Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Heart ; 104(5): 416-422, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28970277

RESUMO

OBJECTIVE: Responders to cardiac resynchronisation therapy whose device has a defibrillator component and who do not receive a therapy in the lifetime of the first generator have a very low incidence of appropriate therapy after box change. We investigated the cost implications of using a risk stratification tool at the time of generator change resulting in these patients being reimplanted with a resynchronisation pacemaker. METHODS: A decision tree was created using previously published data which had demonstrated an annualised appropriate defibrillator therapy risk of 2.33%. Costs were calculated at National Health Service (NHS) national tariff rates (2016-2017). EQ-5D utility values were applied to device reimplantations, admissions and mortality data, which were then used to estimate quality-adjusted life-years (QALYs) over 5 years. RESULTS: At 5 years, the incremental cost of replacing a resynchronisation defibrillator device with a second resynchronisation defibrillator versus resynchronisation pacemaker was £5045 per patient. Incremental QALY gained was 0.0165 (defibrillator vs pacemaker), resulting in an incremental cost-effectiveness ratio (ICER) of £305 712 per QALYs gained. Probabilistic sensitivity analysis resulted in an ICER of £313 612 (defibrillator vs pacemaker). For reimplantation of all patients with a defibrillator rather than a pacemaker to yield an ICER of less than £30 000 per QALY gained (current NHS cut-off for approval of treatment), the annual arrhythmic event rate would need to be 9.3%. The budget impact of selective replacement was a saving of £2 133 985 per year. CONCLUSIONS: Implanting low-risk patients with a resynchronisation defibrillator with the same device at the time of generator change is not cost-effective by current NHS criteria. Further research is required to understand the impact of these findings on individual patients at the time of generator change.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/economia , Terapia de Ressincronização Cardíaca/economia , Desfibriladores Implantáveis/economia , Cardioversão Elétrica/economia , Fontes de Energia Elétrica/economia , Custos de Cuidados de Saúde , Disfunção Ventricular Esquerda/economia , Disfunção Ventricular Esquerda/terapia , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Tomada de Decisão Clínica , Análise Custo-Benefício , Técnicas de Apoio para a Decisão , Árvores de Decisões , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/economia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Fontes de Energia Elétrica/efeitos adversos , Desenho de Equipamento , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anos de Vida Ajustados por Qualidade de Vida , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
2.
Cardiovasc Intervent Radiol ; 36(2): 353-61, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23070104

RESUMO

PURPOSE: To determine whether primary stenting reduces the rate of restenosis compared with balloon angioplasty alone in the endovascular treatment of long superficial femoral artery lesions; and to assess the effect of treatment on quality of life. METHODS: A total of 150 patients with superior femoral artery occlusion or severe stenosis of 5-22 cm length from 17 UK centers were randomized to either primary stenting with the SMART stent or balloon angioplasty (i.e., percutaneous transluminal angioplasty, PTA). Bailout stent placement was permitted in case of inadequate result from PTA. The primary end point was restenosis measured by duplex ultrasound at 1 year. Quality-of-life assessments were performed by the EuroQol (EQ)-5D questionnaire. RESULTS: Mean lesion length was 123.0 mm in the stent group and 116.8 mm in the PTA group. A total of 140 (93.3 %) of 150 had total occlusions. At 12 months' follow-up, restenosis measured by Duplex ultrasound was not significantly different between the stent and PTA groups by intention-to-treat or as-treated analyses: 47.2 versus 43.5 % (p = 0.84) and 40.8 versus 46.7 % (p = 0.68), respectively. There were fewer target lesion revascularizations in patients randomized to stenting, but this did not reach statistical significance (12.5 vs. 20.8 %, p = 0.26). There was no difference in the rate of amputation. Patients in both groups reported improved quality of life. CONCLUSION: Primary stenting of long lesions in predominantly occluded superficial femoral arteries does not reduce the rate of binary restenosis compared with balloon angioplasty and bailout stenting. Both treatment strategies conferred a meaningful and sustained improvement to the quality of life of patients with severe superficial femoral artery disease.


Assuntos
Angioplastia com Balão/métodos , Arteriopatias Oclusivas/terapia , Artéria Femoral , Doenças Vasculares Periféricas/terapia , Stents , Idoso , Amputação Cirúrgica/estatística & dados numéricos , Arteriopatias Oclusivas/diagnóstico por imagem , Comorbidade , Feminino , Artéria Femoral/diagnóstico por imagem , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/prevenção & controle , Humanos , Masculino , Seleção de Pacientes , Doenças Vasculares Periféricas/diagnóstico por imagem , Qualidade de Vida , Estatísticas não Paramétricas , Ultrassonografia Doppler Dupla , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...