Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Radiol Artif Intell ; 6(4): e230208, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38864742

RESUMO

Purpose To evaluate the reproducibility of radiomics features extracted from T2-weighted MR images in patients with neuroblastoma. Materials and Methods A retrospective study included 419 patients (mean age, 29 months ± 34 [SD]; 220 male, 199 female) with neuroblastic tumors diagnosed between 2002 and 2023, within the scope of the PRedictive In-silico Multiscale Analytics to support cancer personalized diaGnosis and prognosis, Empowered by imaging biomarkers (ie, PRIMAGE) project, involving 746 T2/T2*-weighted MRI sequences at diagnosis and/or after initial chemotherapy. Images underwent processing steps (denoising, inhomogeneity bias field correction, normalization, and resampling). Tumors were automatically segmented, and 107 shape, first-order, and second-order radiomics features were extracted, considered as the reference standard. Subsequently, the previous image processing settings were modified, and volumetric masks were applied. New radiomics features were extracted and compared with the reference standard. Reproducibility was assessed using the concordance correlation coefficient (CCC); intrasubject repeatability was measured using the coefficient of variation (CoV). Results When normalization was omitted, only 5% of the radiomics features demonstrated high reproducibility. Statistical analysis revealed significant changes in the normalization and resampling processes (P < .001). Inhomogeneities removal had the least impact on radiomics (83% of parameters remained stable). Shape features remained stable after mask modifications, with a CCC greater than 0.90. Mask modifications were the most favorable changes for achieving high CCC values, with a radiomics features stability of 70%. Only 7% of second-order radiomics features showed an excellent CoV of less than 0.10. Conclusion Modifications in the T2-weighted MRI preparation process in patients with neuroblastoma resulted in changes in radiomics features, with normalization identified as the most influential factor for reproducibility. Inhomogeneities removal had the least impact on radiomics features. Keywords: Pediatrics, MR Imaging, Oncology, Radiomics, Reproducibility, Repeatability, Neuroblastic Tumors Supplemental material is available for this article. © RSNA, 2024 See also the commentary by Safdar and Galaria in this issue.


Assuntos
Imageamento por Ressonância Magnética , Neuroblastoma , Humanos , Neuroblastoma/diagnóstico por imagem , Neuroblastoma/patologia , Masculino , Feminino , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Pré-Escolar , Criança , Lactente , Interpretação de Imagem Assistida por Computador/métodos , Radiômica
2.
Pediatr Radiol ; 54(4): 562-570, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37747582

RESUMO

This review paper presents the practical development of imaging biomarkers in the scope of the PRIMAGE (PRedictive In silico Multiscale Analytics to support cancer personalized diaGnosis and prognosis, Empowered by imaging biomarkers) project, as a noninvasive and reliable way to improve the diagnosis and prognosis in pediatric oncology. The PRIMAGE project is a European multi-center research initiative that focuses on developing medical imaging-derived artificial intelligence (AI) solutions designed to enhance overall management and decision-making for two types of pediatric cancer: neuroblastoma and diffuse intrinsic pontine glioma. To allow this, the PRIMAGE project has created an open-cloud platform that combines imaging, clinical, and molecular data together with AI models developed from this data, creating a comprehensive decision support environment for clinicians managing patients with these two cancers. In order to achieve this, a standardized data processing and analysis workflow was implemented to generate robust and reliable predictions for different clinical endpoints. Magnetic resonance (MR) image harmonization and registration was performed as part of the workflow. Subsequently, an automated tool for the detection and segmentation of tumors was trained and internally validated. The Dice similarity coefficient obtained for the independent validation dataset was 0.997, indicating compatibility with the manual segmentation variability. Following this, radiomics and deep features were extracted and correlated with clinical endpoints. Finally, reproducible and relevant imaging quantitative features were integrated with clinical and molecular data to enrich both the predictive models and a set of visual analytics tools, making the PRIMAGE platform a complete clinical decision aid system. In order to ensure the advancement of research in this field and to foster engagement with the wider research community, the PRIMAGE data repository and platform are currently being integrated into the European Federation for Cancer Images (EUCAIM), which is the largest European cancer imaging research infrastructure created to date.


