Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Micromachines (Basel) ; 15(5)2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38793206

RESUMO

We studied the effects of vertical vibrations on a water drop that was pinned to the sharp edges of a rectangular post. By varying the frequency and amplitude of the vertical displacement, distinct resonance peaks were observed using a simple optical technique. The vibrational spectra of the first two modes exhibited two closely spaced peaks, which corresponded to standing waves that exist along the major and minor contour lengths of the drops. The values of the resonance frequencies can be explained rather well by a simple model, which was originally proposed for axially symmetric drops.

2.
ACS Appl Mater Interfaces ; 16(3): 4271-4282, 2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38194671

RESUMO

Controlled splitting of liquid droplets is a key function in many microfluidic applications. In recent years, various methodologies have been used to accomplish this task. Here, we present an optofluidic technique based on an engineered surface formed by coating a z-cut iron-doped lithium niobate crystal with a lubricant-infused layer, which provides a very slippery surface. Illuminating the crystal with a light spot induces surface charges of opposite signs on the two crystal faces because of the photovoltaic effect. If the light spot is sufficiently intense, millimetric water droplets placed near the illuminated spot split into two charged fragments, one fragment being trapped by the bright spot and the other moving away from it. The latter fragment does not move randomly but rather follows one of three well-defined trajectories separated by 120°, which reflect the anisotropic crystalline structure of Fe:LiNbO3. Numerical simulations explain the behavior of water droplets in the framework of the forces induced by the interplay of pyroelectric, piezoelectric, and photovoltaic effects, which originate simultaneously inside the illuminated crystal. Such a synergetic effect can provide a valuable feature in applications that require splitting and coalescence of droplets, such as chemical microreactors and biological encapsulation and screening.

3.
Sensors (Basel) ; 23(12)2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37420565

RESUMO

Magnetic beads (or particles) having a size between 1 and 5 µm are largely used in many biochemical assays devoted to both purification and quantification of cells, nucleic acids, or proteins. Unfortunately, the use of these beads within microfluidic devices suffers from natural precipitation because of their size and density. The strategies applied thus far to cells or polymeric particles cannot be extended to magnetic beads, mainly due to their magnetization and their higher densities. We report an effective shaking device capable of preventing the sedimentation of beads that are stored in a custom PCR tube. After the characterization of the operating principle, the device is validated for magnetic beads in droplets, leading to an equal distribution between the droplets, barely affecting their generation.


Assuntos
Técnicas Analíticas Microfluídicas , Ácidos Nucleicos , Microfluídica , Campos Magnéticos , Dispositivos Lab-On-A-Chip
4.
J Colloid Interface Sci ; 644: 487-495, 2023 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-37146485

RESUMO

HYPOTHESIS: Droplets of yield stress fluids (YSFs), i.e. fluids that can flow only if they are subjected to a stress above a critical value and otherwise deform like solids, hardly move on solid surfaces due to their high viscosity. The use of highly slippery lubricated surfaces can shed light on the mobility of YSF droplets, which include everyday soft materials, such as toothpaste or mayonnaise, and biological fluids, such as mucus. EXPERIMENTS: The spreading and mobility of droplets of aqueous solutions of swollen Carbopol microgels were studied on lubricant infused surfaces. These solutions represent a model system of YSFs. Dynamical phase diagrams were established by varying the concentration of the solutions and the inclination angle of the surfaces. FINDINGS: Carbopol droplets deposited on lubricated surfaces could move even at low inclination angles. The droplets were found to slide because of the slip of the flowing oil that covered the solid substrate. However, as the descending speed increased, the droplets rolled down. Rolling was favored at high inclinations and low concentrations. A simple criterion based on the ratio between the yield stress of the Carbopol suspensions and the gravitational stress acting on the Carbopol droplets was found to nicely identify the transition between the two regimes.

