Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
G Ital Cardiol (Rome) ; 24(8): 661-664, 2023 08.
Artigo em Italiano | MEDLINE | ID: mdl-37492874

RESUMO

We here describe the case of an 84-year-old woman with a history of ischemic heart disease, paroxysmal atrial fibrillation, and severe aortic stenosis, admitted to the coronary care unit of our hospital for an ST-elevation myocardial infarction secondary to in-stent thrombosis and treated with primary percutaneous coronary intervention. On admission, the patient was on chronic therapy with apixaban for atrial fibrillation, and reported no history of bleeding. However, the day after the administration of the loading doses of aspirin and clopidogrel, the patient developed multiple episodes of rectal bleeding and melena, requiring blood transfusions. The endoscopic work-up was negative for bleeding lesions in the upper gastrointestinal tract and in the colon, but with a blood leakage from the ileocecal valve, prompting the diagnostic suspicion of an ileal bleeding secondary to angiodysplasia. Considering the well-known link between severe aortic stenosis and ileal angiodysplasia (i.e. Heyde's syndrome), the patient, already in the waiting list for elective transcatheter aortic valve implantation, underwent the procedure during the index hospitalization. The procedure was performed in the absence of complications and the patient was discharged with a personalized antithrombotic therapy. In the following weeks, no further episodes of bleeding were reported.


Assuntos
Angiodisplasia , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Idoso de 80 Anos ou mais , Feminino , Angiodisplasia/complicações , Angiodisplasia/cirurgia , Infarto do Miocárdio , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Resultado do Tratamento
2.
Sci Rep ; 12(1): 19800, 2022 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-36396773

RESUMO

Random walks are common in nature and are at the basis of many different phenomena that span from neutrons and light scattering to the behaviour of animals. Despite the evident differences among all these phenomena, theory predicts that they all share a common fascinating feature known as Invariance Property (IP). In a nutshell, IP means that the mean length of the total path of a random walker inside a closed domain is fixed by the geometry and size of the medium. Such a property has been demonstrated to hold not only in optics, but recently also in the field of biology, by studying the movement of bacteria. However, the range of validity of such a universal property, strictly linked to the fulfilment of equilibrium conditions and to the statistical distributions of the steps of the random walkers, is not trivial and needs to be studied in different contexts, such as in the case of biological entities occupied in random foraging in an open environment. Hence, in this paper the IP in a virtual medium inside an open environment has been studied by using actual movements of animals recorded in nature. In particular, we analysed the behaviour of a grazer mollusc, the chiton Acanthopleura granulata. The results depart from those predicted by the IP when the dimension of the medium increases. Such findings are framed in both the condition of nonequilibrium of the walkers, which is typical of animals in nature, and the characteristics of actual animal movements.


Assuntos
Alimentos , Movimento , Animais
3.
J Biomed Opt ; 27(8)2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35445592

RESUMO

SIGNIFICANCE: Code verification is an unavoidable step prior to using a Monte Carlo (MC) code. Indeed, in biomedical optics, a widespread verification procedure for MC codes is still missing. Analytical benchmarks that can be easily used for the verification of different MC routines offer an important resource. AIM: We aim to provide a two-step verification procedure for MC codes enabling the two main tasks of an MC simulator: (1) the generation of photons' trajectories and (2) the intersections of trajectories with boundaries separating the regions with different optical properties. The proposed method is purely based on elementary analytical benchmarks, therefore, the correctness of an MC code can be assessed with a one-sample t-test. APPROACH: The two-step verification is based on the following two analytical benchmarks: (1) the exact analytical formulas for the statistical moments of the spatial coordinates where the scattering events occur in an infinite medium and (2) the exact invariant solutions of the radiative transfer equation for radiance, fluence rate, and mean path length in media subjected to a Lambertian illumination. RESULTS: We carried out a wide set of comparisons between MC results and the two analytical benchmarks for a wide range of optical properties (from non-scattering to highly scattering media, with different types of scattering functions) in an infinite non-absorbing medium (step 1) and in a non-absorbing slab (step 2). The deviations between MC results and exact analytical values are usually within two standard errors (i.e., t-tests not rejected at a 5% level of significance). The comparisons show that the accuracy of the verification increases with the number of simulated trajectories so that, in principle, an arbitrary accuracy can be obtained. CONCLUSIONS: Given the simplicity of the verification method proposed, we envision that it can be widely used in the field of biomedical optics.


Assuntos
Óptica e Fotônica , Fótons , Método de Monte Carlo
4.
Sensors (Basel) ; 22(4)2022 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-35214302

RESUMO

The research in optical sensors has been largely encouraged by the demand for low-cost and less or non-invasive new detection strategies. The invention of the random laser has opened a new frontier in optics, providing also the opportunity to explore new possibilities in the field of sensing, besides several different and peculiar phenomena. The main advantage in exploiting the physical principle of the random laser in optical sensors is due to the presence of the stimulated emission mechanism, which allows amplification and spectral modification of the signal. Here, we present a step forward in the exploitation of this optical phenomenon by a revisitation of a previous experimental setup, as well as the measurement method, in particular to mitigate the instability of the results due to shot-to-shot pump energy fluctuations. In particular, the main novelties of the setup are the use of optical fibers, a reference sensor, and a peristaltic pump. These improvements are devoted to: eliminating optical beam alignment issues; improving portability; mitigating the variation in pump energy and gain medium performances over time; realizing an easy and rapid change of the sensed medium. The results showed that such a setup can be considered a prototype for a portable device for directly measuring the scattering of liquid samples, without resorting to complicated numerical or analytic inversion procedures of the measured data, once the suitable calibration of the system is performed.

