Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J. Bras. Patol. Med. Lab. (Online) ; 54(1): 14-20, Jan.-Feb. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-893596

RESUMO

ABSTRACT Introduction: The use of oral contraceptives increases women's risk of developing cardiovascular and thromboembolic diseases, due to alterations in hemostatic and lipid profile. Objectives: Analyze the association between the use of different types of oral contraceptives with lipid profile and levels of serum high-sensitivity C-reactive protein (hsCRP) and plasma D-dimer. Methods: One hundred fifty-four participants were divided into the following groups: control nonusers (n = 41), medium-dose users (n= 32), third-generation low-dose users (n = 40), and fourth-generation low-dose users (n = 41). Triglycerides and total cholesterol serum levels were determined by colorimetric enzymatic method; high-density lipoprotein (HDL) cholesterol levels, by precipitation method; low-density lipoprotein (LDL) cholesterol levels, by Friedewald equation; hsCRP levels, by immunoturbidimetric method; and D-dimer levels, by fluorescence immunoassay. Results: Oral contraceptive users had higher serum levels of triglycerides, total cholesterol, HDL cholesterol (HDL-C), HDL/LDL index and hsCRP compared to controls. Medium-dose users had higher D-dimer plasma levels than controls and higher triglycerides serum levels than low-dose users. Triglycerides, hsCRP and D-dimer were positively correlated to each other. Conclusion: The use of combined oral contraceptives was associated with an unfavorable lipid profile and a chronic subclinical inflammation, with atherogenic potential. Furthermore, medium-dose contraceptives induced a higher thrombogenic potential, since they were associated with increased D-dimer levels in comparison to low-dose ones.


RESUMO Introdução: O uso de anticoncepcionais orais aumenta o risco de desenvolvimento de doenças cardiovasculares e tromboembólicas devido a alterações no perfil lipídico e hemostático. Objetivo: Analisar a associação entre o uso de diferentes tipos de anticoncepcionais orais com o perfil lipídico e os níveis da proteína C reativa ultrassensível (PCRus) e do dímero D. Métodos: Cento e quarenta e cinco participantes foram divididas em: não usuárias (n = 41), usuárias de média dose (n = 32), usuárias de terceira geração de baixa dose (n = 40) e usuárias de quarta geração de baixa dose (n = 41). Níveis de triglicerídeos e colesterol total foram determinados pelo método enzimático colorimétrico; colesterol da lipoproteína de alta densidade (HDL), pelo método de precipitação; colesterol da lipoproteína de baixa densidade (LDL), pela equação de Friedewald; PCRus, por imunoturbidimetria; e dímero D, por imunoensaio fluorescente. Resultados: As usuárias de anticoncepcionais orais apresentaram maiores níveis de triglicerídeos, colesterol total, HDL, índice HDL/LDL e PCRus do que as não usuárias. As usuárias de anticoncepcionais de média dose apresentaram maiores níveis de dímero D do que as não usuárias, e maiores níveis de triglicerídeos do que as usuárias de anticoncepcionais de baixa dose. Triglicerídeos, PCRus e dímero D apresentaram correlação positiva uns com os outros. Conclusão: O uso de anticoncepcionais orais combinados está associado ao perfil lipídico desfavorável e à inflamação crônica subclínica, com potencial aterogênico. Além disso, os anticoncepcionais orais de média dose induziram maior potencial trombogênico, já que foram relacionados com níveis maiores de dímero D em comparação com os de baixa dose.

2.
Bioorg Med Chem ; 23(15): 4397-4404, 2015 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-26122772

RESUMO

Cardiotonic steroids (CS), natural compounds with traditional use in cardiology, have been recently suggested to exert potent anticancer effects. However, the repertoire of molecules with Na,K-ATPase activity and anticancer properties is limited. This paper describes the synthesis of 6 new digoxin derivatives substituted (on the C17-butenolide) with γ-benzylidene group and their cytotoxic effect on human fibroblast (WI-26 VA4) and cancer (HeLa and RKO) cell lines as well as their effect on Na,K-ATPase activity and expression. As digoxin, compound BD-4 was almost 100-fold more potent than the other derivatives for cytotoxicity with the three types of cells used and was also the only one able to fully inhibit the Na,K-ATPase of HeLa cells after 24h treatment. No change in the Na,K-ATPase α1 isoform protein expression was detected. On the other hand it was 30-40 fold less potent for direct Na,K-ATPase inhibition, when compared to the most potent derivatives, BD-1 and BD-3, and digoxin. The data presented here demonstrated that the anticancer effect of digoxin derivatives substituted with γ-benzylidene were not related with their inhibition of Na,K-ATPase activity or alteration of its expression, suggesting that this classical molecular mechanism of CS is not involved in the cytotoxic effect of our derivatives.


