BMC Anesthesiol ; 13(1): 20, 2013 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-24020798

RESUMO

BACKGROUND: In a smaller experience, the authors previously demonstrated that end-tidal carbon dioxide (PetCO2) and cardiac output (CO) had a positive association in emergently intubated trauma patients during Emergency Department resuscitation. The aim of this larger study was to reassess the relationship of PetCO2 with CO and identify patient risk-conditions influencing PetCO2 and CO values. METHODS: The investigation consists of acutely injured trauma patients requiring emergency tracheal intubation. The study focuses on the prospective collection of PetCO2 and noninvasive CO monitor (NICOM®) values in the Emergency Department. RESULTS: From the end of March through August 2011, 73 patients had 318 pairs of PetCO2 (mm Hg) and CO (L/min.) values. Mean data included Injury Severity Score (ISS) ≥15 in 65.2%, Glasgow Coma Score of 6.4 ± 4.6, hypotension in 19.0%, and death in 34.3%. With PetCO2 ≤ 25 (15.9 ± 8.0), systolic blood pressure was 77.0 ± 69, CO was 3.2 ± 3.0, cardiac arrest was 60.4%, and mortality was 84.9%. During hypotension, CO was lower with major blood loss (1.9), than without major loss (5.0; P = 0.0008). Low PetCO2 was associated with low CO (P < 0.0001). Low PetCO2 was associated (P ≤ 0.0012) with ISS > 20, hypotension, bradycardia, major blood loss, abnormal pupils, cardiac arrest, and death. Low CO was associated (P ≤ 0.0059) with ISS > 20, hypotension, bradycardia, major blood loss, abnormal pupils, cardiac arrest, and death. CONCLUSIONS: During emergency department resuscitation, a decline in PetCO2 correlates with decreases in noninvasive CO in emergently intubated trauma patients. Decreasing PetCO2 and declining NICOM CO are associated with hemodynamic instability, hemorrhage, abnormal pupils, and death. The study indicates that NICOM CO values are clinically discriminate and have physiologic validity.

2.
Ann Plast Surg ; 70(3): 335-6, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22395048

RESUMO

Vaginal reconstructive options commonly include the use of split-thickness skin grafts or intestinal conduits. When a colonic segment is chosen, the sigmoid colon is favored because of its location, size, and durability. When circumstances preclude the use of sigmoid colon and a colonic conduit is preferred, creative means of mobilization are required. This article describes a case and technique utilizing the descending colon in a tension-free vaginoplasty.


Assuntos
Adenocarcinoma/cirurgia , Colo Sigmoide/transplante , Recidiva Local de Neoplasia/cirurgia , Exenteração Pélvica/efeitos adversos , Procedimentos de Cirurgia Plástica/métodos , Vagina/cirurgia , Neoplasias Vaginais/cirurgia , Colo Sigmoide/irrigação sanguínea , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasias Ovarianas/cirurgia , Retalhos Cirúrgicos/irrigação sanguínea , Neoplasias Uterinas/cirurgia
3.
J Trauma Acute Care Surg ; 73(2): 479-85, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23019674

RESUMO

BACKGROUND: Anoninvasive cardiac output (CO) monitor (NICOM), using Bioreactance technology, has been validated in several nontrauma patient studies. We hypothesized that NICOM CO would have more significant associations with clinical conditions than would systolic blood pressure (sBP). METHODS: This is a prospective observational study of consecutive trauma activation patients during the first 10 to 60 minutes after emergency department arrival. RESULTS: Analysis includes 270 consecutive trauma activation patients with 1,568 observations. CO was decreased (p ≤ 0.002) with major blood loss, hypotension, red blood cell transfusion, Injury Severity Score (ISS) higher than 20, low PetCO2, abnormal pupils, elderly, preexisting conditions, low body surface area level, females, hypothermia, and death. CO was increased (p < 0.0001) with base deficit, ethanol positivity, and illicit drug positivity. The sBP was decreased (p ≤ 0.0005) with major blood loss, red blood cell transfusion, low PetCO2, low body surface area level, and illicit drug positivity. The sBP was increased (p e 0.01) with ISS higher than 20, elderly, and preexisting conditions. Total significant condition associations were CO 83% (15 of 18 patients) and sBP 47% (8 of 17 patients; p = 0.03). In hypotensive patients, CO was lower with major blood loss (3.3 ± 2.1 L/ min) than without (6.0 ± 2.2 L/min; p < 0.0001). Of survivors with ISS 15 or higher, NICOM patients experienced a shorter hospital length of stay (10.5 days) when compared with 2009 and 2010 patients (14.0 days; p = 0.03). CONCLUSION: The multiple associations of CO with patient conditions imply that NICOM provides an objective and clinically valid, relevant, and discriminate measure of cardiac function in acutely injured trauma activation patients. NICOM use may be associated with a shorter length of stay in surviving patients with complex injuries.


Assuntos
Débito Cardíaco/fisiologia , Serviço Hospitalar de Emergência , Mortalidade Hospitalar/tendências , Monitorização Fisiológica/instrumentação , Ferimentos e Lesões/diagnóstico , Ferimentos e Lesões/mortalidade , Adulto , Fatores Etários , Idoso , Pressão Sanguínea , Débito Cardíaco Elevado/diagnóstico , Débito Cardíaco Elevado/mortalidade , Baixo Débito Cardíaco/diagnóstico , Baixo Débito Cardíaco/mortalidade , Causas de Morte , Estudos de Coortes , Comorbidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Medição de Risco , Análise de Sobrevida , Fatores de Tempo , Centros de Traumatologia , Índices de Gravidade do Trauma , Triagem , Ferimentos e Lesões/terapia
4.
Ann Plast Surg ; 66(4): 403-9, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21042180

RESUMO

Biologic prostheses have emerged to address the limitations of synthetic materials for ventral hernia repairs; however, they lack experimental comparative data. Fifteen swine were randomly assigned to 1 of 3 bioprosthetic groups (DermaMatrix, AlloDerm, and Permacol) after creation of a full thickness ventral fascial defect. At 15 weeks, host incorporation, hernia recurrence, adhesion formation, neovascularization, inflammation, and biomechanical properties were assessed. No animals had hernia recurrence or eventration. DermaMatrix and Alloderm implants demonstrated more adhesions, greater inflammatory infiltration, and more longitudinal laxity, but near identical neovascularization and tensile strength to Permacol. We found that porcine acellular dermal products (Permacol) contain following essential properties of an ideal ventral hernia repair material: low inflammation, less elastin and stretch, lower adhesion rates and cost, and more contracture. The addition of lower cost xenogeneic acellular dermal products to the repertoire of available acellular dermal products demonstrates promise, but requires long-term clinical studies to verify advantages and efficacy.


Assuntos
Materiais Biocompatíveis/uso terapêutico , Bioprótese , Colágeno/administração & dosagem , Colágeno/uso terapêutico , Hérnia Ventral/cirurgia , Pele Artificial , Telas Cirúrgicas , Animais , Modelos Animais , Procedimentos Cirúrgicos Operatórios/métodos , Técnicas de Sutura , Suínos , Resultado do Tratamento