Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Am J Infect Control ; 2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38740285

RESUMO

BACKGROUND: In December 2022, the epidemic prevention and control policy was upgraded, and China entered a different stage of epidemic control. This study aims to identify implications for better infection control and health care supply during the epidemic. METHODS: A longitudinal quantitative and qualitative study was performed based on 2 comprehensive questionnaire surveys among 497 hospital infection prevention and control practitioners (HIPCPs) before and during the epidemic peak in Tianjin, China. RESULTS: The workload (8.2 hours vs 10.14 hours, P = 0) and self-reported mental health problems (23.5% vs 61.8%, P < .05) among the HIPCPs increased significantly in the peak period. Ward reconstruction and resource coordination were the most needed jobs in hospital infection control, and rapidly increased medical waste during the epidemic needs to be considered in advance. Community support for health care personnel and their families, maintaining full PPE to reduce simultaneous infection of medical staff, and clinical training of infectious diseases for medical staff, especially doctors, in advance are the most important things we learned. CONCLUSION: Although it has been 4 years since the first outbreak of coronavirus disease 2019, more improvements should be made to prepare for the next epidemic of potential diseases.

2.
Saudi J Gastroenterol ; 28(1): 46-53, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34856726

RESUMO

BACKGROUND: Endoscopy-related infections have caused multiple outbreaks. The importance of surveillance culture is gradually recognized, but sampling techniques are not consistent in many guidelines. It is unclear whether the Flush-Brush-Flush sampling method (FBFSM) is more sensitive than the conventional flush sampling method (CFSM) and whether different sampling brushes have different effects. METHODS: The propensity score matching method was done with two matching ways, 1:1 nearest neighbor propensity score matching and full matching was used to analyze the surveillance culture data collected by FBFSM and CFSM. We fit a confounder-adjusted multiple generalized linear logistic regression model to estimate the marginal odds ratio (OR). A paired study was applied to compare the sampling effect of polyurethane foam (PU) head brush and polyamide (PA) head brush. RESULT: From 2016 to 2020, 316 reprocessed endoscope samples were collected from all 59 endoscopy centers in Tianjin. About 279 (88.3%) reprocessed endoscopes met the threshold of Chinese national standards (<20 CFU/Channel). The qualified rate of reprocessed endoscopes sampling by CFSM (91.8%) and FBFSM (81.6%) was statistically different (p < 0.05). The adjusted OR by full matching for FBFSM was 7.98 (95% confidence interval: 3.35-21.78). Forty one pairs of colonoscopes, after reprocessing from 27 centers, were tested by PA and PU brushes, and no difference was found in microbial recovery. CONCLUSION: FBFSM was confirmed to be a more sensitive sampling technique. PU and PA brushes had no significant difference in sampling effect.


Assuntos
Desinfecção , Contaminação de Equipamentos , Desinfecção/métodos , Endoscópios , Humanos , Controle de Infecções/métodos , Pontuação de Propensão
3.
Environ Res ; 202: 111763, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34329634

RESUMO

Environmental contamination caused by COVID-19 patients could be a medium of transmission. Previous reports of SARS-CoV-2 in environmental surfaces were about short-term contamination. This study investigated SARS-CoV-2 RNA existence in room-temperature and low-temperature environments long after exposure (>28 days). A department store, where a COVID-19 outbreak was occurred in January 2020 (the epicenter of 43 COVID-19 patients), and a patient's apartment were included as room-temperature environments after being blocked for 57 days and 48 days, respectively. Seven cold storages and imported frozen foods inside were included as low-temperature environments (under -18 °C). Twenty food markets with potential contamination of imported frozen foods were also included to study the consecutive contamination. Information about temperature, relative humidity, and the number of days of environmental samples since the last exposure was collected and analyzed. In sum, 11,808 swab samples were collected before disinfection, of which 35 samples were positive. Persistent contamination of SARS-CoV-2 RNA was identified in the apartment (6/19), the department store (3/50), food packages in cold storages (23/1360), environmental surfaces of cold storages (2/345), and a package in the food market (1/10,034). Two positive samples were isolated from the bathroom of the apartment (66.7 %, 2/3), and doorknobs were proved with contamination in the apartment (40 %, 2/5) and cold storage (33.3 %, 1/3). The epidemiology information and environmental contamination results of an imported frozen food related COVID-19 case (138th COVID-19 patient in Tianjin) were analyzed. Based on the Ct values, the number of copies of two target genes was calculated by standard curves and linear regressions. In conclusion, SARS-CoV-2 RNA can be detected in room-temperature environments at least 57 days after the last exposure, much longer than previous reports. Based on the results of this study and previous studies, infectious SARS-CoV-2 could exist for at least 60 days on the surface of cold-chain food packages. Doorknobs and toilets (bathrooms) were important positions in COVID-19 control. High-risk populations of cold-chain-related logistic operations, such as porters, require strict prevention and high-level personal protection.


