Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cardiovasc Revasc Med ; 37: 112-117, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34607786

RESUMO

Effective treatment strategies and medical devices continue to be needed in Japan and the United States of America (US) to mitigate the growing burden of cardiovascular disease and coronary heart disease. Unfortunately, there can be a delay in gaining cardiovascular device approval in Japan after a device has already been approved and is in use in the US. The Harmonization by Doing (HBD) program; however, can eliminate this delay and reduce the cost of completing a clinical trial in Japan. The HBD proof-of-concept study, COAST, resulted in approval of the Diamondback 360® Coronary Orbital Atherectomy System Micro Crown simultaneously in Japan and the US on the same day. Subsequently, the Diamondback 360® Coronary OAS Classic Crown also received approval in Japan. The COAST study provides further evidence that global clinical trials via HBD for medical devices are practical and advantageous.


Assuntos
Aterectomia Coronária , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Calcificação Vascular , Aterectomia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Humanos , Japão , Índice de Gravidade de Doença , Resultado do Tratamento , Estados Unidos , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia
3.
J Transl Med ; 16(1): 57, 2018 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-29523171

RESUMO

BACKGROUND: Multiple sclerosis (MS) is a progressively debilitating neurological condition in which the immune system abnormally erodes the myelin sheath insulating the nerves. Mesenchymal stem cells (MSC) have been used in the last decade to safely treat certain immune and inflammatory conditions. METHODS: A safety and feasibility study was completed on the use of umbilical cord MSC (UCMSC) as a treatment for MS. In this 1-year study, consenting subjects received seven intravenous infusions of 20 × 106 UCMSC over 7 days. Efficacy was assessed at baseline, 1 month and 1 year after treatment, including magnetic resonance imaging (MRI) scans, Kurtzke Expanded Disability Status Scale (EDSS), Scripps Neurological Rating Scale, Nine-Hole Peg Test, 25-Foot Walk Test, and RAND Short Form-36 quality of life questionnaire. RESULTS: Twenty subjects were enrolled in this study. No serious adverse events were reported. Of the mild AEs denoted as possibly related to treatment, most were headache or fatigue. Symptom improvements were most notable 1 month after treatment. Improvements were seen in EDSS scores (p < 0.03), as well as in bladder, bowel, and sexual dysfunction (p < 0.01), in non-dominant hand average scores (p < 0.01), in walk times (p < 0.02) and general perspective of a positive health change and improved quality of life. MRI scans of the brain and the cervical spinal cord showed inactive lesions in 15/18 (83.3%) subjects after 1 year. CONCLUSIONS: Treatment with UCMSC intravenous infusions for subjects with MS is safe, and potential therapeutic benefits should be further investigated. Trial registration ClinicalTrials.gov NCT02034188. Registered Jan 13, 2014. https://clinicaltrials.gov/ct2/show/NCT02034188.


Assuntos
Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais/citologia , Esclerose Múltipla/terapia , Cordão Umbilical/citologia , Adulto , Estudos de Viabilidade , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/diagnóstico por imagem , Resultado do Tratamento , Adulto Jovem
4.
J Vasc Surg ; 48(1): 1-9, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18486418

