Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Ultrasound Med ; 20(9): 959-66, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11549156

RESUMO

OBJECTIVE: To assess the use of intraoperative sonography for localization of breast masses at excisional biopsy, with specimen and surgical bed sonography to confirm excision. METHODS: A computer search of the 5-year period from January 1993 through January 1998 revealed 138 consecutive women referred for sonographically guided excisional biopsy of 148 masses; 35 masses were excluded because they had no postoperative mammograms. One hundred thirteen masses constituted the study group. Specimen sonography (n = 60) or surgical bed sonography (n = 53) was performed as the initial evaluation to confirm excision, but ultimately, surgical bed sonography may have been necessary after specimen sonography, and specimen sonography may have been necessary after surgical bed sonography. The miss rates determined by postoperative imaging were calculated for each group and compared with those of mammographically guided needle localization series from the literature. RESULTS: Follow-up physical examination and mammography showed no residual mass in the region of surgery in any patient. However, follow-up sonography had 1 miss in the initial specimen sonogram group (1 [1.7%] of 60) and 1 miss in the initial surgical bed group (1 [1.9%] of 53). As shown by the Fisher exact test, there was no significant difference between the miss rates of the 2 initial methods of confirming lesion excision or between the miss rates of these initial methods, both groups combined, and 6 mammographic localization series from the literature. CONCLUSION: Intraoperative breast sonography, using specimen sonography and scanning the surgical bed, has miss rates comparable with those of mammographic needle localization. Follow-up sonography must be performed if there is any doubt of complete excision.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/patologia , Ultrassonografia Mamária , Adulto , Idoso , Biópsia por Agulha/métodos , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Feminino , Humanos , Cuidados Intraoperatórios , Mamografia , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos
2.
Acad Radiol ; 8(8): 698-704, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11508748

RESUMO

RATIONALE AND OBJECTIVES: The purpose of this study was to determine whether the interval change in hepatic colorectal metastases as assessed with serial computed tomographic (CT) scans without contrast material enhancement differs from that as assessed using serial, portal dominant phase, contrast-enhanced CT scans. MATERIALS AND METHODS: Unenhanced and contrast-enhanced abdominal CT scans were obtained in 28 patients. Three radiologists separately reviewed serial unenhanced and contrast-enhanced studies to assess the interval change in liver metastases. These radiologists recorded total number of lesions, bidimensional measurements of the largest lesions (as many as three), and overall impressions regarding the interval change (none, worse, or better). RESULTS: Among the 84 judgments (28 patients x 3 radiologists), comparisons of unenhanced and contrast-enhanced CT studies were concordant in 60 assessments (71%). Nineteen (23%) showed mild disagreement. Of these, contrast-enhanced CT studies demonstrated disease stability when unenhanced CT studies demonstrated otherwise in 11 judgments, whereas unenhanced CT studies demonstrated stability when contrast-enhanced CT studies demonstrated otherwise in eight assessments. Furthermore, of the five marked disagreements, two resulted from a conclusion of interval improvement on unenhanced CT studies and a conclusion of interval worsening on contrast-enhanced CT studies, whereas three demonstrated the opposite. Neither set of serial CT studies systematically resulted in under- or overestimation of disease progression (McNemar Q test, P < .25). CONCLUSION: The authors found no consistent pattern to demonstrate that serial unenhanced or contrast-enhanced CT studies resulted in over- or underestimation of disease progression.


Assuntos
Neoplasias Colorretais/diagnóstico por imagem , Meios de Contraste , Neoplasias Hepáticas/diagnóstico por imagem , Intensificação de Imagem Radiográfica , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Progressão da Doença , Feminino , Humanos , Iotalamato de Meglumina , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Ácidos Tri-Iodobenzoicos
3.
J Ultrasound Med ; 20(7): 749-53; quiz 755, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11444733

