Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Europace ; 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38875490

RESUMO

AIMS: Superior vena cava (SVC) isolation during atrial fibrillation (AF) catheter ablation is limited by the risk of collateral damage to the sinus node and/or the phrenic nerve. Due to its tissue-specificity, we hypothesized the feasibility and safety of pulsed-field ablation (PFA)-based SVC isolation. METHODS AND RESULTS: A hundred and five consecutive patients undergoing PFA-based AF catheter ablation were prospectively included. After pulmonary vein isolation (± posterior wall isolation and electrical cardioversion), SVC isolation was performed using a standardized workflow. Acute SVC isolation was achieved in 105/105 (100%) patients after 6 ± 1 applications. Transient phrenic nerve stunning occurred in 67/105 (64%) patients but without phenic nerve palsy at the end of the procedure and at hospital discharge. Transient high degree sinus node dysfunction occurred in 5/105 (4.7%) patients, with no recurrence at the end of the procedure and until discharge. At the 3-month follow-up visit, no complication occurred. CONCLUSION: SVC isolation using a pentaspline PFA catheter is feasible and safe.

3.
Respir Med Res ; 84: 101025, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37734232

RESUMO

BACKGROUND: Automated detection of sleep apnea (SA) by pacemaker (PM) has been proposed and exhibited good agreement with polysomnography to detect severe SA. We aimed to evaluate the usefulness of SA monitoring algorithm in elderly patients with diastolic dysfunction. METHODS: Consecutive patients referred to the Caen University Hospital for PM implantation between May 2016 and December 2018 presenting isolated diastolic dysfunction were eligible for the study. The respiratory disturbance index (RDI) measured by the PM, and the mean monthly RDI (RDIm), were compared to the apnea hypopnea index (AHI) assessed with portable monitor for severe SA diagnosis. RESULTS: During the study period, 68 patients were recruited, aged of 80.4 ± 8.2 years. 63 patients underwent polygraphy with a portable monitor: 57 presented SA (83.8%), including 16 with severe SA (23.5%). Eight were treated with continuous positive airway pressure (CPAP). We found the RDI cutoff value of 22 events/h to predict severe SA, with 71.4% sensitivity and 65.2%, specificity. The RDIm cutoff value to detect severe SA was 19 events/h, with a sensitivity of 60% and a specificity of 66%. There was a significant reduction in RDI (p = 0.041), RDIm (p = 0.039) and AHI (p = 0.002) after CPAP. Supraventricular arrhythmias were frequent in all patients, regardless of SA severity, considering either episodes occurrence or total burden. CONCLUSION: In a population of elderly patients with PM and diastolic dysfunction, the SA monitoring algorithm was able to detect severe SA, with good diagnostic performance values, but also to provide follow-up data for the patients treated with CPAP.


Assuntos
Marca-Passo Artificial , Síndromes da Apneia do Sono , Idoso , Humanos , Sono , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/terapia , Polissonografia , Algoritmos
5.
Arch Cardiovasc Dis ; 116(5): 265-271, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37179224

RESUMO

BACKGROUND: Conduction system pacing (CSP) is an emerging and promising approach for physiological ventricular pacing. While data from randomized controlled trials are scarce, use of His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP) has increased in France. AIM: To perform a national snapshot survey for cardiac electrophysiologists to evaluate adoption of CSP in France. METHODS: An online survey, distributed to every senior cardiac electrophysiologist in France, was conducted in November 2022. RESULTS: A total of 120 electrophysiologists completed the survey. Eighty-three (69%) respondents reported experience in undertaking CSP procedures and 27 (23%) were planning to start performing CSP in the coming 2 years. The implantation techniques and criteria used for successful implantation differed significantly among operators. The most frequent indications for HBP and LBBAP were high-degree atrioventricular block with left ventricular ejection fraction (LVEF) < 40% (24 and 82%, respectively) or with LVEF ≥ 40% (27 and 74%, respectively), and after failure of a coronary sinus left ventricular lead (27 and 71%, respectively). The limitations respondents most frequently perceived when performing HBP were bad sensing/pacing parameters (45%), increased procedure duration (41%) and risk of lead dislodgement (30%). The most frequently perceived limitations to performing LBBAP were absence of guidelines or consensus (31%), lack of medical training (23%) and increased procedure duration (23%). CONCLUSIONS: Our national survey-based study supports wide adoption of CSP in France. CSP is currently used as a second-line approach for both antibradycardia and resynchronization indications, with important variations regarding implantation techniques and criteria for measuring success.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiologia , Humanos , Volume Sistólico , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia , Função Ventricular Esquerda , Terapia de Ressincronização Cardíaca/efeitos adversos , Resultado do Tratamento
6.
Front Cardiovasc Med ; 9: 998883, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36386348

