully replicates metallic object and artifact appearance with projection domain insertions and provides corresponding artifact-free images with the metallic object in the identical location through image domain insertion. This framework has potential to generate robust training libraries for deep learning algorithms and facilitate image quality optimization in interventional CT.

10.
Acad Radiol ; 29 Suppl 1: S145-S154, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33160859

RESUMO

RATIONALE AND OBJECTIVES: There are limited data on pretreatment imaging features that can predict response to neoadjuvant chemotherapy (NAC). To extract volumetric pretreatment MRI radiomics features and assess corresponding associations with breast cancer molecular subtypes, pathological complete response (pCR), and residual cancer burden (RCB) in patients treated with NAC. MATERIALS AND METHODS: In this IRB-approved study, clinical and pretreatment MRI data from patients with biopsy-proven breast cancer who received NAC between September 2009 and July 2016 were retrospectively analyzed. Tumors were manually identified and semi-automatically segmented on first postcontrast images. Morphological and three-dimensional textural features were computed, including unfiltered and filtered image data, with spatial scaling factors (SSF) of 2, 4, and 6 mm. Wilcoxon rank-sum tests and area under the receiver operating characteristic curve were used for statistical analysis. RESULTS: Two hundred and fifty nine patients with unilateral breast cancer, including 73 (28.2%) HER2+, 112 (43.2%) luminal, and 74 (28.6%) triple negative breast cancers (TNBC), were included. There was a significant difference in the median volume (p = 0.008), median longest axial tumor diameter (p = 0.009), and median longest volumetric diameter (p = 0.01) among tumor subtypes. There was also a significant difference in minimum signal intensity and entropy among the tumor subtypes with SSF = 4 mm (p = 0.009 and p = 0.02 respectively) and SSF = 6 mm (p = 0.007 and p < 0.001 respectively). Additionally, sphericity (p = 0.04) in HER2+ tumors and entropy with SSF = 2, 4, 6 mm (p = 0.004, 0.02, 0.047 respectively) in luminal tumors were significantly associated with pCR. Multiple features demonstrated significant association (p < 0.05) with pCR in TNBC and with RCB in luminal tumors and TNBC, with standard deviation of intensity with SSF = 6 mm achieving the highest AUC (AUC = 0.734) for pCR in TNBC. CONCLUSION: MRI radiomics features are associated with different molecular subtypes of breast cancer, pCR, and RCB. These features may be noninvasive imaging biomarkers to identify cancer subtype and predict response to NAC.


Assuntos
Neoplasias da Mama , Neoplasias de Mama Triplo Negativas , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Terapia Neoadjuvante , Neoplasia Residual/diagnóstico por imagem , Estudos Retrospectivos , Resultado do Tratamento , Neoplasias de Mama Triplo Negativas/diagnóstico por imagem , Neoplasias de Mama Triplo Negativas/tratamento farmacológico , Neoplasias de Mama Triplo Negativas/patologia
11.
Radiographics ; 41(6): 1785-1801, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34597216

RESUMO

Clinical use of MRI for guidance during interventional procedures emerged shortly after the introduction of clinical diagnostic MRI in the late 1980s. However, early applications of interventional MRI (iMRI) were limited owing to the lack of dedicated iMRI magnets, pulse sequences, and equipment. During the 3 decades that followed, technologic advancements in iMRI magnets that balance bore access and field strength, combined with the development of rapid MRI pulse sequences, surface coils, and commercially available MR-conditional devices, led to the rapid expansion of clinical iMRI applications, particularly in the field of body iMRI. iMRI offers several advantages, including superior soft-tissue resolution, ease of multiplanar imaging, lack of ionizing radiation, and capability to re-image the same section. Disadvantages include longer examination times, lack of MR-conditional equipment, less operator familiarity, and increased cost. Nonetheless, MRI guidance is particularly advantageous when the disease is best visualized with MRI and/or when superior soft-tissue contrast is needed for treatment monitoring. Safety in the iMRI environment is paramount and requires close collaboration among interventional radiologists, MR physicists, and all other iMRI team members. The implementation of risk-limiting measures for personnel and equipment in MR zones III and IV is key. Various commercially available MR-conditional needles, wires, and biopsy and ablation devices are now available throughout the world, depending on the local regulatory status. As such, there has been tremendous growth in the clinical applications of body iMRI, including localization of difficult lesions, biopsy, sclerotherapy, and cryoablation and thermal ablation of malignant and nonmalignant soft-tissue neoplasms. Online supplemental material is available for this article. ©RSNA, 2021.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Biópsia , Previsões , Humanos , Imageamento por Ressonância Magnética , Radiologistas
12.
Med Phys ; 48(7): 3638-3653, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33656177