RESUMO

PURPOSE: To review the clinical indications, pathologic results, and success rate of all our sonographically guided solid renal mass biopsies over a 5-year period. METHODS: Between 1993 and 1998, 44 consecutive patients underwent sonographically guided percutaneous biopsy of a solid renal mass. Indications included prior history of nonrenal malignancy, metastatic disease of unknown primary origin, previous contralateral nephrectomy for a renal cell neoplasm, a renal transplant mass, suspected renal lymphoma, history of tuberous sclerosis, and poor surgical candidacy. Aspiration biopsies were initially performed with 22- to 18-gauge spinal needles. If the initial cytologic evaluation findings were nondiagnostic, core biopsies were then performed with 20- to 18-gauge core biopsy guns. Dictated sonographic reports of the biopsies were reviewed to determine the following: indication for biopsy, location and size of the renal mass, needle gauge and type, number of needle passes, and complications. Final cytologic and surgical pathologic records were reviewed. RESULTS: Thirty-six (82%) of the 44 biopsy specimens were diagnostic. Aspirated smears were diagnostic in 24 (67%) of these cases, with the diagnosis made on the basis of cell block alone in an additional 2 (6%). A definitive diagnosis came from core biopsy alone in 10 cases (28%). The 18-gauge core needle yielded diagnostic results more reliably than the 20-gauge core needle, and a significant correlation was seen between core biopsy needle size and the rate of diagnostic core samples (P = .017). Pathologic diagnoses included renal cell carcinoma (n = 18), lymphoma (n = 4), oncocytic neoplasm (n = 4), transitional cell carcinoma (n = 2), angiomyolipoma (n = 1), papillary cortical neoplasm (n = 1), and metastatic carcinoma (n = 6). Complications were seen in 4 (9%) of 44 cases; all were treated conservatively. CONCLUSIONS: For specific clinical indications, sonographically guided fine-needle aspiration and core biopsy of a solid renal mass can be performed safely. In many cases, a definitive diagnosis can be made on the basis of fine-needle aspiration alone. However, diagnosis may ultimately require core biopsy, for which 18-gauge core needles would be more reliably diagnostic than 20-gauge needles.


Assuntos
Biópsia/métodos , Carcinoma de Células Renais/patologia , Neoplasias Renais/patologia , Rim/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha/métodos , Carcinoma de Células Renais/diagnóstico por imagem , Feminino , Humanos , Rim/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Ultrassonografia
4.
J Ultrasound Med ; 19(8): 537-41, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10944039

RESUMO

Sonographic guidance is commonly used in the biopsy of focal hepatic lesions, but biopsy for diffuse disease is often non-image-guided. We evaluated the safety and efficacy of real-time sonographically guided random core biopsy in the assessment of diffuse liver disease in 210 patients. The two most common indications for biopsy were viral hepatitis (in 113 patients) and elevated liver function test results of unknown cause (in 54 patients). Ultrasonography and pathology reports were reviewed retrospectively to determine number of needle passes and final diagnoses. Adequate tissue was obtained in all 210 patients, with 259 of 269 (96%) passes having been successful. Specimens were submitted for light microscopy and other tests as indicated. No difference in success rates was found for right and left lobe biopsies. No major complications occurred. Minor complications occurred in 10 of 210 (4.8%) patients and were self-limited. Sonographically guided core liver biopsy is a safe and effective method for the diagnosis of liver disease.


Assuntos
Biópsia por Agulha/instrumentação , Hepatopatias/diagnóstico por imagem , Fígado/diagnóstico por imagem , Adulto , Idoso , Feminino , Hepatite Viral Humana/diagnóstico por imagem , Hepatite Viral Humana/patologia , Humanos , Fígado/patologia , Hepatopatias/patologia , Testes de Função Hepática , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Ultrassonografia
6.
AJR Am J Roentgenol ; 171(5): 1245-50, 1998 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9798855

