Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Radiat Oncol Biol Phys ; 64(1): 205-9, 2006 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-16198505

RESUMO

PURPOSE: To assess the adequacy of nodal coverage of "conventional" pelvic radiation fields for carcinoma of the cervix, with contoured pelvic vessels on simulation computed tomography (CT) as surrogates for lymph node location. METHODS AND MATERIALS: Pelvic arteries were contoured on non-contrast-enhanced CT simulation images of 43 patients with cervix cancer, FIGO Stages I-III. Vessel contours were hidden, and conventional pelvic fields were outlined: (1) anterior/posterior fields (AP): superior border, L5-S1 interspace; inferior border, obturator foramina; lateral border, 2 centimeters lateral to pelvic brim. (2) Lateral fields (LAT): Anterior border, symphysis pubis; posterior border, S2-S3 interspace. Distances were measured between the following: (1) bifurcation of the common iliac artery and superior border, (2) external iliac artery and lateral border of the AP field, and (3) external iliac artery and anterior border of the LAT field. The distances were considered as "inadequate" if <15 mm, "adequate" if 15-20 mm, and "generous" if >20 mm. RESULTS: Superiorly, 34 patients (79.1%) had inadequate coverage. On the AP, margins were generous in 19 (44.2%), but inadequate in 9 (20.9%). On the LAT, margins were inadequate in 30 (69.8%) patients. Overall, 41 (95.4%, CI, 84.2%-99.4%) patients had at least 1 inadequate margin, the majority located superiorly. Twenty-four (55.8%; CI, 39.9%-70.9%) patients had at least 1 generous margin, the majority located laterally on the AP field. CONCLUSION: Conventional pelvic fields based on bony landmarks do not provide optimal lymph node coverage in a substantial proportion of patients and may include excess normal tissue in some. CT simulation with vessel contouring as a surrogate for lymph node localization provides more precise and individualized field delineation.


Assuntos
Linfonodos/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Estudos de Viabilidade , Feminino , Humanos , Artéria Ilíaca/diagnóstico por imagem , Ossos Pélvicos/diagnóstico por imagem , Pelve , Neoplasias do Colo do Útero/irrigação sanguínea
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...