Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Int J Cardiovasc Imaging ; 32(5): 729-39, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26723574

RESUMO

Stenting for CoA has become an acceptable treatment modality in the last 20 years. However little is known about arterial changes after this procedure. To assess arterial structure and function including peripheral reactivity and stiffness and intima-media thickness (IMT) pre and post stenting for coarctation of the aorta (CoA). Twenty-one patients [median age: 15 years (8-39)] were studied at baseline, 1 day, 6 months and 1 year after stenting. Twenty-one healthy subjects (1:1 matched) were used as controls. Left ventricular (LV) mass, ejection fraction, flow-mediated dilation (FMD) and nitrate-mediated dilation (NMD) of left brachial artery, common carotid (CC) and right subclavian artery (RSCA) IMT and pulse wave velocity (PWV) were assessed by echocardiography and vascular ultrasound. CoA patients had higher LV indexed mass (p < 0.0001), impaired FMD (p < 0.0001) and NMD (p < 0.0001), increased PWV (p < 0.0001), carotid and RSCA IMT (both p < 0.0001). All procedures were successful and resulted in significant gradient reduction (p < 0.001). One year after stenting there was improvement in LV function (p = 0.034) and although there was significant reduction of LV mass (103.29 ± 24.77 vs. 74.39 ± 22.07 g/m(2), p < 0.0001) values did not normalize. There was no significant change in FMD, NMD, PWV and CC or RSCA IMT. In patients with CoA, arterial reactivity is impaired and LV mass, arterial stiffness and thickness are increased. Although stenting is successful to relieve the obstruction resulting in better LV function and mass reduction, arterial structure and function remains abnormal after 1 year of follow-up.


Assuntos
Coartação Aórtica/terapia , Artéria Braquial , Artérias Carótidas , Procedimentos Endovasculares/instrumentação , Stents , Artéria Subclávia , Adolescente , Adulto , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/fisiopatologia , Aortografia/métodos , Artéria Braquial/diagnóstico por imagem , Artéria Braquial/fisiopatologia , Brasil , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiopatologia , Espessura Intima-Media Carotídea , Criança , Angiografia por Tomografia Computadorizada , Ecocardiografia , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Análise de Onda de Pulso , Recuperação de Função Fisiológica , Reprodutibilidade dos Testes , Volume Sistólico , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler , Remodelação Vascular , Rigidez Vascular , Vasodilatação , Função Ventricular Esquerda , Adulto Jovem
2.
Int J Cardiovasc Imaging ; 32(5): 729-739, 2016.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1063481

RESUMO

Stenting for CoA has become an acceptable treatment modality in the last 20 years. However little is known about arterial changes after this procedure. To assess arterial structure and function including peripheral reactivity and stiffness and intima-media thickness (IMT) pre and post stenting for coarctation of the aorta (CoA). Twenty-one patients [median age: 15 years (8-39)] were studied at baseline, 1 day, 6 months and 1 year after stenting. Twenty-one healthy subjects (1:1 matched) were used as controls. Left ventricular (LV) mass, ejection fraction, flow-mediated dilation (FMD) and nitrate-mediated dilation (NMD) of left brachial artery, common carotid (CC) and right subclavian artery (RSCA) IMT and pulse wave velocity (PWV) were assessed by echocardiography and vascular ultrasound. CoA patients had higher LV indexed mass (p < 0.0001), impaired FMD (p < 0.0001) and NMD (p < 0.0001), increased PWV (p < 0.0001), carotid and RSCA IMT (both p < 0.0001). All procedures were successful and resulted in significant gradient reduction (p < 0.001). One year after stenting there was improvement in LV function (p = 0.034) and although there was significant reduction of LV mass (103.29 ± 24.77 vs...


Assuntos
Espessura Intima-Media Carotídea , Stents , Vasodilatação
3.
J Cardiovasc Pharmacol ; 55(1): 1-5, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19770669