RESUMO

PURPOSE: The safety and efficacy of the Zenith (Cook Inc, Bloomington, Ind) endovascular graft was assessed based on the United States multicenter trial through 5 years of follow-up. METHODS: Between 2000 and 2003, the pivotal study enrolled patients to open surgery (control) or the Zenith endovascular graft (endovascular). A separate continued access study arm enrolled endovascular patients using the same inclusion/exclusion criteria. Both studies were designed for 2-year follow-up, and the pivotal endovascular patients had the option of extending the study follow-up through 5 years. All endovascular patients were stratified by physiologic risk into high-risk and standard-risk groups to assess overall mortality, rupture, conversion, endoleaks, secondary interventions, and sac enlargement. The entire endovascular cohort was pooled to assess device integrity, limb occlusion, component separation, and migration. The suboptimal endovascular result (SER) was established as an end point to assess late adverse outcomes. Statistical analyses included Kaplan-Meier estimations and Cox regression to assess factors contributing to sac enlargement and SER. RESULTS: The study enrolled 739 endovascular patients (352 pivotal, 387 continued access); 158 patients in the pivotal study reconsented to be followed up for 5 years. For the patients at standard and high risk at 5 years, the respective survival estimate was 83% and 61%, aneurysm-related death was 2% and 4%, and freedom from rupture was 100% and 99.6%, respectively. Cumulative risk of conversion, limb occlusion, migration >10 mm, or component separation was < or =3% at 5 years. Cumulative risk of late endoleak was 12% to 15%, representing the primary indication for secondary interventions which occurred in 20% of standard-risk patients and 25% of high-risk patients through 5 years. Sac enlargement was very rare and associated with advanced age and larger aneurysms. SER was predicted by advanced age and internal iliac artery occlusion. CONCLUSION: These middle- and long-term data support long-term durability of the Zenith endovascular graft. Risk of aneurysm-related death or rupture was exceptionally low, and complications of migration, limb occlusion, and device integrity issues were uncommon. Incidence of late endoleaks and association of endoleaks with sac growth underscore the need for long-term follow-up of patients treated with endovascular grafts, although the sequelae of such events are unknown.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular , Seguimentos , Humanos , Desenho de Prótese , Falha de Prótese , Stents , Resultado do Tratamento
5.
Am J Cardiol ; 95(1): 107-9, 2005 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-15619404

RESUMO

Using data from the ASian Paclitaxel-Eluting Stent Clinical Trial, a 3-center, randomized, placebo-controlled trial of nonpolymeric paclitaxel-coated stents with a single center, 81-patient intravascular ultrasound (IVUS) substudy, the length of a stent that was free of IVUS-detectable intimal hyperplasia measured 3.2 +/- 4.8 mm in placebo stents, 6.1 +/- 5.6 mm in low-dose stents, and 8.7 +/- 6.1 mm in high-dose stents (p = 0.0029). IVUS percent neointima volume obstruction correlated with the length of this IVUS neointima-free segment (r = 0.785, p <0.0001); angiographic late lumen loss and follow-up diameter stenosis also correlated with the IVUS neointima-free length of the stents (r = 0.670, p <0.0001 and r = 0.679, p <0.0001, respectively.


Assuntos
Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/prevenção & controle , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Sistemas de Liberação de Medicamentos , Paclitaxel/administração & dosagem , Stents , Túnica Íntima/diagnóstico por imagem , Túnica Íntima/patologia , Ultrassonografia de Intervenção , Humanos , Hiperplasia/diagnóstico por imagem , Ensaios Clínicos Controlados Aleatórios como Assunto
6.
Am J Cardiol ; 95(1): 105-7, 2005 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-15619403

RESUMO

We used data from the ASian Paclitaxel-Eluting Stent Clinical Trial (a 3-center, randomized, placebo-controlled trial of nonpolymeric paclitaxel-coated stents with a single-center intravascular ultrasound substudy) to compare angiographic indexes of drug-eluting stent efficacy with the magnitude of intimal hyperplasia (IH) assessed by intravascular ultrasound. Overall, percent IH (IH volume divided by stent volume) was larger in restenotic lesions than in nonrestenotic lesions (46 +/- 19% vs 15 +/- 13%, p <0.0001); angiographic late loss and follow-up diameter stenoses correlated strongly with percent IH.


Assuntos
Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Sistemas de Liberação de Medicamentos , Paclitaxel/administração & dosagem , Stents , Túnica Íntima/diagnóstico por imagem , Túnica Íntima/patologia , Ultrassonografia de Intervenção , Reestenose Coronária/prevenção & controle , Humanos , Hiperplasia/diagnóstico por imagem , Ensaios Clínicos Controlados Aleatórios como Assunto
7.
Am J Cardiol ; 94(2): 196-8, 2004 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-15246900

RESUMO

To determine the relation of intimal hyperplasia thickness to stent size in nonpolymeric paclitaxel-coated stents, intravascular ultrasound was performed after stent implantation and at 6 months. Similar to bare metal stents, this study demonstrated that intimal hyperplasia thickness is independent of stent size. There was no deleterious effect of the increased concentration associated with using the same stent design in a smaller artery, and these results suggested that stent strut density may be a more important concept than drug concentration.