5.
Sensors (Basel) ; 23(9)2023 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-37177725

RESUMO

Recent years have witnessed relevant advancements in the quality of life of persons with lower limb amputations thanks to the technological developments in prosthetics. However, prostheses that provide information about the foot-ground interaction, and in particular about terrain irregularities, are still missing on the market. The lack of tactile feedback from the foot sole might lead subjects to step on uneven terrains, causing an increase in the risk of falling. To address this issue, a biomimetic vibrotactile feedback system that conveys information about gait and terrain features sensed by a dedicated insole has been assessed with intact subjects. After having shortly experienced both even and uneven terrains, the recruited subjects discriminated them with an accuracy of 87.5%, solely relying on the replay of the vibrotactile feedback. With the objective of exploring the human decoding mechanism of the feedback startegy, a KNN classifier was trained to recognize the uneven terrains. The outcome suggested that the subjects achieved such performance with a temporal dynamics of 45 ms. This work is a leap forward to assist lower-limb amputees to appreciate the floor conditions while walking, adapt their gait and promote a more confident use of their artificial limb.


Assuntos
Amputados , Membros Artificiais , Humanos , Retroalimentação , Tecnologia Háptica , Qualidade de Vida , Extremidade Inferior , , Caminhada , Marcha , Fenômenos Biomecânicos
6.
Lab Chip ; 23(6): 1713, 2023 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-36852524

RESUMO

Correction for 'Developing an advanced gut on chip model enabling the study of epithelial cell/fibroblast interactions' by Marine Verhulsel et al., Lab Chip, 2021, 21, 365-377, https://doi.org/10.1039/d0lc00672f.

7.
Artif Intell Med ; 130: 102328, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35809967

RESUMO

The continuous monitoring of an individual's breathing can be an instrument for the assessment and enhancement of human wellness. Specific respiratory features are unique markers of the deterioration of a health condition, the onset of a disease, fatigue and stressful circumstances. The early and reliable prediction of high-risk situations can result in the implementation of appropriate intervention strategies that might be lifesaving. Hence, smart wearables for the monitoring of continuous breathing have recently been attracting the interest of many researchers and companies. However, most of the existing approaches do not provide comprehensive respiratory information. For this reason, a meta-learning algorithm based on LSTM neural networks for inferring the respiratory flow from a wearable system embedding FBG sensors and inertial units is herein proposed. Different conventional machine learning approaches were implemented as well to ultimately compare the results. The meta-learning algorithm turned out to be the most accurate in predicting respiratory flow when new subjects are considered. Furthermore, the LSTM model memory capability has been proven to be advantageous for capturing relevant aspects of the breathing pattern. The algorithms were tested under different conditions, both static and dynamic, and with more unobtrusive device configurations. The meta-learning results demonstrated that a short one-time calibration may provide subject-specific models which predict the respiratory flow with high accuracy, even when the number of sensors is reduced. Flow RMS errors on the test set ranged from 22.03 L/min, when the minimum number of sensors was considered, to 9.97 L/min for the complete setting (target flow range: 69.231 ± 21.477 L/min). The correlation coefficient r between the target and the predicted flow changed accordingly, being higher (r = 0.9) for the most comprehensive and heterogeneous wearable device configuration. Similar results were achieved even with simpler settings which included the thoracic sensors (r ranging from 0.84 to 0.88; test flow RMSE = 10.99 L/min, when exclusively using the thoracic FBGs). The further estimation of respiratory parameters, i.e., rate and volume, with low errors across different breathing behaviors and postures proved the potential of such approach. These findings lay the foundation for the implementation of reliable custom solutions and more sophisticated artificial intelligence-based algorithms for daily life health-related applications.


