Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
J Med Imaging Radiat Oncol ; 66(2): 193-201, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35243789

RESUMO

INTRODUCTION: The Royal Australian and New Zealand College of Radiologists (RANZCR) established a working group to explore how the college should engage with the future development of structured radiology reporting in our region, particularly in the context of a broader move to digital healthcare. Phase 1 of the project surveyed college members and affiliated interest groups about how they are using structured reporting currently and might like it to evolve. METHODS: Member and interest group questionnaires were based on previously published studies and posted to the Survey Monkey platform. Responses were analysed descriptively. RESULTS: There were 114 members and 58 affiliated group responses. There is clearest support for RANZCR developing guidelines around structured report quality, for improvements in report content, particularly tailoring to clinical context and study parameters, and for improved integration of structured reporting and RIS/PACS systems. CONCLUSIONS: Phase 2 of the structured reporting working group project will aim to develop guidelines for structured report quality and processes through which RANZCR can implement them.


Assuntos
Sistemas de Informação em Radiologia , Radiologia , Austrália , Humanos , Radiografia , Radiologistas , Inquéritos e Questionários
2.
J Gerontol B Psychol Sci Soc Sci ; 74(7): 1121-1131, 2019 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-29471348

RESUMO

OBJECTIVES: The onset of many illnesses is confounded with age and sex. Increasing age is a risk factor for the development of many illnesses, and sexual dimorphism influences brain anatomy, function, and cognition. Here, we examine frequency-specific connectivity in resting-state networks in a large sample (n = 406) of healthy aged adults. METHOD: We quantify frequency-specific connectivity in three resting-state networks known to be implicated in age-related decline: the default mode, dorsal attention, and salience networks, using multiband functional magnetic resonance imaging. Frequency-specific connectivity was quantified in four bands: low (0.015-0.027 Hz), moderately low (0.027-0.073 Hz), moderately high (0.073-0.198 Hz), and high (0.198-0.5 Hz) frequency bands, using mean intensity and spatial extent. Differences in connectivity between the sexes in each of the three networks were examined. RESULTS: Each network showed the largest intensity and spatial extent at low frequencies and smallest extent at high frequencies. Males showed greater connectivity than females in the salience network. Females showed greater connectivity than males in the default mode network. DISCUSSION: Results in this healthy aged cohort are compatible with those obtained in young samples, suggesting that frequency-specific connectivity, and differences between the sexes, are maintained into older age. Our results indicate that sex should be considered as an influencing factor in studies of resting-state connectivity.


Assuntos
Envelhecimento/fisiologia , Córtex Cerebral/fisiologia , Conectoma , Rede Nervosa/fisiologia , Tálamo/fisiologia , Idoso , Idoso de 80 Anos ou mais , Cerebelo/diagnóstico por imagem , Cerebelo/fisiologia , Córtex Cerebral/diagnóstico por imagem , Estudos de Coortes , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Estudos Multicêntricos como Assunto , Rede Nervosa/diagnóstico por imagem , Ensaios Clínicos Controlados Aleatórios como Assunto , Tálamo/diagnóstico por imagem
3.
BMC Med Imaging ; 18(1): 41, 2018 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-30400875