RESUMO

OBJECTIVE: We evaluated the ability of power Doppler sonography to show increased soft-tissue blood flow in patients with reflex sympathetic dystrophy of the lower extremity. SUBJECTS AND METHODS: Power Doppler sonography was performed in 30 patients with reflex sympathetic dystrophy of the lower extremity and in 26 asymptomatic control subjects. The bilateral power Doppler sonograms that were obtained of the soft tissues of the dorsum of the foot of each subject were grouped in pairs, and three sonologists who were unaware of clinical information independently reviewed the images. Images were evaluated for the amount of power Doppler signal shown on the following scale: 1 = no flow or minimal flow; 2 = mild flow; 3 = moderate flow; and 4 = marked flow. RESULTS: More power Doppler flow was seen in the patients with reflex sympathetic dystrophy than in the control subjects (p < .005). In addition, side-to-side asymmetry of flow was seen in patients, but this trend was not statistically significant (p < .20). Receiver operating characteristic (ROC) analysis showed that combined flow and asymmetry were more related to reflex sympathetic dystrophy than either parameter alone (area under the ROC curve: for flow, 0.748; for asymmetry, 0.566; for both, 0.799). We found that when the sum of power Doppler flow in both feet was greater than or equal to five, and asymmetry of flow was greater than or equal to one, the sensitivity of power Doppler sonography for reflex sympathetic dystrophy was 73% and the specificity was 92%. CONCLUSION: Patients with reflex sympathetic dystrophy of the lower extremity have increased power Doppler flow compared with asymptomatic control subjects. Patients may also exhibit more side-to-side asymmetry of flow than control subjects.


Assuntos
Pé/irrigação sanguínea , Distrofia Simpática Reflexa/fisiopatologia , Ultrassonografia Doppler , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Distrofia Simpática Reflexa/diagnóstico por imagem , Fluxo Sanguíneo Regional , Sensibilidade e Especificidade
7.
AJR Am J Roentgenol ; 169(5): 1449-51, 1997 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9353478

RESUMO

OBJECTIVE: We investigated the usefulness of high-resolution sonography to localize superficial soft-tissue masses and to guide needle sampling for recurrent malignancy. MATERIALS AND METHODS: High-resolution sonography (10-MHz) was used to locate and guide needle sampling of 16 palpable and eight impalpable superficial masses suggestive of recurrent malignancy in 23 patient (12 men, 11 women; 34-85 years old). After detection, 22 (92%) of the masses were immediately sampled by fine-needle aspiration with 18- to 25-gauge needles and two (8%) were sampled by a 20-gauge core gun. RESULTS: Diagnostic material was obtained without complication from all 24 masses and proved positive for recurrent disease in 13 (54%). Ten (63%) of 16 palpable and three (38%) of eight impalpable masses proved positive for recurrent malignancies. One third of superficial soft-tissue masses were detected by imaging only, and of the masses not revealed on imaging, three (23%) of 13 were the site of first recurrence. Most nonnodal superficial masses (8/13) were benign, unlike the lymph nodes, of which three (27%) of 11 were benign. CONCLUSION: Not all early recurrent malignancies within the skin and subcutaneous tissues are detected by clinical examination. High-resolution sonography provided us with a rapid, safe, and accurate means of localizing and then guiding needle biopsies of superficial soft-tissue masses suggestive of recurrent malignancy.


Assuntos
Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/patologia , Neoplasias Cutâneas/diagnóstico por imagem , Neoplasias Cutâneas/patologia , Neoplasias de Tecidos Moles/diagnóstico por imagem , Neoplasias de Tecidos Moles/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ultrassonografia
8.
J Surg Oncol ; 64(1): 63-7, 1997 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9040803

RESUMO

BACKGROUND: Intraoperative ultrasound has been shown to provide significant assistance in operative staging and management of patients with liver tumors during open surgery. The availability of the 5.0-7.5 Mhz semiflexible ultrasound transducer with gray-scale, color and spectral Doppler capabilities can provide similar information laparoscopically. METHODS: Twenty-four consecutive patients with liver tumors (18 metastatic and six primary), in technically resectable locations determined by a variety of conventional imaging studies, were brought to the operating room. There was no known extrahepatic disease, and there was no recurrence at the primary site in the metastatic subgroup. These patients were evaluated intraoperatively with laparoscopy and intraoperative laparoscopic ultrasound to assess resectability prior to performing a major laparotomy. Laparoscopy was successful in 23 of the patients and in 19 of 23, laparoscopic ultrasound was also employed, using the 5.0-7.5 MHz semiflexible transducer. The use of the open entry technique, selection of alternate entry sites, coupled with expertise in laparoscopic lysis of adhesions, has allowed safe laparoscopic tumor staging. RESULTS: The laparoscopic evaluation was aborted only once due to dense adhesions, despite the fact that 67% of the patients had undergone previous abdominal surgery. There was only one complication: bleeding from a liver biopsy in an unresectable cirrhotic patient, necessitating laparotomy. Laparoscopy and ultrasound together predicted nonresectability in six of eight unresectable patients, all of whom were spared an unnecessary laparotomy. CONCLUSIONS: Laparoscopic ultrasonographic evaluation for the staging of liver tumors should be a prerequisite to definitive laparotomy, with the objective of avoiding unnecessary surgery.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Ultrassonografia Doppler em Cores , Adulto , Idoso , Carcinoma Hepatocelular/patologia , Feminino , Humanos , Período Intraoperatório , Laparoscopia , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias
9.
Tech Urol ; 2(3): 121-5, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-9118418