Assuntos
Inteligência Artificial , Neoplasias , Criança , Humanos , Radiômica , Prognóstico , Neoplasias/diagnóstico por imagem , Biomarcadores
3.
Phys Med ; 114: 103153, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37778209

RESUMO

PURPOSE: To develop a QA procedure, easy to use, reproducible and based on open-source code, to automatically evaluate the stability of different metrics extracted from CT images: Hounsfield Unit (HU) calibration, edge characterization metrics (contrast and drop range) and radiomic features. METHODS: The QA protocol was based on electron density phantom imaging. Home-made open-source Python code was developed for the automatic computation of the metrics and their reproducibility analysis. The impact on reproducibility was evaluated for different radiation therapy protocols, and phantom positions within the field of view and systems, in terms of variability (Shapiro-Wilk test for 15 repeated measurements carried out over three days) and comparability (Bland-Altman analysis and Wilcoxon Rank Sum Test or Kendall Rank Correlation Coefficient). RESULTS: Regarding intrinsic variability, most metrics followed a normal distribution (88% of HU, 63% of edge parameters and 82% of radiomic features). Regarding comparability, HU and contrast were comparable in all conditions, and drop range only in the same CT scanner and phantom position. The percentages of comparable radiomic features independent of protocol, position and system were 59%, 78% and 54%, respectively. The non-significantly differences in HU calibration curves obtained for two different institutions (7%) translated in comparable Gamma Index G (1 mm, 1%, >99%). CONCLUSIONS: An automated software to assess the reproducibility of different CT metrics was successfully created and validated. A QA routine proposal is suggested.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X , Calibragem , Reprodutibilidade dos Testes , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Software
4.
Front Endocrinol (Lausanne) ; 14: 1213441, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37600695

RESUMO

Objective: To assess the prevalence of pancreatic steatosis and iron overload in non-alcoholic fatty liver disease (NAFLD) and their correlation with liver histology severity and the risk of cardiometabolic diseases. Method: A prospective, multicenter study including NAFLD patients with biopsy and paired Magnetic Resonance Imaging (MRI) was performed. Liver biopsies were evaluated according to NASH Clinical Research Network, hepatic iron storages were scored, and digital pathology quantified the tissue proportionate areas of fat and iron. MRI-biomarkers of fat fraction (PDFF) and iron accumulation (R2*) were obtained from the liver and pancreas. Different metabolic traits were evaluated, cardiovascular disease (CVD) risk was estimated with the atherosclerotic CVD score, and the severity of iron metabolism alteration was determined by grading metabolic hiperferritinemia (MHF). Associations between CVD, histology and MRI were investigated. Results: In total, 324 patients were included. MRI-determined pancreatic iron overload and moderate-to severe steatosis were present in 45% and 25%, respectively. Liver and pancreatic MRI-biomarkers showed a weak correlation (r=0.32 for PDFF, r=0.17 for R2*). Pancreatic PDFF increased with hepatic histologic steatosis grades and NASH diagnosis (p<0.001). Prevalence of pancreatic steatosis and iron overload increased with the number of metabolic traits (p<0.001). Liver R2* significantly correlated with MHF (AUC=0.77 [0.72-0.82]). MRI-determined pancreatic steatosis (OR=3.15 [1.63-6.09]), and iron overload (OR=2.39 [1.32-4.37]) were independently associated with high-risk CVD. Histologic diagnosis of NASH and advanced fibrosis were also associated with high-risk CVD. Conclusion: Pancreatic steatosis and iron overload could be of utility in clinical decision-making and prognostication of NAFLD.


Assuntos
Doenças Cardiovasculares , Sobrecarga de Ferro , Transtornos do Metabolismo dos Lipídeos , Hepatopatia Gordurosa não Alcoólica , Pancreatopatias , Humanos , Hepatopatia Gordurosa não Alcoólica/complicações , Hepatopatia Gordurosa não Alcoólica/epidemiologia , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/etiologia , Estudos Prospectivos , Fatores de Risco , Pancreatopatias/complicações , Pancreatopatias/diagnóstico por imagem , Sobrecarga de Ferro/complicações , Ferro , Fatores de Risco de Doenças Cardíacas
5.
Cancers (Basel) ; 15(5)2023 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-36900410

