Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Prosthet Dent ; 128(4): 688-694, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33750574

RESUMO

STATEMENT OF PROBLEM: Although the 2D analysis of prosthesis cementation space has been popular, its correlation with volumetric comparison (3D data) of cement space is unclear. PURPOSE: The purpose of this in vitro study was to evaluate the cement space in computer-aided design and computer-aided manufacturing (CAD-CAM) crowns of different materials and correlate 2D measurements of cement space with their corresponding 3D values (volume of cement space) by using microcomputed tomography (µCT) analysis of regions of interest. MATERIAL AND METHODS: Ten molar crowns were milled in lithium disilicate (LD), resin nanoceramic (RN), and zirconia (Z) ceramics. Silicone replicas were produced and used as the analog cement layer and scanned with a desktop X-ray microfocus CT scanner. Twenty-eight slices were evaluated in 3 regions: marginal, axial, and occlusal (n=84 measurement points/specimen). After 3D reconstruction of the cement space, the volume was calculated. Data were statistically evaluated through 2-way ANOVA and Bonferroni test (α=.05). The Pearson correlation test was used to investigate the correlation between the 2D and 3D data. RESULTS: The volumes of the occlusal (LD 10 ±1 mm3; RN 9 ±1 mm3) and axial regions (LD 9 ±2 mm3; RN 8 ±1 mm3) were significantly higher than the volume of the marginal region for LD and RN specimens (LD 6 ±2 mm3; RN 4 ±1 mm3) (both P<.001). For the Z group, the axial region had the highest volume (19 ±2 mm3), followed by the volumes of the occlusal (15 ±1 mm3) and marginal regions (12 ±1 mm3). The Pearson correlation test determined a moderate positive correlation of the marginal area (r=0.606, P<.001) and of the axial region (r=0.588, P<.001). However, a moderate negative correlation was found between volume and thickness of the occlusal area (r=-0.437, P=.016). CONCLUSIONS: Z showed more volume of cement space, as well as thicker cement space than LD and RN. The µCT analysis is an efficient method of analyzing cement thickness and volume in ceramic crowns at the selected regions of interest. A moderate positive correlation was found between the 2D and 3D analyses for the axial and marginal regions of ceramic crowns.


Assuntos
Adaptação Marginal Dentária , Planejamento de Prótese Dentária , Microtomografia por Raio-X , Coroas , Desenho Assistido por Computador , Porcelana Dentária , Materiais Dentários , Cerâmica , Cimentos Dentários/uso terapêutico , Cimentos de Ionômeros de Vidro
2.
J Prosthodont ; 30(8): 690-697, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33245170

RESUMO

PURPOSE: To evaluate the fatigue survival, fracture loads and failure modes of monolithic lithium disilicate screw-retained crowns, attached to titanium insert, and cement-retained crowns. MATERIALS AND METHODS: Internal tapered connection implants, embedded in acrylic resin at 30° inclination, were restored with lithium disilicate restorations, simulating a maxillary premolar (n = 20), with different designs: screw-retained titanium base abutment-crowns, and cement-retained crowns. The specimens were submitted to cyclic mechanical loading (1.2 × 106 cycles with a load of 0-250 N at 2 Hz). Surviving specimens were subjected to single load to fracture in a universal testing machine and failure modes were determined with the aid of an optical microscope. Maximum load values were analyzed statistically using the t-test and differences in failure modes were analyzed using the chi-squared test (α = 0.05). RESULTS: All specimens survived the cyclic mechanical loading. Fracture load was significantly higher for screw-retained crowns (821.69 ±196.71 N) than the cement-retained crowns (577.03 ± 137.75 N) (p = 0.005). Ceramic failure was the predominant mode, with no statistical difference between groups. CONCLUSIONS: Screw-retained and cement-retained lithium disilicate crowns survived the cyclic mechanical loading. The use of titanium inserts to support a monolithic restoration enhances the fracture strength of the crown/abutment system.