RESUMO

BACKGROUND: Coadministration of any statin with ezetimibe is as effective as using high doses of the same statin in the reduction of low-density lipoprotein cholesterol (LDL-c). There may be other effects called pleiotropics. OBJECTIVE: To compare the effectiveness of 2 different treatments that obtain equivalent LDL-c reductions (80 mg of simvastatin, once a day and coadministration of 10 mg of simvastatin and 10 mg of ezetimibe, once a day) over endothelial function and inflammation. METHODS: Twenty-three randomized patients with hypercholesterolemia in a 2 x 2 crossover protocol were studied. Endothelial function was analyzed by ultrasound assessment of endothelial dependent flow-mediated vasodilation of the brachial artery, and inflammation was estimated by high-sensitivity C-reactive protein (hs-CRP). RESULTS: LDL-c reduction was similar between the 2 treatments with simvastatin/ezetimibe and with simvastatin (P < 0.001); no difference between treatments was found (P = 0.968). Both treatments improved significantly the endothelial function [3.61% with simvastatin/ezetimibe (P = 0.003) and 5.08% with simvastatin (P < 0.001)]; no difference was found between the 2 treatments (P = 0.291). hs-CRP had a 23% reduction with simvastatin/ezetimibe (P = 0.004) and a 30% reduction with simvastatin alone (P = 0.01), with no significant difference between the 2 treatments (P = 0.380). CONCLUSION: The 2 forms of treatment presented similar pleiotropic effects: improvement in endothelial function and decrease in hs-CRP levels.


Assuntos
Anticolesterolemiantes/uso terapêutico , Azetidinas/uso terapêutico , Hipercolesterolemia/tratamento farmacológico , Sinvastatina/uso terapêutico , Adolescente , Adulto , Idoso , Anticolesterolemiantes/administração & dosagem , Azetidinas/administração & dosagem , Artéria Braquial/diagnóstico por imagem , Artéria Braquial/metabolismo , Proteína C-Reativa/metabolismo , LDL-Colesterol/sangue , LDL-Colesterol/efeitos dos fármacos , Estudos Cross-Over , Quimioterapia Combinada , Endotélio Vascular/efeitos dos fármacos , Endotélio Vascular/metabolismo , Ezetimiba , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sinvastatina/administração & dosagem , Ultrassonografia , Vasodilatação/efeitos dos fármacos , Adulto Jovem
4.
J Cardiovasc Pharmacol ; 55: 1-5, 2010.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1063650

RESUMO

Background: Coadministration of any statin with ezetimibe is as effective as using high doses of the same statin in the reduction of low-density lipoprotein cholesterol (LDL-c). There may be other effects called pleiotropics. Objective: To compare the effectiveness of 2 different treatments that obtain equivalent LDL-c reductions (80 mg of simvastatin, once a day and coadministration of 10 mg of simvastatin and 10 mg of ezetimibe, once a day) over endothelial function and inflammation. Methods: Twenty-three randomized patients with hypercholesterolemia in a 2 3 2 crossover protocol were studied. Endothelial function was analyzed by ultrasound assessment of endothelial dependent flow-mediated vasodilation of the brachial artery, and inflammation was estimated by high-sensitivity C-reactive protein (hs-CRP). Results: LDL-c reduction was similar between the 2 treatments with simvastatin/ezetimibe and with simvastatin (P , 0.001); no difference between treatments was found (P = 0.968). Both treatments improved significantly the endothelial function [3.61% with simvastatin/


ezetimibe (P = 0.003) and 5.08% with simvastatin (P , 0.001)]; no difference was found between the 2 treatments (P = 0.291). hs-CRP had a 23% reduction with simvastatin/ezetimibe (P = 0.004) and a 30% reduction with simvastatin alone (P = 0.01), with no significant difference between the 2 treatments (P = 0.380).


Assuntos
Endotélio , Hipercolesterolemia
5.
Arq. bras. cardiol ; 77(5): 471-486, Nov. 2001. ilus, tab
Artigo em Português, Inglês | LILACS, Sec. Est. Saúde SP | ID: lil-299308

RESUMO

We report new percutaneous techniques for perforating the pulmonary valve in pulmonary atresia with intact ventricular septum, in 3 newborns who had this birth defect. There was mild to moderate hypoplastic right ventricle, a patent infundibulum, and no coronary-cavitary communications. We succeeded in all cases, and no complications related to the procedure occurred. The new coaxial radiofrequency system was easy to handle, which simplified the procedure. Two patients required an additional source of pulmonary flow (Blalock-Taussig shunt) in the first week after catheterization. All patients had a satisfactory short-term clinical evolution and will undergo recatheterization within 1 year to define the next therapeutic strategy. We conclude that this technique may be safely and efficiently performed, especially when the new coaxial radiofrequency system is used, and it may become the initial treatment of choice in select neonates with pulmonary atresia and intact ventricular septum


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Valva Pulmonar , Ablação por Cateter , Atresia Pulmonar , Septos Cardíacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...