Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Crit Care Med ; 39(1): 98-104, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20959782

RESUMO

OBJECTIVE: Lung protective ventilation reduces mortality in patients with acute lung injury, but underrecognition of acute lung injury has limited its use. We recently validated an automated electronic acute lung injury surveillance system in patients with major trauma in a single intensive care unit. In this study, we assessed the system's performance as a prospective acute lung injury screening tool in a diverse population of intensive care unit patients. DESIGN: Patients were screened prospectively for acute lung injury over 21 wks by the automated system and by an experienced research coordinator who manually screened subjects for enrollment in Acute Respiratory Distress Syndrome Clinical Trials Network (ARDSNet) trials. Performance of the automated system was assessed by comparing its results with the manual screening process. Discordant results were adjudicated blindly by two physician reviewers. In addition, a sensitivity analysis using a range of assumptions was conducted to better estimate the system's performance. SETTING: The Hospital of the University of Pennsylvania, an academic medical center and ARDSNet center (1994-2006). PATIENTS: Intubated patients in medical and surgical intensive care units. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Of 1270 patients screened, 84 were identified with acute lung injury (incidence of 6.6%). The automated screening system had a sensitivity of 97.6% (95% confidence interval, 96.8-98.4%) and a specificity of 97.6% (95% confidence interval, 96.8-98.4%). The manual screening algorithm had a sensitivity of 57.1% (95% confidence interval, 54.5-59.8%) and a specificity of 99.7% (95% confidence interval, 99.4-100%). Sensitivity analysis demonstrated a range for sensitivity of 75.0-97.6% of the automated system under varying assumptions. Under all assumptions, the automated system demonstrated higher sensitivity than and comparable specificity to the manual screening method. CONCLUSIONS: An automated electronic system identified patients with acute lung injury with high sensitivity and specificity in diverse intensive care units of a large academic medical center. Further studies are needed to evaluate the effect of automated prompts that such a system can initiate on the use of lung protective ventilation in patients with acute lung injury.


Assuntos
Lesão Pulmonar Aguda/diagnóstico , Cuidados Críticos/métodos , Monitorização Fisiológica/instrumentação , Pneumologia/instrumentação , Síndrome do Desconforto Respiratório/diagnóstico , Centros Médicos Acadêmicos , Lesão Pulmonar Aguda/mortalidade , Lesão Pulmonar Aguda/terapia , Automação , Estudos de Coortes , Intervalos de Confiança , Estado Terminal/mortalidade , Estado Terminal/terapia , Diagnóstico Precoce , Eletrônica Médica/instrumentação , Feminino , Mortalidade Hospitalar/tendências , Humanos , Unidades de Terapia Intensiva , Masculino , Estudos Prospectivos , Respiração Artificial/efeitos adversos , Respiração Artificial/métodos , Síndrome do Desconforto Respiratório/mortalidade , Síndrome do Desconforto Respiratório/terapia , Sensibilidade e Especificidade , Análise de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...