Assuntos
Inteligência Artificial , Dispositivos Eletrônicos Vestíveis , Algoritmos , Humanos , Aprendizado de Máquina , Respiração
8.
Micromachines (Basel) ; 13(2)2022 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-35208440

RESUMO

The actuation of droplets on a surface is extremely relevant for microfluidic applications. In recent years, various methodologies have been used. A promising solution relies on iron-doped lithium niobate crystals that, when illuminated, generate an evanescent electric field in the surrounding space due to the photovoltaic effect. This field can be successfully exploited to control the motion of water droplets. Here, we present an experimental method to determine the attractive force exerted by the evanescent field. It consists of the analysis of the elongation of a pendant droplet and its detachment from the suspending syringe needle, caused by the illumination of an iron-doped lithium niobate crystal. We show that this interaction resembles that obtained by applying a voltage between the needle and a metallic substrate, and a quantitative investigation of these two types of actuation yields similar results. Pendant droplet tensiometry is then demonstrated to offer a simple solution for quickly mapping out the force at different distances from the crystal, generated by the photovoltaic effect and its temporal evolution, providing important quantitative data for the design and characterization of optofluidic devices based on lithium niobate crystals.

9.
Biosensors (Basel) ; 13(1)2022 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-36671885

RESUMO

Extracellular vesicles (EVs) are double-layered lipid membrane vesicles released by cells. Currently, EVs are attracting a lot of attention in the biological and medical fields due to their role as natural carriers of proteins, lipids, and nucleic acids. Thus, they can transport useful genomic information from their parental cell through body fluids, promoting cell-to-cell communication even between different organs. Due to their functionality as cargo carriers and their protein expression, they can play an important role as possible diagnostic and prognostic biomarkers in various types of diseases, e.g., cancers, neurodegenerative, and autoimmune diseases. Today, given the invaluable importance of EVs, there are some pivotal challenges to overcome in terms of their isolation. Conventional methods have some limitations: they are influenced by the starting sample, might present low throughput and low purity, and sometimes a lack of reproducibility, being operator dependent. During the past few years, several microfluidic approaches have been proposed to address these issues. In this review, we summarize the most important microfluidic-based devices for EV isolation, highlighting their advantages and disadvantages compared to existing technology, as well as the current state of the art from the perspective of the use of these devices in clinical applications.


Assuntos
Vesículas Extracelulares , Ácidos Nucleicos , Microfluídica , Reprodutibilidade dos Testes , Vesículas Extracelulares/metabolismo , Comunicação Celular
10.
ACS Appl Mater Interfaces ; 13(29): 34752-34761, 2021 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-34256559

RESUMO

Surface-enhanced Raman scattering (SERS) is an ideal technique for environmental and biomedical sensor devices due to not only the highly informative vibrational features but also to its ultrasensitive nature and possibilities toward quantitative assays. Moreover, in these areas, SERS is especially useful as water hinders most of the spectroscopic techniques such as those based on IR absorption. Despite its promising possibilities, most SERS substrates and technological frameworks for SERS detection are still restricted to research laboratories, mainly due to a lack of robust technologies and standardized protocols. We present herein the implementation of Janus magnetic/plasmonic Fe3O4/Au nanostars (JMNSs) as SERS colloidal substrates for the quantitative determination of several analytes. This multifunctional substrate enables the application of an external magnetic field for JMNSs retention at a specific position within a microfluidic channel, leading to additional amplification of the SERS signals. A microfluidic device was devised and 3D printed as a demonstration of cheap and fast production, with the potential for large-scale implementation. As low as 100 µL of sample was sufficient to obtain results in 30 min, and the chip could be reused for several cycles. To show the potential and versatility of the sensing system, JMNSs were exploited with the microfluidic device for the detection of several relevant analytes showing increasing analytical difficulty, including the comparative detection of p-mercaptobenzoic acid and crystal violet and the quantitative detection of the herbicide flumioxazin and the anticancer drug erlotinib in plasma, where calibration curves within diagnostic concentration intervals were obtained.