RESUMO

PURPOSE: Channelized Hotelling observer (CHO) models have been implemented to assess imaging performance in x-ray angiography systems. While current methods are appropriate for assessing unprocessed images of moving test objects upon uniform-exposure backgrounds, they are inadequate for assessing conditions which more appropriately mimic clinical imaging conditions including the combination of moving test objects, complex anthropomorphic backgrounds, and image processing. In support of this broad goal, the purpose of this work was to develop theory and methods to automatically select a subset of task-specific efficient Gabor channels from a task-generic Gabor channel base set. Also, previously described theory and methods to manage detectability index (d') bias due to nonrandom temporal variations in image electronic noise will be revisited herein. METHODS: Starting with a base set of 96 Gabor channels, backward elimination of channels was used to automatically identify an "efficient" channel subset which reduced the number of channels retained in the subset while maintaining the magnitude of the d' estimate. The concept of a pixelwise Hotelling observer (PHO) model was introduced and similarly implemented to assess the performance of the efficient-channel CHO model. Bias in d' estimates arising from temporally variable nonstationary noise was modeled as a bivariate probability density function for normal distributions, where one variable corresponds to the signal from the test object and the other variable corresponds to the signal from temporally variable nonstationary noise. Theory and methods were tested on uniform-exposure unprocessed angiography images with detector target dose (DTD) of 6, 18, and 120 nGy containing static disk-shaped test objects with diameter in the range of 0.5 to 4 mm. RESULTS: Considering all DTD levels and test object sizes, the proposed method reduced the number of Gabor channels in the final subset by 63-82% compared to the original 96 Gabor channel base set, while maintaining a mean relative performance ( ( d CHO ' / d PHO ' ) × 100 % ) of 95%  ±  4% with respect to the reference PHO model. Experimental results demonstrated that the bivariate approach to account for bias due to temporally variable nonstationary noise resulted in improved correlation between the CHO and PHO models as compared to a previously proposed univariate approach. CONCLUSIONS: Computationally efficient backward elimination can be used to select an efficient subset of Gabor channels from an initial channel base set without substantially compromising the magnitude of the d' estimate. Bias due to temporally variable nonstationary noise can be modeled through a bivariate approach leading to an improved unbiased estimate of d'.


Assuntos
Angiografia , Processamento de Imagem Assistida por Computador , Viés , Humanos , Variações Dependentes do Observador , Imagens de Fantasmas , Raios X
13.
J Vasc Interv Radiol ; 32(5): 721-728.e2, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33663924