RESUMO

Urolithiasis is one of the most common causes of pain in pregnancy. Renal calculi can create a diagnostic and therapeutic challenge; left untreated, they can adversely affect maternal and fetal outcome. Although most cases of obstructive uropathy can be managed conservatively, some require relief of obstruction, usually by placement of a ureteral stent. We describe the use of ultrasound to identify an obstructed collecting system and provide guidance for placement of a double-pigtail ureteral stent in two pregnant patients. The technique used to manipulate the guide wire and stent into the renal pelvis under real-time ultrasound monitoring is discussed.


Assuntos
Complicações na Gravidez/terapia , Stents , Cálculos Ureterais/terapia , Obstrução Ureteral/terapia , Adulto , Feminino , Humanos , Hidronefrose/diagnóstico por imagem , Hidronefrose/terapia , Pelve Renal , Gravidez , Complicações na Gravidez/diagnóstico por imagem , Ultrassonografia , Cálculos Ureterais/diagnóstico por imagem , Obstrução Ureteral/diagnóstico por imagem
10.
Radiology ; 199(3): 717-20, 1996 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8637994

RESUMO

PURPOSE: To determine the effects of level of training and other factors on the rate of discrepant interpretation of emergency body computed tomographic (CT) scans by trainees and staff radiologists. MATERIALS AND METHODS: Five hundred ninety-eight consecutive emergency CT studies were prospectively interpreted by radiology residents or board-certified body imaging fellows over a 12-month period. Each interpretation was reviewed within 12 hours by an attending body CT radiologist. Major discrepancies between staff radiologists' and trainees' interpretations were defined and those with the potential to affect immediate patient therapy; minor discrepancies were defined ad those without such potential. The effects on discrepancy rates were examined for abnormal versus normal CT findings and trauma versus nontrauma cases. RESULTS: Major and minor discrepancy rates were 1.2% and 6.5%, respectively, between interpretations made by the trainee and the staff radiologist. Overall, fellows demonstrated statistically significantly lower discrepancy rates than did senior of junior residents (5.9%, 13.7%, and 13.3%, respectively). The discrepancy rate was higher when CT findings were abnormal than when they were normal (13.5% vs 2.6%). There were no differences between discrepancy rates for trauma and nontrauma cases. CONCLUSION: Experience appeared to decrease discrepancy rates. Trainees were more likely to miss findings than to read normal scans as abnormal.


Assuntos
Radiologia/educação , Tomografia Computadorizada por Raios X , Certificação , Erros de Diagnóstico , Emergências , Humanos , Internato e Residência , Estudos Prospectivos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Ferimentos e Lesões/diagnóstico por imagem
11.
J Ultrasound Med ; 15(4): 288-95, 1996 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8683663

RESUMO

This study evaluated the ability of laparoscopic ultrasonography to detect, localize, and characterize focal liver masses. Laparoscopic ultrasonography and CT portography of the liver were performed in 13 patients with known or suspected malignancy. Laparoscopic ultrasonography directly influenced surgical management in four (31%) cases; three by detection of small focal masses and one by exclusion of masses suspected on CT portography. Laparoscopic ultrasonography provided guidance for biopsy or added important anatomic information in three cases. Laparoscopic ultrasonography was complementary to CT portography but added no additional information in three cases, and it failed to provide any information in two cases. Laparoscopic ultrasonography was falsely negative in one case. In this preliminary series, laparoscopic ultrasonography assisted surgeons in critical decision-making by either providing important new information, clarifying questionable areas, or complementing CT portography.