Assuntos
Implantes Dentários , Falha de Restauração Dentária , Parafusos Ósseos , Cerâmica , Coroas , Porcelana Dentária , Análise do Estresse Dentário , Teste de Materiais , Zircônio
3.
Eur J Dent ; 14(S 01): S14-S19, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32882738

RESUMO

OBJECTIVE: This survey aimed to assess the effects of coronavirus disease 2019 (COVID-19) on elective and urgency/emergency dental care and dentists concerned. MATERIALS AND METHODS: A web-based survey was performed using Google forms questionnaire sent to dentists in Brazil. Questions included: personal information, type of dental care provided during quarantine, if emergencies increased, the dental office biosafety routine, among others. The levels of concern about the impact of quarantine on dental care and patient oral health conditions and the economic impact on dental practices were evaluated using a 0- to 10-point scale. Statistical analysis included descriptive, percentages, one-way ANOVA, Tukey, and chi-square tests. RESULTS: During quarantine, 64.6% of the dentists attended only urgency/emergency treatments, while 26.1% maintained routine appointments, and 9.3% closed the dental offices. A higher percentage of dentists from the least affected states continued routine dental treatment; dentists were younger and presented a significantly lower level of concern about dental treatments and oral health conditions of their patients. An increase in urgency/emergency procedures was reported by 44.1% of the dentists, mostly due to the unavailability of routine/elective dental care and increased patient anxiety and stress. The main causes of urgency/emergency appointments were toothache, dental trauma, and broken restorations, besides the breakage of orthodontic appliances and temporomandibular disorders. Dentists reported a high level of concern about the economic impact caused by quarantine. CONCLUSIONS: The pandemic/quarantine has negatively affected the clinical routine. Personal protection/hygiene care must be adopted and reinforced by dental professionals/staff to make dental procedures safer.

4.
Eval Health Prof ; 43(3): 201-203, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32608250

RESUMO

This survey aimed to assess the concerns of students of health-related higher education in Brazil regarding distance learning during the coronavirus pandemic. A Google Forms anonymous questionnaire was sent by WhatsApp Messenger to students at a private university. Seven hundred and four students answered the questionnaire (566 female, 138 male, mean age = 23.09 years), reflecting approximately a third of the students in health-related disciplines. Students reported feeling anxious due to the pandemic. Most of the students agreed with having the ability to continue education through distance learning, but relatively few of them enjoyed it. Also, students were concerned that learning of clinical material and professional training would be impaired, and they were afraid of failing the year of education. Health-related higher education private institutions in Brazil should focus on reassessing and prioritizing their policies and protocols and include a detailed plan for the future.


Assuntos
Atitude Frente a Saúde , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/psicologia , Educação a Distância , Pneumonia Viral/epidemiologia , Pneumonia Viral/psicologia , Estudantes/psicologia , Brasil/epidemiologia , COVID-19 , Feminino , Humanos , Masculino , Pandemias , Inquéritos e Questionários , Universidades , Adulto Jovem
5.
J Prosthet Dent ; 124(1): 87.e1-87.e6, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32238276

RESUMO

STATEMENT OF PROBLEM: Identical computer-aided design (CAD) parameters may be used to mill a variety of ceramic materials for computer-aided design and computer-aided manufacture (CAD-CAM) crowns. Whether milled crown spacing matches the designed parameters when more than a single evaluation method is applied is unknown. PURPOSE: The purpose of this in vitro study was to correlate the stereomicroscope and the microcomputer tomography (µCT) 2-dimensional analysis of the cementation space with the replica technique in assessing 3 different ceramic materials. MATERIAL AND METHODS: The specimens were milled in lithium disilicate, resin nanoceramic, and zirconia (n=30). The cement space was measured at the marginal, axial, and occlusal regions. One hundred twenty measurements of each material were used to correlate the methodologies. Data were statistically evaluated with 2-way repeated measures ANOVA and the Tukey test (α=.05). The Pearson correlation coefficient was used for each region for both methodologies (µCT and optical microscopy) separately. RESULTS: For the µCT analysis, no differences were observed (P>.05) among the materials, but the axial region showed a positive correlation with the marginal (r=0.957) and occlusal regions (r=0.349); the same was observed between the occlusal and marginal regions (r=0.338). However, for stereomicroscope evaluation, resin nanoceramic and zirconia present similar cementation space (P=960), both being different from lithium disilicate (P<.05). The marginal region presented a positive correlation with axial (r=0.149) and occlusal regions (r=0.344), but the axial region showed negative correlation with the occlusal surface (r=-0.205). CONCLUSIONS: The measurements of the scanned replicas were accurate when thinner sections were under measurement. Although the same space parameters were set in the CAD software program, definitive internal dimensions varied among the milled crowns.