RESUMO

Background: Myocardial inflammation has been consistently associated with genetic arrhythmogenic cardiomyopathy (ACM) and it has been hypothesized that episodes mimicking acute myocarditis (AM) could represent early inflammatory phases of the disease. Objective: We evaluated the temporal association between recurrent acute myocarditis (RAM) episodes and the later diagnosis of a genetic ACM. Materials and methods: Between January 2012 and December 2021, patients with RAM and no previous cardiomyopathy were included (Recurrent Acute Myocarditis Registry, NCT04589156). A follow-up visit including clinical evaluation, resting and stress electrocardiogram, cardiac magnetic resonance imaging, and genetic testing was carried out. Endpoints of the study was the incidence of both ACM diagnosis criteria and ACM genetic mutation at the end of follow-up. Results: Twenty-one patients with RAM were included and follow-up was completed in 19/21 patients (90%). At the end of follow-up, 3.3 ± 2.9 years after the last AM episode, 14/21 (67%) patients with an ACM phenotype (biventricular: 10/14, 71%; left ventricular: 4/14, 29%) underwent genetic testing. A pathogenic or likely pathogenic mutation was found in 8/14 patients (57%), 5/8 in the Desmoplakin gene, 2/8 in the Plakophillin-2 gene, and 1/8 in the Titin gene. Family history of cardiomyopathy or early sudden cardiac death had a positive predictive value of 88% for the presence of an underlying genetic mutation in patients with RAM. Conclusion: RAM is a rare entity associated with the latter diagnosis of an ACM genetic mutation in more than a third of the cases. In those patients, RAM episodes represent early inflammatory phases of the disease. Including RAM episodes in ACM diagnosis criteria might allow early diagnosis and potential therapeutic interventions.

8.
JACC Clin Electrophysiol ; 8(1): 41-48, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34454885

RESUMO

OBJECTIVES: The aim of this study was to assess the persistence of left atrial (LA) lesions created by ethanol infusion in the vein of Marshall (EIVM) by electroanatomical mapping on repeat catheter ablation for recurrent atrial tachyarrhythmia. BACKGROUND: Little is known about the durability of LA lesions created by EIVM. METHODS: The study included consecutive patients who underwent EIVM for persistent atrial fibrillation or perimitral LA flutter (index procedure) and repeat catheter ablation for recurrent atrial tachyarrhythmia or atrial fibrillation at a single center between January 2019 and April 2020. The acute effect of EIVM was assessed at the index procedure by comparing the area of bipolar voltage <0.05 mV in the vein of Marshall (VOM) region before and immediately after EIVM. The long-term effect of EIVM was assessed by comparing this area in the VOM region between the redo procedure and the index procedure. RESULTS: Twenty-four consecutive patients (mean age 68.6 ± 6.1 years, 58% men) underwent redo procedures after previous EIVM for persistent atrial fibrillation (n = 21 [88%]) or perimitral LA flutter (n = 5 [21%]). In each patient, the EIVM-related lesion persisted, with a chronic scar in the VOM region (median 13.1 cm2 [interquartile range: 8.1-15.9 cm2] vs 12.4 cm2 [interquartile range: 7.6-15.7 cm2] acutely, respectively). One quarter of patients (9 of 20) had late mitral isthmus reconnection, which was located at the mitral annular edge or in the coronary sinus. CONCLUSIONS: Atrial lesions created by EIVM are durable, which reinforces the efficacy profile of EIVM. Reconduction sites in the mitral isthmus are located at the edge of the scar and in the coronary sinus.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Etanol/uso terapêutico , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade
9.
Cells ; 10(3)2021 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-33809210