Assuntos
COVID-19 , SARS-CoV-2 , Desinfecção , Poluição Ambiental , Humanos , RNA Viral
4.
Front Environ Sci Eng ; 15(3): 46, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33391845

RESUMO

Patients with COVID-19 have revealed a massive outbreak around the world, leading to widespread concerns in global scope. Figuring out the transmission route of COVID-19 is necessary to control further spread. We analyzed the data of 43 patients in Baodi Department Store (China) to supplement the transmission route and epidemiological characteristics of COVID-19 in a cluster outbreak. Incubation median was estimated to endure 5.95 days (2-13 days). Almost 76.3% of patients sought medical attention immediately uponillness onset. The median period ofillness onsetto hospitalization and confirmation were 3.96 days (0-14) and 5.58 days (1-21), respectively. Patients with different cluster case could demonstrate unique epidemiological characteristics due to the particularity of outbreak sites. SRAS-CoV-2 can be released into the surrounding air through patient's respiratory tract activities, and can exist for a long time for long-distance transportation. SRAS-CoV-2 RNA can be detected in aerosol in different sites, including isolation ward, general ward, outdoor, toilet, hallway, and crowded public area. Environmental factors influencing were analyzed and indicated that the SARS-CoV-2 transportation in aerosol was dependent on temperature, air humidity, ventilation rate and inactivating chemicals (ozone) content. As for the infection route of case numbers 2 to 6, 10, 13, 16, 17, 18, 20 and 23, we believe that aerosol transmission played a significant role in analyzing their exposure history and environmental conditions in Baodi Department Store. Aerosol transmission could occur in some cluster cases when the environmental factors are suitable, and it is an indispensable route of COVID-19 spread.

5.
J Thorac Dis ; 12(10): 5739-5755, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33209406

RESUMO

BACKGROUND: Since the outbreak of novel coronavirus disease (COVID-19) in Wuhan, China at the beginning of December 2019, there have been over 11,200,000 confirmed cases in the world as of the 3rd July 2020, affecting over 213 countries and regions with nearly 530,000 deaths. The pandemic has been sweeping all continents, North America, Latin America, Europe, Middle East and South Asia among others at an alarming rapidity. Here, we provide an estimate of the scale of the pandemic spread under different scenarios of variation in key influencing parameters with a hybrid model. METHODS: We developed a new hybrid model of infectious disease transmission based on Cellular Automata (CA)-configured SEIR to analyse the COVID-19 outbreak and estimate its transmission pattern. A probabilistic contamination network is embedded in the pandemic transmission model to capture the randomness feature of person-to-person spread of the novel virus. We used the improved SEIR model to quantify the population contact state with isolation measures under different continuous time series contact probability via CA. We adjusted the modelling parameters to verify the model performance in accordance to the data from the reports published by the Chinese Center for Disease Control and Prevention. We simulated several scenarios by varying such key parameters as number of isolation rate, average contact times of the population, number of infected people before taking prevention and control measures, medical level and number of imported cases. RESULTS: In the baseline model, we identified that the isolation control as the most influencing factor that had the largest impact on decreasing the speed of the reproductive number, accelerating the arrival of the "inflection point" of pandemic prevention and control, and the death rate reduction. We estimated that the probability of people contacts and the number of the onset infected cases before prevention measures also had significant effect on the infection rate reduction with appropriate prevention measures adoption, which partly reflects the impact of timely measure on the severity of the outbreak. We found that imported cases will risk the domestic prevention. CONCLUSIONS: Our modelling results clearly indicate that early-stage preventive measures are the most effective way to contain the pandemic spread and a strong interventionist approach needs to be adopted by policymakers vis-à-vis of the highly contagious nature of the COVID-19. Human resources, intensified isolation and confinement as well as special hospital buildings should be prioritised in countries with large number of infections to constrain the global transmission of the virulent infection. To do so, internationally coordinated actions require to be taken to replicate good practices to less infected countries and regions immediately.

