Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 94(8)2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38065184

RESUMO

An x-ray imaging scheme using spherically bent crystals was implemented on the Z-machine to image x rays emitted by the hot, dense plasma generated by a Magnetized Liner Inertial Fusion (MagLIF) target. This diagnostic relies on a spherically bent crystal to capture x-ray emission over a narrow spectral range (<15 eV), which is established by a limiting aperture placed on the Rowland circle. The spherical crystal optic provides the necessary high-throughput and large field-of-view required to produce a bright image over the entire, one-cm length of the emitting column of a plasma. The average spatial resolution was measured and determined to be 18 µm for the highest resolution configuration. With this resolution, the radial size of the stagnation column can be accurately determined and radial structures, such as bifurcations in the column, are clearly resolved. The success of the spherical-crystal imager has motivated the implementation of a new, two-crystal configuration for identifying sources of spectral line emission using a differential imaging technique.

2.
Rev Sci Instrum ; 94(5)2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37184347

RESUMO

We report on progress implementing and testing cryogenically cooled platforms for Magnetized Liner Inertial Fusion (MagLIF) experiments. Two cryogenically cooled experimental platforms were developed: an integrated platform fielded on the Z pulsed power generator that combines magnetization, laser preheat, and pulsed-power-driven fuel compression and a laser-only platform in a separate chamber that enables measurements of the laser preheat energy using shadowgraphy measurements. The laser-only experiments suggest that ∼89% ± 10% of the incident energy is coupled to the fuel in cooled targets across the energy range tested, significantly higher than previous warm experiments that achieved at most 67% coupling and in line with simulation predictions. The laser preheat configuration was applied to a cryogenically cooled integrated experiment that used a novel cryostat configuration that cooled the MagLIF liner from both ends. The integrated experiment, z3576, coupled 2.32 ± 0.25 kJ preheat energy to the fuel, the highest to-date, demonstrated excellent temperature control and nominal current delivery, and produced one of the highest pressure stagnations as determined by a Bayesian analysis of the data.

3.
Rev Sci Instrum ; 94(5)2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37129462

RESUMO

Accurate understanding of x-ray diagnostics is crucial for both interpreting high-energy-density experiments and testing simulations through quantitative comparisons. X-ray diagnostic models are complex. Past treatments of individual x-ray diagnostics on a case-by-case basis have hindered universal diagnostic understanding. Here, we derive a general formula for modeling the absolute response of non-focusing x-ray diagnostics, such as x-ray imagers, one-dimensional space-resolved spectrometers, and x-ray power diagnostics. The present model is useful for both data modeling and data processing. It naturally accounts for the x-ray crystal broadening. The new model verifies that standard approaches for a crystal response can be good approximations, but they can underestimate the total reflectivity and overestimate spectral resolving power by more than a factor of 2 in some cases near reflectivity edge features. We also find that a frequently used, simplified-crystal-response approximation for processing spectral data can introduce an absolute error of more than an order of magnitude and the relative spectral radiance error of a factor of 3. The present model is derived with straightforward geometric arguments. It is more general and is recommended for developing a unified picture and providing consistent treatment over multiple x-ray diagnostics. Such consistency is crucial for reliable multi-objective data analyses.

4.
Phys Rev Lett ; 128(25): 255001, 2022 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-35802445

RESUMO

The magneto-Rayleigh-Taylor instability (MRTI) plays an essential role in astrophysical systems and in magneto-inertial fusion, where it is known to be an important degradation mechanism of confinement and target performance. In this Letter, we show for the first time experimental evidence of mode mixing and the onset of an inverse-cascade process resulting from the nonlinear coupling of two discrete preseeded axial modes (400- and 550-µm wavelengths) on an Al liner that is magnetically imploded using the 20-MA, 100-ns rise-time Z Machine at Sandia National Laboratories. Four radiographs captured the temporal evolution of the MRTI. We introduce a novel unfold technique to analyze the experimental radiographs and compare the results to simulations and to a weakly nonlinear model. We find good quantitative agreement with simulations using the radiation magnetohydrodynamics code hydra. Spectral analysis of the MRTI time evolution obtained from the simulations shows evidence of harmonic generation, mode coupling, and the onset of an inverse-cascade process. The experiments provide a benchmark for future work on the MRTI and motivate the development of new analytical theories to better understand this instability.