Assuntos
Cimentação , Adaptação Marginal Dentária , Cerâmica , Desenho Assistido por Computador , Coroas , Porcelana Dentária , Planejamento de Prótese Dentária
6.
J Appl Oral Sci ; 27: e20180297, 2019 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-31166548

RESUMO

INTRODUCTION: Polymer-based composite materials have been proposed as an alternative for single unit restorations, due to their resilient and shock absorbing behavior, in contrast to the brittleness of ceramic materials that could result in failure by fracture. OBJECTIVE: To evaluate the fatigue strength and damage modes of monolithic posterior resin nanoceramic and lithium disilicate glass ceramic crowns. METHODOLOGY: Twenty-six resin nanoceramic (RNC) and lithium disilicate glass ceramic (LD) 2 mm monolithic crowns (n=13) were cemented on composite resin replicas of a prepared tooth and subjected to cyclic load with lithium disilicate indenters for 2 million cycles. Specimens and indenters were inspected every 500,000 cycles and suspended when presenting fractures or debonding. Surviving specimens were embedded in epoxy resin, polished and subsurface damage was analyzed. Specimens presenting fractures or severe subsurface damage were considered as failures. Survival data was subjected to Fisher's exact test; damage modes were subjected to Mann-Whitney test (p<0.05). RESULTS: There were no debonding, cohesive or catastrophic failures. Considering subsurface damage, 53.8% of RNC and 46.2% of LD crowns survived the fatigue test, presenting no statistical difference. Chief damage modes were radial cracks for RNC and inner cone cracks for LD, presenting no statistical difference. CONCLUSIONS: The results suggest that if debonding issues can be resolved, resin nanoceramic figures can be an alternative to posterior crowns. Although distinct, damage modes revealed potential to cause bulk fracture in both glass ceramic and resin nanoceramic crowns.


Assuntos
Cerâmica/química , Coroas , Porcelana Dentária/química , Cimentos de Resina/química , Desenho Assistido por Computador , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Desgaste de Restauração Dentária , Restauração Dentária Permanente/métodos , Análise do Estresse Dentário , Humanos , Teste de Materiais , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Propriedades de Superfície , Fatores de Tempo
7.
J. appl. oral sci ; 27: e20180297, 2019. graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1012517

RESUMO

Abstract Polymer-based composite materials have been proposed as an alternative for single unit restorations, due to their resilient and shock absorbing behavior, in contrast to the brittleness of ceramic materials that could result in failure by fracture. Objective: To evaluate the fatigue strength and damage modes of monolithic posterior resin nanoceramic and lithium disilicate glass ceramic crowns. Methodology: Twenty-six resin nanoceramic (RNC) and lithium disilicate glass ceramic (LD) 2 mm monolithic crowns (n=13) were cemented on composite resin replicas of a prepared tooth and subjected to cyclic load with lithium disilicate indenters for 2 million cycles. Specimens and indenters were inspected every 500,000 cycles and suspended when presenting fractures or debonding. Surviving specimens were embedded in epoxy resin, polished and subsurface damage was analyzed. Specimens presenting fractures or severe subsurface damage were considered as failures. Survival data was subjected to Fisher's exact test; damage modes were subjected to Mann-Whitney test (p<0.05). Results: There were no debonding, cohesive or catastrophic failures. Considering subsurface damage, 53.8% of RNC and 46.2% of LD crowns survived the fatigue test, presenting no statistical difference. Chief damage modes were radial cracks for RNC and inner cone cracks for LD, presenting no statistical difference. Conclusions: The results suggest that if debonding issues can be resolved, resin nanoceramic figures can be an alternative to posterior crowns. Although distinct, damage modes revealed potential to cause bulk fracture in both glass ceramic and resin nanoceramic crowns.


