Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 21(23)2021 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-34883967

RESUMO

The goal of the work was to investigate the possible application of factor analysis methods for processing X-ray Fluorescence (XRF) data acquired with a full-field XRF spectrometer employing a position-sensitive and energy-dispersive Gas Electron Multiplier (GEM) detector, which provides only limited energy resolution at a level of 18% Full Width at Half Maximum (FWHM) at 5.9 keV. In this article, we present the design and performance of the full-field imaging spectrometer and the results of case studies performed using the developed instrument. The XRF imaging data collected for two historical paintings are presented along with the procedures applied to data calibration and analysis. The maps of elemental distributions were built using three different analysis methods: Region of Interest (ROI), Non-Negative Matrix Factorisation (NMF), and Principal Component Analysis (PCA). The results obtained for these paintings show that the factor analysis methods NMF and PCA provide significant enhancement of selectivity of the elemental analysis in case of limited energy resolution of the spectrometer.

2.
Sensors (Basel) ; 21(13)2021 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-34203305

RESUMO

In this paper, we present a modular Data Acquisition (DAQ) system for simultaneous electrical stimulation and recording of brain activity. The DAQ system is designed to work with custom-designed Application Specific Integrated Circuit (ASIC) called Neurostim-3 and a variety of commercially available Multi-Electrode Arrays (MEAs). The system can control simultaneously up to 512 independent bidirectional i.e., input-output channels. We present in-depth insight into both hardware and software architectures and discuss relationships between cooperating parts of that system. The particular focus of this study was the exploration of efficient software design so that it could perform all its tasks in real-time using a standard Personal Computer (PC) without the need for data precomputation even for the most demanding experiment scenarios. Not only do we show bare performance metrics, but we also used this software to characterise signal processing capabilities of Neurostim-3 (e.g., gain linearity, transmission band) so that to obtain information on how well it can handle neural signals in real-world applications. The results indicate that each Neurostim-3 channel exhibits signal gain linearity in a wide range of input signal amplitudes. Moreover, their high-pass cut-off frequency gets close to 0.6Hz making it suitable for recording both Local Field Potential (LFP) and spiking brain activity signals. Additionally, the current stimulation circuitry was checked in terms of the ability to reproduce complex patterns. Finally, we present data acquired using our system from the experiments on a living rat's brain, which proved we obtained physiological data from non-stimulated and stimulated tissue. The presented results lead us to conclude that our hardware and software can work efficiently and effectively in tandem giving valuable insights into how information is being processed by the brain.


Assuntos
Encéfalo , Neurônios , Animais , Estimulação Elétrica , Eletrônica , Microeletrodos , Ratos
3.
Urol Case Rep ; 36: 101561, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33511035

RESUMO

In literature, few cases have been reported regarding the use of alteplase installation in a nephrostomy as anticoagulant treatment of blood clots in the upper urinary tract. Our case -report provides a unique case of alteplase installation in the nephrostomy tube for thrombolysis of a blood clot formation in the upper ureter. The blood clot formation emerged as acute obstruction following a planned endoscopic lithotripsy. A new protocol for alteplase installation for percutaneous nephrostomy is presented in this article.

4.
Sensors (Basel) ; 22(1)2021 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-35009648

RESUMO

SALT, a new dedicated readout Application Specific Integrated Circuit (ASIC) for the Upstream Tracker, a new silicon detector in the Large Hadron Collider beauty (LHCb) experiment, has been designed and developed. It is a 128-channel chip using an innovative architecture comprising a low-power analogue front-end with fast pulse shaping and a 40 MSps 6-bit Analog-to-Digital Converter (ADC) in each channel, followed by a Digital Signal Processing (DSP) block performing pedestal and Mean Common Mode (MCM) subtraction and zero suppression. The prototypes of SALT were fabricated and tested, confirming the full chip functionality and fulfilling the specifications. A signal-to-noise ratio of about 20 is achieved for a silicon sensor with a 12 pF input capacitance. In this paper, the SALT architecture and measurements of the chip performance are presented.

5.
Sensors (Basel) ; 20(10)2020 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-32422952

RESUMO

In this paper, we report on the systematic study of different variants of X-ray detectors based on GEM technology using modified GEM foils with greatly reduced amount of copper. The main goal of this study was understanding the performance of such detectors applied in X-Ray Fluorescence (XRF) elemental analysis. Reduction of the amount of copper in the detector structure is crucial for suppression of XRF background from copper, but one has to ensure that key detector parameters are not affected by such modification. The tested detector variants include detectors with different types of copper-less GEM foils, which have been manufactured starting from standard copper-clad foils and removing partially the copper layer in additional post-processing steps. The results are analyzed and discussed with a particular focus on the energy resolution, uniformity of gas gain and energy resolution across the detector area, and on the long-term stability of the gas gain. Long-term stability tests performed for selected detectors do not indicate for any accelerated aging of the copper-less detectors compared to standard detectors using copper-clad GEM foils. The presented results lead us to conclude that the copper-less GEM detectors are promising devices to suppress the XRF background.

6.
J Nucl Cardiol ; 20(4): 609-15, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23709278

RESUMO

BACKGROUND: The diagnostic sensitivity of various SPECT MPI procedures was assessed using a pumping cardiac phantom with variable defects inserted in the myocardial wall of the left ventricle. METHODS AND RESULTS: A diagnostic evaluation of 142 myocardial defects was performed. A diagnosis blinded to prior-known conditions was compared to the known defects severity (transmural, subendocardial) and defects position within the myocardial wall of the left ventricle (apical, anterior, inferior) for three body types (average male, large male, large female). Non-attenuation corrected, attenuation corrected and gated SPECT MPI were performed. The diagnostic sensitivity was improved when applying attenuation correction or gating techniques to identify subendocardial defects in the inferior, anterior and apical segments of the myocardial wall of the left ventricle for all three body types. Transmural defects could be identified without any attenuation correction or gating. CONCLUSIONS: The diagnostic sensitivity was improved when applying AC or GSPECT techniques.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Miocárdio/patologia , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Artefatos , Diástole , Desenho de Equipamento , Feminino , Ventrículos do Coração/anormalidades , Ventrículos do Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Sensibilidade e Especificidade , Sístole , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...