5.
Phys Rev Lett ; 125(15): 155002, 2020 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-33095639

RESUMO

We present experimental results from the first systematic study of performance scaling with drive parameters for a magnetoinertial fusion concept. In magnetized liner inertial fusion experiments, the burn-averaged ion temperature doubles to 3.1 keV and the primary deuterium-deuterium neutron yield increases by more than an order of magnitude to 1.1×10^{13} (2 kJ deuterium-tritium equivalent) through a simultaneous increase in the applied magnetic field (from 10.4 to 15.9 T), laser preheat energy (from 0.46 to 1.2 kJ), and current coupling (from 16 to 20 MA). Individual parametric scans of the initial magnetic field and laser preheat energy show the expected trends, demonstrating the importance of magnetic insulation and the impact of the Nernst effect for this concept. A drive-current scan shows that present experiments operate close to the point where implosion stability is a limiting factor in performance, demonstrating the need to raise fuel pressure as drive current is increased. Simulations that capture these experimental trends indicate that another order of magnitude increase in yield on the Z facility is possible with additional increases of input parameters.

6.
Rev Sci Instrum ; 91(2): 023511, 2020 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-32113451

RESUMO

A Talbot-Lau X-ray Deflectometer (TXD) was implemented in the OMEGA EP laser facility to characterize the evolution of an irradiated foil ablation front by mapping electron densities >1022 cm-3 by means of Moiré deflectometry. The experiment used a short-pulse laser (30-100 J, 10 ps) and a foil copper target as an x-ray backlighter source. In the first experimental tests performed to benchmark the diagnostic platform, grating survival was demonstrated and x-ray backlighter laser parameters that deliver Moiré images were described. The necessary modifications to accurately probe the ablation front through TXD using the EP-TXD diagnostic platform are discussed.

7.
Phys Rev Lett ; 122(22): 225001, 2019 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-31283266

RESUMO

The creation and disruption of inertially collimated plasma flows are investigated through experiment, simulation, and analytical modeling. Supersonic plasma jets are generated by laser-irradiated plastic cones and characterized by optical interferometry measurements. Targets are magnetized with a tunable B field with strengths of up to 5 T directed along the axis of jet propagation. These experiments demonstrate a hitherto unobserved phenomenon in the laboratory, the magnetic disruption of inertially confined plasma jets. This occurs due to flux compression on axis during jet formation and can be described using a Lagrangian-cylinder model of plasma evolution implementing finite resistivity. The basic physical mechanisms driving the dynamics of these systems are described by this model and then compared with two-dimensional radiation-magnetohydrodynamic simulations. Experimental, computational, and analytical results discussed herein suggest that contemporary models underestimate the electrical conductivity necessary to drive the amount of flux compression needed to explain observations of jet disruption.

8.
Rev Sci Instrum ; 89(10): 10G114, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399807

RESUMO

The need for a time-resolved monochromatic x-ray imaging diagnostic at photon energies >15 keV has motivated the development of a Wolter optic to study x-ray sources on the Z-machine at Sandia National Laboratories. The work is performed in both the LLNL's x-ray calibration facility and SNL's micro-focus x-ray lab. Characterizations and calibrations include alignment, measurement of throughput within the field of view (FOV), the point-spread function within the FOV both in and out of focus, and bandpass in the FOV. These results are compared with ray tracing models, showing reasonable agreement.

9.
Rev Sci Instrum ; 89(10): 10G113, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399826

RESUMO

Recent breakthroughs in the fabrication of small-radii Wolter optics for astrophysics allow high energy density facilities to consider such optics as novel x-ray diagnostics at photon energies of 15-50 keV. Recently, the Lawrence Livermore National Laboratory, Sandia National Laboratories (SNL), the Smithsonian Astrophysical Observatory, and the NASA Marshall Space Flight Center jointly developed and fabricated the first custom Wolter microscope for implementation in SNL's Z machine with optimized sensitivity at 17.5 keV. To achieve spatial resolution of order 100-200 microns over a field of view of 5 × 5 × 5 mm3 with high throughput and narrow energy bandpass, the geometry of the optic and its multilayer required careful design and optimization. While the geometry mainly influences resolution and the field of view of the diagnostic, the mirror coating determines the spectral response and throughput. Here we outline the details of the design and fabrication process for the first multilayer-coated Wolter I optic for SNL's Z machine (Z Wolter), including its W/Si multilayer, and present results of raytrace simulations completed to predict and verify the performance of the optic.

10.
Rev Sci Instrum ; 89(10): 10G112, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399878

RESUMO

A facility to calibrate x-ray imaging optics was built at Lawrence Livermore National Laboratory to support high energy density (HED) and inertial confinement fusion (ICF) diagnostics such as those at the National Ignition Facility and the Sandia Z-Machine. Calibration of the spectral reflectivity and resolution of these x-ray diagnostics enable absolute determination of the x-ray flux and wavelengths generated in the HED and ICF experiments. Measurement of the optic point spread function is used to determine spatial resolution of the optic. This facility was constructed to measure (1) the x-ray reflectivity to ±5% over a spectral range from 5 to 60 keV; (2) point spread functions with a resolution of 50 µm (currently) and 13 µm (future) in the image plane; and (3) optic distance relative to the x-ray source and detector to within ±100 µm in each dimension. This article describes the capabilities of the calibration facility, concept of operations, and initial data from selected x-ray optics.

