Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Clin Med ; 12(4)2023 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-36835885

RESUMO

COVID-19 acute respiratory distress syndrome (ARDS) can be associated with extensive lung damage, pneumothorax, pneumomediastinum and, in severe cases, persistent air leaks (PALs) via bronchopleural fistulae (BPF). PALs can impede weaning from invasive ventilation or extracorporeal membrane oxygenation (ECMO). We present a series of patients requiring veno-venous ECMO for COVID-19 ARDS who underwent endobronchial valve (EBV) management of PAL. This is a single-centre retrospective observational study. Data were collated from electronic health records. Patients treated with EBV met the following criteria: ECMO for COVID-19 ARDS; the presence of BPF causing PAL; air leak refractory to conventional management preventing ECMO and ventilator weaning. Between March 2020 and March 2022, 10 out of 152 patients requiring ECMO for COVID-19 developed refractory PALs, which were successfully treated with bronchoscopic EBV placement. The mean age was 38.3 years, 60% were male, and half had no prior co-morbidities. The average duration of air leaks prior to EBV deployment was 18 days. EBV placement resulted in the immediate cessation of air leaks in all patients with no peri-procedural complications. Weaning of ECMO, successful ventilator recruitment and removal of pleural drains were subsequently possible. A total of 80% of patients survived to hospital discharge and follow-up. Two patients died from multi-organ failure unrelated to EBV use. This case series presents the feasibility of EBV placement in severe parenchymal lung disease with PAL in patients requiring ECMO for COVID-19 ARDS and its potential to expedite weaning from both ECMO and mechanical ventilation, recovery from respiratory failure and ICU/hospital discharge.

3.
Clin Med (Lond) ; 19(4): 331-333, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31308116

RESUMO

Oesophago-pericardial fistula following any electrophysiological procedure is a rare, and potentially, life-threatening condition. Initial presentation can easily be misdiagnosed, as symptoms vary and are not specific. Echocardiography is an invaluable tool to diagnose and rule out complications. We present the case of a 68-year-old patient who developed an oesophago-pericardial fistula complicated with purulent pericarditis, sepsis and cerebral air embolism. In conclusion, this case report encourages physicians to use strategies that may help with early diagnosis and lead to potential lifesaving interventions.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Embolia Aérea , Fístula Esofágica , Embolia Intracraniana , Ecocardiografia , Embolia Aérea/diagnóstico por imagem , Embolia Aérea/etiologia , Embolia Aérea/patologia , Fístula Esofágica/diagnóstico por imagem , Fístula Esofágica/etiologia , Fístula Esofágica/patologia , Humanos , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/etiologia , Embolia Intracraniana/patologia , Masculino , Pessoa de Meia-Idade , Pericárdio/diagnóstico por imagem , Pericárdio/patologia
4.
Am J Cardiol ; 113(8): 1312-9, 2014 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-24685325

RESUMO

In light of the low cost, the widespread availability of the electrocardiogram, and the increasing economic burden of the health-related problems, we aimed to analyze the prognostic value of automatic frontal QRS-T angle to predict mortality in patients with left ventricular (LV) systolic dysfunction after acute myocardial infarction (AMI). About 467 consecutive patients discharged with diagnosis of AMI and with LV ejection fraction ≤40% were followed during 3.9 years (2.1 to 5.9). From them, 217 patients (47.5%) died. The frontal QRS-T angle was higher in patients who died (116.6±52.8 vs 77.9±55.1, respectively, p<0.001). The QRS-T angle value of 90° was the most accurate to predict all-cause cardiac death. After multivariate analysis, frontal QRS-T angle remained as an excellent predictor of all-cause and cardiac deaths, increasing the mortality 6% per each 10°. For the global mortality, the hazard ratio for a QRS-T angle>90° was 2.180 (1.558 to 3.050), and for the combined end point of cardiac death and appropriate implantable cardioverter defribrillator therapy, it was 2.385 (1.570 to 3.623). This independent predictive value was maintained even after adjusting by bundle brunch block, ST-elevation AMI, and its localization. In conclusion, a wide automatic frontal QRS-T angle (>90°) is a good discriminator of long-term mortality in patients with LV systolic dysfunction after an AMI. The ability to easily measure it from a standard 12-lead electrocardiogram together with its prognostic value makes the frontal QRS-T angle an attractive tool to help clinicians to improve risk stratification of those patients.


Assuntos
Eletrocardiografia , Infarto do Miocárdio/diagnóstico , Medição de Risco/métodos , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/diagnóstico , Função Ventricular Esquerda/fisiologia , Idoso , Causas de Morte/tendências , Feminino , Seguimentos , Humanos , Masculino , Infarto do Miocárdio/complicações , Infarto do Miocárdio/mortalidade , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Espanha/epidemiologia , Taxa de Sobrevida/tendências , Fatores de Tempo , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...