RESUMO

BACKGROUND: Attenuation correction is one of the most crucial correction factors for accurate PET data quantitation in hybrid PET/MR scanners, and computing accurate attenuation coefficient maps from MR brain acquisitions is challenging. Here, we develop a method for accurate bone and air segmentation using MR ultrashort echo time (UTE) images. METHODS: MR UTE images from simultaneous MR and PET imaging of five healthy volunteers was used to generate a whole head, bone and air template image for inclusion into an improved MR derived attenuation correction map, and applied to PET image data for quantitative analysis. Bone, air and soft tissue were segmented based on Gaussian Mixture Models with probabilistic tissue maps as a priori information. We present results for two approaches for bone attenuation coefficient assignments: one using a constant attenuation correction value; and another using an estimated continuous attenuation value based on a calibration fit. Quantitative comparisons were performed to evaluate the accuracy of the reconstructed PET images, with respect to a reference image reconstructed with manually segmented attenuation maps. RESULTS: The DICE coefficient analysis for the air and bone regions in the images demonstrated improvements compared to the UTE approach, and other state-of-the-art techniques. The most accurate whole brain and regional brain analyses were obtained using constant bone attenuation coefficient values. CONCLUSIONS: A novel attenuation correction method for PET data reconstruction is proposed. Analyses show improvements in the quantitative accuracy of the reconstructed PET images compared to other state-of-the-art AC methods for simultaneous PET/MR scanners. Further evaluation is needed with radiopharmaceuticals other than FDG, and in larger cohorts of participants.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/normas , Adulto , Algoritmos , Fluordesoxiglucose F18/administração & dosagem , Voluntários Saudáveis , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Compostos Radiofarmacêuticos/administração & dosagem , Adulto Jovem
4.
Hum Brain Mapp ; 39(12): 5126-5144, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30076750

RESUMO

Simultaneous Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) scanning is a recent major development in biomedical imaging. The full integration of the PET detector ring and electronics within the MR system has been a technologically challenging design to develop but provides capacity for simultaneous imaging and the potential for new diagnostic and research capability. This article reviews state-of-the-art MR-PET hardware and software, and discusses future developments focusing on neuroimaging methodologies for MR-PET scanning. We particularly focus on the methodologies that lead to an improved synergy between MRI and PET, including optimal data acquisition, PET attenuation and motion correction, and joint image reconstruction and processing methods based on the underlying complementary and mutual information. We further review the current and potential future applications of simultaneous MR-PET in both systems neuroscience and clinical neuroimaging research. We demonstrate a simultaneous data acquisition protocol to highlight new applications of MR-PET neuroimaging research studies.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Neuroimagem/métodos , Neurociências/métodos , Tomografia por Emissão de Pósitrons/métodos , Humanos , Processamento de Imagem Assistida por Computador/normas , Imageamento por Ressonância Magnética/normas , Imagem Multimodal/normas , Neuroimagem/normas , Neurociências/normas , Tomografia por Emissão de Pósitrons/normas
5.
Neuroimage ; 165: 294-305, 2018 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-29079523

RESUMO

PURPOSE: To improve the accuracy of automated vein segmentation by combining susceptibility-weighted images (SWI), quantitative susceptibility maps (QSM), and a vein atlas to produce a resultant image called a composite vein image (CV image). METHOD: An atlas was constructed in common space from manually traced MRI images from ten volunteers. The composite vein image was derived for each subject as a weighted sum of three inputs; an SWI image, a QSM image and the vein atlas. The weights for each input and each anatomical location, called template priors, were derived by assessing the accuracy of each input over an independent data set. The accuracy of vein segmentations derived automatically from each of the CV image, SWI, and QSM image sets was assessed by comparison with manual tracings. Three different automated vein segmentation techniques were used, and ten performance metrics evaluated. RESULTS: Vein segmentations using the CV image were comprehensively better than those derived from SWI or QSM images (mean Cohen's d = 1.1). Sixty permutations of performance metric, benchmark image, and automated segmentation technique were evaluated. Vein identification improvements that were both large and significant (Cohen's d > 0.80, p < 0.05) were found in 77% of the permutations, compared to no improvement in 5%. CONCLUSION: The accuracy of automated vein segmentations derived from the composite vein image was overwhelmingly superior to segmentations derived from SWI or QSM alone.


Assuntos
Encéfalo/irrigação sanguínea , Processamento de Imagem Assistida por Computador/métodos , Veias/diagnóstico por imagem , Atlas como Assunto , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética , Masculino
7.
Brain Behav ; 7(2): e00608, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28239519