RESUMO

Aldosterone plays a major role in atrial structural and electrical remodeling, in particular through Ca2+-transient perturbations and shortening of the action potential. The Ca2+-activated non-selective cation channel Transient Receptor Potential Melastatin 4 (TRPM4) participates in atrial action potential. The aim of our study was to elucidate the interactions between aldosterone and TRPM4 in atrial remodeling and arrhythmias susceptibility. Hyperaldosteronemia, combined with a high salt diet, was induced in mice by subcutaneously implanted osmotic pumps during 4 weeks, delivering aldosterone or physiological serum for control animals. The experiments were conducted in wild type animals (Trpm4+/+) as well as Trpm4 knock-out animals (Trpm4-/-). The atrial diameter measured by echocardiography was higher in Trpm4-/- compared to Trpm4+/+ animals, and hyperaldosteronemia-salt produced a dilatation in both groups. Action potentials duration and triggered arrhythmias were measured using intracellular microelectrodes on the isolated left atrium. Hyperaldosteronemia-salt prolong action potential in Trpm4-/- mice but had no effect on Trpm4+/+ mice. In the control group (no aldosterone-salt treatment), no triggered arrythmias were recorded in Trpm4+/+ mice, but a high level was detected in Trpm4-/- mice. Hyperaldosteronemia-salt enhanced the occurrence of arrhythmias (early as well as delayed-afterdepolarization) in Trpm4+/+ mice but decreased it in Trpm4-/- animals. Atrial connexin43 immunolabelling indicated their disorganization at the intercalated disks and a redistribution at the lateral side induced by hyperaldosteronemia-salt but also by Trpm4 disruption. In addition, hyperaldosteronemia-salt produced pronounced atrial endothelial thickening in both groups. Altogether, our results indicated that hyperaldosteronemia-salt and TRPM4 participate in atrial electrical and structural remodeling. It appears that TRPM4 is involved in aldosterone-induced atrial action potential shortening. In addition, TRPM4 may promote aldosterone-induced atrial arrhythmias, however, the underlying mechanisms remain to be explored.


Assuntos
Arritmias Cardíacas/metabolismo , Função do Átrio Esquerdo , Remodelamento Atrial , Átrios do Coração/metabolismo , Frequência Cardíaca , Canais de Cátion TRPM/metabolismo , Potenciais de Ação , Aldosterona , Animais , Arritmias Cardíacas/induzido quimicamente , Arritmias Cardíacas/genética , Arritmias Cardíacas/fisiopatologia , Conexina 43/metabolismo , Modelos Animais de Doenças , Átrios do Coração/fisiopatologia , Masculino , Camundongos Endogâmicos C57BL , Camundongos Knockout , Cloreto de Sódio na Dieta , Canais de Cátion TRPM/genética , Fatores de Tempo
10.
J Cardiovasc Electrophysiol ; 32(2): 545-546, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33058383

RESUMO

The IntellaMap OrionTM (Boston Scientific) is a 64-electrode basket catheter allowing for ultrahigh-density mapping of complex cardiac arrhythmias. We report the case of a basket catheter vascular entrapment, requiring surgical removal.


Assuntos
Flutter Atrial , Ablação por Cateter , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Eletrodos , Desenho de Equipamento , Humanos
11.
J Interv Card Electrophysiol ; 62(2): 347-356, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33128179