Assuntos
Benzoatos/análise , Benzoxazinas/análise , Cloridrato de Erlotinib/sangue , Violeta Genciana/análise , Nanopartículas de Magnetita/química , Ftalimidas/análise , Compostos de Sulfidrila/análise , Antineoplásicos/sangue , Ouro/química , Herbicidas/análise , Humanos , Dispositivos Lab-On-A-Chip , Limite de Detecção , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Impressão Tridimensional , Análise Espectral Raman/instrumentação , Análise Espectral Raman/métodos
11.
Lab Chip ; 21(2): 365-377, 2021 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-33306083

RESUMO

Organoids are widely used as a model system to study gut pathophysiology; however, they fail to fully reproduce the complex, multi-component structure of the intestinal wall. We present here a new gut on chip model that allows the co-culture of primary epithelial and stromal cells. The device has the topography and dimensions of the mouse gut and is based on a 3D collagen I scaffold. The scaffold is coated with a thin layer of laminin to mimic the basement membrane. To maintain the scaffold structure while preserving its cytocompatibility, the collagen scaffold was rigidified by threose-based post-polymerization treatment. This treatment being cytocompatible enabled the incorporation of primary intestinal fibroblasts inside the scaffold, reproducing the gut stromal compartment. We observed that mouse organoids, when deposited into crypts, opened up and epithelialized the scaffold, generating a polarized epithelial monolayer. Proper segregation of dividing and differentiated cells along the crypt-villus axis was achieved under these conditions. Finally, we show that the application of fluid shear stress allows the long-term culture of this intestinal epithelium. Our device represents a new biomimetic tool that captures key features of the gut complexity and could be used to study gut pathophysiology.


Assuntos
Mucosa Intestinal , Intestinos , Animais , Comunicação Celular , Células Epiteliais , Fibroblastos , Camundongos
12.
Parasitol Int ; 80: 102207, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33059116

RESUMO

The genus Giardia includes several species distinguished by morphological, biological and molecular features. Currently, eight species within the genus are retained as valid. In Italy no identification of Giardia species other than Giardia duodenalis has been so far reported. Fecal samples were collected from two Günther's Voles (Microtus guentheri) positive to Giardia cysts by microscopic investigation and immunofluorescence. The voles were born in Milan (Northern Italy) from two gravid females imported from the Netherlands and kept for sale in a pet shop in Varese (Northern Italy). Positive feces were subjected to a nested PCR to amplify a 18S rRNA fragment for molecular characterization. A phylogenetic analysis was conducted to compare the obtained sequence with those of all other Giardia species available in GenBank for the 18S locus, using the Maximum Likelihood (ML) method by R software. Sequence analyses unambiguously identified the isolates as belonging to G. microti, showing 99% of identity with those of its isolates available in GenBank. A well-defined cluster, supported by significant bootstrap values and corresponding to the G. microti cluster, including sequences obtained from M. guentheri, was evidenced in the ML tree, confirming species assignment. The present finding represents the first report of G. microti from pet animals in Italy.


Assuntos
Arvicolinae , Giardia/isolamento & purificação , Giardíase/diagnóstico , Animais , Fezes/parasitologia , Giardia/classificação , Giardíase/parasitologia , Itália , Animais de Estimação , Reação em Cadeia da Polimerase/veterinária , RNA de Protozoário/análise , RNA Ribossômico 18S/análise
13.
Sensors (Basel) ; 20(18)2020 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-32961673

RESUMO

The aim of Lab-on-a-chip systems is the downscaling of analytical protocols into microfluidic devices, including optical measurements. In this context, the growing interest of the scientific community in opto-microfluidic devices has fueled the development of new materials. Recently, lithium niobate has been presented as a promising material for this scope, thanks to its remarkable optical and physicochemical properties. Here, we present a novel microfluidic device realized starting from a lithium niobate crystal, combining engraved microfluidic channels with integrated and self-aligned optical waveguides. Notably, the proposed microfabrication strategy does not compromise the optical coupling between the waveguides and the microchannel, allowing one to measure the transmitted light through the liquid flowing in the channel. In addition, the device shows a high versatility in terms of the optical properties of the light source, such as wavelength and polarization. Finally, the developed opto-microfluidic system is successfully validated as a probe for real-time pH monitoring of the liquid flowing inside the microchannel, showing a high integrability and fast response.

