Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Scand J Clin Lab Invest ; 81(4): 303-306, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33787440

RESUMO

Presently, bed-side or at home quantification of neutrophils in blood (b-neutrophils) is not practical, because cytometric methods are too expensive and technically demanding. We have explored whether calprotectin concentration in whole blood (b-calprotectin) might be a valid measure of b-neutrophils because this principle might be used in a simple and robust immunoassay device. We obtained heparin blood samples from 77 patients with possible neutropenia, most of them cancer patients treated with cytostatic drugs, and compared b-calprotectin with their b-neutrophils in a simultaneously taken EDTA-blood sample. The Spearman rank correlation coefficient between b-calprotectin and b-neutrophils was 0.986 (p < .0001). In a regression model of b-neutrophils as a function of age, gender, type of hematology instrument, total leukocyte count minus neutrophils, b-calprotectin, and plasma calprotectin (p-calprotectin), only b-calprotectin was a statistically significant predictor. B-neutrophils below 1 × 109/L was unlikely if b-calprotectin was above 50 mg/L. In conclusion, b-calprotectin, without adjusting for p-calprotectin, correlates closely with b-neutrophils and could be used to detect b-neutrophils below 1 × 109/L.


Assuntos
Complexo Antígeno L1 Leucocitário/sangue , Neutrófilos , Adulto , Idoso , Feminino , Humanos , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Neutropenia/sangue , Neutropenia/induzido quimicamente , Análise de Regressão
3.
Scand J Clin Lab Invest ; 79(1-2): 50-57, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30761918

RESUMO

Calprotectin in plasma and blood might prove to be a useful biomarker of inflammation and infection; however, automated methods for analysing the concentration of calprotectin in those materials are lacking. We have validated a fully automated turbidimetric method and present health-related reference limits. Calprotectin was measured by Siemens Advia XPT with the Bühlmann fCAL® turbo test (Bühlmann Laboratories AG, Schönenbuch, Switzerland), a particle enhanced turbidimetric immunoassay for quantification of calprotectin in fecal extracts. Plasma and serum samples were analysed directly, while whole blood was first extracted with M-PER® Mammalian Protein Extraction Reagent (ThermoFisher) and diluted with B-CAL-EX (Bühlmann). We studied analytical imprecision, estimated health-related reference limits and examined the correlation between neutrophil-calprotectin (blood-calprotectin adjusted for plasma-calprotectin) and the neutrophil count. The intermediate ('day-to-day') coefficient of variation was 3.5 and 1.0% for heparin-plasma-calprotectin at 0.52 mg/L and 3.53 mg/L, respectively, and 4.9% for heparin-blood-calprotectin at 50.2 mg/L. Health-related reference limits were 0.470-3.02 mg/L for calprotectin in heparin-plasma, 50.8-182 mg/L for calprotectin in heparin-blood, 0.534-2.41% for the ratio between them and 24.7-33.3 pg for the mean amount of calprotectin per neutrophil. Compared to heparin-plasma, calprotectin concentrations were significantly lower in EDTA-plasma and higher in serum (p < .05). Correlation between neutrophil-calprotectin and the neutrophil count was excellent. We have shown that the Bühlmann fCAL® turbo test can be used to measure calprotectin in plasma and blood.


Assuntos
Imunoensaio/normas , Complexo Antígeno L1 Leucocitário/sangue , Nefelometria e Turbidimetria/normas , Neutrófilos/citologia , Anticoagulantes/química , Ácido Edético/química , Fezes/química , Heparina/química , Humanos , Contagem de Leucócitos , Limite de Detecção , Neutrófilos/metabolismo , Variações Dependentes do Observador , Valores de Referência , Reprodutibilidade dos Testes
4.
Mov Disord ; 25(13): 2156-63, 2010 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-20669305

RESUMO

Genealogical investigation of a large Norwegian family (F04) with autosomal dominant parkinsonism has identified 18 affected family members over four generations. Genetic studies have revealed a novel pathogenic LRRK2 mutation c.4309 A>C (p.Asn1437His) that co-segregates with disease manifestation (LOD = 3.15, θ = 0). Affected carriers have an early age at onset (48 ± 7.7 SD years) and are clinically asymmetric and levodopa responsive. The variant was absent in 623 Norwegian control subjects. Further screening of patients from the same population identified one additional affected carrier (1 of 692) with familial parkinsonism who shares the same haplotype. The mutation is located within the Roc domain of the protein and enhances GTP-binding and kinase activity, further implicating these activities as the mechanisms that underlie LRRK2-linked parkinsonism.


Assuntos
Asparagina/genética , Histidina/genética , Mutação/genética , Doença de Parkinson/genética , Proteínas Serina-Treonina Quinases/genética , Idoso , Idoso de 80 Anos ou mais , Linhagem Celular Transformada , Feminino , Testes Genéticos , Guanosina Trifosfato/metabolismo , Humanos , Serina-Treonina Proteína Quinase-2 com Repetições Ricas em Leucina , Masculino , Pessoa de Meia-Idade , Noruega , Doença de Parkinson/diagnóstico , Proteínas Serina-Treonina Quinases/metabolismo , Escalas de Graduação Psiquiátrica , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Transfecção/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...