Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Sensors (Basel) ; 23(7)2023 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-37050629

RESUMO

In the highly competitive injection molding industry, the ability to effectively collect information from various sensors installed in molds and machines is of the utmost relevance, enabling the development of data-based Industry 4.0 algorithms. In this work, an alternative to commercially available monitoring systems used in the industry was developed and tested in the scope of the TOOLING 4G project. The novelty of this system is its affordability, simplicity, real-time data acquisition and display in an intuitive Graphical User Interface (GUI), while being open-source firmware and software-based. These characteristics, and their combinations have been present in previous works, but, to the authors' knowledge, not all of them simultaneously. The system used an Arduino microcontroller-based data acquisition module that can be connected to any computer via a USB port. Software was developed, including a GUI, prepared to receive data from both the Arduino module and a second module. In the current state of development, data corresponding to a maximum of six sensors can be visualized, at a rate of 10 Hz, and recorded for later usage. These capabilities were verified under real-world conditions for monitoring an injection mold with the objective of creating the basis of a platform to deploy predictive maintenance. Mold temperature, cavity pressure, 3-axis acceleration, and extraction force data showed the system can successfully monitor the mold and allowed the clear distinction between normal and abnormal operating patterns.

3.
Sensors (Basel) ; 22(7)2022 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-35408143

RESUMO

The world population growth and average life expectancy rise have increased the number of people suffering from non-communicable diseases, namely osteoarthritis, a disorder that causes a significant increase in the years lived with disability. Many people who suffer from osteoarthritis undergo replacement surgery. Despite the relatively high success rate, around 10% of patients require revision surgeries, mostly because existing implant technologies lack sensing devices capable of monitoring the bone-implant interface. Among the several monitoring methodologies already proposed as substitutes for traditional imaging methods, cosurface capacitive sensing systems hold the potential to monitor the bone-implant fixation states, a mandatory capability for long-term implant survival. A multifaceted study is offered here, which covers research on the following points: (1) the ability of a cosurface capacitor network to effectively monitor bone loosening in extended peri-implant regions and according to different stimulation frequencies; (2) the ability of these capacitive architectures to provide effective sensing in interfaces with hydroxyapatite-based layers; (3) the ability to control the operation of cosurface capacitive networks using extracorporeal informatic systems. In vitro tests were performed using a web-based network sensor composed of striped and interdigitated capacitive sensors. Hydroxyapatite-based layers have a minor effect on determining the fixation states; the effective operation of a sensor network-based solution communicating through a web server hosted on Raspberry Pi was shown. Previous studies highlight the inability of current bone-implant fixation monitoring methods to significantly reduce the number of revision surgeries, as well as promising results of capacitive sensing systems to monitor micro-scale and macro-scale bone-interface states. In this study, we found that extracorporeal informatic systems enable continuous patient monitoring using cosurface capacitive networks with or without hydroxyapatite-based layers. Findings presented here represent significant advancements toward the design of future multifunctional smart implants.


Assuntos
Durapatita , Osteoartrite , Transplante Ósseo/métodos , Humanos , Próteses e Implantes , Reoperação/métodos
4.
NPJ Regen Med ; 6(1): 80, 2021 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-34815414

RESUMO

Replacement orthopedic surgeries are among the most common surgeries worldwide, but clinically used passive implants cannot prevent failure rates and inherent revision arthroplasties. Optimized non-instrumented implants, resorting to preclinically tested bioactive coatings, improve initial osseointegration but lack long-term personalized actuation on the bone-implant interface. Novel bioelectronic devices comprising biophysical stimulators and sensing systems are thus emerging, aiming for long-term control of peri-implant bone growth through biointerface monitoring. These acting-sensing dual systems require high frequency (HF) operations able to stimulate osteoinduction/osteoconduction, including matrix maturation and mineralization. A sensing-compatible capacitive stimulator of thin interdigitated electrodes and delivering an electrical 60 kHz HF stimulation, 30 min/day, is here shown to promote osteoconduction in pre-osteoblasts and osteoinduction in human adipose-derived mesenchymal stem cells (hASCs). HF stimulation through this capacitive interdigitated system had significant effects on osteoblasts' collagen-I synthesis, matrix, and mineral deposition. A proteomic analysis of microvesicles released from electrically-stimulated osteoblasts revealed regulation of osteodifferentiation and mineralization-related proteins (e.g. Tgfb3, Ttyh3, Itih1, Aldh1a1). Proteomics data are available via ProteomeXchange with the identifier PXD028551. Further, under HF stimulation, hASCs exhibited higher osteogenic commitment and enhanced hydroxyapatite deposition. These promising osteoinductive/conductive capacitive stimulators will integrate novel bioelectronic implants able to monitor the bone-implant interface and deliver personalized stimulation to peri-implant tissues.

