1.
Magn Reson Med ; 87(5): 2464-2480, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34958685

RESUMO

PURPOSE: To evaluate the safety of MRI in patients with fragmented retained leads (FRLs) through numerical simulation and phantom experiments. METHODS: Electromagnetic and thermal simulations were performed to determine the worst-case RF heating of 10 patient-derived FRL models during MRI at 1.5 T and 3 T and at imaging landmarks corresponding to head, chest, and abdomen. RF heating measurements were performed in phantoms implanted with reconstructed FRL models that produced highest heating in numerical simulations. The potential for unintended tissue stimulation was assessed through a conservative estimation of the electric field induced in the tissue due to gradient-induced voltages developed along the length of FRLs. RESULTS: In simulations under conservative approach, RF exposure at B1+ ≤ 2 µT generated cumulative equivalent minutes (CEM)43 < 40 at all imaging landmarks at both 1.5 T and 3 T, indicating no thermal damage for acquisition times (TAs) < 10 min. In experiments, the maximum temperature rise when FRLs were positioned at the location of maximum electric field exposure was measured to be 2.4°C at 3 T and 2.1°C at 1.5 T. Electric fields induced in the tissue due to gradient-induced voltages remained below the threshold for cardiac tissue stimulation in all cases. CONCLUSIONS: Simulation and experimental results indicate that patients with FRLs can be scanned safely at both 1.5 T and 3 T with most clinical pulse sequences.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Coração/diagnóstico por imagem , Calefação , Temperatura Alta , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 4986-4989, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34892327

RESUMO

Patients with cardiovascular implantable electronic devices (CIEDs) are often prevented from receiving magnetic resonance imaging (MRI) due to risks associated with radiofrequency (RF) heating of tissue around the implanted leads. Although MR-conditional CIEDs are available, the safety labeling of such devices does not extend to patients with fragmented retained leads (FRLs), where segments of the leads are left in the tissue after the original device is extracted. Unlike intact and isolated leads of CIEDs, FRLs are often bare conductive lead fragments in direct contact with the tissue. No experimental work has been reported that assess RF heating of FRL during MRI thus far. In this work, we performed phantom experiments to measure RF heating of 4 patient-derived FRL models in a gel-based ASTM-like phantom during RF exposure at 64 MHz (proton imaging at 1.5 T) and 123 MHz (proton imaging at 3 T). We found FRL models to generate negligible temperature rise in the gel (∆T<1.84 °C) during a 10-minute scan at both 1.5 T and 3 T. These results are in agreement with previous simulation studies and suggest MRI may be performed safely in patients with fragmented retained leads.


Assuntos
Calefação , Ondas de Rádio , Coração , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Ondas de Rádio/efeitos adversos