Assuntos
Antineoplásicos Fitogênicos/administração & dosagem , Paclitaxel/administração & dosagem , Stents , Túnica Íntima/patologia , Humanos , Hiperplasia , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Túnica Íntima/diagnóstico por imagem , Ultrassonografia de Intervenção
8.
Am J Cardiol ; 94(2): 199-201, 2004 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-15246901

RESUMO

The investigators examined 326 pairs of angiograms from 2 randomized dose-finding (0.2 to 3.1 microg paclitaxel/mm(2) of stent surface area) clinical trials of polymer-free paclitaxel-eluting stents in de novo lesions (the ASian Paclitaxel-Eluting stent Clinical Trial [ASPECT] and the European evaLUation of Taxol Eluting Stent [ELUTES]). A dose-dependent effect was observed: the largest dose of paclitaxel in the 2 trials resulted in a significantly larger proportion of lesions at follow-up with <10% diameter stenosis (54% vs 16%, p = 0.00012 in ASPECT; 53% vs 21%, p = 0.013 in ELUTES) and with minimal luminal diameter located outside the stent compared with control stents (62% vs 20% in ASPECT, 48% vs 18% in ELUTES; p <0.05). Also, significantly shorter lesion lengths at 6-month follow-up were observed for the doses of 0.7 to 3.1 microg/mm(2) (p <0.03) relative to their respective lengths before the procedure compared with control stents.


Assuntos
Inibidores da Angiogênese/administração & dosagem , Reestenose Coronária/prevenção & controle , Paclitaxel/administração & dosagem , Stents , Túnica Íntima/patologia , Angiografia Coronária , Relação Dose-Resposta a Droga , Humanos , Hiperplasia/prevenção & controle , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Aço Inoxidável
9.
J Vasc Surg ; 39(6): 1209-18, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15192559

RESUMO

PURPOSE: The intent of this study was to assess the safety and effectiveness of the Zenith AAA Endovascular Graft compared with conventional aneurysm repair. MATERIAL AND METHODS: The study was conducted in a prospective, multicenter, nonrandomized, concurrent control manner. Physiologically similar patients with infrarenal abdominal aortic aneurysms (AAAs) underwent either open surgery or repair with the Zenith AAA Endovascular Graft. Separate analyses of physiologically challenged patients were performed. Follow-up was conducted at hospital discharge and at 1, 6, and 12 months (endovascular repair group) or 1 and 12 months (open surgical repair group). Evaluation included computed tomography, abdominal radiography, laboratory tests, and physical examination. Mortality (AAA-related and overall), morbidity, in-hospital recovery, renal function, and secondary interventions were assessed. Patients in the endovascular repair group were evaluated for change in aneurysm size, endoleak, graft migration, conversion, rupture, and device integrity. Statistical analyses were performed with the Kaplan-Meier method, Blackwelder test, propensity score assessment, two-sample t test, Yates-corrected Pearson chi(2) test, and Fisher exact test. RESULTS: Conventional open surgery was used in 80 patients, and 200 patients underwent repair with the Zenith AAA Endovascular Graft. Technical success was accomplished in 98.8% of patients in the open repair group and 99.5% in the endovascular repair group. Patients in the endovascular repair group had fewer significant adverse events within 30 days (80% vs 57%; P <.001). All-cause mortality was similar (endovascular, 3.5%; open surgery, 3.8%). Aneurysm-related mortality was higher with conventional surgery at 12 months (3.8% vs 0.5%; P =.04). In-hospital recovery and procedural measures were better for endovascular repair in all categories (P <.001). The incidence of endoleak was 17% at 30 days, 7.4% at 12 months, and 5.4% at 24 months. Aneurysm shrinkage (>5 mm) was noted in more than two thirds of patients at 12 months and three fourths of patients at 24 months. Renal dysfunction rate did not differ between groups. Migration (>5 mm) was detected in four (2%) patients through 12 months; none was greater than 10 mm or associated with adverse events through 24 months. Three conversions were performed within 12 months, one because of aneurysm rupture. Secondary procedures were more common in the endovascular group (11% vs 2.5%; P =.03). In total, 351 patients had endografts implanted, and 6 patients were noted to have barb separations through 12-month follow-up. No stent fractures were noted. CONCLUSIONS: The Zenith AAA Endovascular Graft is safe and effective for treatment of infrarenal AAAs. The high likelihood of decrease in aneurysm size provides evidence that treatment of aneurysms with this device reverses the natural history of aneurysmal disease. The importance of long-term follow-up is underscored by the small but defined incidence of barb separation and the potential for unforeseen failure modes.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/epidemiologia , Ruptura Aórtica/epidemiologia , Ruptura Aórtica/etiologia , Biomarcadores/sangue , Creatinina/sangue , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Seguimentos , Humanos , Rim/metabolismo , Rim/fisiopatologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Fatores de Risco , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
10.
Circulation ; 108(11): 1295-8, 2003 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-12952833