14.
Biosens Bioelectron ; 102: 531-539, 2018 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-29216580

RESUMO

Magnetic solid phase substrates for biomolecule manipulation have become a valuable tool for simplification and automation of molecular biology protocols. However, the handling of magnetic particles inside microfluidic chips for miniaturized assays is often challenging due to inefficient mixing, aggregation, and the advanced instrumentation required for effective actuation. Here, we describe the use of a microfluidic magnetic fluidized bed approach that enables dynamic, highly efficient and simplified magnetic bead actuation for DNA analysis in a continuous flow platform with minimal technical requirements. We evaluate the performance of this approach by testing the efficiency of individual steps of a DNA assay based on padlock probes and rolling circle amplification. This assay comprises common nucleic acid analysis principles, such as hybridization, ligation, amplification and restriction digestion. We obtained efficiencies of up to 90% for these reactions with high throughput processing up to 120µL of DNA dilution at flow rates ranging from 1 to 5µL/min without compromising performance. The fluidized bed was 20-50% more efficient than a commercially available solution for microfluidic manipulation of magnetic beads. Moreover, to demonstrate the potential of this approach for integration into micro-total analysis systems, we optimized the production of a low-cost polymer based microarray and tested its analytical performance for integrated single-molecule digital read-out. Finally, we provide the proof-of-concept for a single-chamber microfluidic chip that combines the fluidized bed with the polymer microarray for a highly simplified and integrated magnetic bead-based DNA analyzer, with potential applications in diagnostics.


Assuntos
Técnicas Biossensoriais/métodos , DNA/isolamento & purificação , Técnicas Analíticas Microfluídicas/métodos , Técnicas de Diagnóstico Molecular/métodos , DNA/química , Dispositivos Lab-On-A-Chip , Magnetismo , Hibridização de Ácido Nucleico
15.
Methods Mol Biol ; 1612: 269-279, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28634950

RESUMO

During tumor progression, cancer cells acquire the ability to escape the primary tumor and invade adjacent tissues. They migrate through the stroma to reach blood or lymphatics vessels that will allow them to disseminate throughout the body and form metastasis at distant organs. To assay invasion capacity of cells in vitro, multicellular spheroids of cancer cells, mimicking primary tumor, are commonly embedded in collagen I extracellular matrix, which mimics the stroma. However, due to their higher density, spheroids tend to sink at the bottom of the collagen droplets, resulting in the spreading of the cells on two dimensions. We developed an innovative method based on droplet microfluidics to embed and control the position of multicellular spheroids inside spherical droplets of collagen. In this method cancer cells are exposed to a uniform three-dimensional (3D) collagen environment resulting in 3D cell invasion.


Assuntos
Colágeno/química , Microfluídica/métodos , Invasividade Neoplásica , Esferoides Celulares/citologia , Animais , Linhagem Celular Tumoral , Movimento Celular , Humanos , Camundongos , Microfluídica/instrumentação , Modelos Biológicos , Células NIH 3T3 , Esferoides Celulares/patologia
16.
Methods Mol Biol ; 1547: 113-121, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28044291

RESUMO

Analyses of nucleic acids are routinely performed in hospital laboratories to detect gene alterations for cancer diagnosis and treatment decision. Among the different possible investigations, mRNA analysis provides information on abnormal levels of genes expression. Standard laboratory methods are still not adapted to the isolation and quantitation of low mRNA amounts and new techniques needs to be developed in particular for rare subsets analysis. By reducing the volume involved, time process, and the contamination risks, droplet microfluidics provide numerous advantages to perform analysis down to the single cell level.We report on a droplet microfluidic platform based on the manipulation of magnetic particles that allows the clinical analysis of tumor tissues. In particular, it allows the extraction of mRNA from the total-RNA sample, Reverse Transcription, and cDNA amplification, all in droplets.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/instrumentação , Microfluídica/métodos , Neoplasias/diagnóstico , Biomarcadores Tumorais , Humanos , Neoplasias/genética , Reprodutibilidade dos Testes , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Fluxo de Trabalho
17.
Analyst ; 141(20): 5776-5783, 2016 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-27486596