5.
Sci Rep ; 11(1): 3449, 2021 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-33568680

RESUMO

Instrumented implants are being developed with a radically innovative design to significantly reduce revision surgeries. Although bone replacements are among the most prevalent surgeries performed worldwide, implant failure rate usually surpasses 10%. High sophisticated multifunctional bioelectronic implants are being researched to incorporate cosurface capacitive architectures with ability to deliver personalized electric stimuli to peri-implant target tissues. However, the ability of these architectures to detect bone-implant interface states has never been explored. Moreover, although more than forty technologies were already proposed to detect implant loosening, none is able to ensure effective monitoring of the bone-implant debonding, mainly during the early stages of loosening. This work shows, for the first time, that cosurface capacitive sensors are a promising technology to provide an effective monitoring of bone-implant interfaces during the daily living of patients. Indeed, in vitro experimental tests and simulation with computational models highlight that both striped and circular capacitive architectures are able to detect micro-scale and macro-scale interface bonding, debonding or loosening, mainly when bonding is weakening or loosening is occurring. The proposed cosurface technologies hold potential to implement highly effective and personalized sensing systems such that the performance of multifunctional bioelectronic implants can be strongly improved. Findings were reported open a new research line on sensing technologies for bioelectronic implants, which may conduct to great impacts in the coming years.

6.
Sensors (Basel) ; 20(1)2019 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-31878028

RESUMO

Musculoskeletal disorders are becoming an ever-growing societal burden and, as a result, millions of bone replacements surgeries are performed per year worldwide. Despite total joint replacements being recognized among the most successful surgeries of the last century, implant failure rates exceeding 10% are still reported. These numbers highlight the necessity of technologies to provide an accurate monitoring of the bone-implant interface state. This study provides a detailed review of the most relevant methodologies and technologies already proposed to monitor the loosening states of endoprosthetic implants, as well as their performance and experimental validation. A total of forty-two papers describing both intracorporeal and extracorporeal technologies for cemented or cementless fixation were thoroughly analyzed. Thirty-eight technologies were identified, which are categorized into five methodologies: vibrometric, acoustic, bioelectric impedance, magnetic induction, and strain. Research efforts were mainly focused on vibrometric and acoustic technologies. Differently, approaches based on bioelectric impedance, magnetic induction and strain have been less explored. Although most technologies are noninvasive and are able to monitor different loosening stages of endoprosthetic implants, they are not able to provide effective monitoring during daily living of patients.


Assuntos
Transplante Ósseo/métodos , Falha de Prótese , Humanos , Magnetismo , Som , Vibração
7.
Sci Rep ; 9(1): 5001, 2019 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-30899061

RESUMO

Cosurface electrode architectures are able to deliver personalized electric stimuli to target tissues. As such, this technology holds potential for a variety of innovative biomedical devices. However, to date, no detailed analyses have been conducted to evaluate the impact of stimulator architecture and geometry on stimuli features. This work characterizes, for the first time, the electric stimuli delivered to bone cellular tissues during in vitro experiments, when using three capacitive architectures: stripped, interdigitated and circular patterns. Computational models are presented that predict the influence of cell confluence, cosurface architecture, electrodes geometry, gap size between electrodes and power excitation on the stimuli delivered to cellular layers. The results demonstrate that these stimulators are able to deliver osteoconductive stimuli. Significant differences in stimuli distributions were observed for different stimulator designs and different external excitations. The thickness specification was found to be of utmost importance. In vitro experiments using an osteoblastic cell line highlight that cosurface stimulation at a low frequency can enhance osteoconductive responses, with some electrode-specific differences being found. A major feature of this type of work is that it enables future detailed analyses of stimuli distribution throughout more complex biological structures, such as tissues and organs, towards sophisticated biodevice personalization.


Assuntos
Simulação por Computador , Estimulação Elétrica/instrumentação , Próteses e Implantes , Eletrodos , Humanos , Medicina de Precisão
8.
Sci Rep ; 6: 30231, 2016 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-27456818

RESUMO

Non-drug strategies based on biophysical stimulation have been emphasized for the treatment and prevention of musculoskeletal conditions. However, to date, an effective stimulation system for intracorporeal therapies has not been proposed. This is particularly true for active intramedullary implants that aim to optimize osseointegration. The increasing demand for these implants, particularly for hip and knee replacements, has driven the design of innovative stimulation systems that are effective in bone-implant integration. In this paper, a new cosurface-based capacitive system concept is proposed for the design of implantable devices that deliver controllable and personalized electric field stimuli to target tissues. A prototype architecture of this system was constructed for in vitro tests, and its ability to deliver controllable stimuli was numerically analyzed. Successful results were obtained for osteoblastic proliferation and differentiation in the in vitro tests. This work provides, for the first time, a design of a stimulation system that can be embedded in active implantable devices for controllable bone-implant integration and regeneration. The proposed cosurface design holds potential for the implementation of novel and innovative personalized stimulatory therapies based on the delivery of electric fields to bone cells.