RESUMO

PURPOSE: To investigate cryoneedle heating risks during magnetic resonance (MR)-guided cryoablation and potential strategies to mitigate these risks. MATERIALS AND METHODS: Ex vivo experiments were performed on a 1.5-Tesla (T) MR scanner using an MR conditional cryoablation system on porcine tissue phantoms. Cryoneedles were placed inside the tissue phantom either with or without an angiocatheter. Typical cryoneedle geometric configurations (including gas supply line) encountered in clinical procedures with low to high expected heating risks were investigated. Up to 4 fiber optic temperature sensors were attached to the cryoneedle/angiocatheter to measure the MR-induced cryoneedle heating at different locations during MR with different estimated specific absorption rates (SARs). The impact of cryoneedle heating on cryoablation treatment was studied by comparing temperature changes during 10-min freeze-thaw cycles with and without MR. RESULTS: Rapid temperature increases of >100 °C in < 2 minutes were observed during MR with a SAR of 2.1 W/kg. The temperature changes during a typical freeze-thaw cycle were also affected by cryoneedle heating when MR was used to monitor the ice-ball evolution. The observed cryoneedle heating was affected by multiple factors; including cryoneedle geometric configurations, sequence SAR, whether an angiocatheter was used, and whether the cryoneedle was connected to the rest of the cryoablation system. CONCLUSIONS: The ex vivo experiments demonstrated that MR could induce significant cryoneedle heating risks. Furthermore, MR-induced cryoneedle heating can affect temperatures in the ice-ball evolution during the freeze-thaw cycle. Several practical strategies to reduce the cryoneedle heating have been proposed.


Assuntos
Criocirurgia/instrumentação , Imagem por Ressonância Magnética Intervencionista , Agulhas , Temperatura , Animais , Catéteres , Criocirurgia/efeitos adversos , Imagem por Ressonância Magnética Intervencionista/efeitos adversos , Carne de Porco , Medição de Risco , Fatores de Risco , Sus scrofa , Fatores de Tempo
14.
Phys Med ; 71: 100-107, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32114323

RESUMO

MRI-guided microwave ablation (MWA) is a minimally invasive treatment for localized cancer. MR thermometry has been shown to be able to provide vital information for monitoring the procedure in real-time. However, MRI during active MWA can suffer from image quality degradation due to intermittent electromagnetic interference (EMI). A novel approach to correct for EMI-contaminated images is presented here to improve MR thermometry during clinical hepatic MWA. The method was applied to MR-thermometry images acquired during four MR-guided hepatic MWA treatments using a commercially available MRI-configured microwave generator system. During the treatments MR thermometry data acquisition was synchronized to respiratory cycle to minimize the impact of motion. EMI was detected and corrected using uncontaminated k-space data from nearby frames in k-space. Substantially improved temperature and thermal damage maps have been obtained and the treatment zone can be better visualized. Our ex vivo tissue sample study shows the correction introduced minimal errors to the temperature maps and thermal damage maps.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Micro-Ondas , Terapia por Radiofrequência , Termometria , Algoritmos , Artefatos , Radiação Eletromagnética , Análise de Fourier , Humanos , Reprodutibilidade dos Testes , Razão Sinal-Ruído
15.
Abdom Radiol (NY) ; 45(4): 1155-1161, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31359096

RESUMO

PURPOSE: To describe safety, efficacy, and added oncologic margin of saline displacement of the rectal wall during MRI-guided cryoablation of primary and recurrent prostate cancer. METHODS: A retrospective review was conducted for patients who underwent MRI-guided cryoablation with saline displacement of the rectal wall for treatment of primary and recurrent prostate cancer over a 2-year period. Saline displacement was used when the distance from the edge of the ablation area to the rectal wall was insufficient to provide at least a 5-mm treatment margin. Pre- and post-ablation rectal wall displacement distances as well as ablative zone margins were assessed with MRI. Saline displacement distance was measured from the rectal wall to the edge of the lesion for focal lesion ablation and from the edge of the prostate for hemi-gland ablation. Immediate and intermediate-term complications were assessed. RESULTS: Saline displacement was used in 25 patients undergoing MRI-guided cryoablation. Twenty-one patients underwent salvage cryoablation, while four patients had it as primary treatment for prostate cancer. Median pre- and post- saline displacement rectal wall displacement distances were 6.0 and 11.2 mm, respectively (P < 0.0001). Median-added oncologic margin achieved by saline displacement was 4.6 mm (range 0.6-26.5). Median follow-up was 14 months (range 5-29). There were no intra-procedural complications and 3 patients experienced minor (Clavien-Dindo grade I) complications. One rectal complication occurred in a patient undergoing salvage cryotherapy with a history of extensive pelvic surgery and radiation. CONCLUSIONS: Saline infusion at the time of MRI- guided cryoablation for prostate cancer resulted in increased distances between the target lesion and rectum. This is a useful technique in providing an added oncologic margin when treating lesions close to the rectal wall.