Assuntos
Laparoscopia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Fígado/diagnóstico por imagem , Adulto , Idoso , Estudos de Avaliação como Assunto , Feminino , Hepatectomia , Humanos , Neoplasias Hepáticas/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Ultrassonografia/métodos
12.
Radiology ; 194(3): 851-7, 1995 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-7862990

RESUMO

PURPOSE: To evaluate a semiflexible ultrasound (US) transducer inserted through a laparoscopic port to image abdominal structures. MATERIALS AND METHODS: Laparoscopic US with a 9.6-mm-diameter, 5.0-7.5-MHz semiflexible transducer with gray-scale, color, and spectral Doppler capabilities was performed in three miniature swine and in 25 patients with a variety of abdominal abnormalities. RESULTS: This miniature US probe was used to locate normal structures such as blood vessels, allowing the surgeon to decide the best approach for dissection. Color and spectral Doppler US proved especially useful in differentiating vascular from nonvascular structures. The presence or absence of stones in the gallbladder and common bile duct was readily determined. It was possible to detect masses and to provide guidance for their aspiration or biopsy within abdominal organs. In 10 cases (40%), laparoscopic US helped the surgeon make the decision for clinical management and altered the surgical procedures. CONCLUSION: Laparoscopic US was useful in assisting laparoscopic evaluation of abnormalities in the abdomen.


Assuntos
Ultrassonografia Doppler em Cores/instrumentação , Ultrassonografia Doppler/instrumentação , Abdome/diagnóstico por imagem , Animais , Colecistectomia Laparoscópica , Desenho de Equipamento , Feminino , Humanos , Cuidados Intraoperatórios/instrumentação , Laparoscopia , Masculino , Pessoa de Meia-Idade , Suínos , Porco Miniatura , Transdutores , Ultrassonografia Doppler/métodos , Ultrassonografia Doppler em Cores/métodos
13.
J Magn Reson Imaging ; 4(6): 767-71, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-7865935

RESUMO

Magnetic resonance (MR) imaging with arterial portography (MRAP) was compared with computed tomography with arterial portography (CTAP) and conventional MR imaging for preoperative evaluation of hepatic masses in eight patients (nine studies). Twenty contiguous, 10-mm-thick-section CTAP images were obtained. MR imaging included T1- and T2-weighted spin-echo and fast multiplanar SPGR (spoiled gradient-recalled acquisition in the steady state) techniques. For MRAP, 0.1 mmol/kg gadopentetate dimeglumine was injected into the superior mesenteric artery. Portographic-phase, 8-mm-thick-section, axial SPGR images were first obtained, followed by "systemic phase" SPGR images. Lesions were seen best on the portographic-phase MRAP images and were less conspicuous on the systemic-phase MRAP, CTAP and conventional MR images. Of 19 visualized lesions, 18 were seen with MRAP; however; five subcentimeter lesions seen with MRAP were not seen with conventional MR imaging or CTAP. Systemic recirculation of iodinated contrast material from the bolus and from previous angiography is a potential limitation of CTAP. For both CTAP and MRAP, optimal results are expected if all images are obtained during a single breath hold, within seconds of the onset of contrast agent administration.


Assuntos
Hepatopatias/diagnóstico por imagem , Hepatopatias/diagnóstico , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Portografia/métodos , Tomografia Computadorizada por Raios X , Meios de Contraste , Diatrizoato de Meglumina , Combinação de Medicamentos , Gadolínio , Gadolínio DTPA , Humanos , Aumento da Imagem , Jejuno/diagnóstico por imagem , Jejuno/patologia , Rim/diagnóstico por imagem , Rim/patologia , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/diagnóstico por imagem , Meglumina , Artéria Mesentérica Superior , Compostos Organometálicos , Ácido Pentético/análogos & derivados , Estudos Prospectivos , Intensificação de Imagem Radiográfica , Respiração , Baço/diagnóstico por imagem , Baço/patologia , Tomografia Computadorizada por Raios X/métodos
14.
J Ultrasound Med ; 13(4): 281-4, 1994 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-7932992