11.
Rev Sci Instrum ; 89(10): 10G115, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399891

RESUMO

A new Wolter x-ray imager has been developed for the Z machine to study the emission of warm (>15 keV) x-ray sources. A Wolter optic has been adapted from observational astronomy and medical imaging, which uses curved x-ray mirrors to form a 2D image of a source with 5 × 5 × 5 mm3 field-of-view and measured 60-300-µm resolution on-axis. The mirrors consist of a multilayer that create a narrow bandpass around the Mo Kα lines at 17.5 keV. We provide an overview of the instrument design and measured imaging performance. In addition, we present the first data from the instrument of a Mo wire array z-pinch on the Z machine, demonstrating improvements in spatial resolution and a 350-4100× increase in the signal over previous pinhole imaging techniques.

12.
Rev Sci Instrum ; 87(11): 11E341, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910560

RESUMO

Experiments were performed to mitigate the hard x-ray background commonly observed in backlit pinhole imagers. The material of the scaffold holding the primary backlighter foil was varied to reduce the laser-plasma instabilities responsible for hot electrons and resulting hard x-ray background. Radiographic measurements with image plates showed a factor of >25 decrease in x-rays between 30 and 67 keV when going from a plastic to Al or V scaffold. A potential design using V scaffold offers a signal-to-background ratio of 6:1, a factor of 2 greater than using the bare plastic scaffold.

13.
Rev Sci Instrum ; 87(11): 11D831, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910335

RESUMO

Ultra-intense short pulse lasers incident on solid targets (e.g., thin Au foils) produce well collimated, broad-spectrum proton beams. These proton beams can be used to characterize magnetic fields, electric fields, and density gradients in high energy-density systems. The LLNL-Imaging Proton Spectrometer (L-IPS) was designed and built [H. Chen et al., Rev. Sci. Instrum. 81, 10D314 (2010)] for use with such laser produced proton beams. The L-IPS has an energy range of 50 keV-40 MeV with a resolving power (E/dE) of about 275 at 1 MeV and 21 at 20 MeV, as well as a single spatial imaging axis. In order to better characterize the dispersion and imaging capability of this diagnostic, a 3D finite element analysis solver is used to calculate the magnetic field of the L-IPS. Particle trajectories are then obtained via numerical integration to determine the dispersion relation of the L-IPS in both energy and angular space.

14.
Rev Sci Instrum ; 85(11): 11E602, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430348

RESUMO

Experiments at the Trident Laser Facility have successfully demonstrated the use of x-ray fluorescence imaging (XRFI) to diagnose shocked carbonized resorcinol formaldehyde (CRF) foams doped with Ti. One laser beam created a shock wave in the doped foam. A second laser beam produced a flux of vanadium He-α x-rays, which in turn induced Ti K-shell fluorescence within the foam. Spectrally resolved 1D imaging of the x-ray fluorescence provided shock location and compression measurements. Additionally, experiments using a collimator demonstrated that one can probe specific regions within a target. These results show that XRFI is a capable alternative to path-integrated measurements for diagnosing hydrodynamic experiments at high energy density.

15.
Rev Sci Instrum ; 85(11): 11E610, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430356

RESUMO

Hard x-rays from laser-produced hot electrons (>10 keV) in backlit pinhole imagers can give rise to a background signal that decreases signal dynamic range in radiographs. Consequently, significant uncertainties are introduced to the measured optical depth of imaged plasmas. Past experiments have demonstrated that hard x-rays are produced when hot electrons interact with the high-Z pinhole substrate used to collimate the softer He-α x-ray source. Results are presented from recent experiments performed on the OMEGA-60 laser to further study the production of hard x-rays in the pinhole substrate and how these x-rays contribute to the background signal in radiographs. Radiographic image plates measured hard x-rays from pinhole imagers with Mo, Sn, and Ta pinhole substrates. The variation in background signal between pinhole substrates provides evidence that much of this background comes from x-rays produced in the pinhole substrate itself. A Monte Carlo electron transport code was used to model x-ray production from hot electrons interacting in the pinhole substrate, as well as to model measurements of x-rays from the irradiated side of the targets, recorded by a bremsstrahlung x-ray spectrometer. Inconsistencies in inferred hot electron distributions between the different pinhole substrate materials demonstrate that additional sources of hot electrons beyond those modeled may produce hard x-rays in the pinhole substrate.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...