Assuntos
Humanos , Cerâmica/química , Cimentos de Resina/química , Coroas , Porcelana Dentária/química , Propriedades de Superfície , Fatores de Tempo , Teste de Materiais , Reprodutibilidade dos Testes , Planejamento de Prótese Dentária , Desenho Assistido por Computador , Estatísticas não Paramétricas , Falha de Restauração Dentária , Desgaste de Restauração Dentária , Restauração Dentária Permanente/métodos , Análise do Estresse Dentário
8.
Gen Dent ; 63(4): e6-10, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26147178

RESUMO

The objective of this study was to investigate the influence of educational materials on the denture hygiene and utilization habits of 70 adult volunteers who had been using complete dentures for at least 5 years. On the day they received new dentures, 32 patients were provided with an illustrated leaflet and verbal instructions on oral hygiene and utilization habits, while the remaining 38 participants were advised to continue cleaning and wearing their new dentures as they had their previous dentures. After a 6- to 10-week period, 66 of 70 subjects were interviewed about socioeconomic factors, denture hygiene, and utilization habits. The percentage of patients with a proper denture care routine was low in both groups, suggesting that patients had a tendency not to change old habits. However, statistical analysis showed a positive correlation between receiving instruction and performing denture care in a way that is closer to the recommended method: brushing without toothpaste, using a specific brush; soaking in a sodium hypochlorite solution; and removing the prosthesis at night. Within the limitations of this study, it was concluded that this approach to patient education could be applied to improve the hygiene and utilization habits of denture wearers as well as encourage the correct use of complete dentures.


Assuntos
Dentaduras , Higiene Bucal/educação , Educação de Pacientes como Assunto/métodos , Idoso , Higienizadores de Dentadura/uso terapêutico , Dentaduras/psicologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Higiene Bucal/estatística & dados numéricos , Materiais de Ensino
9.
Acta sci., Health sci ; 37(1): 77-83, Jun. 22, 2015. tab, ilus
Artigo em Inglês | LILACS | ID: biblio-832153

RESUMO

Appropriate hygiene of dentures contributes to the maintenance of oral and systemic health. However, most of denture wearers had never been instructed on how to perform daily oral/denture care. The purpose of this study is to investigate the influence of a guidance material associated or not to the provision of hygiene devices and its effect on the habits of denture wearers. Forty- eight complete denture wearers were randomly divided into three groups. Group N received no guidance on how to clean and wear their dentures, group G received an illustrated leaflet and verbal complementary instructions and group GK received the same guidance as group G and a hygiene kit for denture cleaning. After a six to ten week period they responded to a 'hygiene and wearing habits' questionnaire. Chi-square test was used for statistical analysis considering p < 0.05. Brushing was the most frequent cleaning method, the majority of groups N and G used toothpaste. Participants of group G and GK presented low percentages of individuals with hygiene and wearing routine considered improper. The differences between groups in hygiene and wearing routine were statistically significant (p < 0.001). The proposed guidance material yielded better results when associated to provision of hygiene devices for denture cleaning.


O objetivo deste estudo é investigar a influência de um material de orientação de higiene, associado ou não à distribuição de dispositivos de higiene, nos hábitos de portadores de próteses totais. Quarenta e oito voluntários foram divididos em três grupos. O grupo N não recebeu orientação sobre higienização de próteses. O grupo G recebeu um folheto ilustrado e orientações verbais. O grupo GK recebeu orientações similares as do grupo G e um conjunto de dispositivos para higiene de próteses. Após seis a dez semanas, os voluntários responderam um questionário sobre hábitos de higiene e uso das próteses. A análise estatística foi realizada através do teste qui- quadrado, considerando p < 0.05. A escovação foi o método de higienização mais utilizado, e a maioria dos voluntários dos grupos N e G utilizaram creme dental. Um baixo percentual de participantes do grupo G e GK apresentaram uma rotina de higienização e uso considerada imprópria. Houve diferença estatisticamente significante entre os grupos para a rotina de higienização e uso (p < 0,001). O material de orientação de higiene proposto neste estudo apresentou melhores resultados quando associado à distribuição de dispositivos de higiene.


Assuntos
Humanos , Masculino , Feminino , Higiene Bucal , Educação em Saúde Bucal , Prótese Dentária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...