RESUMO

The ability of a high-frequency miniature ultrasonographic transducer to image the anatomy of the anal sphincter complex was investigated in 20 normal subjects. A 9 Fr catheter containing a 12.5 MHz transducer was inserted into the anal canal. Cross-sectional ultrasonographic images of the canal were acquired as the catheter was advanced through the canal into the distal rectum. Three analog images were digitally stored on a computer system, and measurements of the anal sphincters were made from an eight octant grid by two independent investigators. In all 20 subjects the hypoechoic mucosa, hyperechoic submucosa, and hypoechoic internal anal sphincter (IAS) were identified. The first band of the external anal sphincter (EAS) was imaged in 12 of 20 subjects. The mean width of the IAS was 3.5 +/- 0.5 mm (range, 2.6-4.3 mm). The mean width of the first band of the EAS was 2.3 +/- 0.5 mm (range, 1.6-3.2 mm). High-resolution sonography of the anal canal allows detailed evaluation of anatomic structures that cannot be achieved by conventional imaging technology.


Assuntos
Canal Anal/diagnóstico por imagem , Cateterismo/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Transdutores , Ultrassonografia/instrumentação , Ultrassonografia/métodos
15.
J Ultrasound Med ; 12(10): 563-6, 1993 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8246333

RESUMO

A 20 MHz ultrasound transducer housed in a 6.2 Fr catheter was used to image human esophageal autopsy specimens from six cadavers. Histologic sections taken from the areas imaged were correlated with cross-sectional sonographic images. Six echo layers were seen in the non-fluid-filled esophagus whereas seven echo layers were seen in the fluid-filled esophagus. These seven layers correspond to the following histologic structures: first hyperechoic layer--mucosa (including squamous epithelium and lamina propria); second thin hypoechoic layer--muscularis mucosae; third very bright hyperechoic layer--submucosa; fourth hypoechoic layer--circular smooth muscle; fifth thin hyperechoic layer--intermuscular connective tissue; sixth hypoechoic layer--longitudinal smooth muscle; seventh hyperechoic layer--adventitia.


Assuntos
Esôfago/diagnóstico por imagem , Adulto , Idoso , Esôfago/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Transdutores , Ultrassonografia
17.
Gastroenterology ; 105(1): 31-9, 1993 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8514059

RESUMO

BACKGROUND: The aim of this study is to apply high-resolution endoluminal sonography (HRES) to the study of the esophageal disease in systemic sclerosis (SSc). METHODS: An HRES transducer was used to image the esophagus. Autopsy specimens of normal and SSc esophagi were imaged to define a hyperechoic abnormality in the normally hypoechoic muscularis propria. The presence or absence of this hyperechoic abnormality of the esophagus in SSc patients was compared with sonographic findings in normal volunteers. The degree of the hyperechoic abnormality was correlated with the results of functional esophageal studies including esophageal motility, lower esophageal sphincter pressure, and 24-hour pH monitoring in SSc patients. RESULTS: A hyperechoic abnormality in the normally hypoechoic muscularis propria on HRES seemed to correspond with the presence of fibrosis on histological sections from the distal esophagus in SSc autopsy specimens. A significant difference was found in the presence of this hyperechoic abnormality in patients with SSc when compared with normal controls (P < 0.001). Finally, there were strong positive correlations between the degree of this hyperechoic abnormality and esophageal manometric abnormalities (r = 0.89; P < 0.001) and supine (r = 0.74; P < 0.01) and total (r = 0.70; P < 0.02) acid reflux on 24-hour pH monitoring. CONCLUSIONS: HRES is a sensitive new method to determine the presence or absence of hyperechoic abnormalities in the muscularis propria and to predict functional abnormalities of the esophagus in patients with SSc.