RESUMO

BACKGROUND AND OBJECTIVE: The medial forebrain bundle (MFB) contains ascending catecholamine fibers that project to the prefrontal cortex (PFC). Damage to these fibers following traumatic brain injury (TBI) may alter extracellular catecholamine levels in the PFC and impede attention and working memory ability. This study investigated white matter microstructure of the medial MFB, specifically the supero-lateral branch (slMFB), following TBI, and its association with performance on attention and working memory tasks. METHOD: Neuropsychological measures of attention and working memory were administered to 20 moderate-severe participants with TBI (posttraumatic amnesia M = 40.05 ± 37.10 days, median time since injury 10.48 months, range 3.72-87.49) and 20 healthy controls. Probabilistic tractography was used to obtain fractional anisotropy (FA) and mean diffusivity (MD) values for 17 participants with TBI and 20 healthy controls. RESULTS: When compared to controls, participants with TBI were found to have significantly lower FA (p < .001) and higher MD (p < .001) slMFB values, and they were slower to complete tasks including Trail Making Task-A, Hayling, selective attention task, n-back, and Symbol Digit Modalities Test. CONCLUSION: This study was the first to demonstrate microstructural white matter damage within the slMFB following TBI. However, no evidence was found for an association of alterations to this tract and performance on attentional tasks.


Assuntos
Atenção/fisiologia , Lesões Encefálicas Traumáticas/patologia , Lesões Encefálicas Traumáticas/fisiopatologia , Feixe Prosencefálico Mediano/patologia , Memória de Curto Prazo/fisiologia , Substância Branca/patologia , Adulto , Lesões Encefálicas Traumáticas/diagnóstico por imagem , Imagem de Tensor de Difusão , Feminino , Humanos , Masculino , Feixe Prosencefálico Mediano/diagnóstico por imagem , Substância Branca/diagnóstico por imagem , Adulto Jovem
8.
Int J Stroke ; 12(1): 108-113, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27634976

RESUMO

Rationale Cerebral microbleeds seen on brain magnetic resonance imaging are markers of small vessel disease, linked to cognitive dysfunction and increased ischemic and hemorrhagic stroke risk. Observational studies suggest that aspirin use may induce cerebral microbleeds, and associated overt intracranial hemorrhage, but this has not been definitively resolved. Aims ASPREE-NEURO will determine the effect of aspirin on cerebral microbleed development over three years in healthy adults aged 70 years and over, participating in the larger 'ASPirin in Reducing Events in the Elderly (ASPREE)' primary prevention study of aspirin. Sample size Five hundred and fifty-nine participants provide 75% power (two-sided p value of 0.05) to determine an average difference of 0.5 cerebral microbleed per person after three years. Methods and design A multi-center, randomized placebo-controlled trial of 100 mg daily aspirin in participants who have brain magnetic resonance imaging at study entry, one and three years after randomization and who undergo cognitive testing at the same time points. Study outcomes The primary outcome is the number of new cerebral microbleeds on magnetic resonance imaging after three years. Secondary outcomes are the number of new cerebral microbleeds after one year, change in volume of white matter hyperintensity, cognitive function, and stroke. Discussion ASPREE-NEURO will resolve whether aspirin affects the presence and number of cerebral microbleeds, their relationship with cognitive performance, and indicate whether consideration of cerebral microbleeds alters the risk-benefit profile of aspirin in primary prevention for older people. Trial registration Australian New Zealand Clinical Trials Registry ACTRN12613001313729.


Assuntos
Aspirina/administração & dosagem , Hemorragia Cerebral/epidemiologia , Cognição/efeitos dos fármacos , Fibrinolíticos/administração & dosagem , Acidente Vascular Cerebral/prevenção & controle , Substância Branca/efeitos dos fármacos , Idoso , Aspirina/efeitos adversos , Encéfalo/diagnóstico por imagem , Encéfalo/efeitos dos fármacos , Hemorragia Cerebral/induzido quimicamente , Hemorragia Cerebral/diagnóstico por imagem , Método Duplo-Cego , Fibrinolíticos/efeitos adversos , Humanos , Cooperação Internacional , Imageamento por Ressonância Magnética , Seleção de Pacientes , Medição de Risco , Tamanho da Amostra , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/epidemiologia , Substância Branca/diagnóstico por imagem
9.
J Med Imaging Radiat Oncol ; 59(2): 188-94, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25597382

RESUMO

Diffusion-weighted imaging (DWI) has become an integral part of MRI. Knowledge of the basic principles of DWI and its pitfalls are imperative in the proper application of this technique. We illustrate potential pitfalls of DWI in oncologic imaging.


