Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 62(7): 1327-1338, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38549258

RESUMO

OBJECTIVES: Primidone is an anticonvulsive drug used in the treatment of epilepsy and essential tremor. It offers beneficial effects in controlling seizures, but its usage is also associated with possible side effects. To ensure optimal therapy, it is crucial to measure its concentration through accurate quantification methods. Therefore, our main goal was to develop and validate a new reference measurement procedure (RMP) for accurately measuring primidone levels in human serum and plasma. METHODS: In our study, we focused on the separation of primidone from both known and unknown interferences using a C18 column. To achieve accurate sample preparation, we developed a protocol involving protein precipitation followed by a high dilution step. The validation of the assay and determination of measurement uncertainty were carried out following guidelines from organizations such as the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the Expression of Uncertainty in Measurement. These rigorous validation processes ensure the reliability and accuracy of our method for quantifying primidone levels in human serum and plasma samples. RESULTS: The RMP was shown to be highly selective and specific, with no evidence of matrix interference. It can be used to quantify primidone in the range of 0.150-30.0 µg/mL. Intermediate precision was less than 4.0 %, and repeatability CV ranged from 1.0 to 3.3 % across all concentration levels. The relative mean bias ranged from 0.1 to 3.9 % for native serum levels, and from -2.6 to 2.8 % for lithium-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment were 1.5-4.1 % and 0.9-1.0 %, respectively. CONCLUSIONS: In this study, we introduce an innovative LC-MS/MS-based candidate RMP specifically designed for primidone in human serum and plasma. Our RMP offers a traceable platform, facilitating the standardization of routine assays and enabling the evaluation of clinically relevant samples. With this novel approach, we aim to enhance the accuracy and reliability of primidone measurements, ultimately benefiting the field of clinical research and patient care.


Assuntos
Primidona , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Primidona/sangue , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Padrões de Referência , Reprodutibilidade dos Testes , Técnicas de Diluição do Indicador , Limite de Detecção , Anticonvulsivantes/sangue , Espectrometria de Massa com Cromatografia Líquida
2.
Clin Chem Lab Med ; 62(7): 1288-1300, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38105272

RESUMO

OBJECTIVES: To describe and validate an isotope dilution-liquid chromatograph-tandem mass spectrometry (ID-LC-MS/MS) based reference measurement procedure (RMP) for zonisamide to accurately measure serum and plasma concentrations. METHODS: Quantitative nuclear magnetic resonance (qNMR) spectroscopy was employed to determine the absolute content of the reference material used in order to establish traceability to SI units. Separation of zonisamide from known or unknown interferences was performed on a C8 column. For sample preparation a protocol based on protein precipitation in combination with a high dilution step was established. Assay validation and determination of measurement uncertainty were performed based on guidelines from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the expression of uncertainty in measurement. RESULTS: The RMP was proven to be highly selective and specific with no evidence of a matrix effect, allowing for quantification of zonisamide within the range of 1.50-60.0 µg/mL. Intermediate precision was <1.4 % and repeatability CV ranged from 0.7 to 1.2 % over all concentration levels. The relative mean bias ranged from 0.0 to 0.8 % for native serum levels and from 0.2 to 2.0 % for Li-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment ranged from 1.1 to 1.4 % and 0.8-1.0 %, respectively. CONCLUSIONS: We present a novel LC-MS/MS-based candidate RMP for zonisamide in human serum and plasma which provides a traceable and reliable platform for the standardization of routine assays and evaluation of clinically relevant samples.