RESUMO

PURPOSE: Cardiac resynchronization therapy (CRT) devices have multiple programmable pacing parameters. The purpose of this study was to determine the best pacing mode, i.e., associated with the greatest acute hemodynamic response, in each patient. METHODS: Patients in sinus rhythm and intact atrioventricular conduction were included within 3 months of implantation of devices featuring SyncAV and multipoint pacing (MPP) algorithms. The effect of nominal biventricular pacing using the latest activated electrode (BiV-Late), optimized atrioventricular delay (AVD), nominal and optimized SyncAV, and anatomical MPP was determined by non-invasive measurement of systolic blood pressure (SBP). CRT response was defined as SBP increase > 10% relative to baseline. RESULTS: Thirty patients with left bundle branch block (LBBB) were included. BiV-Late increased SBP compared to intrinsic rhythm (128 ± 21 mmHg vs. 121 ± 22 mmHg, p = 0.0002). The best pacing mode further increased SBP to 140 ± 19 mmHg (p < 0.0001 vs. BiV-Late). The proportion of CRT responders increased from 40% with BiV-Late to 80% with the best pacing mode (p = 0.0005). Compared to BiV-Late, optimized AVD and optimized SyncAV increased SBP (to 134 ± 21 mmHg, p = 0.004, and 133 ± 20 mmHg, p = 0.0003, respectively), but nominal SyncAV and MPP did not. The best pacing mode was variable between patients and was different from nominal BiV-Late in 28 (93%) patients. Optimized AVD was the most frequent best mode, in 14 (47%) patients. CONCLUSION: In patients with LBBB, the best pacing mode was patient-specific and doubled the magnitude of acute hemodynamic response and the proportion of acute CRT responders compared to nominal BiV-Late pacing. TRIAL REGISTRATION: ClinicalTrials.gov : NCT03779802.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Hemodinâmica , Humanos , Resultado do Tratamento
12.
Europace ; 22(11): 1628-1634, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32830226

RESUMO

AIMS: No data exist concerning the clinical performances of the subcutaneous implantable cardioverter-defibrillator (S-ICD) atrial fibrillation (AF) detection algorithm. We aimed to study the performances and implications of the latter in a 'real-world' setting. METHODS AND RESULTS: Between July 2017 and August 2019, 155 consecutive S-ICD recipients were included. Endpoint of the study was the incidence of de novo or recurrent AF using a combined on-site and remote-monitoring follow-up approach. After a mean follow-up of 13 ± 8 months, 2531 AF alerts were generated for 55 patients. A blinded analysis of the 1950 subcutaneous electrocardiograms available was performed. Among them 47% were true AF, 23% were premature atrial contractions or non-sustained AF, 29% were premature ventricular contractions or non-sustained ventricular tachycardia, and 1% were misdetection. Fourteen percent (21/155) patients had at least one correct diagnosis of AF by the S-ICD algorithm. One patient presented symptomatic paroxysmal AF not diagnosed by the S-ICD algorithm (false negative patient). Patient-based sensitivity, specificity, positive, and negative predictive values were respectively 95%, 74%, 38%, and 99%. Among patients with at least one correct diagnosis of AF, 38% (8/21) had subsequent clinical implications (anticoagulation initiation or rhythm control therapies). CONCLUSION: The S-ICD AF detection algorithm yields a high sensitivity for AF diagnosis. Low specificity and positive predictive value contribute to a high remote monitoring-notification workload and underline the necessity of a manual analysis. Atrial fibrillation diagnosis by the S-ICD AF detection algorithm might lead to significant therapeutic adjustments.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Eletrocardiografia , Humanos , Valor Preditivo dos Testes
13.
J Cardiovasc Electrophysiol ; 31(9): 2405-2414, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32562444

RESUMO

INTRODUCTION: In cardiac resynchronization therapy, pacing the left ventricle (LV) at sites of prolonged electrical delay is associated with better outcomes. We sought to characterize the interrelationships between intrinsic, right-ventricular (RV)-paced, and LV-paced interventricular delays. METHODS AND RESULTS: The following electrical timings were measured at implantation for all electrodes of the LV quadripolar leads: QLV, interventricular delay in intrinsic rhythm (RVs-LVs), in RV-paced rhythm (RVp-LVs), and in LV-paced rhythm (LVp-RVs). We included 32 patients (78% men, age 72 years, LV ejection fraction 29%, left bundle branch block 84%). QLV and RVs-LVs were correlated (R2 = .72, p < .0001), as were RVs-LVs and RVp-LVs (R2 = .27, p = .002) and RVp-LVs and LVp-RVs (R2 = .60, p < .001). Direction of activation along the four LV lead electrodes was concordant between RVs-LVs and RVp-LVs in only 17 (53%) patients. The latest-activated electrodes in RVs-LVs and RVp-LVs were concordant in 26 (81%) patients, adjacent in 3 (9%) patients, and remote in 3 (9%) patients. Biventricular-paced QRS duration varied by more than 10 ms between the two electrodes in half of the patients with dissimilar latest electrodes. Among the seven echocardiographic nonresponders at 6 months, the programmed electrode was remote from the latest electrode in RVs-LVs in five patients and in RVp-LVs in three patients. CONCLUSION: Intrinsic and RV-paced interventricular electrical delays are correlated, but there is substantial heterogeneity between patients. The latest-activated electrode may be different between RVs-LVs and RVp-LVs, and this might have important implications in selecting the optimal LV vector.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Idoso , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Masculino , Resultado do Tratamento , Função Ventricular Esquerda
14.
Fundam Clin Pharmacol ; 32(4): 378-391, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29526032