Assuntos
Antineoplásicos/síntese química , Compostos de Benzilideno/química , Digoxina/análogos & derivados , ATPase Trocadora de Sódio-Potássio/antagonistas & inibidores , Animais , Antineoplásicos/química , Antineoplásicos/toxicidade , Sítios de Ligação , Encéfalo/enzimologia , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Digoxina/síntese química , Digoxina/toxicidade , Células HeLa , Humanos , Rim/enzimologia , Simulação de Acoplamento Molecular , Estrutura Terciária de Proteína , Ratos , ATPase Trocadora de Sódio-Potássio/metabolismo
3.
Medicina (Ribeiräo Preto) ; 47(2): 131-142, abr.-jun. 2014.
Artigo em Português | LILACS | ID: lil-753430

RESUMO

A oscilometria de impulso (IOS) é considerado um método de avaliação da mecânica respiratória, e por ser não invasivo, vem sendo crescentemente indicado na assistência e investigação do paciente pediátrico. Estudos tem tido como interesse a determinação de valores de referência e a verificação da relação do IOS com outros métodos de avaliação respiratória. Objetivo: apresentar uma atualização da literatura quanto ao sistema, critérios técnicos e interpretação de dados, bem como, a relação do sistema com outros métodos de avaliação respiratória e sua aplicabilidade clínica. Método: revisão bibliográfica com consulta nas bases de dados MEDLINE/PubMed e Ebsco, utilizando as palavras-chaves:“impulse oscillometry”, “reference values” e “child”. Considerou-se todo material com informações sobre o equipamento, suas indicações e aplicação como instrumento de avaliação em diferentes situações clínicas. Resultados: foram identificados 45 documentos, sendo 41 ensaios clínicos e 4 revisões, complementados com 20 trabalhos: 1 guideline, 1 manual sobre o equipamento e 18 artigos referentes ao tema. Esse material foi caracterizado por abordar o equipamento, seus parâmetros de avaliação, técnica de execução e posicionamento do paciente durante o exame, critérios de aceitabilidade e reprodutibilidade e interpretação dos dados obtidos. São várias as publicações dessa ferramenta na avaliação da mecânica respiratória de disfunções como asma e fibrose cística e geração de valores de referência em crianças saudáveis. Conclusão: o IOS é um recurso relativamente novo, cuja indicação em pediatria tem sido crescente, mas que ainda carece investigações, tanto técnicas quanto clínicas...


Impulse oscillometry (IOS) is considered a method of evaluation of respiratory mechanics, and being non-invasive, has been increasingly mentioned in the care and research of pediatric patients. Studies have considered the interest of determining reference values and check the IOS relationship with other methods of respiratory assessment. Objective: to present an update of the literature regarding the system, technical criteria and interpretation of data, as well as the relationship of the system with other methods of respiratory assessment and its clinical applicability. Method: literature review with consultation in the databases MEDLINE / PubMed and Ebsco, using the keywords: “impulse oscillometry”, “reference values” and “child”. It was considered all material with information about the equipment, their indications and application as an evaluation tool in different clinical situations. Results: 45 documents were identified, (41 trials and 4 reviews), supplemented with 20 papers (1 guideline, 1 manual on equipment and 18 articles on the subject). This material was characterized by approaching the equipment, its parameters evaluation, performance technique and positioning of the patient during the examination, criteria for acceptability and reproducibility, and interpretation of the data obtained. There are several publications of this tool in the evaluation of respiratory mechanics disorders such as asthma and cystic fibrosis, and making on reference values in healthy children. Conclusion: IOS is a relatively new feature, whose indicationin pediatrics has been increasing, but still required investigations, both technical and clinical investigations...


Assuntos
Humanos , Criança , Oscilometria , Testes de Função Respiratória , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...