6.
Environ Sci Pollut Res Int ; 27(29): 37022-37035, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32577970

RESUMO

This study is aimed at defining the relationship between a set of environmental factors and childhood HFMD and then at estimating the related effect. The 16 environmental factors included meteorological, air pollution, and sunspot. A traditional TSR modified by using susceptible-infectious-recovery models and distribution lag nonlinear model was applied to estimate the short-term effects of daily environmental factors on children HFMD occurrence in 2014-2018 with adjustment of potential confounding factors. A total of 70,027 children aged 0-15 years with HFMD were enrolled. No significant effect was observed for daily sunspot numbers and average visibility. We found positive effects of the ambient average temperature, with an approximately m-shaped curve of the overall cumulative relationship, peaking at 25.6 °C with a relative risk (RR) of 1.45 (95% confidence intervals 1.21-1.73). The largest RR value of hot effect was achieved on the current day and then decreased by 2 days (total group, male group, and scatter group) or 1 day (female group and nursery group), and the effect lasted about 6 to 8 days from the lag 4 or lag 6 day. A greater association of temperature with HFMD for the female group and the scattered group was observed. This study suggests that ambient average temperature might be a risk factor for children HFMD in Tianjin. Further studies are warranted to confirm these findings.


Assuntos
Poluição do Ar , Doença de Mão, Pé e Boca , Adolescente , Criança , Pré-Escolar , China , Feminino , Humanos , Incidência , Lactente , Recém-Nascido , Masculino , Conceitos Meteorológicos , Atividade Solar , Temperatura
7.
Am J Infect Control ; 48(1): 19-25, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31400884

RESUMO

BACKGROUND: Various guidelines recommend several sampling techniques to verify endoscope reprocessing, but a comparative study of the efficiency for recovering microorganisms was rare. Our goal was to compare different sampling techniques for the postreprocessing endoscope to assess residual bacterial contamination and analysis of the critical factors affecting the endoscope reprocessing failure. METHODS: From 2016 to 2018, 3 techniques, the conventional flushing sampling method, flush-brush-flush sampling method (FBFSM), and pump-assisted sampling method (PASM), were compared covering all 59 endoscope units in Tianjin, China. RESULTS: A total of 237 (84.64%) flushing channel samples and 110 (61.11%) final rinse water samples met the Chinese national standard. The univariate analysis showed that the qualified rates of endoscope reprocessing sampled by PASM (65.52%) and FBFSM (75%) were significantly lower than those of the conventional flushing sampling method (91.38%). Five other factors, including the final rinse water, dry, and hospital level, were potential factors besides sample technique. The multivariate logistic analysis indicated only 2 factors (sampling technique and final rinse water) remained in the model. FBFSM, PASM, and the purified water were significantly associated with the odds of endoscope reprocessing failure, with the odds ratio (95% confidence interval) of which were 4.206 (1.757-10.067), 5.326 (2.463-11.645), and 0.309 (0.137-0.695), respectively. CONCLUSIONS: The problem of residual microorganisms of the postreprocessing endoscope was severe. Sampling technique and final rinse water were critical for endoscope reprocessing verification.


Assuntos
Desinfecção/métodos , Endoscópios Gastrointestinais/microbiologia , Contaminação de Equipamentos/prevenção & controle , Controle de Infecções/métodos , Água/normas , China , Infecção Hospitalar/prevenção & controle , Desinfecção/normas , Reutilização de Equipamento/normas , Humanos , Controle de Infecções/normas , Modelos Logísticos , Microbiologia da Água/normas
8.
Int Dent J ; 69(3): 192-199, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30565215

RESUMO

BACKGROUND: The contaminated output water from dental unit waterlines (DUWLs) is a potential risk to both patients and dental personnel who are frequently exposed to this water or aerosols. AIM: The purpose was to evaluate the contamination level and prevalence of bacteria in the output water of DUWLs, and to identify key factors to provide technical support for formulating relevant policies. METHODS: We developed a special sampling connector designed for collecting dental handpiece output water and a measurement device to assess retraction of a dental chair unit (DCU). Output water from dental handpieces and air/water syringes were collected as representative of DUWLs. Water samples were tested with reference to China's national standard. FINDINGS: From 2012 to 2017, 318 DCUs were randomly selected from 64 hospitals in Tianjin, China. Of these DCUs, 78.93% had no disinfection to prevent DUWL contamination. Three-hundred and forty-three (56.14%) samples complied with the guidelines on DUWL output water. The highest concentration of bacteria was 1.8 × 106  colony-forming units (CFUs)/mL. The three key factors of influence were as follows: daily or weekly disinfection of DUWLs; water supply source being hospital self-made purified water or purchased purified bottled water; and DCU with a valid anti-retraction valve. Potential infectious agents, including Bacillus cereus, Burkholderia cepacia and Pseudomonas aeruginosa, were isolated. CONCLUSION: There was a high rate of contamination in DUWLs. This highlights the need to develop national standards. There is a need to disinfect the DUWLs periodically and use a cleaner source of water; more attention should be paid to the efficacy of DCU anti-retraction valves.