Assuntos
Isoxazóis , Espectrometria de Massas em Tandem , Zonisamida , Humanos , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Zonisamida/sangue , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Isoxazóis/sangue , Padrões de Referência , Técnicas de Diluição do Indicador , Análise Química do Sangue/métodos , Análise Química do Sangue/normas , Espectrometria de Massa com Cromatografia Líquida
3.
Clin Chem Lab Med ; 61(11): 1942-1954, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37466369

RESUMO

OBJECTIVES: Topiramate is an antiepileptic drug (AED) used for the monotherapy or adjunctive treatment of epilepsy and for the prophylaxis of migraine. It has several pharmacodynamic properties that contribute to both its clinically useful properties and observed adverse effects. Accurate measurement of its concentration is therefore essential for dose adjustment/optimisation of AED therapy. Our aim was to develop and validate a novel reference measurement procedure (RMP) for the quantification of topiramate in human serum and plasma. METHODS: An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) method in combination with a protein-precipitation-based sample preparation allows for quantification of topiramate in human serum and plasma. To assure traceability to SI units, quantitative nuclear magnetic resonance (qNMR) was applied to characterize the reference material used as primary calibrator for this RMP. Matrix effects were determined by performing a post-column infusion experiment and comparing standard line slopes. Accuracy and precision was evaluated performing an extensive five day precision experiment and measurement uncertainty was evaluated according Guide to the Expression of Uncertainty in Measurement (GUM). RESULTS: The method enabled topiramate quantification within the range of 1.20-36.0 µg/mL without interference from structurally related compounds and no evidence of a matrix effect. Intermediate precision was ≤3.2 % and repeatability was 1.4-2.5 % across all concentration levels. The relative mean bias was -0.3 to 3.5 %. Expanded measurement uncertainties for target value assignment (n=6) were found to be ≤2.9 % (k=2) independent of the concentration level and the nature of the sample. CONCLUSIONS: In human serum and plasma, the RMP demonstrated high analytical performance for topiramate quantification and fulfilled the requirements on measurement uncertainty. Traceability to SI units was established by qNMR content determination of the topiramate, which was used for direct calibration of the RMP. This RMP is, therefore, fit for purpose for routine assay standardization and clinical sample evaluation.


Assuntos
Plasma , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Topiramato , Espectrometria de Massas em Tandem/métodos , Técnicas de Diluição do Indicador , Anticonvulsivantes , Isótopos , Padrões de Referência
4.
REME rev. min. enferm ; 10(3): 253-258, jul.-set. 2006.
Artigo em Português | BDENF - Enfermagem, LILACS | ID: biblio-1029330

RESUMO

Este estudo teve como objetivos identificar os valores que embasam o atendimento às vitimas no Serviço de Atendimento Móvel de Urgência (SAMU) e conhecer os aspectos éticos que norteiam o atendimento às vítimas em relação ao modo de cuidar do enfermeiro. Foram entrevistados treze enfermeiros. Realizada análise segundo Bardin. Unidades temáticas: reconhecimento dos valores intrínsecos ao atendimento humanizado: cuidando da vítima e da família; reflexões éticas na abordagem às vítimas; o cuidado com a equipe de trabalho e a relação do perfil profissional com o cuidar. Os resultados mostraram que a ética como instrumento no modo de cuidar reflete na qualidade da assistência.


This study intended to identify the values underlying care for victims in the ambulance service and get to know ethical aspects in caring for victims, in order to guide nurses in their care. Thirteen nurses were interviewed and Bardin's analysis was used. The issues discussed were: recognizing intrinsic values in humane care; caring for the victim and family; ethical reflections on caring for the victims; care with the work team and relationship between professional training and healthcare. The results showed that ethics as an instrument in care affects the quality of the care.


This study intended to identify the values underlying care for victims in the ambulance service and get to know ethical aspects in caring for victims, in order to guide nurses in their care. Thirteen nurses were interviewed and Bardin's analysis was used. The issues discussed were: recognizing intrinsic values in humane care; caring for the victim and family; ethical reflections on caring for the victims; care with the work team and relationship between professional training and healthcare. The results showed that ethics as an instrument in care affects the quality of the care.


Assuntos
Humanos , Ambulâncias , Serviços Médicos de Emergência/ética , Ética em Enfermagem , Enfermagem em Emergência/ética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...