Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomed Opt ; 21(12): 126010, 2016 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-27997633

RESUMO

A combination of approaches to the image analysis in cross-polarization optical coherence tomography (CP OCT) and high-resolution imaging by nonlinear microscopy and atomic force microscopy (AFM) at the different stages of atherosclerotic plaque development is studied. This combination allowed us to qualitatively and quantitatively assess the disorganization of collagen in the atherosclerotic arterial tissue (reduction and increase of CP backscatter), at the fiber (change of the geometric distribution of fibers in the second-harmonic generation microscopy images) and fibrillar (violation of packing and different nature of a basket-weave network of fibrils in the AFM images) organization levels. The calculated CP channel-related parameters are shown to have a statistically significant difference between stable and unstable (also called vulnerable) plaques, and hence, CP OCT could be a potentially powerful, minimally invasive method for vulnerable plaques detection.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Microscopia de Força Atômica/métodos , Placa Aterosclerótica/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Algoritmos , Colágeno , Vasos Coronários/diagnóstico por imagem , Humanos
2.
J Biophotonics ; 9(10): 1009-1020, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-26604168

RESUMO

We combined cross-polarization optical coherence tomography (CP OCT) and non-linear microscopy based on second harmonic generation (SHG) and two-photon-excited fluorescence (2PEF) to assess collagen and elastin fibers and other vascular structures in the development of atherosclerosis, including identification of vulnerable plaques, which remains an important clinical problem and imaging application. CP OCT's ability to visualize tissue birefringence and cross-scattering adds new information about the microstructure and composition of the plaque. However its interpretation can be ambiguous, because backscattering contrast may have a similar appearance to the birefringence related fringes. Our results represent a step towards minimally invasive characterization and monitoring of different stages of atherosclerosis, including vulnerable plaques. CP OCT image of intimal thickening in the human coronary artery. The dark stripe in the cross-polarization channel (arrow) is a polarization fringe related to the phase retardation between two eigen polarization states. It is histologically located in the area of the lipid pool, however this stripe is a polarization artifact, rather than direct visualization of the lipid pool.


Assuntos
Vasos Coronários/diagnóstico por imagem , Microscopia de Fluorescência por Excitação Multifotônica , Placa Aterosclerótica/diagnóstico por imagem , Tomografia de Coerência Óptica , Aterosclerose , Birrefringência , Colágeno/química , Elastina/química , Humanos , Sensibilidade e Especificidade
3.
Lasers Surg Med ; 47(5): 411-20, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25920077

RESUMO

BACKGROUND AND OBJECTIVES: Uncovering implants with lasers, while bloodless, has been associated with a risk of implant and bone overheating. The present study evaluated the effect of using a new generation of high-power diode lasers on the temperature of a dental implant and the surrounding tissues using an in vitro model. STUDY DESIGN/MATERIALS AND METHODS: The implant temperature was measured at three locations using micro thermocouples. Collateral thermal damage of uncovered soft tissues was evaluated using NTBC stain. Implant temperature rise during and collateral thermal soft-tissue damage following implant uncovering with and without tissue air-cooling was studied using both the classic operational mode and the new thermo-optically powered (TOP) technology. RESULTS: For the classic surgical mode using a cork-initiated tip and constant laser power set at 3.4 W, the maximum temperature rise in the coronal and apical parts of the implant was 23.2 ± 4.1°Ð¡ and 9.5 ± 1.8°Ð¡, respectively, while 1.5 ± 0.5 mm of collateral thermal damage of the soft tissue surrounding the implant model occurred. Using the TOP surgical tip with constant laser power reduced implant overheating by 30%; collateral thermal soft-tissue damage was 0.8 ± 0.2 mm. Using the TOP surgical mode with a tip temperature setting of 800°C and air-cooling reduced the implant temperature rise by more than 300%, and only 0.2 ± 0.1 mm of collateral thermal soft-tissue damage occurred, typical for optimized CO2 laser surgery. Furthermore, use of the new generation diode technology (TOP surgical mode) appeared to reduce the time required for implant uncovering by a factor of two, compared to the standard surgical mode. CONCLUSIONS: Use of the new generation diode technology (TOP surgical mode) may significantly reduce overheating of dental implants during uncovering and seems to be safer for the adjacent soft and hard tissues. Use of such diode lasers with air-cooling can radically reduce the rise in implant temperatures (by more than three times), potentially making this technology safe and effective for implant uncovering.


