Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 2470-2473, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31946398

RESUMO

The incidence and prevalence of cardiovascular diseases (CVD) is increasing which is partly due to an increase in unhealthy lifestyles, including lack of physical activity. Therefore, following a cardiovascular event, patients are encouraged to participate in a supervised exercise-based cardiac rehabilitation (CR) program. However, uptake rates of these programs are low and compliance to adequate volumes of physical activity after the completion of such programs are even lower. An approach that has been proposed towards the increase of patient adherence to exercise, is the incorporation of technology-enabled solutions which are applied at patient's homes. However, different factors may affect patient engagement with such alternative solutions. In this work, we use diverse types of data, including baseline characteristics of the patient (i.e. physiological, behavioral, demographical data) as well as usage data of a tele-rehabilitation solution during a 4-week familiarization period, in order to predict the compliance of patients with CVD to a technology-supported physical activity intervention after completion of a supervised exercise program. Patients were clustered based on their use of a technology intervention during a previously conducted study. Following a feature selection approach, a support vector machine was trained to classify patients as adherent or non-adherent to the intervention. The performance of the classifier was assessed by means of the receiving operator curve (ROC). Bio-psycho-social baseline variables predicted adherence with a ROC of 0.86, but adding usage data of the platform during a 4-week familiarization period increased the ROC up to 0.94. Furthermore, the high sensitivity values (83.8% and 95.5% respectively) support the strength of the models to identify those patients with CVD that will be adherent to a technology-enabled, home-based CR program.


Assuntos
Reabilitação Cardíaca , Terapia por Exercício , Cooperação do Paciente , Telerreabilitação , Exercício Físico , Previsões , Humanos
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 5002-5005, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31946983

RESUMO

Obstructive sleep apnea (OSA) is an increasingly prevalent sleep disorder with estimated prevalence of moderate to severe sleep apnea ranging between 6-13% in the adult population. Nocturnal intermittent hypoxia has been associated with an increased risk of developing type 2 diabetes and insulin resistance (IR). The existing indices of hypoxia, used in polysomnography (PSG), cannot express accurately the influence of the mild desaturations precisely during sleep. In the present study, 73 subjects without other comorbidities were examined by PSG. Hypoxia parameters were analyzed, in the intervals with low values of SpO2 signal. The thresholds were set at 94% and 92% and the average value (M) of the SpO2 signal, in areas below thresholds, were calculated. The desaturations were analyzed together with their duration within the recording in terms of SpO2 signal parameters. Blood samples were taken for biochemical analysis. A total of 50 subjects were diagnosed with OSAS with mean AHI of 56.11±27.70/h and 23 subjects had no sleep apnea with mean AHI of 3.47±0.6/h. The amount of desaturations was significantly correlated with insulin levels (r=0.301, p=0.034) and the percentage of desaturation events (Dev) that were longer than 6 points (2 sec) (r=0.301, p=0.034). In addition, mean duration of desaturations was significantly correlated with IR as expressed by HOMA index (r=0.289, p=0.047), as well as with total duration of desaturation of SpO2 (r=0.322, p =0.025) and percentage of Dev that were long than 6 points (2 sec) (r=0.292, p=0.044). A strong correlation was also revealed between total duration of desaturations and fasting glucose (r=0.887, p=0.000). Results suggest that hypoxia parameters derived from SpO2 signal analysis, are strongly correlated with IR and fasting glucose levels, implying a role of hypoxia in the pathogenesis of diabetes.


Assuntos
Diabetes Mellitus Tipo 2 , Resistência à Insulina , Oxigênio , Estado Pré-Diabético , Apneia Obstrutiva do Sono , Adulto , Humanos , Hipóxia/diagnóstico , Oxigênio/sangue , Apneia Obstrutiva do Sono/diagnóstico
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 2500-2503, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28324967

RESUMO

Advancing Care Coordination and Telehealth Deployment (ACT) is a European Union (EU) project, completed last October, which has developed a framework for evaluating and improving pioneering health care programs regarding coordinating care and telehealth (CC & TH) across specific EU regions. In this paper we present the key design decisions of the project's data model and the challenges faced. We focus on the definition of the multi-dimensional indicators in order to overcome data incompleteness and heterogeneity issues. Finally, we also suggest a graph based approach that could facilitate development of such data models in similar projects.