RESUMO

Whether oral anticoagulants, vitamin K antagonists (VKAs), and nonvitamin K oral anticoagulant (NOACs) frequently prescribed to atrial fibrillation (AF) patients, do themselves have a pro- or anti-arrhythmic effect have never been addressed. Transmembrane action potentials were recorded in an acute rabbit model of superfused pulmonary veins (PVs) sleeves preparations using standard microelectrode technique. Fluindione 10 µm (n = 6) increased the AP (action potential) duration (APD), induced a significantly Vmax depression (from 95 ± 14 to 53 ± 5 V/s, P < 0.05), and 2 : 1 blocks during rapid atrial pacing thus evoking class I anti-arrhythmic properties, and prevented spontaneous trigger APs. Apixaban 10 µm (n = 6) increased the APD, significantly prolonged the effective refractory period (from 56.3 ± 4.2 to 72.0 ± 8.6 ms, P < 0.05), and prevented triggered APs occurrence. Fluindione and apixaban effects were suppressed with the addition of the protease-activated receptors 1 (PAR 1) agonist SFLLR-NH2 . Warfarin 10 µm (n = 6) significantly abbreviated the early refractory period (from 56.3 ± 4.2 to 45.0 ± 2.2 ms, P < 0.05) and increased triggered APs occurrence that were successfully prevented by nifedipine but not by the addition of the protease-activated receptors 1 agonist SFLLR-NH2 . In this acute rabbit PVs model, VKAs and NOACs, at physiological concentrations, exhibited very different pharmacological properties that influence PVs electrophysiology, implying PAR1, with fluindione and apixaban which exhibited more anti-arrhythmic properties, whereas warfarin exhibited more pro-arrhythmic properties.


Assuntos
Anticoagulantes/farmacologia , Fenômenos Eletrofisiológicos/efeitos dos fármacos , Veias Pulmonares/efeitos dos fármacos , Receptor PAR-1/metabolismo , Administração Oral , Animais , Antiarrítmicos/farmacologia , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/metabolismo , Feminino , Veias Pulmonares/metabolismo , Pirazóis/farmacologia , Piridonas/farmacologia , Coelhos
15.
Clin Med Insights Cardiol ; 12: 1179546817751628, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29343998

RESUMO

Previous studies showed good agreement between pacemaker respiratory disturbance index (RDI) and polysomnography for diagnosis of severe sleep apnea (SA). The aim of this study is to investigate the diagnostic accuracy of RDI compared with apnea-hypopnea index (AHI) from a cardiorespiratory sleep study for the diagnosis of severe SA within patients requiring a pacemaker and meeting diastolic dysfunction criteria. Secondary objectives are as follows: correlation between plasma aldosterone level and SA severity, diagnostic accuracy of RDI for moderate SA, prevalence of SA among patients with diastolic dysfunction, occurrence of arrhythmias, and improvement of RDI with continuous positive airway pressure therapy. We designed a monocentric prospective nonrandomized study of prevalent cases to include 68 patients with a 6-month follow-up. Both RDI and AHI will be compared 2 months after implantation and after 1 month of continuous positive airway pressure treatment in patients with severe SA. This is the first study that examines diagnostic accuracy of pacemaker algorithm for the diagnosis of SA and correlation with plasma aldosterone levels in patients with diastolic dysfunction. Protocol version: V04. 04/04/2017 Trial registration: ClinicalTrials.gov NCT02751021.

SELEÇÃO DE REFERÊNCIAS