Assuntos
Criocirurgia/métodos , Imagem por Ressonância Magnética Intervencionista , Recidiva Local de Neoplasia/cirurgia , Neoplasias da Próstata/cirurgia , Reto , Cloreto de Sódio/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Margens de Excisão , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/patologia , Complicações Pós-Operatórias , Neoplasias da Próstata/patologia , Estudos Retrospectivos
16.
J Breast Imaging ; 1(3): 199-204, 2019 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-38424766

RESUMO

OBJECTIVE: The quality of all clinical MRI is dependent on B0 homogeneity, which is optimized during the shimming part of a prescan or preparatory phase before image acquisition. The purpose of this study was to assess shimming techniques clinically employed for breast MRI across our practice, and to determine factors that correlate with higher image quality for contrast-enhanced breast MRI at 1.5T. METHODS: One hundred consecutive female patients were retrospectively collected with Institutional Review Board approval. Shimming-related parameters, including shim-box placement and shimming gradient offsets were extracted from prior contrast-enhanced 3D fat-suppressed T1-weighted gradient echo image acquisitions. Three breast radiologists evaluated these images for fat saturation, breast density, overall image quality, and artifacts. Technologist experience was also evaluated for variability of shimming. Generalized linear mixed models were used to compare acquisition parameters between fat saturation. P < 0.05 was considered as statistical significance. RESULTS: The percentage of soft tissue inside the field of view (FOV) (ie, Tissue/FOV) in the good fat-saturation group (0.37 ± 0.06) was significantly lower (P < 0.01) than that in the poor fat-saturation group (0.39 ± 0.06). Other shimming-related parameters were found not significantly affecting the fat-saturation outcomes. Technologists with more experience tended to have less variable shimming performance than junior technologists did. CONCLUSIONS: The quality of clinical MRI and especially breast MRI is highly dependent on shimming. Decreasing Tissue/FOV was associated with good image quality (good fat saturation). Optimization of shimming may require manual shimming or higher-order field-correction strategies.

17.
J Appl Clin Med Phys ; 19(4): 261-270, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29785834

RESUMO

We present the development of a two-component magnetic resonance (MR) fiducial system, that is, a fiducial marker device combined with an auto-segmentation algorithm, designed to be paired with existing ultrasound probe tracking and image fusion technology to automatically fuse MR and ultrasound (US) images. The fiducial device consisted of four ~6.4 mL cylindrical wells filled with 1 g/L copper sulfate solution. The algorithm was designed to automatically segment the device in clinical abdominal MR images. The algorithm's detection rate and repeatability were investigated through a phantom study and in human volunteers. The detection rate was 100% in all phantom and human images. The center-of-mass of the fiducial device was robustly identified with maximum variations of 2.9 mm in position and 0.9° in angular orientation. In volunteer images, average differences between algorithm-measured inter-marker spacings and actual separation distances were 0.53 ± 0.36 mm. "Proof-of-concept" automatic MR-US fusions were conducted with sets of images from both a phantom and volunteer using a commercial prototype system, which was built based on the above findings. Image fusion accuracy was measured to be within 5 mm for breath-hold scanning. These results demonstrate the capability of this approach to automatically fuse US and MR images acquired across a wide range of clinical abdominal pulse sequences.