Assuntos
Artefatos , Erros de Diagnóstico/prevenção & controle , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Neoplasias/patologia , Diagnóstico Diferencial , Humanos , Estadiamento de Neoplasias , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
J Med Imaging Radiat Oncol ; 58(4): 439-48, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24935089

RESUMO

INTRODUCTION: Prostate cancer is common and may be treated immediately or managed conservatively by observation. We sought to determine how reliable multiparametric MRI is in the detection of intraprostatic prostate cancer and what role it has in risk stratification. METHODS: The histology from 38 whole mount prostate specimens was compared with preoperative multiparametric 3T MRI studies with an endorectal receiver coil in place. T1-weighted, T2-weighted, diffusion (b values 50 400 800), perfusion (Ve , Kep , Ktrans , area under the curve) and proton spectroscopic sequences were used. RESULTS: For cancers greater than 0.5 cc, the detection rate for combined T2-weighted imaging and diffusion-weighted imaging (DWI) was 85%. For cancers 0.1 cc-0.5 cc, the sensitivity was 52%.Per patient, false positive rate was 50% for combined T2-weighted imaging and DWI. Perfusion imaging had a sensitivity of 70% for tumours greater than 0.5 cc but had a per patient false positive rate of 80% influenced by benign prostatic hypertrophy. In only 15 patients could a satisfactory spectroscopy study be obtained. Weak correlation was found between the Gleason score and tumour size (r = 0.51), apparent diffusion coefficient (ADC) (r = -0.30) and (choline + creatine)/citrate ratio (r = 0.41). CONCLUSION: T2-weighted imaging and DWI in combination were the best strategy for detecting prostate cancer and had a sensitivity of 85% for detecting lesions greater than 0.5 cc. At 3T, an ADC threshold of between 1100-1200.10(-6) mm(2) /s was optimal for diagnosing prostate cancer. There are significant limitations in the use of perfusion and spectroscopy to detect prostate cancer. Magnetic resonance imaging-targeted or guided biopsy post-MRI imaging is likely to be needed in some patients to assist risk stratification.


Assuntos
Biomarcadores Tumorais/metabolismo , Colina/metabolismo , Creatina/metabolismo , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/metabolismo , Adulto , Idoso , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Espectroscopia de Prótons por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
J Neurotrauma ; 30(24): 2038-50, 2013 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-23952803

RESUMO

The development and utilization of newer neuroimaging modalities provides the capability to more accurately detect the extent of pathology after TBI. The current study examined the ability of susceptibility-weighted imaging (SWI) to detect lesions after TBI as well as the relationship to subsequent clinical outcome. The performance of SWI was compared to that of fluid-attenuated inversion recovery (FLAIR). This study comprised 79 individuals with mild-to-severe TBI, 38 of whom completed neuropsychological tests of attention, working memory, processing speed, memory, and executive functions. SWI was found to quantify a greater lesion volume over the entire brain, specifically in frontal, central, limbic, subcortical gray, and parietal brain regions, than did FLAIR. Moreover, SWI was able to identify TBI-related lesions in almost one third of patients for whom FLAIR was unable to detect any lesions. Greater overall SWI volume, as well as frontal SWI volume, was found to relate to the severity of TBI. Conversely, no association was found between FLAIR lesion volume and injury severity. In addition, there was some evidence that higher lesion volume, for both SWI and FLAIR, were associated with poorer memory as well as processing speed impairment. This study suggests that SWI may provide additional sensitivity in the detection of lesions after TBI. Consequently, this imaging sequence may provide a more accurate representation of the severity of individuals' injuries and their subsequent neuropsychological outcomes.