5.
Sci Rep ; 11(1): 19486, 2021 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-34593837

RESUMO

In this work, we present a robust and powerful method for the verification, with arbitrary accuracy, of Monte Carlo codes for simulating random walks in complex media. Such random walks are typical of photon propagation in turbid media, scattering of particles, i.e., neutrons in a nuclear reactor or animal/humans' migration. Among the numerous applications, Monte Carlo method is also considered a gold standard for numerically "solving" the scalar radiative transport equation even in complex geometries and distributions of the optical properties. In this work, we apply the verification method to a Monte Carlo code which is a forward problem solver extensively used for typical applications in the field of tissue optics. The method is based on the well-known law of average path length invariance when the entrance of the entities/particles in a medium obeys to a simple cosine law, i.e., Lambertian entrance, and annihilation of particles inside the medium is absent. By using this law we achieve two important points: (1) the invariance of the average path length guarantees that the expected value is known regardless of the complexity of the medium; (2) the accuracy of a Monte Carlo code can be assessed by simple statistical tests. We will show that we can reach an arbitrary accuracy of the estimated average pathlength as the number of simulated trajectories increases. The method can be applied in complete generality versus the scattering and geometrical properties of the medium, as well as in presence of refractive index mismatches in the optical case. In particular, this verification method is reliable to detect inaccuracies in the treatment of boundaries of finite media. The results presented in this paper, obtained by a standard computer machine, show a verification of our Monte Carlo code up to the sixth decimal digit. We discuss how this method can provide a fundamental tool for the verification of Monte Carlo codes in the geometry of interest, without resorting to simpler geometries and uniform distribution of the scattering properties.


Assuntos
Algoritmos , Modelos Teóricos , Método de Monte Carlo , Humanos
6.
Opt Express ; 26(21): 27615-27627, 2018 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-30469824

RESUMO

Optical sensing is a very important method for investigating different kinds of samples. Recently, we proposed a new kind of optical sensor based on random lasing [ Sci. Rep.6, 35225 (2016)], that couples the advantages of stimulated emission in detecting small variations on scattering properties of a sensed material, to the needs of no alteration of the sample under investigation. Here, we present a method to achieve a quantitative measurement of the scattering properties of a material. The results on samples of calibrated microspheres show a dependence of the peak intensity of the emission spectrum on the transport mean free path of the light within the sample, whatever the dimension (down to ≈100 nm of particle diameter) and the concentration of scatterers dispersed in the sensed material. A direct and fast measurement of the scattering properties is obtained by calibration with a well-known and inexpensive reference medium.

7.
Opt Lett ; 42(21): 4498-4501, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29088197

RESUMO

We report experimental results on the propagation temporal characteristics of the precursor in an inhomogeneous sample. The transient behavior of a step-like pulse in an atomic hot medium is two orders of magnitude faster than the radiative broadened case up to now presented in the literature. Moreover, we show the dependence on the resonant or nonresonant condition. Numerical simulations compare favorable to experimental results.

8.
Sci Rep ; 6: 35225, 2016 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-27725755

RESUMO

In a random laser the optical feedback is provided by scattering rather than by an optical cavity. Then, since its emission characteristics are very susceptible to the scattering details, it is a natural candidate for making active sensors to use as a diagnostic tool for disordered media like biological samples. However, the methods reported up to now, requiring the injection of toxic substances in the sample, have the drawback of altering the physical-chemical composition of the medium and are not suitable for in-vivo measurements. Here we present a random laser based sensor that overcomes these problems by keeping gain and diffusion separated. We provide an experimental characterisation of the sensor by using a reference diffusive liquid phantom and we show that, compared to a passive method, this sensor takes advantage of the gain and spectral properties of the random laser principle.

9.
Opt Express ; 22(23): 28566-71, 2014 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-25402098

RESUMO

Causality and special relativity pose an upper limit to the amount of advance that an optical pulse can acquire during a superluminal propagation. Such a limit can be circumvented if the pulse, before entering the superluminal medium, is retarded by letting it propagate under normal dispersion. We present an experimental evidence of this fact by showing that a laser pulse propagating in an atomic vapor, quasi resonant with an inverted transition and in conditions of anomalous dispersion, moves faster if it is previously retarded in a cell containing the same medium with no population inversion. Optical transmission lines often need an amplification stage to overcome the signal attenuation and the unavoidable delay respect to propagation at c; in this paper we tailor such stage to provide also an optical controlled recover of such delay. We believe that our results can open exciting prospects for real-life optical data processing and communication.


Assuntos
Fenômenos Ópticos , Lasers , Luz , Lógica , Fatores de Tempo
10.
Opt Lett ; 31(9): 1298-300, 2006 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-16642091

RESUMO

We present experimental results of enhanced second- and third-harmonic generation efficiency from Fresnel-lensing effects. We obtained enhancement by a factor of 6 in the third-harmonic yield by simply limiting the laser beam with an iris. Higher enhancement factors (up to 16) were obtained with a Fresnel zone plate. The experimental findings are in good agreement with the results of a simple theoretical analysis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...