Assuntos
União Europeia , Projetos de Pesquisa , Telemedicina , Atenção à Saúde , Humanos , Modelos Teóricos
4.
Artigo em Inglês | MEDLINE | ID: mdl-24110557

RESUMO

Atrial Fibrillation (AF) is a condition in which heart rhythm is not associated with normal sinoatrial (SA) node pacemaker but it derives from different areas on the atrium, often from the area of Pulmonary veins (PVs) A way to eliminate the influence of PVs in the inducement of AF is the PVs isolation surgery. In this study, an effort is made towards investigating the morphology and dynamics of P-waves, when the potentially arrhythmogenic tissue in PVs is involved or isolated via ablation. For this reason, 20 patients who were subjected to PVs isolation were studied, via vectrorcardiography recordings obtained before and after the ablation. Wavelet energies for five frequency bands were analyzed, using a two dimensional representation. The proposed technique was applied for the analysis of wavelet energies in consecutive beats, and their correlation with the RR interval. Features for the evaluation of those plots were extracted, such as the axes of a fitted to the plot ellipse and the center of the mass. The statistical analysis demonstrated significant differences between the groups, which imply the modification of the atrial substrate concerning electrical conduction toward to a more stable condition.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Átrios do Coração/fisiopatologia , Humanos , Veias Pulmonares/fisiopatologia , Veias Pulmonares/cirurgia , Curva ROC , Nó Sinoatrial/fisiopatologia , Análise de Ondaletas
5.
Artigo em Inglês | MEDLINE | ID: mdl-23367386

RESUMO

Atrial fibrillation (AF) is one of the most common cardiac arrhythmia. Electrical properties of the atrial myocardium may be related to the appearance of this type of arrhythmia. However ectopic beats, occurring normally in healthy people, disturb cardiac rhythm. Those beats arise from fiber outside the region of SA node. With this work we aim at highlighting differences in the atrial activity between healthy subjects, healthy subjects presenting many ectopic events and patients with AF. The X-Y-Z leads of vectorcardiography recordings are considered. Wavelet-based parameters are extracted from a window which represents atrial activity originated from SA node and compared between signals of the three groups. Results show differences potentially related to the conduction system of the atrium between healthy people and people with AF, as well as between healthy people and people with ectopic events. No difference was found from the analysis of SA node beats between people with AF and healthy with ectopic events.


Assuntos
Fibrilação Atrial/fisiopatologia , Ecocardiografia/métodos , Estudos de Casos e Controles , Humanos
6.
Artigo em Inglês | MEDLINE | ID: mdl-22254469

RESUMO

Atrial fibrillation (AF) is a complex phenomenon, related with a multitude of factors, including the electrical properties of the atrial substrate. The purpose of this work is to present a method that highlights electrocardiographic differences between normal subjects and patients with paroxysmal AF episodes (PAF), potentially related with substrate differences. Vectorcardiography recordings are considered and, for each lead (X-Y-Z), on a beat by beat basis, a steady window before QRS, corresponding to the atrial activity, is analysed via continuous wavelet transform. Wavelet-based parameters are calculated and compared between the normal and AF group, with the beat to beat variation of wavelet energy as the most important feature showing a significantly higher variability in the AF group.


Assuntos
Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Diagnóstico por Computador/métodos , Frequência Cardíaca , Vetorcardiografia/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Análise de Ondaletas
8.
Ann Clin Lab Sci ; 25(4): 297-305, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-7668814

RESUMO

Alterations in magnesium (Mg) homeostasis during and after orthotopic liver transplantation are common. The purpose of this study is to compare total Mg (TMg), calculated ionized Mg (cMg++) and measured ionized Mg (mMg++) during and immediately following liver transplantation. The newly developed first generation ion selective electrode analyzer, AVL 988-4, was used to measure mMg++ in 63 serum samples from 3 transplant recipients and 48 serum samples from 48 healthy volunteers. Analysis was divided into intraoperative (stages 1 to 3) and postoperative periods. Decreased TMg, cMg++ and mMg++ levels were observed intraoperatively and > 2 weeks postoperatively. The cMg++ levels were consistently higher than mMg++, presumably owing to the fact that the equation used for the calculation does not take complex-Mg++ into account. A better correlation was observed between mMg++ and cMg++ in the transplant group (r = 0.87 to 0.99) compared to controls (r = 0.74). The usefulness of direct measurement of Mg++ in liver transplantation remains to be determined.


Assuntos
Transplante de Fígado , Magnésio/sangue , Adulto , Cátions Bivalentes , Humanos , Concentração de Íons de Hidrogênio , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Análise de Regressão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...