Assuntos
Contaminação de Equipamentos , Microbiologia da Água , China , Contagem de Colônia Microbiana , Equipamentos Odontológicos , Humanos , Inquéritos e Questionários
9.
Am J Infect Control ; 46(7): e43-e48, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29778431

RESUMO

BACKGROUND: Microbiologic surveillance of flexible gastrointestinal endoscopes is recommended in several guidelines as the primary means of identifying reprocessing failures. This study aimed to evaluate the contamination level and prevalence of bacteria of post-reprocessing endoscopes and to access whether using a pump-assisted sampling method (PASM) improves the sensitivity of culture. METHODS: All 59 endoscopy units in Tianjin, China, were investigated. The PASM and the conventional flushing sampling method (CFSM) were used to compare the results of the microbial culture. Logistic regression analysis was used to identify the influencing factors. RESULTS: One hundred four (56.52%) flushing channel samples of gastrointestinal endoscopes were positive for culture, and the maximum bacterial concentration was 14,100 colony-forming units (CFU)/channel. One hundred fifty-one (82.07%) flushing samples were qualified according to the national standard of China (≤ 20 CFU/channel). The qualified rate of the samples collected by PASM was significantly lower than the qualified rate by CFSM (65.52% vs 89.68%). Using PASM (odds ratio [OR]: 4.257; 95% confidence interval [CI]: 1.870-9.690) would increase the sensitivity of culture. The use of purified water (OR: 0.288; 95% CI: 0.102-0.814) could reduce the risk of endoscope reprocessing failure. CONCLUSION: Many endoscopes fail to meet the national standard for microbial culture after reprocessing. Our results suggest that using a pump-assisted method could increase the sensitivity of the test.


Assuntos
Bactérias/isolamento & purificação , Infecção Hospitalar/prevenção & controle , Desinfecção/métodos , Endoscópios Gastrointestinais/microbiologia , Contaminação de Equipamentos/prevenção & controle , Controle de Infecções/métodos , China , Humanos
10.
Int Dent J ; 66(4): 208-14, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27000421

RESUMO

INTRODUCTION: Dental unit waterline (DUWL) output water is delivered through instruments of a dental chair unit (DCU) to irrigate and cool teeth. However, these waterlines can be heavily contaminated with bacteria. AIM: The purpose of the present study was to assess retraction and investigate the contamination level and prevalence of bacteria in DUWL output water. METHODS: Fifty-eight DCUs were randomly selected from 30 hospitals in 10 districts of Tianjin, one of the four special municipalities of China. A unique sampling connector was used in place of the dental handpiece to collect water samples. Evaluation of retraction was accomplished using a retraction measurement device designed in accordance with the International Standard ISO 7494-2:2015(E). RESULTS: A total of 263 water samples were collected, and the highest concentration of bacteria [1.8 × 10(6) colony-forming units (CFU)/mL] was found in the handpiece group. Thirty (51.72%) water samples in the handpiece group and 21 (36.21%) in the air/water syringe groups were cultured, yielding colony counts of > 500 CFU/mL. Potential infectious agents, such as Bacillus cereus, Kocuria kristinae and Pseudomonas fluorescens, were isolated from the water samples. Thirty (51.72%) DCUs failed the retraction evaluation. There was a significant, positive correlation (P < 0.05) between the concentration of bacteria in the water sample and the retracted volume. CONCLUSION: It is of paramount importance to increase compliance with the standards for controlling DUWL contamination. Routine microbial monitoring and evaluation of retraction are necessary to provide high-quality water for use in dental treatment.


Assuntos
Carga Bacteriana , Equipamentos Odontológicos/microbiologia , Contaminação de Equipamentos , China , Humanos , Controle de Infecções Dentárias/normas , Abastecimento de Água/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...