Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 15(1): 2350, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38490992

RESUMO

Novel T centers in silicon hold great promise for quantum networking applications due to their telecom band optical transitions and the long-lived ground state electronic spins. An open challenge for advancing the T center platform is to enhance its weak and slow zero phonon line (ZPL) emission. In this work, by integrating single T centers with a low-loss, small mode-volume silicon photonic crystal cavity, we demonstrate an enhancement of the fluorescence decay rate by a factor of F = 6.89. Efficient photon extraction enables the system to achieve an average ZPL photon outcoupling rate of 73.3 kHz under saturation, which is about two orders of magnitude larger than the previously reported value. The dynamics of the coupled system is well modeled by solving the Lindblad master equation. These results represent a significant step towards building efficient T center spin-photon interfaces for quantum information processing and networking applications.

2.
Opt Express ; 29(11): 17365-17374, 2021 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-34154281

RESUMO

We propose a nanoplasmonic interferometric biosensor, which exploits the selective excitation of multipolar plasmonic modes in a nanoslit to provide a novel scheme for highly-sensitive biosensing. In this design, two counter-propagating surface plasmon polaritons interfere at the location of the nanoslit, selectively exciting the dipolar and quadrupolar modes of the structure depending on the phase relationship induced by the analyte. The contrasting radiation patterns produced by these modes result in large changes in the angular distribution of the transmitted light that depends on the analyte concentration. The resultant far-field is numerically modeled and the sensing performance of the structure is assessed, resulting in maximum bulk and surface sensitivities of SB = 1.12 × 105 deg/RIU and SS = 302 deg/RIU, respectively, and a bulk-sensing resolution of the order of 10-8 RIU. The design allows ample control over the trade-off between operating range and resolution through the slit's width, making this platform suitable for a broad range of sensing requirements.


Assuntos
Técnicas Biossensoriais/instrumentação , Interferometria/métodos , Nanotecnologia/métodos , Ressonância de Plasmônio de Superfície/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...