RESUMO

OBJECTIVES: To externally validate and assess the accuracy of a previously trained fully automatic nnU-Net CNN algorithm to identify and segment primary neuroblastoma tumors in MR images in a large children cohort. METHODS: An international multicenter, multivendor imaging repository of patients with neuroblastic tumors was used to validate the performance of a trained Machine Learning (ML) tool to identify and delineate primary neuroblastoma tumors. The dataset was heterogeneous and completely independent from the one used to train and tune the model, consisting of 300 children with neuroblastic tumors having 535 MR T2-weighted sequences (486 sequences at diagnosis and 49 after finalization of the first phase of chemotherapy). The automatic segmentation algorithm was based on a nnU-Net architecture developed within the PRIMAGE project. For comparison, the segmentation masks were manually edited by an expert radiologist, and the time for the manual editing was recorded. Different overlaps and spatial metrics were calculated to compare both masks. RESULTS: The median Dice Similarity Coefficient (DSC) was high 0.997; 0.944-1.000 (median; Q1-Q3). In 18 MR sequences (6%), the net was not able neither to identify nor segment the tumor. No differences were found regarding the MR magnetic field, type of T2 sequence, or tumor location. No significant differences in the performance of the net were found in patients with an MR performed after chemotherapy. The time for visual inspection of the generated masks was 7.9 ± 7.5 (mean ± Standard Deviation (SD)) seconds. Those cases where manual editing was needed (136 masks) required 124 ± 120 s. CONCLUSIONS: The automatic CNN was able to locate and segment the primary tumor on the T2-weighted images in 94% of cases. There was an extremely high agreement between the automatic tool and the manually edited masks. This is the first study to validate an automatic segmentation model for neuroblastic tumor identification and segmentation with body MR images. The semi-automatic approach with minor manual editing of the deep learning segmentation increases the radiologist's confidence in the solution with a minor workload for the radiologist.

6.
Biomolecules ; 11(12)2021 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-34944452

RESUMO

Traditional histological evaluation for grading liver disease severity is based on subjective and semi-quantitative scores. We examined the relationship between digital pathology analysis and corresponding scoring systems for the assessment of hepatic necroinflammatory activity. A prospective, multicenter study including 156 patients with chronic liver disease (74% nonalcoholic fatty liver disease-NAFLD, 26% chronic hepatitis-CH etiologies) was performed. Inflammation was graded according to the Nonalcoholic Steatohepatitis (NASH) Clinical Research Network system and METAVIR score. Whole-slide digital image analysis based on quantitative (I-score: inflammation ratio) and morphometric (C-score: proportionate area of staining intensities clusters) measurements were independently performed. Our data show that I-scores and C-scores increase with inflammation grades (p < 0.001). High correlation was seen for CH (ρ = 0.85-0.88), but only moderate for NAFLD (ρ = 0.5-0.53). I-score (p = 0.008) and C-score (p = 0.002) were higher for CH than NAFLD. Our MATLAB algorithm performed better than QuPath software for the diagnosis of low-moderate inflammation (p < 0.05). C-score AUC for classifying NASH was 0.75 (95%CI, 0.65-0.84) and for moderate/severe CH was 0.99 (95%CI, 0.97-1.00). Digital pathology measurements increased with fibrosis stages (p < 0.001). In conclusion, quantitative and morphometric metrics of inflammatory burden obtained by digital pathology correlate well with pathologists' scores, showing a higher accuracy for the evaluation of CH than NAFLD.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Fibrose , Humanos , Fígado , Cirrose Hepática , Masculino , Pessoa de Meia-Idade
7.
J Digit Imaging ; 34(5): 1134-1145, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34505958

RESUMO

Several noise sources, such as the Johnson-Nyquist noise, affect MR images disturbing the visualization of structures and affecting the subsequent extraction of radiomic data. We evaluate the performance of 5 denoising filters (anisotropic diffusion filter (ADF), curvature flow filter (CFF), Gaussian filter (GF), non-local means filter (NLMF), and unbiased non-local means (UNLMF)), with 33 different settings, in T2-weighted MR images of phantoms (N = 112) and neuroblastoma patients (N = 25). Filters were discarded until the most optimal solutions were obtained according to 3 image quality metrics: peak signal-to-noise ratio (PSNR), edge-strength similarity-based image quality metric (ESSIM), and noise (standard deviation of the signal intensity of a region in the background area). The selected filters were ADFs and UNLMs. From them, 107 radiomics features preservation at 4 progressively added noise levels were studied. The ADF with a conductance of 1 and 2 iterations standardized the radiomic features, improving reproducibility and quality metrics.


Assuntos
Algoritmos , Diagnóstico por Imagem , Biomarcadores , Humanos , Reprodutibilidade dos Testes , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...