Assuntos
Desenvolvimento Ósseo/fisiologia , Fixação Intramedular de Fraturas/métodos , Osseointegração/efeitos da radiação , Próteses e Implantes , Desenvolvimento Ósseo/efeitos da radiação , Diferenciação Celular/efeitos da radiação , Proliferação de Células/efeitos da radiação , Estimulação Elétrica , Humanos , Osseointegração/fisiologia , Propriedades de Superfície
9.
Sci Rep ; 6: 18579, 2016 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-26725842

RESUMO

Magnetic levitation has been used to implement low-cost and maintenance-free electromagnetic energy harvesting. The ability of levitation-based harvesting systems to operate autonomously for long periods of time makes them well-suited for self-powering a broad range of technologies. In this paper, a combined theoretical and experimental study is presented of a harvester configuration that utilizes the motion of a levitated hard-magnetic element to generate electrical power. A semi-analytical, non-linear model is introduced that enables accurate and efficient analysis of energy transduction. The model predicts the transient and steady-state response of the harvester a function of its motion (amplitude and frequency) and load impedance. Very good agreement is obtained between simulation and experiment with energy errors lower than 14.15% (mean absolute percentage error of 6.02%) and cross-correlations higher than 86%. The model provides unique insight into fundamental mechanisms of energy transduction and enables the geometric optimization of harvesters prior to fabrication and the rational design of intelligent energy harvesters.

10.
Expert Rev Med Devices ; 12(5): 571-84, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26202322

RESUMO

This article focuses on in vivo implementations of instrumented knee implants and recent prototypes with highly innovative potential. An in-depth analysis of the evolution of these systems was conducted, including three architectures developed by two research teams for in vivo operation that were implanted in 13 patients. The specifications of their various subsystems: sensor/transducers, power management, communication and processing/control units are presented, and their features are compared. These systems were designed to measure biomechanical quantities to further assist in rehabilitation and physical therapy, to access proper implant placement and joint function and to help predicting aseptic loosening. Five prototype systems that aim to improve their operation, as well as include new abilities, are also featured. They include technology to assist proper ligament tensioning and ensure self-powering. One can conclude that the concept of instrumented active knee implant seems the most promising trend for improving the outcomes of knee replacements.


Assuntos
Articulação do Joelho/cirurgia , Prótese do Joelho , Fenômenos Biomecânicos , Humanos , Articulação do Joelho/fisiopatologia , Ligamentos/fisiopatologia
11.
Expert Rev Med Devices ; 11(6): 617-35, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25234709

RESUMO

This paper reviews instrumented hip joint replacements, instrumented femoral replacements and instrumented femoral fracture stabilizers. Examination of the evolution of such implants was carried out, including the detailed analysis of 16 architectures, designed by 8 research teams and implanted in 32 patients. Their power supply, measurement, communication, processing and actuation systems were reviewed, as were the tests carried out to evaluate their performance and safety. These instrumented implants were only designed to measure biomechanical and thermodynamic quantities in vivo, in order to use such data to conduct research projects and optimize rehabilitation processes. The most promising trend is to minimize aseptic loosening and/or infection following hip or femoral replacements or femoral stabilization procedures by using therapeutic actuators inside instrumented implants to apply controlled stimuli in the bone-implant interface.


Assuntos
Fraturas do Fêmur/diagnóstico , Fraturas do Fêmur/cirurgia , Fêmur/cirurgia , Prótese de Quadril , Fixadores Internos , Monitorização Ambulatorial/instrumentação , Tecnologia sem Fio/instrumentação , Eletrônica Médica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Avaliação da Tecnologia Biomédica
12.
J Biomech ; 46(15): 2561-71, 2013 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-24050511

RESUMO

Instrumented hip implants were proposed as a method to monitor and predict the biomechanical and thermal environment surrounding such implants. Nowadays, they are being developed as active implants with the ability to prevent failures by loosening. The generation of electric energy to power active mechanisms of instrumented hip implants remains a question. Instrumented implants cannot be implemented without effective electric power systems. This paper surveys the power supply systems of seventeen implant architectures already implanted in-vivo, namely from instrumented hip joint replacements and instrumented fracture stabilizers. Only inductive power links and batteries were used in-vivo to power the implants. The energy harvesting systems, which were already designed to power instrumented hip implants, were also analyzed focusing their potential to overcome the disadvantages of both inductive-based and battery-based power supply systems. From comparative and critical analyses of the methods to power instrumented implants, one can conclude that: inductive powering and batteries constrain the full operation of instrumented implants; motion-driven electromagnetic energy harvesting is a promising method to power instrumented passive and active hip implants.


Assuntos
Fontes de Energia Elétrica , Prótese de Quadril , Humanos , Falha de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...