Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Foodborne Pathog Dis ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38708682

RESUMO

Hepatitis E virus (HEV) infects roughly 20 million people worldwide, causing self-limiting acute hepatic disease that can evolve into a chronic course. HEV-3, HEV-4, and HEV-7 genotypes are zoonotic and transmitted to humans by consuming raw or undercooked meat. Here, we developed an indirect ELISA based on the recombinant HEV-3 capsid and performed a seroprevalence study on domestic swine in northeastern Brazil. Our in-house ELISA was initially validated using a subset of 79 sera characterized by concordant results for two distinct commercial ELISA kits. Our ELISA exhibited excellent sensitivity (94%) and specificity (100%), with an area under the curve of 0.99 Further testing, including 212 swine sera, revealed a seroprevalence of 57.5% (95% confidence interval, 50.6-64.3%). Our findings indicate that the novel ELISA test could accurately detect specific anti-HEV antibodies in domestic pigs and should be further validated in humans and other mammals.

2.
J Clin Virol ; 138: 104796, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33773413

RESUMO

Antigen-detecting rapid diagnostic tests (Ag-RDTs) can complement molecular diagnostics for COVID-19. The recommended temperature for storage of SARS-CoV-2 Ag-RDTs ranges between 2-30 °C. In the global South, mean temperatures can exceed 30 °C. In the global North, Ag-RDTs are often used in external testing facilities at low ambient temperatures. We assessed analytical sensitivity and specificity of eleven commercially-available SARS-CoV-2 Ag-RDTs using different storage and operational temperatures, including short- or long-term storage and operation at recommended temperatures or at either 2-4 °C or at 37 °C. The limits of detection of SARS-CoV-2 Ag-RDTs under recommended conditions ranged from 1.0×106- 5.5×107 genome copies/mL of infectious SARS-CoV-2 cell culture supernatant. Despite long-term storage at recommended conditions, 10 min pre-incubation of Ag-RDTs and testing at 37 °C resulted in about ten-fold reduced sensitivity for five out of 11 SARS-CoV-2 Ag-RDTs, including both Ag-RDTs currently listed for emergency use by the World Health Organization. After 3 weeks of storage at 37 °C, eight of the 11 SARS-CoV-2 Ag-RDTs exhibited about ten-fold reduced sensitivity. Specificity of SARS-CoV-2 Ag-RDTs using cell culture supernatant from common respiratory viruses was not affected by storage and testing at 37 °C, whereas false-positive results occurred at outside temperatures of 2-4 °C for two out of six tested Ag-RDTs, again including an Ag-RDT recommended by the WHO. In summary, elevated temperatures impair sensitivity, whereas low temperatures impair specificity of SARS-CoV-2 Ag-RDTs. Consequences may include false-negative test results at clinically relevant virus concentrations compatible with transmission and false-positive results entailing unwarranted quarantine assignments. Storage and operation of SARS-CoV-2 Ag-RDTs at recommended conditions is essential for successful usage during the pandemic.


Assuntos
Teste Sorológico para COVID-19 , COVID-19/diagnóstico , Testes Diagnósticos de Rotina , Kit de Reagentes para Diagnóstico , Temperatura Baixa/efeitos adversos , Reações Falso-Negativas , Reações Falso-Positivas , Temperatura Alta/efeitos adversos , Humanos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...