RESUMO

BACKGROUND: This study used serial volumetric intravascular ultrasound (IVUS) to evaluate the effect of preinterventional arterial remodeling on in-stent intimal hyperplasia (IH) after implantation of non-polymer-encapsulated paclitaxel-coated stents. METHODS AND RESULTS: Patients were randomized to placebo or one of two doses of paclitaxel (low dose, 1.28 microg/mm2; high dose, 3.10 microg/mm2). Complete preinterventional, post-stent implantation, and follow-up IVUS were available in 18 low-dose and 21 high-dose patients. IH volumes were similar in low-dose and high-dose patients: 17.6+/-15.1 mm3 in low-dose patients and 13.1+/-13.3 mm3 in high-dose patients (P=0.3). Therefore, IVUS findings in low- and high-dose patients were combined. Preinterventional remodeling was assessed by comparing lesion site to proximal and distal reference arterial area: positive remodeling (lesion>proximal reference, n=13), intermediate remodeling (distal reference

Assuntos
Reestenose Coronária/prevenção & controle , Paclitaxel/uso terapêutico , Stents , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/patologia , Feminino , Humanos , Hiperplasia , Masculino , Pessoa de Meia-Idade , Paclitaxel/administração & dosagem , Stents/efeitos adversos , Túnica Íntima/diagnóstico por imagem , Túnica Íntima/patologia , Ultrassonografia
11.
Circulation ; 107(4): 517-20, 2003 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-12566359

RESUMO

BACKGROUND: The aim of this study was to use serial volumetric intravascular ultrasound (IVUS) to evaluate the effect of a paclitaxel coating on in-stent intimal hyperplasia (IH). METHODS AND RESULTS: Patients were randomized to placebo (bare metal stents) or 1 of 2 doses of paclitaxel (low dose: 1.28 microg/mm2; high dose: 3.10 microg/mm2). Complete post-stent implantation and follow-up IVUS were available in 81 patients, including 25 control patients and in 28 receiving a low-dose and 28 receiving a high dose. Volumetric analysis of the stented segment and of both reference segments was performed. Baseline stent measurements and both reference measurements were similar among the groups. With increasing doses, there was a stepwise reduction in IH accumulation within the stented segment (31+/-22 mm3 in control, 18+/-15 mm3 in low dose, and 13+/-14 mm3 in high dose, P<0.001). Post hoc analysis showed less IH accumulation when low- and high-dose patients were compared with control (P=0.009 and P<0.001, respectively), but not when low-dose patients were compared with high-dose patients (P=0.2). Focal late malapposition was seen in 1 high-dose patient. With increasing doses, there was no significant change in the reference segments. CONCLUSIONS: Paclitaxel-coated stents are effective in reducing in-stent neointimal tissue proliferation in humans. They are not associated with edge restenosis or significant late malapposition.


Assuntos
Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/prevenção & controle , Hiperplasia/prevenção & controle , Paclitaxel/administração & dosagem , Stents , Divisão Celular/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Relação Dose-Resposta a Droga , Implantes de Medicamento/administração & dosagem , Feminino , Seguimentos , Humanos , Hiperplasia/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Stents/efeitos adversos , Resultado do Tratamento , Túnica Íntima/diagnóstico por imagem , Túnica Íntima/efeitos dos fármacos , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...