RESUMO

In this work, we have investigated Dyneon THV, a fluorinated material, as a new material to afford electrokinetic separations in microfluidic devices. To overcome protein adsorption, two poly(ethylene oxide) (PEO)-based coatings have been investigated: Pluronic F127 and PEO stearate 40. The best results were obtained with the PEO stearate 40 coating which allowed decreasing the surface contact angle from 91 ± 3 to 76°± 3. With this surface treatment, a 66% reduction of the electroosmotic mobility at pH 8.0 and a marked suppression of protein adsorption were observed compared to a native Dyneon THV microchip. Finally, a separation of fluorescently labeled proteins (bovine serum albumin and trypsin inhibitor), well-known for their strong tendency to adsorb on hydrophobic surfaces, was successfully achieved in an HEPES buffer with a PEO stearate 40 treated microchip by capillary zone electrophoresis. Furthermore, we demonstrated the possibility to perform non-aqueous capillary electrophoresis analysis of hydrophobic dyes using various solvents in untreated microchips. The overall results demonstrated not only the suitability of the Dyneon THV microchip for electrokinetic separations, but also its versatility allowing different separation modes to be implemented with the same microchip material.

18.
Sci Rep ; 6: 25540, 2016 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-27157697

RESUMO

The development of precision medicine, together with the multiplication of targeted therapies and associated molecular biomarkers, call for major progress in genetic analysis methods, allowing increased multiplexing and the implementation of more complex decision trees, without cost increase or loss of robustness. We present a platform combining droplet microfluidics and magnetic tweezers, performing RNA purification, reverse transcription and amplification in a fully automated and programmable way, in droplets of 250nL directly sampled from a microtiter-plate. This platform decreases sample consumption about 100 fold as compared to current robotized platforms and it reduces human manipulations and contamination risk. The platform's performance was first evaluated on cell lines, showing robust operation on RNA quantities corresponding to less than one cell, and then clinically validated with a cohort of 21 breast cancer samples, for the determination of their HER2 expression status, in a blind comparison with an established routine clinical analysis.


Assuntos
Fenômenos Magnéticos , Microfluídica/métodos , Neoplasias/diagnóstico , Neoplasias/metabolismo , Receptor ErbB-2/metabolismo , Calibragem , Linhagem Celular Tumoral , Humanos
19.
Langmuir ; 28(39): 13919-23, 2012 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-22946759

RESUMO

We report the results of comprehensive experiments and numerical calculations of interfacial morphologies of water confined to the hydrophilic top face of rectangular posts of width W = 500 µm and lengths between L = 5W and 30W. A continuous evolution of the interfacial shape from a homogeneous liquid filament to a bulged filament and back is observed during changes in the liquid volume. Above a certain threshold length of L* = 16.0W, the transition between the two morphologies is discontinuous and a bistability of interfacial shapes is observed in a certain interval of the reduced liquid volume V/W(3).

20.
Lab Chip ; 12(20): 4041-3, 2012 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-22907593

RESUMO

A post functionalization method for the control of the wettability of thiolene resins of the NOA family is presented. Treatment of open model surfaces or closed microchannels with chlorosilane derivatives resulted in dramatic changes in the behaviour of droplets and streams contacting the surfaces. The experimental findings are confirmed by the fabrication of a Y-junction device that works as a passive valve for water streams.


Assuntos
Técnicas Analíticas Microfluídicas/métodos , Polímeros/química , Silanos/química , Molhabilidade , Técnicas Analíticas Microfluídicas/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...