Assuntos
Imageamento por Ressonância Magnética , Algoritmos , Marcadores Fiduciais , Humanos , Imagens de Fantasmas , Ultrassonografia
18.
Oper Neurosurg (Hagerstown) ; 15(5): E69-E72, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29444267

RESUMO

BACKGROUND AND IMPORTANCE: Laser interstitial thermal therapy (LiTT) has increasingly been used as a treatment option for medically refractory epilepsy, tumors, and radiation necrosis. The use of LiTT requires intraoperative magnetic resonance (MR) thermography. This can become an issue in patients with other implanted therapeutic devices such as pacemakers and vagal nerve stimulators due to concerns regarding increases in the specific absorption rate (SAR). This is a technical case report demonstrating a successfully and safely performed LiTT in a 1.5-T magnetic resonance imaging (MRI) in a patient with a pacemaker for mesial temporal sclerosis. CLINICAL PRESENTATION: An 83-yr-old gentleman who had an implanted cardiac pacemaker presented with medically intractable epilepsy and was confirmed to have mesial temporal sclerosis on imaging. Video electroencephalography demonstrated concordant ipsilateral seizures and semiology. He underwent LiTT for ablation of the mesial temporal lobe. This was performed with the below described protocol with a cardiology nurse monitoring the patient's cardiac condition and a physicist monitoring SAR, and MR imaging quality without any adverse events. CONCLUSION: This study reports on a protocol of cardiac and MR SAR to safely perform MR-guided LiTT in the setting of traditional pacemakers in patients who are not pacemaker dependent.


Assuntos
Terapia a Laser/efeitos adversos , Marca-Passo Artificial , Convulsões/terapia , Lobo Temporal , Idoso de 80 Anos ou mais , Eletroencefalografia , Humanos , Masculino
19.
J Med Imaging (Bellingham) ; 4(3): 031213, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28983493

RESUMO

The use of iterative reconstruction (IR) algorithms in CT generally decreases image noise and enables dose reduction. However, the amount of dose reduction possible using IR without sacrificing diagnostic performance is difficult to assess with conventional image quality metrics. Through this investigation, achievable dose reduction using a commercially available IR algorithm without loss of low contrast spatial resolution was determined with a channelized Hotelling observer (CHO) model and used to optimize a clinical abdomen/pelvis exam protocol. A phantom containing 21 low contrast disks-three different contrast levels and seven different diameters-was imaged at different dose levels. Images were created with filtered backprojection (FBP) and IR. The CHO was tasked with detecting the low contrast disks. CHO performance indicated dose could be reduced by 22% to 25% without compromising low contrast detectability (as compared to full-dose FBP images) whereas 50% or more dose reduction significantly reduced detection performance. Importantly, default settings for the scanner and protocol investigated reduced dose by upward of 75%. Subsequently, CHO-based protocol changes to the default protocol yielded images of higher quality and doses more consistent with values from a larger, dose-optimized scanner fleet. CHO assessment provided objective data to successfully optimize a clinical CT acquisition protocol.

20.
Artigo em Inglês | MEDLINE | ID: mdl-28943699

RESUMO

Fundamental to the development and application of channelized Hotelling observer (CHO) models is the selection of the region of interest (ROI) to evaluate. For assessment of medical imaging systems, reducing the ROI size can be advantageous. Smaller ROIs enable a greater concentration of interrogable objects in a single phantom image, thereby providing more information from a set of images and reducing the overall image acquisition burden. Additionally, smaller ROIs may promote better assessment of clinical patient images as different patient anatomies present different ROI constraints. To this end, we investigated the minimum ROI size that does not compromise the performance of the CHO model. In this study, we evaluated both simulated images and phantom CT images to identify the minimum ROI size that resulted in an accurate figure of merit (FOM) of the CHO's performance. More specifically, the minimum ROI size was evaluated as a function of the following: number of channels, spatial frequency and number of rotations of the Gabor filters, size and contrast of the object, and magnitude of the image noise. Results demonstrate that a minimum ROI size exists below which the CHO's performance is grossly inaccurate. The minimum ROI size is shown to increase with number of channels and be dictated by truncation of lower frequency filters. We developed a model to estimate the minimum ROI size as a parameterized function of the number of orientations and spatial frequencies of the Gabor filters, providing a guide for investigators to appropriately select parameters for model observer studies.