Assuntos
Esôfago/diagnóstico por imagem , Escleroderma Sistêmico/diagnóstico por imagem , Adulto , Idoso , Esofagoscopia , Esôfago/patologia , Esôfago/fisiopatologia , Feminino , Refluxo Gastroesofágico/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Escleroderma Sistêmico/patologia , Escleroderma Sistêmico/fisiopatologia , Ultrassonografia
18.
Radiology ; 187(2): 363-6, 1993 May.
Artigo em Inglês | MEDLINE | ID: mdl-8475273

RESUMO

To image esophageal and gastric varices qualitatively and to measure esophageal varices quantitatively, 29 patients with portal hypertension underwent transnasal esophageal and gastric ultrasonography (US). Twenty-three patients underwent standard endoscopy. Endoluminal US demonstrated the varices as anechoic areas with communications in the submucosal, periesophageal, and perigastric regions, as well as ascites visualized through the gastric wall. Interobserver variation between two investigators for measurements of the largest esophageal varix in each patient was r value of .99 for diameter, r value of .99 for cross-sectional surface area, and r value of .98 for circumference. Endoscopy for evaluation of gastric varices had a sensitivity of 48% and a specificity of 50% and for evaluation of esophageal varices had a sensitivity of 94% and a specificity of 17%. Periesophageal and perigastric varices could not be visualized at endoscopy. Transnasal esophageal US, a new imaging technique with which to detect and measure esophageal varices, is a more sensitive modality than endoscopy for the detection of gastric varices.


Assuntos
Varizes Esofágicas e Gástricas/diagnóstico por imagem , Adolescente , Adulto , Idoso , Criança , Endoscopia do Sistema Digestório , Feminino , Humanos , Masculino , Métodos , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Ultrassonografia
19.
J Ultrasound Med ; 12(1): 49-54, 1993 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8455221

RESUMO

Miniature ultrasound transducers (12.5 MHz) housed in 9 Fr catheters were passed through a laparoscope or mediastinoscope to image a variety of normal and abnormal structures within the peritoneal cavity and mediastinum in 20 patients. These transducers made it possible to visualize the gallbladder and bile ducts and evaluate for the presence of stones, to detect masses and provide guidance for their aspiration or biopsy, and to image the internal structures of the ovary and fallopian tube. In addition, these miniature transducers were used to locate such normal vital structures as blood vessels, thereby allowing the surgeon to decide on the best approach for dissection during mediastinoscopy. During conventional surgery, the surgeon or gynecologist can palpate an area of abnormality not directly visualized. However, during laparoscopy and mediastinoscopy direct palpation is not possible. Therefore, it is important to find another method to determine what structures lie beneath the visualized surface. These miniature ultrasound transducers appear to offer a means for making such determinations.


Assuntos
Cateterismo/instrumentação , Laparoscópios , Laparoscopia/métodos , Mediastinoscópios , Mediastinoscopia/métodos , Mediastino/diagnóstico por imagem , Cavidade Peritoneal/diagnóstico por imagem , Transdutores , Adulto , Idoso , Colecistectomia Laparoscópica , Colelitíase/diagnóstico por imagem , Colelitíase/patologia , Endometriose/diagnóstico por imagem , Endometriose/patologia , Desenho de Equipamento , Feminino , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Linfoma/diagnóstico por imagem , Linfoma/patologia , Masculino , Mediastino/patologia , Pessoa de Meia-Idade , Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Ovarianas/patologia , Cavidade Peritoneal/patologia , Ultrassonografia/instrumentação
20.
Radiology ; 184(3): 721-7, 1992 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-1509056

RESUMO

High-frequency catheter-based ultrasound (US) transducers can be inserted into the esophagus transnasally to evaluate esophageal wall structures. Studies were performed in two sheep esophagus specimens in vitro, in 17 healthy human subjects, and in 16 patients with esophageal abnormalities (eight with achalasia, four with scleroderma, three with esophageal carcinoma, and one with esophagitis). In the sheep specimens, endoluminal US delineated seven layers of the esophageal wall; these results correlated closely with histologic findings. Real-time US of the normal esophageal wall was performed during resting and swallowing. Muscles at the lower esophageal sphincter (LES) were shown to be thicker than muscles in the body of the esophagus. Thickening of the muscular layers at the LES in achalasia, dilated blood vessels within the submucosa in esophagitis, and fibrotic changes within the muscular layers in scleroderma were demonstrated. Extramural structures adjacent to the esophagus were also seen. These preliminary results suggest that transnasal esophageal US may become an important diagnostic tool in evaluation of the esophagus.


Assuntos
Esôfago/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Animais , Acalasia Esofágica/diagnóstico por imagem , Feminino , Humanos , Masculino , Métodos , Pessoa de Meia-Idade , Ovinos , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...