Assuntos
Queimaduras/prevenção & controle , Implantes Dentários , Terapia a Laser/instrumentação , Lasers Semicondutores/uso terapêutico , Mucosa Bucal/lesões , Animais , Queimaduras/etiologia , Bovinos , Terapia a Laser/efeitos adversos , Modelos Biológicos , Modelos Dentários , Lesões dos Tecidos Moles/etiologia , Lesões dos Tecidos Moles/prevenção & controle , Técnicas de Cultura de Tecidos
4.
Lasers Med Sci ; 28(1): 25-31, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22322393

RESUMO

In this study a minimally invasive microsurgical approach was used for laser patterned microcoagulation (LPM) to initiate gingival and oral mucosal tissue regeneration. We performed a feasibility assessment and histological examination of laser damage and regeneration in the gingiva and oral mucosa using an animal model. The study animals comprised 18 healthy rabbits which were treated in vivo with single pulses from a diode laser at a wavelength of 980 nm and a power of up to 20 W applied to the gingival and oral mucosa at multiple time points. Biopsies were stained with hematoxylin and eosin, nitroblue tetrazolium chloride and picrosirius red, and evaluated by two pathologists blinded to the parameters and date of laser exposure. Histological analysis revealed that the continuity of the epithelial basal cell layer had been reestablished by 1-2 days after LPM, and complete epithelial regeneration had occurred by 7-12 days. A pronounced reactive inflammation developed in the column area 1 day after treatment. High activity of fibroblasts producing new collagen participated in the formation of a network of new thin-wall blood vessel. By the 28th day the tissue structure was almost completely restored with a similar increase of vascularity, and there were no signs of scarring. By the 90th day, tissue structure was completely restored, indicating complete healing. A single LPM treatment induces a wound healing response in the oral mucosa, showing the potential of LPM for the initiation of oral mucosa and gingival regeneration. Complete healing observed in 3 months after treatment with no keratinization change or scar tissue formation.


Assuntos
Fotocoagulação a Laser/métodos , Lasers Semicondutores , Procedimentos Cirúrgicos Minimamente Invasivos , Mucosa Bucal/efeitos da radiação , Mucosa Bucal/cirurgia , Procedimentos Cirúrgicos Bucais/métodos , Animais , Biópsia , Colágeno , Fibroblastos , Modelos Animais , Coelhos , Regeneração , Coloração e Rotulagem
5.
Phys Rev E Stat Nonlin Soft Matter Phys ; 80(3 Pt 1): 031903, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19905142

RESUMO

High-resolution optical coherence tomography is used to study the onset of a large-scale convective motion in free-standing thin films of adjustable thickness containing suspensions of swimming aerobic bacteria. Clear evidence is found that beyond a threshold film thickness there exists a transition from quasi-two-dimensional collective swimming to three-dimensional turbulent behavior. The latter state, qualitatively different from bioconvection in dilute bacterial suspensions, is characterized by enhanced diffusivities of oxygen and bacteria. These results emphasize the impact of self-organized bacterial locomotion on the onset of three-dimensional dynamics, and suggest key ingredients necessary to extend standard models of bioconvection to incorporate effects of large-scale collective motion.