Assuntos
Lesões Encefálicas/diagnóstico , Lesões Encefálicas/terapia , Adolescente , Adulto , Idoso , Lesões Encefálicas/epidemiologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Interpretação de Imagem Assistida por Computador/normas , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem
12.
J Med Imaging Radiat Oncol ; 57(1): 1-7, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23374546

RESUMO

The written radiology report is the dominant method by which radiologists communicate the results of diagnostic and interventional imaging procedures. It has an important impact on decisions about further investigation and management. Its form and content can be influential in reducing harm to patients and mitigating risk for practitioners but varies markedly with little standardisation in practice. Until now, the Royal Australian and New Zealand College of Radiologists has not had a guideline for the written report. International guidelines on this subject are not evidence based and lack description of development methods. The current guideline seeks to improve the quality of the written report by providing evidence-based recommendations for good practice. The following attributes of the report are addressed by recommendations: Content Clinical information available to the radiologist at the time the report was created Technical details of the procedure Examination quality and limitations Findings (both normal and abnormal) Comparison with previous studies Pathophysiological diagnosis Differential diagnoses Clinical correlation and/or answer to the clinical question Recommendations, particularly for further imaging and other investigations Conclusion/opinion/impression Format Length Format Language Confidence and certainty Clarity Readability Accuracy Communication of discrepancies between an original verbal or written report and the final report Proofreading/editing of own and trainee reports.


Assuntos
Diagnóstico por Imagem/normas , Documentação/normas , Medicina Baseada em Evidências , Guias de Prática Clínica como Assunto , Radioterapia (Especialidade)/normas , Radiologia/normas , Humanos , Internacionalidade
14.
Future Oncol ; 5(8): 1295-306, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19852743

RESUMO

Preoperative staging is now an essential factor in the multidisciplinary management of rectal cancer because tumor stage is the strongest predictive factor for recurrence. Preoperative staging of rectal cancer can be divided into either local or distant staging. Local staging incorporates the assessment of mural wall invasion, circumferential resection margin involvement, as well as the nodal status for metastasis. Distant staging assesses for evidence of metastatic disease. The aim of this review is to consider the indications and limitations of the current preoperative imaging modalities for rectal cancer staging including clinical examination, endorectal ultrasound, magnetic resonance imaging, computed tomography and positron emission tomography-computed tomography, with respect to local and distant disease.


Assuntos
Estadiamento de Neoplasias/métodos , Cuidados Pré-Operatórios/métodos , Neoplasias Retais/patologia , Endossonografia , Humanos , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X
16.
AJR Am J Roentgenol ; 188(5): 1388-94, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17449787

RESUMO

OBJECTIVE: The purpose of this study was to ascertain current MRI safety practices in Australia regarding permanent pacemakers, temporary pacing wires, cerebral aneurysm clips, implants of unknown MRI safety status, and use of metal detectors, with respect to adherence to published guidelines. MATERIALS AND METHODS: A questionnaire was distributed to more than 100 MRI facilities in Australia. RESULTS: Ninety-two responses, representing 102 MRI systems, were received. Respondents from approximately one in 15 sites were aware they had inadvertently imaged a patient who had a permanent pacemaker (eight patients). One of these episodes led to a death. Use of modified request forms, on which referring physicians are asked for MRI safety information, was incomplete (48/90 facilities). Four facilities deliberately imaged pacemaker patients. Seventy-seven of 89 facilities responded that they do not image patients with temporary pacing wires. Aneurysm clips were accepted by most sites (71/91), and only one site associated with a neurosurgical service refused such patients. Seventy of 71 facilities required written identification of the clip type. Most (77/90) of the sites reported delays due to the unknown MRI safety status of implants. Only four of 92 sites reported routine use of a metal detector. The guidelines of the American College of Radiology and of the Royal Australian and New Zealand College of Radiologists were equally influential (38% each). Only 10 of 90 respondents reported use of external audits of safety processes. CONCLUSION: Ongoing vigilance is required for avoiding MRI of patients with pacemakers, particularly when information from the patient is unreliable or unobtainable. Requiring referring physicians to provide MRI safety information may help to minimize risk.


Assuntos
Imageamento por Ressonância Magnética , Segurança , Austrália , Pesquisas sobre Atenção à Saúde , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Marca-Passo Artificial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...