Assuntos
Bacillus subtilis/citologia , Bacillus subtilis/metabolismo , Movimento , Suspensões , Tomografia de Coerência Óptica
6.
J Endourol ; 19(5): 570-4, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15989448

RESUMO

BACKGROUND AND PURPOSE: Optical coherence tomography (OCT) is a new modality that allows noninvasive examination of the internal structure of biological tissue in vivo with a spatial resolution of 10 to 15 microm. This study evaluated the clinical application of OCT to determine epithelial and subepithelial anatomic structure and invasiveness of bladder epithelial lesions. MATERIALS AND METHODS: The OCT examination was performed with a 980-nm 10 mW superluminescent diode using a 2.7-mm-diameter optical fiber positioned cystoscopically. A total of 261 scans of 1.5 seconds' duration, which generated 200 x 200-pixel images, were performed on 87 areas in 24 patients at high risk of having transitional-cell carcinoma (TCC). Lesions, visually suspect, and normal areas were photographed, scanned, and biopsied. The scans were evaluated independently before comparison with histopathology findings. RESULTS: Of the 87 areas, 29 of 36 visually suspect areas and 35 of 35 normal areas, were correctly diagnosed with OCT. Of the 16 areas with papillary TCC, all 16 were diagnosed correctly as tumor, and 9 of 10 were diagnosed correctly as invasive, including 6 with lamina propria invasion only. Papillary and flat tumors, carcinoma in situ, inflammation, chronic cystitis, and von Brunn's nests were scanned. Overall, OCT had a sensitivity of 100%, overall specificity of 89%, positive predictive value of 75%, and negative predictive value of 100%. The accuracy was 92%. The positive predictive value for invasion was 90%. CONCLUSION: Optical coherence tomography is a simple, portable, promising modality for evaluation of bladder lesions and depth of tumor penetration. Further refinement of this technology may lead to the development of an optical surrogate for biopsy.


Assuntos
Carcinoma de Células de Transição/diagnóstico , Técnicas de Diagnóstico Urológico , Tomografia de Coerência Óptica , Neoplasias da Bexiga Urinária/diagnóstico , Reações Falso-Positivas , Humanos , Lasers , Sensibilidade e Especificidade
7.
J Urol ; 167(3): 1492-6, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11832776

RESUMO

PURPOSE: Optical coherence tomography is a new imaging modality capable of imaging luminal surface of biological tissue in the near infrared range with a spatial resolution close to the cellular level. We identified characteristic optical coherence tomography patterns for nonproliferative and proliferative inflammation, and malignant alterations of the bladder. MATERIALS AND METHODS: Optical coherence tomography was performed to image the bladder of 66 patients. The probe passed through the operating channel of a cystoscope and was pressed onto the mucosal site of interest. A mucosal biopsy of the image site was obtained. Optical coherence tomography was used to construct 680 images of the bladder and the images were compared with histology slides. RESULTS: Optical coherence tomography images of normal bladder showed 3 layers, namely the mucosa or transitional epithelium, submucosa and smooth muscle. In exudative processes there were poor light scattering areas in the connective tissue layer. Images of bladders with proliferative cystitis revealed nonuniform thickening of the epithelium or hyperplasia. Squamous metaplasia appeared as thicker and less transparent epithelium with a jagged boundary. Images of transitional cell carcinoma were characterized by the complete loss of a regular layered structure of the bladder wall and the penetration depth of optical imaging was slight. CONCLUSIONS: This study provides the characteristic optical coherence tomography pattern of nonproliferative and proliferative inflammation, and the characteristic appearance of severe dysplasia and transitional cell carcinoma. This technique may be useful as a guide for biopsy and for assisting in establishing resection margins.


Assuntos
Cistite/diagnóstico , Tomografia/métodos , Neoplasias da Bexiga Urinária/diagnóstico , Bexiga Urinária/patologia , Carcinoma de Células Escamosas/diagnóstico , Carcinoma de Células de Transição/diagnóstico , Doença Crônica , Estudos de Viabilidade , Humanos , Raios Infravermelhos , Óptica e Fotônica , Bexiga Urinária/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...